• Title/Summary/Keyword: BOD/COD removal

Search Result 291, Processing Time 0.02 seconds

Application of SWMM for Management of the Non-point Source in Urban Area -Case Study on the Pohang City- (도시지역 비점오염원 관리를 위한 SWMM의 적용 -포항시를 대상으로-)

  • Lee, Jae-Yong;Jang, Seong-Ho;Park, Jin-Sik
    • Journal of Environmental Health Sciences
    • /
    • v.34 no.3
    • /
    • pp.247-254
    • /
    • 2008
  • Non-point source pollution that originates from surface applied chemicals in either liquid or solid form is a part of urban activities and it appears in the surface runoff caused by rainfall. This study investigates the characteristics of non point source pollution in relation to storm events and the first washing effect in the Study area, which is comprised of different land use types. Then, a Best Management Practices (BMP) model, for urban areas, is applied with the Storm water Management Model (SWMM) Windows Interface which was developed by the EPA in the USA. During the storm event analysis of the hydrographic and pollutographic data showed that the peak of pollutants concentration was within the peak flow, 30 to 60 minute into the storm event in the Study area. The results of simulation using SWMM Windows Interface, Structure Techniques as applied in the study were highly efficient for removal of pollutants. Predicted removal efficiency was 26.0% for SS, 22.1 for BOD, 24.1% for COD, 20.6% for T-N, and 21.6% for T-P, respectively.

Improvement of the Biodegradability of Polyvinyl Alcohol by Radiation Treatment (방사선 처리에 의한 폴리비닐 알콜의 생분해도 개선)

  • Jung, Jinho;Park, Nam-Young;Jo, Hun-Je;Lee, Sun-Mi;Kim, Jeong-Gyu
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.3
    • /
    • pp.241-244
    • /
    • 2004
  • Radiation treatment with gamma-rays and electron-beams was used to remove polyvinyl alcohol(PVA), one of the main components of dyeing wastewater. PVA was effectively decomposed by radiation treatment, thus the removal was near 100 % at an initial PVA concentration of 44 mg/L. However, total organic carbon(TOC) removal was less than 5 % due to lower transformation of PVA to $CO_2$. This directly indicates the radiation treatment alone is not appropriate for the complete decomposition of PVA. In this sense, the improvement of biodegradability($BOD_5/COD$) of PVA by radiation treatment was studied. Both gamma-ray and electron-beam treatments significantly increased the biodegradability of PVA by transforming non-biodegradable PVA to biodegradable by-products. This suggests radiation treatment, especially electron-beam treatment that showed better improvement of biodegradability, can be used as a pre-treatment of biological degradation process of PVA.

Unit Mass Estimation and Analysis from Textile Spinning/Weaving Manufacturing Facility Nearby Nakdong River Basin (낙동강 수계에서 제사방적제조 업체에 대한 공정별 원단위산정 및 분석)

  • Lee, Hongshin;Son, Gontae;Gu, Jungeun;Konboonraksa T.;Lee, Hongtae;Lee, Seunghwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.5
    • /
    • pp.541-550
    • /
    • 2008
  • In this investigative study, the unit mass discharge for the major water quality parameters such as flowrate, SS, BOD, CODmn, CODcr, TN, TP from textile spinning/weaving industry nearby Nakdong river basin was estimated. To represent the respective industries, three companies from hundreds of textile spinning/weaving industries located in Nakdong river basin was carefully selected based on its manufacturing goods, flowrate and location for the estimation of unit mass discharge based on unit operation and process. There was a drastic decrease of unit mass discharge estimation between influents and effluents of water quality parameters, which represents the removal capacity of wastewater treatment plant. With the advent of new regulation on the imposed payment proportional to the total amount of pollutants discharge into the water body, the concept of cleaner production technology should be employed in the unit operation/process in wastewater treatment plant as well as textile manufacturing procedure to minimize the levy on the pollutants discharge. Unit mass discharge estimations of unit process (estimated in this study) in major water quality parameters (SS, BOD, COD, TN and TP) based on land were similar to those of composite process (estimated by National Institute of Environmental Research). But the unit mass discharge estimations of unit process in BOD and CODmn based on total sale were much higher than those of composite one while in SS, TN and TP similar to each other. For the detailed estimation of the imposed payment, unit mass estimation based on unit process should be further emphasized.

Analysis on the Actual Conditions of Wastewater Treatment Facilities in Chungcheongnam-do Province Industrial Complexes (충청남도 산업단지의 오·폐수처리실태 분석)

  • Lim, Bong-Su;Kim, Do-Young;Yi, Sang-Jin;Oh, Hye-Jung
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.6
    • /
    • pp.850-862
    • /
    • 2007
  • This study was carried out to survey the actual conditions of wastewater treatment facilities to obtain basic data for the management of wastewater from industrial complexes in Chungcheongnam-do province. Wastewater production flow per site area by watersheds was $49.2m^3/km^2/d$ for Sapgyoho, $8.1m^3/km^2/d$ for Anseongcheon, $5.7m^3/km^2/d$ for Seohae, and $2.9m^3/km^2/d$ for Geumgang. Sapgyoho showed 75% of the total production flow, which was the highest value, Geumgang showed 4% of total flow, which was the lowest value. Average total extra rate as production flow/capacity flow in the wastewater treatment facilities for industrial complex is 49%. Considering by watersheds, the extra rates of Seohae, Geumgang, Anseongcheon, and Sapgyoho, are 73%, 65%, 62%, and 33% respectively. This means that the design of capacity flow in wastewater treatment facilities was too large. Effluent concentration of wastewater treatment facilities did not exceed discharge limit mostly. The removal efficiency rate for water quality item was 90% in BOD, 70% in COD, 80% in SS, 30 to 80% in TN, and 20 to 90% in TP, so the organic removal was good, but the nutrient removal was low and interval of variation was high. The removal efficiency rate of the agricultural was industrial complexes is lower than the national and local complexes. The construction cost of the wastewater treatment facilities in Chungcheongnam-do was $1,756Won\;per\;m^3$, treatment cost was $189Won\;per\;m^3$, and they were about two times and 1.2 times higher than the nation-wide cost, respectively. The treatment cost consists of 39% for man power, 21% for chemical, 16% for power, 11% for sludge treatment, and 13% for others.

Enhancement of Discfilter Removal Efficiency for Small-scale Wastewater Reclamation (소규모 하수 재이용을 위한 디스크필터의 처리 효율 증진에 관한 연구)

  • Choi, Nag-Choul;Kim, Bong-Ju;Park, Seong-Yong;Park, Hyeong-U;Lee, Sung-Jae;Park, Cheon-Young
    • Journal of Soil and Groundwater Environment
    • /
    • v.20 no.4
    • /
    • pp.66-72
    • /
    • 2015
  • The aim of this study was to enhance of the Discfilter process (maximum treatment capacity - 500 ton/day) removal efficiency for small-scale wastewater reclamation under various influent wastewater conditions (with / without coagulation process, coagulant content and temperature). The result of chemical resistance test for fiber filter in the Discfilter that weight loss was obtained with 0.535% under pH 3, 0.092% under pH 9 and 0.028% under 10% NaClO. The removal efficiency test of Discfilter process on the with / without coagulation process showed that with coagulation process condition was occurred CODMn of 42.26 ± 0.61, BOD5 of 88.72 ± 0.44, T-P of 84.67 ± 0.72 and SS of 90.58 ± 0.61. The removal efficiency of Discfilter process on the coagulant content (4.5, 5.0 and 5.0 mL/min) and temperature (< 10℃, 10℃~ 20℃ and > 20℃) conditions were increased as coagulant content and temperature increased. This study demonstrated the potential application of Discfilter process for small-scale wastewater reclamation.

Analysis of RCSTP And MWTP Pollutants Treatment Efficiency in Bong-Hwa Gun (봉화군 마을하수도 및 하수처리장의 오염물질 처리 효율 분석)

  • Park, Minsoo;Im, Jiyeol;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.19 no.1
    • /
    • pp.69-79
    • /
    • 2017
  • Protected area of water for supply source is located mostly of rural area in Korea. Normally, sewage treatment system is poor to manage in rural, because low population and density. Rural area need sewage treatment system to supervise supply source of water. In this study, analysis on operation result of 4 RCSTP and MWTP is located at the rural area. Higher concentration of pollutant were inflows to MWTP than RCSTP, and effluent quality standard is satisfaction. However, RCSTP effluent pollutant concentrations was researched higher than MWTP. The organic matter(BOD, COD) were about 5% of a high treatment efficiency to a median. The nutrient(T-N, T-P) were detected Up to high 30%. Also, we analyzed to effect reactor operational parameters on the pollutant treatment efficiency like mixed liquer suspended solid(MLSS), dissolved oxygen(DO) and sludge retention time(SRT). As a result, pollutant treatment efficiency showed fluctuation in accordance with operating condition. Thus, it is necessary to manage the reactor operation condition for management of rural area sewage treatment.

Vertical Flow Zeolite-Filled Reed Bed with Intermittent Feeding for Sewage Treatment (수직 흐름 제올라이트 갈대 여과상에 의한 생활하수 처리)

  • Seo, Jeoung-Yoon
    • KSBB Journal
    • /
    • v.22 no.2
    • /
    • pp.102-108
    • /
    • 2007
  • A sewage was treated using a vertical flow zeolite-filled reed bed. The sewage from the student dormitory of Changwon National University was fed into the reed bed for 10 minutes every 6 hours at the hydraulic load of $314L/m^3{\cdot}$day. The filtering height of the reed bed was 100 em and the zeolite mixture was filled in the reed bed. The mixture consisted of the same volume of two types of zeolite: 0.5$\sim$1 mm and 1$\sim$3 mm in diameter. Annual average removal efficiency was 88 89.9%, $COD_{Cr}$ 86.1 %, $COD_{Mn}$ 81.2%, T-N 34.0%, $NH_4^+$-N 97.3% and T-P 34.6%. T-N of effluent was mostly $NO_3^-$-N and the concentration of $NO_2^-$-N in effluent was lower than 0.1 mg/L. All removal efficiencies did not show a remarkable seasonal change. The ranking of phosphorous fractions fixed to the zeolite in column test was Ca-P > Fe-P > reductant soluble Fe-P > occluded P > saloid P > AI-P at all depths of the filter. All phosphorous fractions except for AI-P reduced at deeper filter layer, while their content ratios increased at deeper filter layer. Organic matter content was the highest at the highest layer (0$\sim$5 cm from the top of the filter) and only small differences were observed at the deeper filter layer than 5 em from the top. Organic matter content increased at all depths of the filter with the operating time.

Sewage Treatment Using a Double Media Reed Constructed Wetland (복층여재 갈대 인공습지에 의한 생활하수 처리)

  • Seo, Jeoung-Yoon
    • Journal of Wetlands Research
    • /
    • v.16 no.4
    • /
    • pp.379-388
    • /
    • 2014
  • A sewage was treated using a serially combined vertical(VFCW) and horizontal flow double media (sand and zeolite for VFCW and sand and waste oyster-shell for HFCW) reed constructed wetland(HFCW) with intermittent feeding (see Fig. 1). The sewage was fed into the reed constructed wetland for 10 minutes every 6 hours at the hydraulic load of $314L/m^2{\cdot}day$. The summarized results were as follows: pH values in the effluent depended very heavily on oyster-shell height filled in the HFCW. They were maintained at less than pH 6.24 when the height of the oyster-shell layer was 200 mm. Influent DO(oxygen demand) values(average 0.19 mg/L) were increased in the VFCW(average 7.65 mg/L) and decreased again in the HFCW(average 6.49 mg/L). They were higher in the winter than in the summer. The OTR(oxygen transfer rate) was $57.15g\;O_2/m^2{\cdot}day$ in the VFCW and $5.65g\;O_2/m^2{\cdot}day$ in the HFCW. The removal efficiency of $NH_4{^+}$-N was 80.17%(6.01 $NH_4{^+}$-N mg/L in the effluent). It was lower than that in the case where only zeolite was filled in the reed constructed wetland. But it was expected that treated sewage effluent using a double media reed constructed wetland with 300 mm zeolite layer could stably meet the Korean treated sewage effluent standard(20 mg T-N/L). Average removal efficiencies were SS 88.09%, BOD 88.12%, $COD_{Cr}$ 83.11%, $COD_{Mn}$ 85.58%, T-N 57.21%, $NH_4{^+}$-N 80.17%, T-P 86.73%. Nearly, The concentration of $NO_3{^-}$-N in the effluent of the VFCW was decreased in that of the HFCW. More than half of T-N in the effluent was $NO_3{^-}$-N(7.92 mg/L) but the concentration of $NO_2{^-}$-N in the effluent was average 0.90 mg/L. The removal efficiencies of T-P were 93.24%, 86.30% and 55.44% at the height of the oyster-shell-filled constructed wetland of 800 mm, 500 mm and 200 mm, respectively and therefore, they were proportional to oyster-shell height filled in the HFCW.

A Study on Removal of Organism and Nitrogen, Phosphorus in Wastewater Treatment Process Using Nitrifier Activated Reactor (질산화균 활성화조를 이용한 하수처리 공정에서의 유기물 및 질소, 인 제거에 관한 연구)

  • Dong, Young-tak;Seo, Dong-whan;Bae, Yu-jin;Park, Ju-seok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.6
    • /
    • pp.727-735
    • /
    • 2007
  • The use of water by cities is increasing owing to industrialization, the concentration of population, and the enhancement of the standard of living. Accordingly, the amount of waste water is also increasing, and the degree of pollution of the water system is rising. In order to solve this problem, it is necessary to remove organisms and suspended particles as well as the products of eutrophication such as nitrates and phosphates. This study developed a high-end treatment engineering solution with maximum efficiency and lower costs by researching and developing a advanced treatment engineering solution with the use of Biosorption. As a result, the study conducted a test with a $50m^3/day$ Pilot Scale Plant by developing treatment engineering so that only the secondary treatment satisfies the standard of water quality and which provided optimal treatment efficiency along with convenient maintenance and management. The removal of organisms, which has to be pursued first for realizing nitrification during the test period, was made in such a way that there would be no oxidation by microorganisms in the reactor while preparing oxygen as an inhibitor for the growth of microorganism in the course of moving toward the primary settling pond. The study introduced microorganisms in the endogeneous respiration stage to perform adhesion, absorption, and filtering by bringing them into contact with the inflowing water with the use of a sludge returning from the secondary settling pond. Also a test was conducted to determine how effective the microorganisms are as an inner source of carbon. The HRT(Hydraulic Retention Time) in the nitrification tank (aerobic tank) could be reduced to two hours or below, and the stable treatment efficiency of the process using the organisms absorbed in the NAR reactor as a source of carbon could be proven. Also, given that the anaerobic condition of the pre-treatment tank becomes basic in the area of phosphate discharge, it was found that there was excellent efficiency for the removal of phosphate when the pre-treatment tank induced the discharge of phosphate and the polishing reactor induced the uptake of phosphate. The removal efficiency was shown to be about 94.4% for $BOD_5$. 90.7% for $COD_{Cr}$ 84.3% for $COD_{Mn}$, 96.0% for SS, 77.3% for TN, and 96.0% for TP.

Protozoa Structure of Anaerobic/Anoxic/Oxic Process. (혐기/무산소/호기공법의 원생동물 군집구조)

  • 이찬형;문경숙
    • Microbiology and Biotechnology Letters
    • /
    • v.31 no.3
    • /
    • pp.264-270
    • /
    • 2003
  • A quantitative survey of the protozoa microfauna at bioreactor of advanced sewage treatment plant was carried out during a period of 11 months. In this study, 32 genera were identified, including 17 ciliates. The abundance of the important protozoa were compared with the operating parameters and water quality of the effluent of the plant using statistical procedure. Statistical analysis revealed a relationship between the abundance of some genera and removal rate. In particular, correlation analysis on the quality of effluent and protozoa indicated that Lepadella may be used as the bioindicator of TP removal and Trochilia, Entosiphon, Colepus may be used as the bioindicator of TN removal when water temperature was below $20^{\circ}C$.