• Title/Summary/Keyword: BLUETOOTH

Search Result 1,541, Processing Time 0.025 seconds

Development of Personal Hypertension Management System Using PDA (PDA를 이용한 개인 심혈관리 시스템 개발)

  • Kwon, Seok-Young;Kwon, Mann-Jun;Park, Kyoung-Soon;Chun, Myung-Geun;Cha, Eun-Jong
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.17 no.5
    • /
    • pp.718-723
    • /
    • 2007
  • In this paper, we developed a personal hypertension management system (PHMS) having self-diagnosis function with PDA. The developed PHMS consists of five modules such as a personal information management, a life management, a food management, a sickness management, and network management modules. The personal information management module offers physical and fatness information as well as personal information. The life management module gives exercise and body mass index. The food management module includes caloric intake and the sickness management module renders a personal blood pressure and a subjective symptom. Finally, wireless networks are implemented for the network management. From these, it is possible to make a self diagnosis and be examined and treated remotely by sending the stored blood pressure related information to a medical doctor.

Immediate Effects of Posteroanterior Cervical Mobilization on Pressure Pain Threshold and Gait Parameters in Patients with Chronic Neck Pain: A Pilot Study

  • Choi, Taeseok;Moon, Okkon;Choi, Wansuk;Heo, Seoyoon;Lee, Sangbin
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.10 no.4
    • /
    • pp.1914-1920
    • /
    • 2019
  • Background: Mobilization and cranio-cervical flexion exercise has been reported in reducing pain from cervical part and improving its motor function; also, has been represented that alleviate of neck pain and recover of neck muscles improve the normal gait performance. However, few studies have identified the effects of mobilization and exercise on pain and gait parameters with preceding issues. Objective: To examine the effects or changes of pressure pain threshold (PPT) and gait parameters in patients with chronic neck pain. Design: Cross-Sectional Clinical Trials Methods: Twenty patients with the history of neck pain (>3 months) performed the cervical mobilization and cranio-cervical flexion exercise. Gait parameters were assessed with wireless device and collected data were transmitted to the personal computer via Bluetooth. The PPT was measured posteroanterior direction at the prone position and the mean of subsequent three PPT measurements was used for the final analysis. Results: Both cervical central posteroanterior mobilization (CCPAM) (p<.000) and sling-based cranio-cervical flexion exercise (SBCCFE) (p<.000) group showed a significant increase in the PPT and the gait parameters, cadence (p<.023), was significantly increased in the CCPAM group, however slightly increased in the SBCCFE group. The comparison between the CCPAM and the SBCCFE groups after treatment did not show significant differences for the score on the PPT and gait parameters. Conclusions: This study suggests that CCPAM and SBCCFE increase PPT, cadence, and gait speed.

Design of Electrostatic Monitoring System (정전기 모니터링 시스템 설계)

  • Kim, Kang-Chul;Byon, Chi-Nam;Lim, Chang-Gyoon;Han, Seok-Bung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.11
    • /
    • pp.2069-2076
    • /
    • 2008
  • In this paper, we develop an electrostatic monitoring system which is composed of an electrostatic prediction system and a warning message transmission system. The electrostatic prediction system in a factory receives the value of electrostatic charge from the electrostatic sensor and predicts the next value by using past data and sends the value to the warning message transmission system through the bluetooth communication. The warning message transmission system gets a warning signal and transmits the warning message to the worker's cellphone through a commercial SMS web by a socket program running on Windows PC in a control room. We propose electrostatic forecasting algorithms based on LSR(least square regression) using weight factors in an electrostatic prediction system. Simulation results show that the algorithm with dynamically variable weight factors is best with 64.69V standard deviation and a warning message transmitted by the warning message transmission system is displayed on cellphone after about 5 seconds.

Proposal for a Peer Decentralized Identity System Using Short-Range Wireless Communications (단거리 무선 통신을 이용한 개인 간 분산 신원증명 시스템 제안)

  • Yeo, Kiho;Park, Keundug;Youm, Heung Youl
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.31 no.5
    • /
    • pp.959-972
    • /
    • 2021
  • Decentralized Identity is based on the concept of self-sovereign identity, in which holders manage and provide their own credentials. However, a procedure is required to obtain credentials from issuers, and there is a risk of mess personal information leaking due to negligence of the issuers. In this paper, we propose a peer decentralized identity system based on Peer DID technology that allows only participants to verify their identity in 1:1 or 1:N small groups by matching the holder with the issuer. It is directly connected to a mobile device using short-range wireless communications such as bluetooth, and the holders create and provide their own credentials in person to the other party, thus fully realizing the self-sovereignty identity. The proposed system can simplify the identification process, improve security and privacy, and reduce costs. Furthermore, an extended architecture is possible to connect the proposed system and the distributed ledger to identify users in other domains. In the future, based on various technologies, it is also necessary to expand research on identity systems that can be utilized for human-to-thing and things-to-things authentication.

A Study on the Stabilization of a System for Big Data Transmission of Intelligent Ventilation Window based on Sensor and MCU (센서 및 MCU기반 지능형 환기창 빅데이터전송용 시스템 안정화에 관한 연구)

  • Ryoo, Hee-Soo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.3
    • /
    • pp.551-558
    • /
    • 2021
  • In this paper, we made the integrated intelligent air ventilation of the actuator module that can be remotely controlled based on IoT and sensors. we implemented a ventilation window system by configuring an algorithm design and a driving circuit to control the operation of the actuator to open and close the ventilation port based on a predetermined number of data that detects indoor gas/CO2/humidity temperature and outdoor fine dust related indoor/outdoor environment. It is difficult to store, manage, and analyze data due to the large number of sensors and conditions for the transmission data of indoor air circulation module. The remote monitoring and remote wireless control screens were constructed to automate the separation and operation conditions by extracting and managing the state. We apply MQTT to enhance big data transmission and construct the system using Rocket MQ to ensure safe transmission of operational big data against system errors.

Design and Implementation of Gas Leakage Alarm IoT System for Safety Helmet (안전모 장착용 가스 누출 경보 IoT 시스템 설계 및 구현)

  • Ju, Yong-Min;Lee, Hyo-Seung;Oh, Jae-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.6
    • /
    • pp.1411-1416
    • /
    • 2018
  • Currently, most of the industrial areas like chemistry, manufacturing, shipbuilding, and steel, perform the work related to gas, and the staffs who are in charge of this work have a risk of suffocation without cognizing incidents like gas leak. For example, when the nitrogen gas leaked in 2015 at Paju, two people were killed and four people were injured. In 2018 at Pohang, four workers were suffocated to death from nitrogen gas. In order to solve this problem, this study realized the system in which workers could immediately cognize the gas leak and also deliver the situation to the staff in charge of safety at the same time, by installing the IoT device composed of gas sensor and communication module on the safety helmet that should be worn by field workers. This study is expected to be able to reduce the casualties caused by gas leak in industrial sites.

Data Error Compensation Estimation Technology for Providing High Quality Contents in IoT Environment (IoT 환경에서 고품질 콘텐츠 제공을 위한 데이터 오류 보상 추정 기술)

  • Kim, Jeong Su
    • The Journal of the Convergence on Culture Technology
    • /
    • v.5 no.3
    • /
    • pp.333-338
    • /
    • 2019
  • Cultural contents are the most important factor in high speed and high quality data communication. High-quality content includes VR and AR technology, and a variety of high-quality content can be streamed over wireless mobile phones via smartphones. In addition, network and wired/wireless communication are inevitably required in an Internet of Things (IoT) environment in which things are connected to a wireless Internet. IoT is used in various network technologies such as 4G, 5G mobile communication, WIFI wireless LAN, Bluetooth and so on. It is a technology that can use the connection between things anytime, anywhere, and can be achieved in a wireless mobile communication environment. Therefore, in this paper, we study data error compensation estimation method which can reduce data error based on mobile communication channel environment analysis so that high quality contents can be serviced even in high speed mobile environment.

Development of Unmanned Video Recording System using Mobile (모바일을 이용한 무인 영상 녹화 시스템 개발)

  • Ahn, Byeongtae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.6
    • /
    • pp.254-260
    • /
    • 2019
  • Recently, a self-camera that generates and distributes a large amount of moving images has been rapidly increasing due to the appearance of SNS such as Facebook, Instagram, and Tweet using mobile. In particular, the amount of SNS connections using mobile phones is significantly increasing in terms of usage, number of connections, and usage time. However, the use of a self-recording system using a smartphone by itself is extremely limited not only in terms of usage but also in frequency of use. In addition, the conventional unattended recording system is a very expensive system that automatically records and tracks an object to be photographed using an infrared signal. Therefore, this paper developed a low cost unmanned recording system using mobile phone. The system consists of a commercial mobile camera, a servomotor for moving the camera from side to side, a microcontroller for controlling the motor, and a commercial wireless Bluetooth earset for video audio input. And it is an unmanned automation system using mobile, and anyone can record image by self image tracking.

Implementation of Maritime Telemedicine System Using Android (안드로이드를 이용한 해양원격진료시스템 구현)

  • Lee, Ho-Tae;Kim, Byoung-Chul
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.6
    • /
    • pp.221-228
    • /
    • 2018
  • The purpose of this study is to design and implement a maritime telemedicine system to provide the best medical service for patients who rescue and happens in sailing ship. For this purpose, INMARSAT and MVAST, which are necessary communication channels for maritime telemedicine, were examined and diversity in maritime communication path was suggested. It was implemented to enable maritime telemedicine by linking smart devices and medical devices for physical examination. The marine telemedicine system adopts the HTTP communication protocol to configure the web server and process the client request. The patient's chart information was entered using an application for AndroidPad and the patient was diagnosed using Bluetooth electronic stethoscope for diagnosis. This system enables appropriate medical treatment to emergency patients at maritime, which ultimately can improve medical services. It is expected to be a more effective medical support system through linkage with various medical equipment.

Comparing the accuracy of saddle position and traditional position in head-up cardiopulmonary resuscitation (Head-up CPR 시 처치자의 위치에 따른 심폐소생술 정확도 비교)

  • Yoon, Byoung-Gil;Park, Jung-Hee
    • The Korean Journal of Emergency Medical Services
    • /
    • v.23 no.2
    • /
    • pp.99-107
    • /
    • 2019
  • Purpose: This study aimed to identify the position for the most accurate head-up cardiopulmonary resuscitation (CPR) by comparing saddle position CPR (SPCPR) and traditional CPR (TCPR). Methods: Sixty certified persons who completed a basic life support provider course between May 1 and June 21, 2019 were enrolled in the study. The participants were asked to perform 2 minutes of CPR, and the depth of chest compression, rate, position, full release, and hands off time were assessed. Accuracy was evaluated based on data collected from a smart phone application connected to the manikin via bluetooth and analyzed using frequency, percentage, t-test, analysis of variance and ${\chi}^2$. Results: The accuracy of chest compression was statistically significantly higher for SPCPR, 63.03%[${\pm}8.75$] for SPCPR and 55.50%[${\pm}10.17$] for TCPR [t=3.074, p=.003]. The depth of chest compression was statistically significantly greater for SPCPR, 4.51cm[${\pm}0.45$] for SPCPR and 4.16cm[${\pm}0.61$] for TCPR [t=2.503, p=.015]. The rate of chest compression was statistically significantly higher for TCPR, 105/min[${\pm}10.79$] for SPCPR and 111/min[${\pm}11.57$] for TCPR [t=-2.008, p=.049]. Accuracy of position of chest compression was statistically significantly higher for SPCPR, 96.10%[${\pm}13.73$] for SPCPR and 79.93%[${\pm}30.34$] for TCPR [t=2.659, p=.011]. Accuracy of full release was higher with SPCPR, with 86.30%[${\pm}30.53$] for SPCPR and 71.10%[${\pm}36.05$] for TCPR, but the difference was not statistically significant [t=1.762, p=.083]. Conclusion: Saddle position CPR was found to be more accurate than TCPR in the performance of manual head-up CPR.