• 제목/요약/키워드: BOD/COD removal

검색결과 291건 처리시간 0.025초

과실 채소중 잔류농약(유기인제)에 관한 연구 (Organophosphorus Insecticide Residues in Fruits and Vegetables)

  • 윤숙자
    • 환경위생공학
    • /
    • 제5권1호
    • /
    • pp.83-92
    • /
    • 1990
  • Adapting two step aeration system to a waste water treatment of W-paper manufactory as Full-Scale Plants, we drew a following conclusion from its practical working. 1. Because BOD removal efficiency was 20% in A-Stage, 90% in B-Stage and total removal efficiency was 97%. It worked treatment plant well and was suitable for effluent water standard as well. Because COD removal efficiency was 42% in A-stage, 71% in B-stage and the total removal efficiency was 94% COD control was possible in effluent water quality. 2. Treatment efficiency according to a load capacity was average 20% in 1.401 BOD kg/m3/d load of A-Stage and average 90% in 0.273 BOD kg/$\textrm {m}^3$ / d load of B-Stage. 3. Treatment efficiency according to a ratio of F/M was 2.657--5.024 kg BOD/kg MLSS/d in A-Stage and BOD removal efficiency was 16-261 in the same stage. The ratio of F/M was 0.068-0.094 kg BOD /kg MLSS/d and BOD removal efficiency ratio was 85-94%. Therefore treatment efficiency could be kept stably and volume of aeration tank could be reduced wholly. 4. Treatment efficiency according to MLSS appeared BOD 20%. COD 42%, in A-Stage and removal efficiency appeared BOD 90%, COD 71% in B-Stage. They were suitable for plan condition. 5. Because of working of complemented treatment plant by AB-Process. 20,000,000 Won a month was saved than the ordinary working cost. Therefore, it was assumed that invested cost could be recollected in 19 months or so consequently.

  • PDF

오염하천 정화를 위한 호기성 인공습지의 운영인자 평가 (Parameter Estimation of the Aerated Wetland for the Performance of the Polluted Stream Treatment)

  • 김둘선;이동근
    • 청정기술
    • /
    • 제25권4호
    • /
    • pp.302-310
    • /
    • 2019
  • 호기조와 혐기/무산소조를 직렬로 연결한 인공습지를 이용하여 크게 오염된 하천수를 처리하였다. 호기조는 자연 공기 배출 시스템을 통하여 공기가 연속적으로 공급되어 호기성 상태가 유지되었다. 인공습지의 성능에 영향을 미치는 최적의 영향인자를 조사하기 위하여 체류시간을 다르게 한 5개의 파일럿 플랜트를 사용하였다. 호기조에서 BOD (biochemical oxygen demand)와 COD (chemical oxygen demand)의 제거율은 1차 반응 속도식을 나타내었고, COD 제거 속도 상수는 BOD보다 약간 낮았다. 온도 의존성은 COD (θ = 1.0079)와 BOD (θ = 1.0083)제거에 대한 값이 거의 동일했으나 T-N 제거의 온도 의존성(θN)은 1.0189로 다소 높게 나타났다. SS제거율은 98%로 높았고 수력학적 부하 속도(Q/A)가 증가함에 따라 제거 효율이 증가하는 경향을 보였다. 혐기/무산소조에서 BOD와 COD 제거의 주요 메커니즘은 호기조와 완전히 다르게 나타났다. 혐기/무산소조에서 COD와 COD는 생물학적 탈질을 위한 탄소원으로 공급되었고 T-P는 혐기/무산소조 내의 orthophosphate와 자갈 사이의 양이온 교환에 의해 제거되는 것으로 조사되었다. 인공습지는 여과된 고형물에 의해 막힘 없이 성공적으로 운영되었고 고형물들은 매우 빠르게 연속적으로 분해되었다.

유동상 담체를 이용한 Loop Reactor에서 유기물 및 질소, 인 제거 (The Removal of Organics, Nitrogen and Phosphorus in Loop Reactor Using Fluidized Media)

  • 선용호
    • KSBB Journal
    • /
    • 제24권4호
    • /
    • pp.353-360
    • /
    • 2009
  • 본 연구에서는 혐기조 및 무산소조, 호기조로 구성된 상향류식 고정상 담체 반응장치와 호기조로 고정상 담체 대신에 유동상 담체를 사용한 Loop Reactor로 이루어진 장치에서 생활하수를 이용하여 성능실험을 수행한 후 HRT에 따른 유기물 및 T-N, T-P 등 오염물질의 제거 특성을 비교 분석하였다. 두 반응기 모두 평균 BOD 제거율과 SS 제거율은 HRT가 증가함에 따라 증가하다가 HRT 16 h 이상에서는 일정한 수치를 나타내고 있으며 HRT 16 h에서 고정상 담체 반응기와 Loop Reactor의 평균 BOD 제거율은 각각 86.6%, 90.9%이었으며 평균 SS 제거율은 각각 78.0%, 88.2%로 Loop Reactor의 경우가 각각 4.3%, 10.2%의 더 높은 BOD와 SS 제거율을 나타내었다. 또한 평균 $COD_{Cr}$, 제거율 및 평균 $COD_{Mn}$ 제거율은 BOD와 SS 제거율과 마찬가지로 HRT가 증가함에 따라 증가하다가 HRT 16 h에서 일정한 수치를 나타내고 있으며 고정상 담체 반응기와 Loop Reactor의 평균 $COD_{Cr}$, 제거율은 각각 63.5%, 75.2%이었으며 평균 $COD_{Mn}$ 제거율은 각각 60.7%, 73.6%로 Loop Reactor의 경우가 11.7%, 12.9% 더 높은 제거율을 나타내었다. 반면에 평균 T-N 제거율 및 T-P 제거율은 두 반응기 모두 HRT가 증가함에 따라 제거율은 계속 증가하는 양상을 보여주고 있으며 HRT 16 h에서 Loop Reactor의 경우 평균 T-N 제거율 및 평균 T-P 제거율은 각각 33.6%, 54.5%로 고정상 담체 반응기보다 14.1%, 10.8%의 더 높은 제거율을 나타내었다. 이상의 결과에서 Loop Reactor가 성능이 훨씬 더 우수하였으며 최적 HRT는 16 h임을 알 수 있었다.

오염처리장의 처리효율 개선연구 (A Study on Improvement of Sewage Treatment System)

  • 성일화
    • 한국환경보건학회지
    • /
    • 제19권3호
    • /
    • pp.36-40
    • /
    • 1993
  • The objective of this research was to retrofit an on-site sewage treatment system suitable to current situation of Korea to reduce the pollution loading and preserve the invaluable water resources. Operation at the F/M ratio of 0.1 kg. BOD/kg MLSS day showed 87.1% BOD removal efficiency and 84.5% COD removal efficiency, and its effluent concentration was 6.4 mg/l as BOD and 21.7 mg/l as COD. Average removal of total nitrogen showed high removal efficiency of 80%.

  • PDF

Treatability Study on the SepticTAnk Sludges

  • Byung Soo Yang
    • 수산해양기술연구
    • /
    • 제17권1호
    • /
    • pp.41-47
    • /
    • 1981
  • The characteristics of septic tank sludges were investigated and the kinetic coefficients in the aerobic biodegradation were evaluated from bach treatability tests. Using an unbiased statistical method, the estimated values, k (substrate removal rate coefficient) =0. 0175hr-1 at 17\ulcornerC, K. (Michaelis Menten constant) = 248mg/ e, a (cell yield coefficient)=0.625, and Kd (cell decay coefficient:' =0. 00192hr-1 were obtained based on biodegradable COD(mg/ \ulcorner) and volatile suspended solids(mg/\ulcorner). The relationship between COD and BOD, COD (mg/\ulcorner) =2. 1 BOD(mg/\ulcorner) +250, also was established for the septic tank sludges. Dilution was inevitable for the grit removal because of the high viscosity of the sludges. An aerobic activated sludge process rather than anaerobic processes was recommended for the removal of soluble organics after the removal of grit and suspended solids. A multi-stage activated sludge process was adapted for this highly concentrated and not easily-degradable waste. It was estimated that a four-stage activated sludge process would require 40 hours retention time compared to 92 hours for a single-stage process, 52 hours for a double-stage process, and 46 hours for a three stage process in order to achieve an effluent quality of 84mg/ e COD( 40mg/ e BOD) with about 4, OOOmg/ \ulcorner MLSS from an influent quality of I, 500mg/ t COD(714mg/.e BOD), while multi-stages beyond four stage would not save the required retention time significantly.

  • PDF

침지형 membrane을 이용한 생활오수처리 (Municipal Wastewater Treatment by Submerged Membrane Process)

  • 김광남;정순형;정우영;윤용수
    • 환경위생공학
    • /
    • 제14권2호
    • /
    • pp.105-112
    • /
    • 1999
  • The removal characteristic of BOD, COD,T-N, and T-P was investigated in municipal wastewater treatment with anoxic and membrane submerged aerobic reactor. It was found that BOD and COD removal rate were obtained 90% and 92%, respectively, for 90 days operation. BOD and COD loading rate did not affect to the removal efficiency because MLSS concentration in aerobic tank was highly maintained.In the case of first reactor operated with anoxic and second reactor operated as aerobic, T-N, T-P removal rate were obtained 93% and 99% respectively.It was shown that removal efficiency could be maintained stable due to the complete removal of SS and sludge production decreased with increasing of sludge retention time.

  • PDF

물리, 화학 및 생물학적 방법에 의한 안료폐수의 적정처리 및 재이용 가능성 평가 (The Appropriate Treatment and Reuse Ability Assessment of Pigment Wastewater by Physical, Chemical, and Biological Process)

  • 정종식;옥치상
    • 한국환경과학회지
    • /
    • 제7권1호
    • /
    • pp.81-88
    • /
    • 1998
  • This study was conducted to assess the characteristics of plgment wastewater and the removal rates of appropriate treatment by physical, chemical and biological Process, and the possibility of reuse for effluent. Based on the results, the wastewater qualities of pigment were pH 5.1$\pm$3.4, temperature 43.0$\pm$ 15.$0^{\circ}C$, BOD 1,431.4$\pm$589.6mg/l, COD 2,282.8$\pm$466.5mg/l, turbidity 1,340$\pm$820NTU, color 243.0$\pm$147.0unit, Pb 36.5$\pm$9.5mg/l and $Cr^+6$ 10.3$\pm$ 1.3mg/l, respectively. The removal rates of adsorption by activated carbon and filter process were BOD 40.6% , COD 57.0% , turbidity 89.6%, color 87.2%, Pb 86.0% and $Cr^+6$ 10.6%, respectively. And the removal rates of reduction, neutralization, coagulation and aP floatation process were BOD 18.2%, COD 24.3%, turbidity 74.3%, color 56.7%, Pb 68.6% and $Cr^+6$ 97.8%, respectively. The removal rates of activated sludge process were BOD 95.9%, COD 86.0%, turbidity 27.8%, color 25. 2%. Pb 26.9% and $Cr^+6$ 50.0% , respectively. The total removal rates of treatment by physical, chemical and biological process were BOD 98.0% , COD 95.4%, turbidity 98.1%, color 95.8%, Pb 97.0% and $Cr^+6$ 99.0%, respectively. According to the test results for possibility of reuse with coagulation-adsorption by activated carbon process of effluent, COD was higher than that of raw water and others were similar to that of raw water thus, it Is considered to be reused.

  • PDF

제올라이트 칼럼에 의한 인공생활하수의 COD 및 BOD 제거에 관한 연구 (COD and BOD Removal of Artificial Municipal Wastewater by a Column filled with Zeolite)

  • 서정윤
    • 한국습지학회지
    • /
    • 제3권1호
    • /
    • pp.75-89
    • /
    • 2001
  • Constructed wetlands were typically cost less to build and operate, and require less energy than standard mechanical treatment technology but they have similar performance to centralized wastewater treatment plants. Therefore, they were constructed especially many in rural areas, where are small villages but not industries. Accordingly, plantless column tests were performed to investigate the possibility on using zeolite as a filter medium of constructed wetland for the wastewater treatment. $COD_{cr}$ removal efficiency was 94.63% at hydraulic load $314L/m^2{\cdot}d$ and filtering hight 100cm filled with a zeolite mixture. This zeolite mixture consisted of 1 : 1 by volume of a zeolite in the diameter range of 0.5 to 1mm to a zeolite in the diameter range of 1 to 3mm. According, hydraulic load $314L/m^2{\cdot}d$ was considered as optimal. Three zeolite mixture were used to determine the optimal mixing ratio by volume of a zeolite(A) in the diameter range of 0.5 to 1mm to a zeolite(B) in the diameter range of 1 to 3mm diameter. 1 : 3, 1 : 1 and only B in A to B by volume were tested at hydraulic load $314L/m^2{\cdot}d$ and filtering hight 100cm. $COD_{cr}$ removal efficiency was more than 89% at mixing ratios of 1 : 3 and 1 : 1 in A to B. Removal efficiency was lower at the column filled with only B. Removal efficiency was better at filter medium filled with mixing ratio 1 : 1 in A to B than with the other mixing ratios. Thus, it was found that the mixture of mixing ratio 1 : 1 in A to B was appropriate for filter medium of constructed wetland. Removal efficiency was higher in down-flow than in up-flow, and $COD_{cr}$ and BOD were removed best in 20cm filter height near feeding area.

  • PDF

Changes in BOD, COD, Chlorophyll-a and Solids in Aquaculture Effluent with Various Chemical Treatments

  • Park, Jeonghwan;Daniels, Harry V.
    • 한국해양생명과학회지
    • /
    • 제2권2호
    • /
    • pp.49-55
    • /
    • 2017
  • Four chemical treatments with hydrogen peroxide (H2O2), copper sulfate (CuSO4), potassium permanganate (KMnO4) and chlorine (Cl2) were applied to the effluent pond water of a hybrid striped bass saltwater recirculating aquaculture system to compare their oxidation power. Four chemicals were applied at concentrations of 0 (control), 1, 5, 10 and 20 mg/l. An additional concentration of 40 mg/l was included in the chlorine treatment. Water samples from four hybrid striped bass ponds were tested with KMnO4 and Cl2. H2O2 did not reduce any of BOD, COD and chlorophyll-a, and copper sulfate was only effective on chlorophyll-a for the effluent pond. Removal efficiencies for chlorophyll-a by copper sulfate were 19.2%, 37.5%, 54.2% and 74.1% dose-dependently. Potassium permanganate effectively removed the BOD, COD and chlorophyll-a. The COD removal rates in four fish ponds varied from 15.9% to 31.6% at the concentration of 10 mg/l. Interestingly, Cl2 did not reduce the BOD and COD at all, but the BOD and COD instead increased drastically with increasing the Cl2 concentration. The pond water with the highest initial BOD and COD values among the fish ponds tested increased by 350% in the BOD and 150% in the COD at 20 mg/l. Furthermore, Cl2 did not significantly reduce any types of solid matter in this study, while KMnO4 seemed to reduce some extent volatile dissolved solid in the fish pond.

충남지역 마을하수의 발생 및 처리현황 (Generation and Current Treatment Status of Sewage at the Rural Village in Chungnam Province)

  • 강방훈;김진호;최철만
    • 한국환경농학회지
    • /
    • 제27권1호
    • /
    • pp.44-49
    • /
    • 2008
  • 본 연구는 농촌마을에서 발생하는 마을하수의 수질현황과 마을하수 처리시설에 대한 관리 현황 및 정확한 실태를 파악하고 처리효율을 조사하여 마을하수의 효율적인 관리방안을 모색하며, 농촌마을 하수정비 사업과 농촌지역 하수정책 수립의 활용에 대한 기초자료로서 제공하고자 실시하였는데, 그 결과는 다음과 같다. 1. 마을하수 처리시설에 대한 각 지역별 유입수 수질 분석 결과, 아산시 지역에서의 유입수 BOD와 COD의 평균 농도는 각각 29.0 mg/L와 19.1 mg/L였고, 부여군 지역은 BOD 16.7 mg/L, COD 16.3 mg/L, 공주시 지역은 BOD 18.8 mg/L, COD 15.3 mg/L로 조사되어 아산시 지역에서 유입수의 농도가 가장 높았으나 일반적인 도시하수의 유입수 농도에 비해 매우 낮게 조사되었다. 2. 오염부하량별 원단위는 BOD $3.3{\sim}4.9$ gpcd, COD $3.2{\sim}11.3$ gpcd, T-N $1.5{\sim}4.6$ gpcd, T-P $0.3{\sim}0.5$ gpcd 로 조사되어 도시하수의 오염부하량 원단위 결과보다는 상당히 낮게 조사되었다. 3. 마을하수 처리시설의 처리공법별 제거효율은 고효율 합병정화조와 토양피복형 접촉산화법에서는 특히 BOD와 SS의 제거효율이 높았으며, 접촉산화법의 경우는 다른 처리공법에 비해 조금 낮게 조사되었다.