Estimation for Watershed pollutant loading with SWMM (SWMM 모형을 이용한 유역의 오염부하량 산정)

  • 전지홍;윤춘경
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1999.10c
    • /
    • pp.689-694
    • /
    • 1999
  • This study estimated average yearly watershed pollutant loading by using SWMM(Storm Water Management Model) which is one of the nonpoint source quality models. Two sites were measured discharge and water quality at dry period and wet period. The rainfall data is used from 1989 to 1998 . During a decade, the average year watershed pollutant loading, which is SS, BOD5 , TN, TP, were 2.39E+06kg, 0.92E +05kg, 2.53E+05kg, 2.66E+04kg respectively. During dry period, SS, BOD5 TN, TP loadings were 1.89E+05kg, 1.7E+05kg, 1.04E+05kg, 1.11E+04kg, and during wet period 1.89E+05kg, 1.17E+05kg, 1.04E+05kg, 1.11E+04kg respectively so wet period loading are more than dry day loadings.

  • PDF

Treatment Efficiency of Existing Forms of Pollutants in Sewage Treatment Plant by Natural Purification Method (자연정화공법에 의한 하수처리장에서 오염물질의 존재형태별 처리효율)

  • Seo, Dong-Cheol;Lee, Byeong-Ju;Hwang, Seung-Ha;Lee, Hong-Jae;Cho, Ju-Sik;Lee, Sang-Won;Kim, Hong-Chul;Heo, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.25 no.2
    • /
    • pp.129-137
    • /
    • 2006
  • A study was conducted to investigate the behavior of pollutant forms at each area in the sewage treatment plant by natural purification method. The sewage treatment plant by natural purification method that consisted of aerobic and anaerobic area was constructed. The efficiency of sewage treatment depending on the operation time, the loading amount of pollutant season variation were investigated. The removal amount of BOD, COD, TOC and SS in the aerobic area was significantly increased as the treatment proceeded. Decreased BOD, COD, TOC, SS, T-N and T-P depending on the loading amount of pollutants in the aerobic and ananerobic area were mostly insoluble BOD (IBOD), insoluble COD (ICOD), soluble TOC (STOC), volatile SS (VSS), dissolved T-N (DTN) and dissolved T-N (DTP) types, respectively. The removal efficiency of BOD, COD, TOC, SS, T-N and T-P in hot season (summer and autumn) were more than that in cold season (spring and winter). The removal efficiencies of BOD, COD, TOC, SS, T-N and T-P of the effluent were about 92, 89, 73, 95, 46 and 84% in all seasons, respectively.

Wetland Performance for Wastewater Treatment in Growing and Winter Seasons (생장기와 동절기의 인공습지 오수처리 성능)

  • 윤춘경
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.41 no.4
    • /
    • pp.37-46
    • /
    • 1999
  • Field experimnet of constructed wetland for rural wastewater treatment was performed from July 1998 to April 1999 including winter to examine the seasonal effect on the wetland performance. The system worked without freezing even under $-10^{\circ}C$ of air temperature as long as watewater was flowing. BOD removal rates varied in similar pattern as the air temperature, and winter performance was relatively lower than that in the growing season. However, removing performance during winter was still significant, and BOD removal rates were almost the the same as in the growing season. SS removal rate was relativelyless affected by temmperature, but lower decay rate during the winter can result in accumulation of the SS in the system, which releases constituents in the next spring and can affect whole system performance. The winter removal rates of nutrients like T-N and T-P were decreased about half compared to the growing season and low temperature. To maintain stabilized wetland performanced including winter time, supplying minimum heating for plants could be an alternative in field application. Experimental data was compared with NADB(North Americal Wetlands for Water Quality treatment database), and general performance of the system was within the reasonable range. The pollutant loading and effluent concentration of the experimented system were in high margin. Base on the experiment and databases, the required effluent water quality could be achieved if loading rate adjusted as ilulstrated in the database.

  • PDF

Performance Evaluation of Modified Zeolite with Mg for the Treatment of Dyeing Wastewater (Mg으로 개질한 Zeolite를 이용하여 염색공장 폐수처리 평가)

  • Choi, Hee-Jeong
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.4
    • /
    • pp.392-398
    • /
    • 2015
  • The aim of this study was to investigate the bio-adsorption using modified zeolite with Mg (Mg-zeolite) in the dyeing wastewater treatment. Mg-zeolite adsorbed successfully 100% of the color, suspended solid (SS). chemical oxygen demand (COD), biological oxygen demand (BOD), total nitrogen (TN) and total phosphorus (TP) in the dyeing wastewater at the following optimal Mg-zeolite loading: 20 mg/L for colour, SS, TN and TP, 30 mg/L for BOD and COD. These results indicated that the amount of 1 mg/L Mg-zeolite adsorbed 11.6 mg/L for color, 9.5 mg/L for SS, 45.0 mg/L for COD, 12.7 mg/L for BOD, 0.91 mg/L for TP and 2.25 mg/L for TN. The bio-adsorbent, Mg-zeolite, can be a promising adsorption due to its high efficiency and low dose requirements.

The runoff characteristics of non-point source to urban stream during rainfall (강우 시 도시 하천으로의 비점오염원 유출특성)

  • Park, Woon-Ji;Kim, Dong-Oog;Ahn, Johng-Hwa;Lee, Chan-Ki
    • Journal of Industrial Technology
    • /
    • v.27 no.B
    • /
    • pp.83-89
    • /
    • 2007
  • We studied runoff characteristics of combined sewer overflows in a city while it was raining. The event mean concentration (EMC) of biochemical oxygen demand (BOD), chemical oxygen demand ($COD_{Cr}$), suspended solids (SS), total nitrogen (TN), and total phosphorus (TP) in one of the combined sewer sites in Chuncheon was 63.5-211.6 mg/L, 114.9-523.8 mg/L, 70.3-436.4 mg/L, 6.4-33.0 mg/L, and 1.09-6.81 mg/L, respectively. In another combined sewer, the EMC of BOD, COD, SS, TN, and TP was 42.1-131.4 mg/L, 107.7-256.5 mg/L, 33.7-221.1 mg/L, 7.9-26.4 mg/L, and 1.16-3.91 mg/L, respectively. The ratio of the cumulative pollutant mass and the cumulative discharged volume determined using all parameters (BOD, $COD_{Cr}$, SS, TN, and TP) was over 1.0, which shows the first flush effect. Relationships between flow and loadings of BOD, $COD_{Cr}$, SS, TN, and TP were 0.90, 0.89, 0.88, 0.89, 0.92, respectively. Although the size of two areas was almost same, pollutant concentration and loading were different because of the amount of rainfall, rainfall intensity and basin area.

  • PDF

Water Quality Analysis in Nakdong River Tributaries Using 2012-2016 Monitoring Data (2012-2016년 모니터링 자료를 이용한 낙동강 지류·지천 수질 특성 분석)

  • Son, Younggyu;Na, Seungmin;Im, Tae Hyo;Kim, Sang-hun
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.6
    • /
    • pp.680-688
    • /
    • 2017
  • Water quality monitoring for flow rates and BOD/COD/T-N/T-P/SS/TOC concentrations has been conducted in Nakdong river tributaries since 2011. In this study concentrations and loading rates of BOD, T-P, and TOC were analyzed to evaluate water quality monitoring stations using accumulated data at 206 tributary monitoring stations in Nakdong river 2012 ~ 2016. Average concentration ranges for 206 monitoring stations were 0.3 ~ 6.4 mg/L, 0.025 ~ 1.562 mg/L, and 0.6 ~ 10.7 mg/L for BOD, T-P, and TOC, respectively. Additionally, average loading rate ranges were 0.96 ~ 46,040 kg/d, 0.087 ~ 1,834 kg/d, and 1.51 ~ 80,425 kg/d for BOD, T-P, and TOC, respectively. Average concentration for BOD, T-P, and TOC at each monitoring station was evaluated using ambient water quality standards of rivers and water quality regulation level for medium-sized management areas. Average loading rate and specific loading rate (loading rate/drainage basin area) for BOD, T-P, and TOC at each monitoring station was considered to evaluate monitoring stations using suggested classification (BOD, TOC: -1, 1 ~ 10, 10 ~ 100, 100 ~ 1,000, and 1,000 ~ kg/d; T-P: -0.1. 0.1 ~ 1, 1 ~ 10, 10 ~ 100, and 100 ~ kg/d) Using results of this study, various water quality status maps were provided, and three evaluation methods were suggested to determine priority monitoring stations in Nakdong river for rational water quality control and tributaries basin management.

Contribution of Non-Point Pollution to Water Quality and Runoff Characteristics from Agricultural Area of the Upstream Watersheds of Lake Chinyang

  • Lee, Chun-Sik;Jang, Seong-Ho
    • Journal of Environmental Science International
    • /
    • v.22 no.3
    • /
    • pp.259-267
    • /
    • 2013
  • In this study, non-point source(NPS) contribution was investigated based on flow rates and water qualities of streams into the lake during rainfall events. Event mean concentration(EMC) and the pollution loads were calculated to establish a database for NPS control measurement in the survey area, and so on. The runoff characteristics of NPS were investigated and estimated on the basis of the ratio of an agricultural to forest area in the stream of sub-catch basin during rainfall events. Non-point source pollution loads were also calculated to establish a database for NPS control measure in the upstream lake Chinyang. At a rainfall event, BOD concentrations rise sharply at the early peak time of runoff, however, peaks of TSS concentration were observed at the similar time of peak flow. This was a phenomenon shown at the watersheds caused by forest and geological types. The discharged EMC range was 2.9-4.8 mg/L in terms of BOD. The discharged EMC range was 6.2-8.2 mg/L in terms of SS. The discharged EMCs of T-N and T-P were 1.4-2.5 mg/L and 0.059-0.233 mg/L, respectively. Total BOD loading rate through the 3 tributaries to the lake Chinyang was 1,136 kg/d during dry weather. The upper watershed area of the Nam-river dam in this study was divided into 14 catchment basins based on the Korean guideline for total maximum daily load(TMDL) of water quality pollutants. The higher the agricultural land-use ratio, the more NPS loading rate discharged, but the more occupied a forest area, the lower more NPS loading rate discharged. In an agricultural land-use area more than 20%, the increase of NPS loadings might be dramatically diffused by increasing the integrated complex-use like vinyl-house facilities and fertilizer use etc. according to the effective land-use utilization. The NPS loading rates were BOD 0.3 $kg/ha{\cdot}day$, SS 0.21 $kg/ha{\cdot}day$, TN 0.02 $kg/ha{\cdot}day$, TP 0.005 $kg/ha{\cdot}day$ under less than 10% agricultural land-use. In agricultural land-use of 20%-50%, these values were investigated in the range of 0.32 $kg/ha{\cdot}day$-0.73 $kg/ha{\cdot}day$ for BOD, 0.92 $kg/ha{\cdot}day$-3.32 $kg/ha{\cdot}day$ for SS, 0.70 $kg/ha{\cdot}day$-0.90 $kg/ha{\cdot}day$ TN, 0.03 $kg/ha{\cdot}day$-0.044 $kg/ha{\cdot}day$ for TP.

Effect for CSOs Storage Construction - Analysis of Storm Water Run-off Characteristics in combined sewer system (합류식 하수관거 월류수 저장 시설에 대한 효과 - 강우시 합류식 하수관거에서의 오염물질 유출특성 분석)

  • Park, Jin-Kyu;Lee, Nam-Hoon;Kim, Hae-Ryong;Lee, Woong;Lee, Chae-Young
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.6
    • /
    • pp.949-957
    • /
    • 2011
  • This aim of study was to investigate the characteristics of discharge of pollutants as well as the correlation between flow rate and water quality constituents in a combined sewer system according to the characteristics of rainfall. For the loading rates for each pollutant, the median concentrations of all pollutants except T-N was increased when a CSO took place. The loading rates of BOD, COD, SS, T-N, T-P, Cu and Zn at the CSOs were 328-1255, 25-129, 83-2009, 4-12, 14-51, 5-11 and 5-13 times higher than the DWF (Dry Whether Flow), respectively. Especially, SS loading rate was found to be highest in all pollutants. On the other hand, the range of the first flush coefficient, b for water quality constituents such as BOD, COD, SS, T-N, T-P, Cu and Zn were 0.537-0.878, 0.589-0.888, 0.516-1.062, 0.852-1.031, 0.649-0.954, 0.975-1.015 and 0.900-1.114, respectively. In term of correlation between flow rate and pollutant concentrations, SS concentration was highly correlated to flow rate. However, there was an inverse correlation between EC (Electrical Conductivity) and flow rate because of the high dilution of flow rate. In case of correlation between pollutants, there was a high correlation between SS and T-P.

A Study on Agricultural the Treatment of Organic Phosphorous Agricultural Pesticides Wastewater by the Activated Sludge Process (활성슬러지공정에 의한 유기인계 농약폐수처리)

  • 최택열;최규철
    • Journal of Environmental Health Sciences
    • /
    • v.21 no.2
    • /
    • pp.36-41
    • /
    • 1995
  • In order to treat effectively various type of wastewater discharged from the manufacture factory of organic phosphorous agricultural pesticides by the activated sludge process. The acclimation test of sludge was carried out by the dilution of completely mixed raw wastewater. The results of experiment were obstained as follows. 1. The moderate dilution rate of mixed raw wastewater was founded to about 30 times. 2. The available range of BOD-SS loading was 0.1~0.15 $kg\cdot BOD/kg\cdot SS\cdot day$ and it was similar to the case of extended aeration activated sludge process. 3. After the acclimation of activated sludge, the concentration of MLSS was 2000 mg/L, removal efficiency of BOD more than 90%, and SVI 100, respectively. 4. The oxygen respiratory rate of acclimated sludge was $47 mg\cdot O_2/g\cdot hr$ and this was increased about 5 times than $10 mg\cdot O_2/g\cdot hr$ of ordinary sludge.

  • PDF

A Study on the Wastewater Treatment Characteristics of the Intermediately Aerated Fluidized Bed (간접포기식 유동상법에 의한 폐수처리 특성에 관한 실험적 연구)

  • Lee, Jeoung Su;Kim, Hwan Gi
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.14 no.2
    • /
    • pp.367-378
    • /
    • 1994
  • The wastewater treatment characteristics of the fluidized bed filled with sand media and intermediately aerated were studied experimentally, and the obtained results were as follows; 1. The formations of biofilm on the media were greatly affected by the recirculation velocities. 2. Under the experimental condition that BOD loading rate was $4.2kg-BOD_5/m^3{\cdot}d$, the optimum media concentration was $261kg/m^3$ and the optimum recirculation velocity 1.35 cm/sec. 3. For the effluent quality of 20 mg-BOD/l and 20 mg-SS/l, the maximum allowable loading rate was about $8kg-BOD_5/m^3{\cdot}d$. 4. The dry density of biofilm was about 5.6% regardless of the filled media quantities and recirculation velocities. 5. Under the experimental conditions, the effluent solids concentration was below 20 mg/l, and the elimination of final clarifier can be expected.

  • PDF