• Title/Summary/Keyword: BOD제거

Search Result 293, Processing Time 0.025 seconds

Phosphorus Removal and Operating Performance of Mesh Filtration Bio-reactor with the Addition of Alum (Alum 주입 메쉬 침지 여과분리형 생물반응조의 운전 특성과 인 제거)

  • Jung, Yong-Jun;Min, Kyung-Sok
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.5
    • /
    • pp.458-463
    • /
    • 2005
  • Considering the characteristics of a filtration bio-reactor equipped with a mesh filter module which can effectively maintain high concentration of biomass and enhanced solid-liquid separation performance, the hybrid process of filtration bio-reactor combined with coagulation was investigated to get improved filtration characteristics as well as water quality in this work. Two bio-reactors (Run-1 & Run-2) were operated under the following conditions: working volume of 25 L, continuous loading of a synthetic wastewater (BOD: 200 mg/L, T-N: 50 mg/L, T-P: 5 mg/L), where an appropriate amount of alum ($Al_2(SO_4)_3{\cdot}18H_2O$) was added once a day into the reactor (Run-2). In the system without using a alum (Run-1), the clogging of mesh filter module was observed two times through 85 days of whole operation. Meanwhile, the filter module did not clog even at higher MLSS concentration (6,000~12,000 mg/L) and the stable filtration (0.7 mid) was continued in the case of using a alum. Due to the stable formation of cake layers, BOD and SS were shown below 6 and 3 mg/L, respectively. T-P and pH of the effluent were changed because of the intermittent addition of the alum. In the case of Al/P=2.5, the average T-P removal efficiency per day was 85.2% and the average T-P concentration of the effluent was 0.3 mg/L. However, the removal efficiency of phosphate was influenced by pH in the reactor.

Site Assessment for the Water Purification Effect of Porous Concrete by using Effective Micro-organisms (유용미생물을 이용한 포러스콘크리트의 수질정화특성에 대한 현장평가)

  • Kim, Bong-Kyun;Park, Jun-Seok;Seo, Dae-Seuk;Kim, Wha-Jung;Kim, Yun-Yung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.1
    • /
    • pp.109-119
    • /
    • 2015
  • In recent years, a rapid growth in the population and urbanization led to an increasing industrial growth. The inadequate treated-wasted water from industry and various non-point sources causes significant negative effects on the stream water. For past few decades, extensive researches have been performed on water purification process. The purpose of this study is to investigate mechanical performance and water purification properties of porous concrete by using effective microorganisms through the site assessment test. The mechanical performance evaluation results showed that the increase void ration caused an decrease in the strength. The optimal mix rate was found to be 15% void rate From the site assessment, it was evaluated that the porous concrete improved the quality of the water and the purification ratios are 34.1 for SS, 14.6% for BOD, 34.9% for COD, 11.4% for T-N, and 12.6% for T-P. The porous concrete and the related purification technique can reduce the non-point pollution sources flowing into the river.

Removal of Total Organic Carbon and Micropollutants in Tertiary Treated Sewage by Medium Pressure UV/H2O2 (중압 자외선과 과산화수소 공정을 이용한 하수 3차 처리수중 총유기탄소와 미량오염물질 제거)

  • Lee, Jai-Yeop;Kim, Ilho
    • Journal of Korean Society on Water Environment
    • /
    • v.36 no.4
    • /
    • pp.314-321
    • /
    • 2020
  • This study evaluated the applicability of UV-AOP process using medium-pressure UV lamp and H2O2 to remove TOC and emerging micropollutants in the effluent from a sewage treatment plant. The UV lamp with higher output(1.6~8.0 kW) showed slightly higher amount of power in removing TOC of 1 mg/L(0.09 kWh/mg/L~0.11 kWh/mg/L), however it was found that there was no significant difference for each cases. In addition, under the condition that the H2O2 concentration is sufficient, as the power consumption of the UV lamp increases, the unit TOC removal concentration per unit H2O2 decomposition concentration also increases, resulting in effective removal of TOC. The removal rate of 7 new trace contaminants, such as antibiotics by the UV-AOP tested, was at least 89.4%, and the ability to remove the emerging micro pollutants in the process was very effective. But, it was judged that it could not be excluded that the probablity of transforming to oxidated by-product in the case of a low TOC removal efficiency. Depending on the operating conditions of the UV and H2O2 processes, a higher BOD concentration is found in the treated water than in the influent, and it is necessary to review the UV power and proper injection conditions of H2O2 to maintain the BOD concentration increase below a certain level.

The Application of the Sewage, Sanitary Sewage and Wastewater Processing by Soil Purification Theory (토양정화법을 이용한 하.오수 및 폐수 처리의 현장적용성에 관한 연구)

  • Chun, Byungsik;Yoo, Junhee;Kim, Jungyong;Kumar, S;Shin, Sanguok;Shin, Bangwoong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.9 no.4
    • /
    • pp.77-84
    • /
    • 2008
  • Soil purification theory is the method using the soil micro-organism like aerobic and anaerobic for treatment of wastewater. The soil has many kinds of micro-organism and it multiply as change of the environment. Unlikely other methods, the soil purification theory is adaptable to inflow water change; moreover, it can process the T-N, T-P without any special method and management. The top is covered with the improved soil which can remove the bad smell and is used for resting place according to planting the lawn. This study is focused on analysis of the treatment processing of wastewater comparing inflow with outflow water. As a results, removal rate of the processing the BOD, COD and SS is almost 90~100% and it is 60~80% in T-N, T-P.

  • PDF

Advanced Treatment of Shipboard Sewage by RCM Process with BM (복합미생물제제를 이용한 RCM공법의 선박오수 처리장치 적용에 관한 연구)

  • Ha, Shin-Young;Kim, In-Soo
    • Journal of Navigation and Port Research
    • /
    • v.38 no.5
    • /
    • pp.451-456
    • /
    • 2014
  • Lab scale experiment was carried out to study biological wastewater treatment technology developed for shipboard. RCM process using BM(Beneficial Microorganisms) was investigated for practical application on shipboard sewage treatment. RCM process is an environmental friendly treatment system, with minimum production of sludge. In the test, BOD5, CODcr, T-N and T-P were reduced a 96%, 97%, 78% and 81.68% respectively. From the result it was suggested that RCM process with BM might be a suitable process for shipboard sewage treatment, maintenance of useful microorganisms and creating special environment as the SDC tank is circulating in the non-biodegradable organics sludge generated during the wastewater treatment, thus reducing the amount of sludge generated. Therefore, the RCM process does not require additional equipment to strengthen it to meet the marine pollution standards.

Influence of Effluent from a Sludge Carbonization Facility on Wastewater Treatability (슬러지탄화공정수 연계처리가 하수처리효율에 미치는 영향)

  • Han, Joo Eun;Park, Soo-Hyung;Lee, Wontae
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.27 no.1
    • /
    • pp.57-64
    • /
    • 2019
  • We investigated influence of connected influent on the treatability of a wastewater treatment plant (WWTP), recently accepting effluent from a sludge carbonization facility. Based upon the pollutant loading rates (kg/d) of each connected influent, food waste leachate and livestock wastewater contributed to high BOD and COD loadings, while sludge carbonization facility effluent certainly contributed to T-N and $NH_3-N$ loadings. The nitrification rate in aerobic tank decreased to 55% with the carbonization facility effluent entering to the WWTP, while it was 89% with no carbonization facility effluent entering. The sludge carbonization facility effluent may need to be pretreated to reduce T-N and $NH_3-N$ loadings before entering to the WWTP for further treatment.

Analysis of Efficiencies in pro environmental constructed Wetlands for Treating sewage treatment effluent (친환경 인공습지 조성을 통한 하수처리 방류수 재처리 효과분석)

  • Lim, Gun Muk;Park, So Mi;Ha, Eun Jung;Lee, Jong Jin
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.220-220
    • /
    • 2020
  • 영산강수계는 상류에 4개의 농업용 댐이 위치하여 환경대응용수 확보 및 하천유지유량이 절대적으로 부족하고, 갈수기 하천 유량의 약 67 %가 광주 제 1, 2 하수처리장 방류수가 차지하고 있어 하천의 수질과 수생태계를 위협하고 있다. 이에 최근에는 오염된 하천의 건강성을 회복하기 위한 방법으로 수생태계의 정화능력을 활용한 인공습지가 각광받고 있다. 영산강 유역에서도 자연의 정화능력을 활용하여 하천 오염원을 저감시키기 위한 사업의 일환으로 2016년 광주 제 2 하수처리장 방류구에 서창오미공원 습지를 조성하였다. 이 습지는 유입량이 적어 정상적 기능이 어려운 기존 습지를 재조성한 것으로 하수처리장 방류수 약 5만 ㎥/day을 습지로 유입시켜 수질정화용 식재식물을 이용하여 하수처리장 방류수 수질을 개선한 사업이다. 2016~2017년 모니터링 결과, 습지 유입 전·후 BOD는 평균 33.5 %, 최대 73.1 % 저감 되었으며, T-P 또한 평균 59.3 %, 최대 91.6 % 저감 되었다. 그러나 습지는 운영기간 경과 시 퇴적물 축적, 고사체로 인한 T-P 용출 등으로 인하여 처리수의 수질이 더 악화될 우려가 있기 때문에 습지 조성 후 지속적인 유지관리와 모니터링이 필요하다. 그 예로 하수처리장 방류수와 비점오염원 처리를 위해 주암호에 조성된 인공습지의 경우, 2001년 준공 후 지속적인 관리 및 모니터링을 통하여 약 17년이 지난 2018년에도 BOD 49.3 % T-N 65.1 %, T-P 19.2 % 로 저감되어 오염원 및 영양염류 제거에 큰 효과가 있는 것으로 나타났다. 따라서 본 조사에서는 서창오미공원과 주암호 인공습지 운영 결과를 토대로 습지 모니터링의 중요성과 적정 운영 방안을 제시하고자 하며, 영산강 하천의 점·비점오염원 저감을 위한 신규 인공습지 조성 사업에 기초자료로 활용하고자 한다.

  • PDF

A study on pollutants removal characteristics of domestic riverbed filtration and riverbank filtration intake facilities (국내 복류수 및 강변여과수 취수시설의 오염물질 제거특성에 관한 연구)

  • Chan-woo Jeong;Sun-ick Lee;Sung-woo Shin;Chang-hyun Song;Bu-geun Jo;Jae-won Choi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.37 no.5
    • /
    • pp.281-288
    • /
    • 2023
  • This study was performed to evaluate the pollutants removal characteristics of two types of RBFs(Riverbank filtration, Riverbed filtration) intake facilities installed in Nakdong River and in Hwang River respectively. The capacity of each RBF is 45,000 m3/d for riverbank filtration intake facility and 3,500 m3/d for riverbed filtration intake facility. According to data collected in the riverbank filtration site, removal rate of each pollutant was about BOD(Biochemical Oxygen Demand) 52%, TOC(Total Organic Carbon) 57%, SS(Suspended Solids) 44%, Total coliforms 99% correspondingly. Furthermore, Microcystins(-LR,-YR,-RR) were not found in riverbank filtered water compared to surface water in Nakdong River. DOC(Dissolved Organic Carbon) and Humics which are precursors of disinfection byproduct were also reported to be removed about 59% for DOC, 65% for Humics. Based on data analysis in riverbed filtration site in Hwang River, removal rate of each contaminant reaches to BOD 33.3%, TOC 38.5%, SS 38.9%, DOC 22.2%, UV254 21.2%, Total coliforms 73.8% respectively. Additionally, microplastics were also inspected that there was no obvious removal rate in riverbed filtered water compared to surface water in Hwang River.

Treatment of Refractory Dye Wastewater Using AOPs (고도산화공정(AOPs)을 이용한 난분해성 염색폐수 처리)

  • Kim, Jong-Oh;Lee, Kwon-Ki;Jung, Jong-Tae;Kim, Young-Noh
    • Journal of the Korean GEO-environmental Society
    • /
    • v.7 no.3
    • /
    • pp.21-29
    • /
    • 2006
  • The treatment performance of ozonation and three types of advanced oxidation processes (AOPs) such as $O_3/H_2O_2$, $O_3/UV$, $O_3/H_2O_2/UV$ was experimentally investigated for the treatment of refractory synthetic dye wastewater. The removal efficiency of $COD_{cr}$, color and biodegradability ($BOD_5/COD_{cr}$) were relatively evaluated in each treatment unit with simulated dye wastewater. Optimal operational conditions of pH, temperature, dosage and circulation flow rate were also investigated. All suggested processes revealed an effectiveness for the removal of color within a short operational time, moreover, $O_3/H_2O_2/UV$ process showed the highest $COD_{cr}$ removal and biodegradability enhancement among proposed oxidation process.

  • PDF

Protozoa Structure of Anaerobic/Anoxic/Oxic Process. (혐기/무산소/호기공법의 원생동물 군집구조)

  • 이찬형;문경숙
    • Microbiology and Biotechnology Letters
    • /
    • v.31 no.3
    • /
    • pp.264-270
    • /
    • 2003
  • A quantitative survey of the protozoa microfauna at bioreactor of advanced sewage treatment plant was carried out during a period of 11 months. In this study, 32 genera were identified, including 17 ciliates. The abundance of the important protozoa were compared with the operating parameters and water quality of the effluent of the plant using statistical procedure. Statistical analysis revealed a relationship between the abundance of some genera and removal rate. In particular, correlation analysis on the quality of effluent and protozoa indicated that Lepadella may be used as the bioindicator of TP removal and Trochilia, Entosiphon, Colepus may be used as the bioindicator of TN removal when water temperature was below $20^{\circ}C$.