• 제목/요약/키워드: BK-7 glass plate

검색결과 3건 처리시간 0.016초

Optical diffraction gratings embedded in BK-7 glasses by tightly focused femtosecond laser

  • Yoon, Ji Wook;Choi, Won Suk;Kim, Hoon Young;Cho, Sung-Hak
    • 한국레이저가공학회지
    • /
    • 제17권2호
    • /
    • pp.19-25
    • /
    • 2014
  • Optical embedded diffraction gratings with the bulk modification in BK-7 glass plates excited by tightly focused high-intensity femtosecond (130fs) Ti: sapphire laser (peak wavelength = 790nm) were demonstrated. The structural modifications with diameters ranging from 400nm to $4{\mu}m$ were photo-induced after plasma formation occurred upon irradiation with peak intensities of more than $1{\times}1013W/cm^2$. The graded refractive index profile was fabricated to be a symmetric around from the center of the point at which low-density plasma occurred. The maximum refractive index change was estimated to be $1.5{\times}10^{-2}$. The two optical embedded gratings in BK-7 glass plate were demonstrated with refractive index modification induced by the scanning of low-density plasma formation.

  • PDF

An innovative idea for developing a new gamma-ray dosimetry system based on optical colorimetry techniques

  • Ioan, Mihail-Razvan
    • Nuclear Engineering and Technology
    • /
    • 제50권3호
    • /
    • pp.519-525
    • /
    • 2018
  • Obtaining knowledge of the absorbed dose up-taken by a certain material when it is exposed to a specific ionizing radiation field is a very important task. Even though there are a plenitude of methods for determining the absorbed dose, each one has its own strong points and also drawbacks. In this article, an innovative idea for the development of a new gamma-ray dosimetry system is proposed. The method described in this article is based on optical colorimetry techniques. A color standard is fixed to the back of a BK-7 glass plate and then placed in a point in space where the absorbed dose needs to be determined. Gamma-ray-induced defects (color centers) in the glass plate start occurring, leading to a degree of saturation of the standard color, which is proportional, on a certain interval, to the absorbed dose. After the exposure, a high-quality digital image of the sample is taken, which is then processed (MATLAB), and its equivalent $I_{RGB}$ intensity value is determined. After a prior corroboration between various well-known absorbed dose values and their corresponding $I_{RGB}$ values, a calibration function is obtained. By using this calibration function, an "unknown" up-taken dose value can be determined.

GAP 모델 확립을 위한 토마토 농장 수확단계의 위해요소 조사 및 분석 (Risk Analysis for the Harvesting Stage of Tomato Farms to Establish the Good Agriculture Practices(GAP))

  • 이채원;이치엽;허록원;김경열;심원보;심상인;정덕화
    • 농업생명과학연구
    • /
    • 제46권4호
    • /
    • pp.141-153
    • /
    • 2012
  • 본 연구에서는 안전한 토마토를 생산하기 위한 농산물우수관리제도(Good Agriculture Practices; GAP) 모델 확립의 기초 자료를 제공하고자 경남에 소재한 토마토 재배 농가 중 토경 재배 3 농가와 양액 재배 3 농가를 대상으로 수확단계에서의 생물학적(위생지표세균, 병원성 미생물, 곰팡이), 화학적(중금속, 농약) 및 물리적 위해요소를 조사하였다. 먼저 생물학적 위해요소 분석결과, 일반세균과 대장균군은 토경재배 농장의 토양에서 최대 7.5 및 5.0 log CFU/g으로 양액재배 농장의 양액보다 0.1~2.8 log CFU/g 높은 수준으로 검출되었다. 그 외 다른 시료에서의 일반세균 및 대장균군의 경우 토경재배 농장에서는 1.7~6.5 및 0.3~2.9 log CFU/g, leaf, mL, hand or $100cm^2$로 검출되었고 양액재배 농장에서는 각각 1.1~5.7 및 0.1~4.0 log CFU/g, leaf, mL, hand or $100cm^2$로 검출되었다. 대장균은 모든 시료에서 검출되지 않았으며, 곰팡이의 경우 전체적으로 0.2~5.0 log CFU/g, leaf, mL, hand or $100cm^2$ 수준으로 검출되었다. 병원성 미생물은 Bacillus cereus와 Staphylococcus aureus만 양액을 제외한 대부분의 시료에서 검출되었으며, 공중낙하균은 토경재배 농장에서 0.4~1.6 log CFU/plate, 양액재배 농장에서 0.1~1.0 log CFU/plate 수준으로 검출되었다. 화학적 위해요소인 중금속(Cd, Pb, Cu, Cr, Hg, Zn, Ni 및 As)과 잔류농약은 모든 시료에서 국내 허용기준치 이하로 검출되었고, 물리적 위해요소는 다른 위해요소에 비해 발생가능성은 낮지만 유리조각, 캔 등으로 확인되었다.