• Title/Summary/Keyword: BOD load

Search Result 328, Processing Time 0.024 seconds

Characteristics of Biochemical Oxygen Demand Export from Paddy Fields during Storm and Non-storm Period and Evaluation of Unit Load (강우시와 비강우시 BOD 유출 특성 조사 및 원단위 평가)

  • Choi, Dongho;Cho, Sohyun;Hwang, Taehee;Kim, Youngsuk;Jung, Jaewoon;Choi, Woojung;Park, Hyunkyu;Yoon, Kwangsik
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.5
    • /
    • pp.531-537
    • /
    • 2017
  • The biologic Oxygen Demand (BOD) is a reliable and generally accepted indicator of water pollution by organic pollutants. Accordingly, estimation of BOD export from paddies carries important implications fwith regard to water management in rural areas. In this study, hydrology and BOD concentration were monitored during the period 2008 through 2012, in an effort to understand the characteristics of BOD export from paddy fields. The findings demonstrated that BOD load by rainfall above 50 mm. occupied about 50 % of total load, whereas the load by less than ten mm. rainfall occupied about 29 % of the total load during periods of stormy activity. It therefore seems that it could be possible to reduce the BOD load up to 29 % during storm periods, when drainage control conducted for rainfall less than ten mm.(an amount which is relatively easy to manage). The documented mean loads of storm and non-storm were $17.1kg\;ha^{-1}\;yr^{-1}$ and $11.2kg\;ha^{-1}\;yr^{-1}$, respectively. The BOD load during the significant rainfall period was similar to the renewed unit load by NIER (2014). However, there were substantial differences between unit load and actual load when the non-storm load was incorporated into the BOD load estimation from paddy fields. In view of the foregoing, it is felt that, the non-storm load needs to be further considered and managed for the successful implementation of Total Maximum Daily Load (TMDL) program.

Determination of Focused Control Pollutant Source by Analysis of Pollutant Delivery Characteristics in Unit Watershed Upper Paldang Lake (팔당호 상류의 단위유역별 오염물질 유출특성 분석을 통한 중점관리 오염원 선정)

  • Kim, Dong Woo;Jang, Mi Jeong;Han, Ihn Sup
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.5
    • /
    • pp.367-377
    • /
    • 2014
  • Paldang lake which is the most important water resource in Korea is classified as a stream type reservoir and water quality of Paldang lake can be significantly influenced by external pollutant source. So this study was aimed to determine focused control BOD and TP sources of each unit watershed upper Paldang lake through analysis of pollutant source distribution and pollutant runoff characteristics. Generated load, discharge load, delivery load and each load density of 11 unit watersheds upper Paldang lake were calculated using data of water quality and flow rate from pollutant sources and 74 small streams. As a result of generated load, discharge load and delivery load of BOD and TP from pollutant sources, the most BOD generated load was taken by livestock with 66% of total BOD discharge load and domestic had the most BOD discharge load, 42.7%. The ratio of delivery load of livestock and domestic was 36.4% and 34.3%, respectively. Livestock occupied high ratio of TP generated load, discharge load and delivery load with 82.5%, 44.4% and 46.7%, respectively. Gyeongan watershed which had high population density showed the highest BOD delivery load density of $14.6kg/km^2/d$ and the highest TP delivery load density with $1.23kg/km^2/d$ was analyzed in Cheongmi watershed including the biggest number of livestock. From these results, management of domestic sewer and livestock excrement was determined as a focused control pollutant source. And intensive management about domestic sewer in Gyeongan stream and livestock excrement in Cheongmi stream is required for water quality improvement of Paldang lake.

The Distribution Characteristics of Organic Matters in the Contaminated Tributaries of Han River Region (한강권역 우심지류 하천의 유기물 분포 특성)

  • Kim, Ho-Sub;Park, Yun-Hee;Kim, Yong-Sam;Kim, Sang-Yong
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.5
    • /
    • pp.494-502
    • /
    • 2018
  • The purpose of this study was to understand distribution characteristics of organic matters through concentration of $BOD_5$, $COD_{Mn}$ and TOC in 31 streams in Han River region, and to establish the relationship among organic matter concentration, and discharge load and flow rate. Concentration of $BOD_5$ and TOC in 22 streams were above IV grade except 9, and the average 80.9 % of total organic matter (by TOC) accounted for dissolved organic type. Correlation among organic matter parameters were higher ($r^2$ > 0.78) and the relationship between TOC and $COD_{Mn}$ concentration was higher than $BOD_5$. Ratio of biodegradable organic matter/total organic matter in the 31 streams was estimated at 41.4 % with $BOD_5$ oxidation rate, and 78.0 % with $BOD_5/COD_{Mn}$ concentration ratio. Ratio of $NBOD/BOD_5$ concentration in four sites with $BOD_5/COD_{Mn}$ concentration ratio exceeding 1 ranged from 54.5 % ~ 79.3 %. Among 979 flow rate data measured at 31 streams, 87 % of measured data was below 0.1 cms and increased water pollution under low flow conditions. Correlation between $BOD_5$ concentration and $BOD_5$ discharge load in the watershed was low, and it was revealed that several streams have more $BOD_5$ delivery load than $BOD_5$ discharge load. Results suggest that many biodegradable forms of organic matter are being introduced into the stream from pollutant sources in the watershed.

Organophosphorus Insecticide Residues in Fruits and Vegetables (과실 채소중 잔류농약(유기인제)에 관한 연구)

  • 윤숙자
    • Journal of environmental and Sanitary engineering
    • /
    • v.5 no.1
    • /
    • pp.83-92
    • /
    • 1990
  • Adapting two step aeration system to a waste water treatment of W-paper manufactory as Full-Scale Plants, we drew a following conclusion from its practical working. 1. Because BOD removal efficiency was 20% in A-Stage, 90% in B-Stage and total removal efficiency was 97%. It worked treatment plant well and was suitable for effluent water standard as well. Because COD removal efficiency was 42% in A-stage, 71% in B-stage and the total removal efficiency was 94% COD control was possible in effluent water quality. 2. Treatment efficiency according to a load capacity was average 20% in 1.401 BOD kg/m3/d load of A-Stage and average 90% in 0.273 BOD kg/$\textrm {m}^3$ / d load of B-Stage. 3. Treatment efficiency according to a ratio of F/M was 2.657--5.024 kg BOD/kg MLSS/d in A-Stage and BOD removal efficiency was 16-261 in the same stage. The ratio of F/M was 0.068-0.094 kg BOD /kg MLSS/d and BOD removal efficiency ratio was 85-94%. Therefore treatment efficiency could be kept stably and volume of aeration tank could be reduced wholly. 4. Treatment efficiency according to MLSS appeared BOD 20%. COD 42%, in A-Stage and removal efficiency appeared BOD 90%, COD 71% in B-Stage. They were suitable for plan condition. 5. Because of working of complemented treatment plant by AB-Process. 20,000,000 Won a month was saved than the ordinary working cost. Therefore, it was assumed that invested cost could be recollected in 19 months or so consequently.

  • PDF

An Estimation Study of Watershed Pollution Load Reduction Using Environmental Capacity (환경용량을 고려한 유역 오염부하삭감량 추정 연구)

  • Jung, Jae-Sung;Park, Young-Ki;Kim, Jong-Guk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.12
    • /
    • pp.1265-1273
    • /
    • 2006
  • The environmental capacity and watershed pollution load reduction of Yongdam reservoir were estimated by the simulation of water quality variation process with the target water quality establishment, pollution load estimation and flow analysis. The potable raw water $I{\sim}II$, COD $1.0{\sim}3.0$ mg/L and TP $0.01{\sim}0.03$ mg/L were selected as the target water quality Yongdam reservoir water quality model was constructed with WASP5 contained 42 segments and the correlation of calibrated results were BOD 0.73, $PO_4-P$ 0.98. The environmental capacity for target quality COD 2.0 mg/L and TP 0.02 mg/L were BOD $131,880{\sim}4,694$ kg/d, TP $7,855 {\sim}167$ kg/d which were less than exists, and the related reduction ratios were BOD $51{\sim}62%$, TP $47{\sim}67%$ which were middle amount in exists. The load reduction ratios to meet the potable raw water $I{\sim}II$ were BOD $72{\sim}16%$, TP $78{\sim}36%$ in existing conditions and BOD $81{\sim}44%$, TP $84{\sim}52%$ in new conditions. BOD was the least one and TP was the second least in 4 results. The effects of the load reduction assignment to subbasin were dominant in TP but little in COD.

COD Pollutants Load Estimation Schemes in Lake Shihwa and Incheon Coastal Zone (시화호 및 인천연안의 COD 오염부하량 추정기법)

  • Cho Hong-Yeon;Cho Bum-Jun
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.18 no.3
    • /
    • pp.262-267
    • /
    • 2006
  • For the concentration management in COD parameters, it requires the measurement and estimation of the COD pollutants load (hereinafter PL) in the watershed. The estimation method of the PL, however, is provided only based on the BOD parameters. The development of COD PL estimation schemes is expected to execute total PL management in coastal zone and needs to more observation and much time. This study provides COD PL estimation schemes using statistical information about ratio analysis with COD & BOD concentration of rivers and drainages of an industrial complex in Lake Shiwha and Incheon Coastal Zone watershed. The COD PL is computed with ease by multiplying the conversion factor, which is calculated as the sum of the average and 1 to 3 (safety factors) times standard deviation. The conversion factor of Lake Shihwa and Incheon Coastal Zone is estimated as 1.7, 2.3 and 2.9 with respect to the safety factor 1, 2, and 3, respectively.

Evaluation of Impaired Waterbody and Multivariate Analysis Using Time Series Load Curve -in Jiseok Stream Watershed- (시계열 부하 곡선을 이용한 수체손상 평가 및 다변량 분석 -지석천 유역을 대상으로-)

  • Park, Jinhwan;Kang, Taewoo;Han, Sungwook;Baek, Seunggwon;Kang, Taegu;Yoo, Jechul;Kim, Youngsuk
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.6
    • /
    • pp.650-660
    • /
    • 2017
  • In this study, pollutant emission characteristics by water damage period analyzed 11 items (water temperature, pH, DO, EC, BOD, COD, TOC, SS, T-N, T-P and flow) with load duration curve, time series load curve and factor analysis for three years (2014-2016). Load duration curve is applied to judge the level of impaired waterbody and estimate impaired level by pollutants such as BOD and T-P in this study depending on variation of stream flow. Water quality standard exceeded the flow of mid-range and low-range by flow condition evaluation using load duration curve. This watershed was influenced by point source more than non-point source. Cumulative excess rate of BOD and T-P kept water quality standard for all seasons (spring, summer, autumn and winter) except BOD 59% in spring. Water quality changes were influenced by pollutants of basic environmental treatment facilities and agricultural areas during spring and summer. Results of factor analysis were classified commonly first factor (BOD, COD, and TOC) and second factor (flow, water temperature and SS). Therefore, effects of artificial pollutants and maintenance water must be controlled seasonally and reduced relative to water damage caused by point pollution sources with effluent standard strengthened in the target watershed.

Efficiency of Livestock Farming Wastewater Treatment by Trickling Filters (撒水濾床法에 依한 畜産廢水의 處理效果에 관한 연구)

  • Ahu, Soo Mi
    • Journal of Environmental Health Sciences
    • /
    • v.11 no.2
    • /
    • pp.17-27
    • /
    • 1985
  • The objectives of this study is to examine efficiency of swinery wastewater treatment by trickling filters' pilot plant. The results of this study are as follows: 1. The characteristics of sample. The BOD$_5$ was from 2,450 to 2,880mg/l, COD(KMnO$_4$ acid method) was from 910 to 1,064mg/l, and SS was from 920 to 990mg/l. The pH of influent was from 7.3 to 7.6, and the temperature of water was from 17.0$\circ$C to 22.5$\circ$C. 2. For experiment by recirculation, the BODs removal efficiency is 65.2% at recirculation ratio (r)=0, and 70.7% at r=1. The ramoval efficiency of this study is higher than NRC formula of U.S.A.. The recirculation is not significant effect on removal efficiency. 3. For experiment by hydraulic load, the BOD$_5$ removal rate decreased from 73.1% at $3.1m^3/m^2\cdot d$ to 65.3% at $9.2m^3/m^2\cdot d$. The design formula of this study which shows the removal rate of soluble BOD is $Le/Li =10^{-0.24} D/Q^{0.24}$ (Q: hydraulic load, D: depth of filter). 4. For experiment by organic load, the BOD$_5$ removal rate is increased from 70.2% at $0.77kg/m^3\cdot d$ to 75.4% at $4.28kg/m^3\cdot d$. We can obtain the straight line y=0.749 x (y: removed BOD, x :applied BOD) by the least squares method. 5. We can know that trickling filters is strong with the hydraulic load and the organic matter shock load. Here, we can judge that trickling filters is a good method for the treatment of swinery wastewater which containing high concentrated organic matter.

  • PDF

Estimating BOD, CDO and TOC Hydrologic Flux in Nakdong River Basin (낙동강 유역 BOD, COD 및 TOC의 수문학적 플럭스 추정)

  • Lee, A-Yeon;Park, Moo-Jong;Jo, Deok-Jun;Kim, Sang-Dan
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.9
    • /
    • pp.830-839
    • /
    • 2010
  • This study presents a constituent load estimating procedure that can be operated with the present Korean TMDL monitoring system. The modified TANK model is used as a daily river flow simulation model whose parameters are estimated from 8-day intervals flow data. Constituent loads are estimated with the 7-parameter log linear model whose parameters are estimated by the minimum variance unbiased estimator. Results from Nakdong river basin reveals that the proposed procedure provides satisfactory TOC and BOD load estimates. As an application, a representative load duration curve is derived for working out a way to represent the overall hydrologic flux of BOD, COD and TOC at Nakdong river basin. The present water quality can be checked stochastically by Load Duration Curve through this study and presented visually.

Characteristics of the Pollutants Ronoff on the Tamjin A and B Watershed with Discharge Variation (유량변동에 따른 탐진 A와 B유역에서의 오염물질 유출 특성)

  • Park, Jinhwan;Lim, Byungjin;Jung, Jaewoon;Kim, Daeyoung;Oh, Taeyoun;Lee, Dongjin;Kim, Kapsoon
    • Journal of Environmental Impact Assessment
    • /
    • v.21 no.6
    • /
    • pp.917-925
    • /
    • 2012
  • In this study, we report the runoff characteristics of pollutants for Tamjin A and B watershed in Tamjin river basin using statistical analysis, such as correlation analysis and regression equation. Flow rate and water qualtiy data collected from 2 sampling sites(Tamjin A and B watershed) during 3 years(2009~2011) were analyzed for biochemical oxygen demand(BOD), total nitorgen(TN), total phosphorus(TP) and suspended solid(SS). The results showed that strong correlations were observed between flow rate and SS in Tamjin A, while weak correlations were observed among the BOD, TN, and TP. In Tamjin B, strong correlations were observed among the flow rate, SS and T-P except BOD and TP. Meanwhile, the values of $R^2$ for regression equations between flow rate and pollutants load were greater than 0.7. Results of these statistics indicated that there was a good agreement between flow rate and pollutants load. Also, the flow rate exponents of regression equations for BOD, TN, and TP were smaller than 1 in Tamjin A. In Tamjin B, flow rate exponents of regression equation for BOD and TP were smaller than 1. These results indicated that concentrations of BOD, TN, TP in Tamjin A and concentrations of BOD and TP were decreased as the flow rate was increased. This means that rater than nonpoint sources, point sources affect BOD, TN and TP in Tamjin A and BOD and TP in Tamjin B.