• 제목/요약/키워드: BOD loads

검색결과 236건 처리시간 0.028초

호기성 침지여상에 의한 제지폐수처리 (Papermill Wastewater Treatment by Indirect Aerated Submerged Biofilter)

  • 원찬희;권영호
    • 상하수도학회지
    • /
    • 제8권1호
    • /
    • pp.44-52
    • /
    • 1994
  • The purpose of this experimental research was focused to improve the quality of the effluent and the yielded sludge when the papermill wastewater was treated by the indirect aerated submerged biofilter as a second treatment method of papermill wastewater. Changing the various experimental factors(Nutrient additions or not, HRT, F/M ratio, recirculation ratio, etc) with indirect aerated biofilter, the results obtained are as follows. 1. Because of the microbes concentration could be sustained to $9,000mg/l$ in submerged biofilter and then the volumetric organic loads could be increased to $2.7kg-BOD/m^3/day$(that of activated sludge is $0.8kg-BOD/m^3/day$), the reactor volume can be reduced to one third of the activated sludge treatment. 2. Because of the yield coefficient(Y) and the endogenous decay coefficient(kd) were revealed 0.4 and 0.07/d, the yielded sludge volume was reduced by for compared with that of the activated sludgg process. 3. The concentration of the sloughed sludge in the reactor was 2.62~4.01%, so the thickener could be omitted in the papermill wastewater sludge treatment process. 4. When the operating was conducted at HRT of 4hrs, the treatment efficiencies of BOD and COD were obtained 80% and 70%, Therefore operating time can be reduced to one half of the activated sludge treatment.

  • PDF

SWMM을 이용한 조만강 유역 강우-오염물 유출모델링시스템 구축 (Establishment of Rainfall and Contaminants Runoff Modeling System for the Joman River Watershed Using SWMM)

  • 이용진;윤영삼;이남주
    • 한국환경과학회지
    • /
    • 제18권9호
    • /
    • pp.983-992
    • /
    • 2009
  • The purpose of the present study is to analyze pollutant runoff characteristics from non-point sources in Joman River basin. The present study contains analyzed results of rainfall and SS, BOD, COD, TN, TP runoff from Joman River basin. This study contains a sensitivity analysis of parameters that affect the simulation results of rainfall and pollutants runoff. Result of the sensitivity analysis shows that proportion of watershed and impervious areas is the most sensitive to peak discharge and total flowrate for rainfall runoff and that WASHPO is the most sensitive parameter for pollutants runoff. For parameter estimation and verification, flowrate and water quality is measured at the Kangdong Bridge in Haeban stream. A single rainfall event is use to perform parameter estimation and verification. Results of the present study show that total pollutant loads of Joman River basin is 11,600 ton of SS, 452 ton of BOD, 1,084 ton of COD, 515 ton of TN, and 49 ton of TP, respectively. In addition, it is found that contribution ratio of non point source and total source is 89% of SS, 63% of BOD, 61% of COD, 21% of TN, and 32% of TP, respectively.

A Study on Runoff Characteristics of Combined Sewer Overflow(CSO) in Urban Area Using GIS & SWMM

  • Kim, Jae-Hoon;Paik, Do-Hyeon
    • 한국환경보건학회지
    • /
    • 제31권6호
    • /
    • pp.467-474
    • /
    • 2005
  • The runoff characteristics of combined sewer overflow(CSO) in the urban area of Jeonju were investigated and analyzed by using the SWMM (Storm Water Management Model) and GIS. From August to November 2004, investigations on two rainfall events were performed and flowrate, pH, BOD, COD, SS, T-N and T-P were measured. these data were used for model calibration. Using GIS technique, watershed characteristics of study area were calculated. that is, divide into sub_basin, total width, slope, make soil map etc. On the basis of the measured data and the simulation results by SWMM, it could be known that the $80-90\%$ of pollution load are discharged in early-stage storm runoff. SMC(site mean Concentration) for combined sewer system area were BOD 28.1, COD 31.5, SS 186 ppm etc. this is shown that during the rain fall, high concentration of waste was loaded to receiving water. Unit loads of combined sewer system area were BOD 306, COD 410, SS 789, T-N 79, T-P 6.8 kg/ha/yr.

오염총량관리를 위한 남강댐유역 수질자료의 시.공간적 특성 분석 (Temporal and Spatial Analysis of BOD data in Namgang-Dam Watershed for TMDLs)

  • 김상민;김성민;박태양
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2010년도 학술발표회
    • /
    • pp.1355-1359
    • /
    • 2010
  • The purpose of this study is to analyze the spatial characteristics of Namgang-Dam watershed for a Total Maximum Daily Loads(TMDL). Three TMDL target sites, Gyeonghogang1, 2, Namgang-Dam2, are located within Namgang-Dam watershed. Under the current criterion for TMDLs, 3-year arithmetic mean BOD concentration of the target sites should not exceed the target concentration for 2 consecutive years. Two and three times of violation were observed for Gyenghogang2 and Namgang-Dam2 sites while no violation was found for Gyeonghogang1 site. However, no violation was found since 1999 for all three sites. Correlation between each 12 stations within the watershed were analyzed and cluster analysis was conducted to figure out the spatial characteristics of the watershed. Correlation coefficient between Gyonghogang1 and 2 was high (0.758) while the coefficients between lake station (Namgang-Dam2) and stream stations (Gyonghogang1 and 2) were very low. Dendrogram indicated that all of three Namgang-Dam stations were very close and Gyenghogang1, 2 stations were also close.

  • PDF

상향류 및 하향류 생물막여과공정의 처리특성에 관한 연구 (Treatment Characteristics of Biological Aerated Filter Process Using the Upflow and Downflow System)

  • 이양규;김건협
    • 상하수도학회지
    • /
    • 제20권6호
    • /
    • pp.837-848
    • /
    • 2006
  • This paper presents the test results of biological aerated filtration(BAF) process to replace activated sludge process by enhancing treated effluent quality and reducing the costs. In BAF process both BOD and SS compounds in wastewater are degraded and removed by biological reaction and filtration. Upflow BAF with expanded polypropylene media and downflow BAF with ceramic media were used to investigate the effects of hydraulic and organic loads on effluent quality. As a result, in BAF processes which has different media, upflow BAF reactor shows 5% higher efficiency than downflow BAF and this phenomena caused by backwashing methods and operational conditions. The results of influence factors analyzed by Factor Analysis Method in BOD and SS treatment efficiency are the size of media, hight of media bed and type of media. The quantitative effects of media size are 5.73% in TBOD, 5.78% in SBOD and 7.65% in TSS, so we confirmed the main factor is media size.

농업유역관리를 위한 도원천유역의 수질항목간 상관성 분석 (Correlativity Analysis between Water Quality Items in the Dowoncheon Basin for Agricultural Watershed Management)

  • 손재권;최진규;구자웅;송재도;조재영;김영주
    • 한국농공학회논문집
    • /
    • 제48권4호
    • /
    • pp.77-86
    • /
    • 2006
  • This study was performed to investigate the stream water quality characteristics in the Dowoncheon basin of Dongjin River during the 12 months from January to December in 2005. Also, pollutant loads were calculated on the basis of the water quality and runoff results. The measured pH and EC of the stream water were ranged 6.48-7.32, $18.06{\sim}38.60{\mu}S/cm$, respectively. The concentration of DO, BOD, COD, SS, T-N and T-P were observed as 4.90-11.50 mg/L, 0.5-6.0 mg/L, 1.22-18.46 mg/L, 1.0-2,124.0 mg/L, 1.35-5.67 mg/L, 0.02-0.43 mg/L respectively. T-N showed low correlativity with other water quality parameters. However, T-P had very high correlativity with COD and SS. In the meantime, the runoff pollutant loads of T-N, T-P were estimated as 72,114 kg/yr, 5,027 kg/yr. In the case of the correlativity between runoff pollutant loads and concentrations, T-N did not show significant relationships, while T-P had significant relationships.

낙동강(洛東江) 중류수계(中流水系)의 자정능력(自淨能力) 평가(評價) (Assessment of Self-purification Capacity along the Midstream of Nakdong River)

  • 최언호;이서래
    • 한국환경농학회지
    • /
    • 제1권1호
    • /
    • pp.39-47
    • /
    • 1982
  • 1978년부터 1980년까지 3년간 경상북도 상주로부터 경상남도 임해진에 이르는 낙동강(洛東江) 중류(中流)의 12개 지점과 금호강(琴湖江) 및 남강하류(南江下流)의 12개 지점에서 년 4회 (1월, 4월, 7월, 10월)에 걸쳐 DO, BOD, 류양(流量)을 조사하고 이들 자료로 부터 자정능력을 조사한 바 다음과 같은 결과를 얻었다. 1) 금호강(琴湖江) 하류(下流)의 계절별 1일 평균 BOD 부하량(負荷量)은 1월에 94톤, 4월에 39톤, 7월에 60톤, 10월에 54톤으로서 낙동강 본류(本流)의 주요한 오염원(汚染源)으로 인정되었다. 2) 낙동강 본류(本流)에서의 자정계수(自淨係數)를 평가(評價)한 결과 화원-현풍에서의 탈산소계수(脫酸素係數)$(K_1)$$0.21{\sim}0.59$이고 재폭기계수(再曝氣係數)는 $0.56{\sim}2.27$이었다. 그리고 본류(本流)의 산소임계곡선(酸素臨界曲線)을 보면 화원에서 급격히 감소한 용존산소가 현풍에 이르러 거의 회부(回復)현상을 나타냈다. 따라서 금호강으로 인한 낙동강 본류(洛東江 本流)의 오염(汚染)물질은 화원-현풍구간에서 희석 및 자정작용(自淨作用)으로 분해되어 현저하게 감소하였다. 즉 낙동강은 자정능력이 비교적 큰 것으로 나타났다.

  • PDF

BASINS/HSPF와 연계한 유황별 비점유달부하량 산정방법 개발 (Development of a Method for Estimating Non-Point Pollutant Delivery Load of Each Reference Flow with Combination of BASINS/HSPF)

  • 이용운;송광덕;이재춘;윤광식;류덕희;이수웅;이신후
    • 대한환경공학회지
    • /
    • 제32권2호
    • /
    • pp.175-184
    • /
    • 2010
  • 본 연구에서는 유역모형인 BASINS/HSPF와 연계하여 비점유달부하량을 유황별(갈수기, 저수기, 평수기 등)로 산정하는 방법을 개발하고, 이를 전남지역에 위치한 동복천 유역에 적용하여 그 효용성을 평가하였다. 동복천 유역에 대한 BASINS/HSPF 모형의 보정 검증결과는 유출유량, BOD 및 T-P의 신뢰도지수가 각각 1.59, 1.41, 1.28로서 실측값과 예측값의 유사성은 높게 나타났다. 이와 같이 구축된 BASINS/HSPF 모형을 사용하여 동복천 유역의 갈수기, 저수기, 평수기에 대한 BOD와 T-P 비점유달부하량을 각각 구하면, 연간 일평균 비점배출부하량과 대비하여 0.36과 1.09, 0.82와 2.19, 6.02와 16.90이였다. 이러한 결과는 비점유달부하량을 유황별로 산정하여 서로 다르게 반영할 필요성이 있음을 보여주고 있으며, 이러한 경우에 본 연구에서 개발한 유황별 비점오염유달부하량 산정방법은 유용하게 사용될 수 있을 것이다.

진위천 단위유역의 유량-수질 특성 및 하천 등급화 평가 (Evaluation of Discharge-Water Quality Characteristics and River Grade Classification of Jinwi River Unit Basin)

  • 조용철;최진우;노창완;권필상;김상훈;유순주
    • 환경영향평가
    • /
    • 제27권6호
    • /
    • pp.704-716
    • /
    • 2018
  • 본 연구는 진위천 단위유역의 수질오염총량제도에 따른 유량 및 수질 특성을 정확히 파악하고 목표 수질을 달성하기 위하여 수질 개선이 우선적으로 필요한 총량 지점을 선정하여 관리 방안을 제시하는 것이다. 진위천 단위유역의 2014년부터 2016년까지 14개 총량 지점을 대상으로 유량 및 수질 특성, 통계 분석, 유달부하량 및 유달부하 밀도 산정, 하천 등급화 등을 평가하였다. 진위천 단위유역의 유량은 평균 $22.411m^3/s$이고 황구지천의 유량이 32.8%를 차지하였으며 지류 하천에 따른 공간적으로 수질특성이 뚜렷하게 나타났다. 주성분 분석 결과 오산천과 황구지천은 유기오염 간접지표 및 계절적 요인, 성은천은 유기오염 간접지표 요인, 관리천은 계절적 요인이 수질에 영향을 미치는 것으로 분석되었다. 유달부하량 산정 결과 HG-3 지점에서 6,470.4 BOD kg/day, 6,846.7 TN kg/day로 높게 나타났으며 유달부하 밀도는 HG-4 지점에서 $220.9BOD\;kg/day/km^2$, $22.4TP\;kg/day/km^2$로 높게 나타났다. 하천 등급화 방법을 이용한 진위천 단위유역의 수질 개선이 우선으로 필요한 총량 지점은 HG-3 지점으로 나타났다.

서낙동강 유역 해반천의 수질 개선을 위한 비점오염관리대책 효과 분석 (Assessment of the Non-point Source Pollution Control Strategies for Water Quality Improvement in the Haeban Stream of West Nakdong River Watershed)

  • 김예진
    • 한국습지학회지
    • /
    • 제26권1호
    • /
    • pp.1-9
    • /
    • 2024
  • 이 연구에서는 서낙동강을 구성하는 소유역 중 대지면적 비율이 크고 인구밀도가 높은 해반천 유역의 유출 및 수질을 모의하기 위한 HSPF(Hydrological Simulation Program-FORTRAN)모형을 개발하였다. 유역에서 발생하는 비점오염 부하량을 관리하기 위한 세 가지 시나리오가 개발되어 모형에 적용되었고, 오염부하량의 감소와 부하지속곡선에 대비한 수질 기준 초과율이 분석되었다. 시나리오는 비점오염의 발생을 줄이기 위한 도로 청소, 다양한 저영향 개발 기법을 고려한 유출 저감 조치, 그리고 강으로 들어가는 비점오염원을 완화하기 위한 유입 저감 조치로 구성되었다. 첫 번째 시나리오에서는 김해시의 도로 청소 차량 수와 같은 실제 조건이 고려되었으며, 두 번째와 세 번째 시나리오에서는 적용 가능한 토지 이용별 면적의 50%에 저영향 개발 기법을 적용하는 것으로 적용되었다. 모든 세 가지 조치를 적용한 결과, BOD 오염 물질 부하가 58.28%, T-N은 58.49%, T-P는 51.56% 감소할 수 있는 것으로 도출되었다. 또한, 5년간 누적된 수질 측정의 60번째 백분위수를 목표 수질로 설정하고 구축된 유량지속곡선에 의한 초과율분석 결과, 결과적으로, BOD의 경우 조치 적용 전 41.57%의 초과율이 조치 후 16.32%로 감소하여, 초과율이 25.25% 감소하였다. T-N의 경우 조치 전 40.31%에서 조치 후 22.84%로, T-P의 경우 62.43%에서 27.22%로 감소하였다.