• Title/Summary/Keyword: BOD reduction

Search Result 189, Processing Time 0.03 seconds

Analysis of Non-Point Source Pollution Reduction using Water Sensitive Urban Design in Gimhae, South Korea (김해시 물 순환 개선 도시계획에 의한 비점오염물질 저감효과 분석)

  • Jung, Kang-Young;Kim, Shin;Kwon, Hun-Gak;Yang, Duk Seok;Kim, Kyosik;Jang, Kwang-Jin;Shin, Dong-Seok;Ahn, Jung-Min
    • Journal of Environmental Science International
    • /
    • v.25 no.11
    • /
    • pp.1499-1509
    • /
    • 2016
  • This study was performed to analyze the effects of a water circulation green area plan on non-point source pollution in Gimhae South Korea. A quantitative analysis of Arc-GIS data was conducted by applying a watershed model based on Fortran to investigate the changes to direct runoff and pollution load. Results showed that prior to the implementation of the water circulation green area plan in Gimhae, direct runoff was $444.05m^3/year$, total biological oxygen demand (BOD) pollution load was 21,696 kg/year, and total phosphorus (TP) pollution load was 1,743 kg/year. Implementation of the development plan was found to reduce direct runoff by 2.27%, BOD pollution load by 1.16% and TP pollution load by 0.19% annually. The reduction in direct runoff and non-point source pollution were attributed to improvements in the design of impermeable layers within the city.

Application of Surface Cover Materials and Soil Amendments for Reduction of Non-Point Source Pollution from Upland Fields (배추와 무밭에서 발생하는 비점오염원 저감을 위한 피복재와 토양개량제 적용)

  • Shin, Min Hwan;Jang, Jeong Ryeol;Shin, Hyun Jun;Kum, Dong Hyuk;Choi, Yong Hun;Won, Chul Hee;Lim, Kyoung Jae;Choi, Joong Dae
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.55 no.4
    • /
    • pp.21-28
    • /
    • 2013
  • The objective of the study was to investigate the effect of rice straw mat, rice straw mat with PAM (Polyacrylamide) and gypsum addition on surface runoff and sediment discharge in field. Six experimental plots of $5{\times}22m$ in size and 3 % in slope prepared on gravelly sandy loam soil were treated with control, rice straw mat cover with gypsum and rice straw mat cover with gypsum and PAM. Radish in Spring and Chinese cabbage in autumn growing seasons were cultivated. Non point source (NPS) pollution discharge was monitored and compared among the treatments. Rainfall of the 10 monitored events ranged from 17.0 mm to 93.5 mm. Runoff coefficient of the events was 0.005~0.239 in control plot, 0~0.176 in rice straw plot with gypsum and 0~0.046 in rice straw mat plot with gypsum and PAM. When compared to the control plot, the runoff amount was reduced by 10.4~100 % (Ave. 60.8) in rice straw plot with gypsum and 80.7~100 % (Ave. 96.7 %) in rice straw mat plot with gypsum and PAM. The reduction of NPS pollution load was 54.6 % for BOD5, 71.5 % for SS, 41.6 % for TN and 61.4 % for T-P in rice straw with gypsum plot and 91.9 % for BOD5, 92.0 % for SS, 88.0 % for TN and 88.5 % for T-P in rice straw mat with gypsum and PAM plot. This research revealed that rice straw mat cover with soil amendments on the soil surface could not only increase the crop yield but also reduce the NPS pollution loads substantially.

The Study on the Quantification of Pollution Load Reduction Effect of Non-Point Pollution Reduction Facilities (비점오염저감시설의 오염부하 저감효과 정량화 연구)

  • Jeong, Hyeonyong;Kum, Donghyuk;Yu, Nayeong;Woo, Soomin;Lim, Kyoungjae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.313-313
    • /
    • 2021
  • 남·북한강 상류 수계에는 만대지구, 가아지구, 자운지구, 도암호유역, 골지천유역, 대기지구 등 총 6개의 비점오염원관리지역이 지정되어 있으며, 비점오염원관리를 위한 관리대책 및 시행계획에 따라 지속적으로 비점오염저감시설이 설치·운영되고 있다. 그러나, 기후변화에 따른 집중호우 등의 원인으로 뚜렷한 비점오염 저감효과가 나타나지 않고 있으며, 개별 비점오염 저감시설의 명확한 저감효율이 정량화되지 않아 탁수저감 기여도 및 효율성 평가 시 한계가 있다. 따라서 본 연구에서는 문헌연구를 통하여 비점오염저감시설별 저감효율 제시가 미흡하였던 시설 중 돌망태, 식생토낭에 대해 실험을 진행하였다. 저감효율 평가를 위해 경사도 3%, 사면 폭 4 m, 사면길이 22 m의 시험포를 조성하였다. 강우시 발생하는 유출수를 대조구와 비교하였으며, 영농시기를 고려하여 영농작업을 병행하여 실시하였다. 제거효율법을 통한 저감효율 산정 결과 돌망태와 식생토낭의 SS항목은 80.5%와 73.7%로 저감효율이 가장 높은 것으로 나타났으며, BOD는 71.2%, 60.2%, T-N은 70.5%, 64.7%, T-P는 63.7%, 63.1%로 나타났다. TOC는 46.8%, 38.8%로 다른 항목에 비해 상대적으로 낮은 저감효율이 나타났다. 부하량합산법을 통한 저감효율 산정 결과 돌망태와 식생토낭의 T-N 항목은 78.6%와 70.8%로 저감효율이 가장 높은 것으로 나타났으며, BOD는 77.5%, 65.4%, SS는 76.7%, 67.8%, T-P는 68.4%, 63.7%로 나타났다. TOC는 62.7%, 44.6%로 시설별 뚜렷한 차이가 나타났다. 제거효율법과 부하량합산법을 이용하여 저감효율을 분석한 결과 모든 항목에서 40%이상의 저감효율이 나타났으며, 돌망태가 식생토낭에 비해 저감효과가 좋은 것으로 분석되었다. 경사면의 흙탕물 저감을 위해서는 비점오염저감시설의 설치가 우선되어지나, 탁수저감 기여도 및 저감효율 제시를 위한 정량화는 장기간의 모니터링이 필요하기 때문에 지속적인 모니터링을 통한 효율평가가 이루어져야 할 것으로 판단되며, 본 연구 결과는 향후 비점오염저감시설 설치에 따른 유역 내 오염물질 발생 모의를 위한 모델링의 기초차료로 활용될 수 있을 것으로 기대된다.

  • PDF

Performance Characteristics and Improvement Suggestion of Individual Sewage Treatment in Kyangan Watershed (경안천 유역 소규모 오수처리시설의 처리특성 및 효율개선방안)

  • Jang, Young-ho;Kim, Keug Tae;Jahng, Deok-Jin
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.5
    • /
    • pp.816-821
    • /
    • 2010
  • It has been achieved 109.1 kg/d of BOD reduction that is equivalent to the amount of BOD loading discharged from 21,880 persons and dramatic decrease of the fallout ratio against water quality of effluent, from 42% to 9%, through technical support on ISTPs to be applied by the ISMSGA at the upper area of Geongan river in Yong-In city. It was clearly revealed that the most efficient configuration for ISTP was a series of anaerobic tank, equalization basin, aerobic tank, sedimentation tank, and then effluent tank. Also, the major causes on the fallout ratio of ISTP resulted in the lack of management (67.5%) and imperfect facilities (32.5%). Then, when compared the quantity of water supply with the design capacity of ISTP, the design capacity was estimated as 1.8 or 2.4 folds larger than the real quantity of water supply so that it is essential to punctually consider the key factors such as an estimation methods, the specificity of commission operator and construction by high systematic technologies to improve the water quality for the future.

Effect of separation walls on reduction of suspended solids loading in a combined sewer system (합류식 하수관거내 우오수분리벽 설치에 따른 부유물질 제어효과)

  • Kwon, Chungjin;Lim, Bongsu
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.6
    • /
    • pp.787-796
    • /
    • 2012
  • The purpose of this study is to investigate CSOs(combined sewer overflows) control in the combined sewer with/without separation wall. There is the high correlation between sewage velocity and suspended solid(SS) loading in the sewer without it. The SS/BOD ratio was about 3 times in the area with it, while it was about 5 times in the area without it. Therefore, the accumulated deposit within the sewer has influenced high SS loading in the sewer without it. This study showed that the separation wall installed acquired an acceptable efficiency in controlling the accumulated deposit in the combined sewer. According to this study, the BOD control effect was about 38 % in the sewer with the separation wall, whereas it showed about 24 % in the sewer without it. In this case, it was anticipated that the high pollutant control effect would be expected if the separation wall was installed in the combined sewer.

Advanced Oxidation Processes of Secondary Effluent for Reuse (재사용을 위한 하수처리장 방류수의 고급산화처리)

  • 조일형;송경석;성기석;정문호;이홍근;조경덕
    • Journal of Environmental Health Sciences
    • /
    • v.26 no.3
    • /
    • pp.61-68
    • /
    • 2000
  • The use of photo-catalytic processes in pollution abatement and resource has a significant economic importance. Therefore, the applications of photochemical oxidation of secondary effluent driven by UV, TiO2, TiO2/UV, H2O2/UV and TiO2/H2O2/UV, have been investigated in order to treat the secondary effluent from municipal sewage. Various experimental parameters such as BOD, CODcr, Nurbidity, total P, and SPC were examined in each photo-catalytic reaction system. The results showed that the application of single oxidant such as UV, TiO2 only has a minor effect on parameters reduction (CODcr, BOD, etc) to treat the secondary effluent, whereas the combinations of oxidants increase the removal efficiency. The best removal efficiency in every parameters was achieved by the combination of TiO2, H2O2 and UV. It was also found that the optimum amount of TiO2 for the treatment was 1g/ι to achieve water reuse standard. From the results, the photocatalytic reaction system can be an alternative as a post-treatment to treat the secondary effluent from municipal sewage.

  • PDF

Reuse of Weaving Wastewater with BAF Process (BAF 공정을 이용한 제직폐수의 재이용)

  • Jung, Yong-Jun;Bae, Jong-Hong;Kwon, Koo-Ho;Min, Kyung-Sok
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.6
    • /
    • pp.664-669
    • /
    • 2004
  • An upflow BAF(Biological Aerated Filter) equipped with an expanded clay media was applied to reuse weaving wastewater of water jet loom. The performance of lab-scale biofilter was investigated by the adjustment of EBCTs(Empty Bed Contact Time) and the packing ratio of media, which were changed 1.1 to 3.7hr and 38 to 63%, respectively. In most conditions except 1.1hr of EBCT, BOD, CODcr, SS and Turbidity of the effluent were 1~4mg/L, 7~16mg/L, 1~5mg/L and 5~14NTU, where their removal efficiencies were 76~95%, 82~93%, 63~94% and 59~81%, respectively. From the observation of SEM(Scanning Electron Microscope) photographs of porous clay media, it was revealed that this media provided good performance of retaining microbes effectively. In addition, $0.44~0.49kgVSS/kgBOD_{rem}$. of low sludge reduction was expected. The most efficient back washing cycle and procedure were once per 4 to 9 days and air including collapse-pulsing method, respectively. Therefore, this system can be of use as an weaving wastewater treatment for reuse.

A Study of Non-point Source Reduction Efficiency by Constructed Wetland installed in Flood Pumping Station (빗물펌프장에 설치된 인공습지의 비점오염원 저감효율 연구)

  • Chun, Suk-Young;Kim, Ji-Tae;Lee, Il-Kook;Chang, Soon-Woong
    • Journal of Environmental Impact Assessment
    • /
    • v.23 no.1
    • /
    • pp.67-74
    • /
    • 2014
  • The aim of this study was evaluated the effects of total rainfall, rainfall intensity and antecedent dry days and identify the correlation analysis with the EMC removal efficiency, in order to provide an understanding of the operation and maintenance factors of constructed wetland in flood pumping station. This study was conducted total of 20 monitoring in a catchment(326.2 ha) of constructed wetland in Ga-un flood pumping station located at the downstream of the Wang-suk stream. The determined EMC removal efficiencies were $36.04{\pm}9.45%$ for BOD, $38.50{\pm}13.50%$ for $COD_{Mn}$, $34.34{\pm}13.05%$ for TN and $34.22{\pm}14.27%$ for TP, respectively. These results showed that the pollutants concentration and EMC were reduced while passing through the constructed wetland. In the correlation analysis, the highly correlations with EMC removal efficiency of BOD and $COD_{Mn}$ were observed for total rainfall and rainfall intensity (P<0.05). However, the correlations were not found with TN and TP for rainfall variables.

Deodorization of Pig Feces by Fungal Application

  • Kim, T.I.;Ham, J.S.;Yang, C.B.;Kim, M.K.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.17 no.9
    • /
    • pp.1286-1290
    • /
    • 2004
  • This study was carried out to screen yeasts effective in reducing odor from pig feces. Three isolates from soil and compost sources were selected to treat pig feces. On the basis of morphological and biochemical characteristics, one isolate from compost was Candida rugosa, and two isolates from soil were Candida rugosa and Candida maris. These isolates showed deodorizing activity by reducing the concentration of ${NH}_3$ and R-${NH}_2$. Volatile fatty acids (VFA) are the specific malodorous compounds of pig feces, and the Candida maris from soil showed a 100% reduction of butyric, iso-butyric, and iso-valeric acid in 10% pig slurry medium. However, the Candida rugosa from compost showed a 100% reduction of butyric and iso-butyric acid while that from soil showed a 100% reduction of propionic, butyric acid and iso-valeric acid in the medium. Also, these yeasts were effective in reducing $NH_{4}-N$, soluble-N, and biological oxygen demand (BOD).

Runoff Characteristics of Non-Point Source Pollutants in Storm Event -Case Study on the Upstream and Downstream of Kokseong River, Korea- (강우시 비점오염물질의 유출특성에 관한 연구 -곡성천 상.하류를 대상으로-)

  • Yang Hea-Kun
    • Journal of the Korean Geographical Society
    • /
    • v.41 no.4 s.115
    • /
    • pp.418-434
    • /
    • 2006
  • The study was investigated to runoff characteristics of non-point pollutants according to rainfall in Kokseong river watershed. The result of which is as follows : First of all, major reason which affect the formation of water quality of Kokseong River is judged to be caused by non-point pollution source which flows out from farmland and residential area. Flow of rainfall effluent in the downstream in which direct flow components of urban district and combined sewer overflows of farmland was intervened faster than that in the upstream reacted more promptly. Generation of pollutants by non-point source shows increasing trend in general in accordance with the increase in the intensity of rainfall but it was affected by SS, BOD, COD and T-P in the upstream part whereas BOD, COD and T-N were significantly affected by beginning period of rainfall in the downstream. EMC in the downstream increased approximately 3-315 times as compared to upstream, particularly the discharge of SS5 and T-P were extremely increased. While surface flow out of rainfall effluent in the upstream was only 4.7%, the surface flow in the downstream took up as much as 29%, which was major reason for the increase of EMC. From the above contents, we can see that the change in water quality according to the increase and decrease of effluent at the time of rainfall showed very complex pattern depending on the type of land use, and it is judged that the most important thing for the administration of non-point pollution source is to come up with the solution for the reduction of effluent at the beginning.