• 제목/요약/키워드: BIPV

검색결과 225건 처리시간 0.046초

15kW급 차양식 BIPV시스템의 성능분석 (Performance Analysis of 15kW Sunshade BIPV System)

  • 소정훈;유권종;강기환;정영석;최주엽
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1474-1476
    • /
    • 2004
  • l5kW building integrated photovoltaic (BIPV) system had been installed and monitored at KIER in May 2003. Data acquisition system (DAS) is constructed for measuring and analyzing performance of PV system to observe the overall effect of environmental conditions on their operation characteristics. Performances of BIPV system have been evaluated and analyzed for component perspective (PV module and array, power conditioning system) and global perspective (system efficiency, capacity factor, electrical power energy) by long-term field test.

  • PDF

발코니형 BIPV시스템의 발전성능 향상을 위한 적용요소기술 분석 (Analysis of Application Elements for improvement in the generated electric power performance of balcony BIPV System)

  • 김현일;유권종;강기환;소정훈;이길송
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1483-1485
    • /
    • 2004
  • Photovoltaic(PV) technology is a popular part of building vocabulary. It can be used today on both existing and new buildings. Its use in the building envelope is very varied and open ways, such as roofing materials, facades, skylights and shading systems, for creative designers. So, to activate this systems demand appropriate sources of information, performance data of elements and design tools offering architects and designer. Therefore this paper describe application elements for BIPV system and then predict improvement in the generated electric power performance of balcony BIPV system.

  • PDF

3kW 건물일체형 태양광발전시스템의 출력특성 (The Output Characteristics of 3kW BIPV System)

  • 김지훈;김평호;임양수;조금배;백형래;오금곤
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.471-474
    • /
    • 2006
  • BIPV(Building Integrated PV) system can expect dual effects that reduce expenses for establishment of PV system by adding new function as outer covering material of building expect producing the electricity. But, there are many generation differences according to the exterior environmental facts(solar cell away, design and installation condition of interactive inverter system) Therefore, it is difficult to optimum design. Consequently in advance design system, we experiment 3kW BIPV(Building Integrated PV) generation. We concrete PV system efficient application of variable. BIPV system that is proposed in this paper, was established in Solar Energy research center of Chosun University, composed with system. This research is a basic study for application of building integrated photovoltaic system for builing.

  • PDF

발코니형 BIPV시스템의 성능 분석 (Performance Analysis of Balcony BIPV System)

  • 김현일;강기환;소정훈;유권종;박경은;이길송;서승직
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.208-209
    • /
    • 2007
  • Photovoltaic(PV) based electricity production is pollution-free at the local as well as the global level, it does not emit greenhouse gases, it dose not dip into finite file resources and it can be easily integrated into the urban environment, close to major consumption needs. So BIPV(Building-Integrated Photovoltaics) system have been increased around the world. This paper presents measuring and analyzing performance of balcony BIPV system which have been installed and monitoring. The system is influenced by conditions such as irradiation, module temperature, shade and architectural component etc. By the results, it is very important to develop optimal design for the balcony PV system.

  • PDF

고층 빌딩에 적용되는 빌딩통합형 태양광패널 효율성 개선방안 (Efficiency Improvement for Building Integrated Photovoltaic Applied to High-rise Building)

  • 이도현;안인석
    • 한국산업융합학회 논문집
    • /
    • 제25권1호
    • /
    • pp.71-78
    • /
    • 2022
  • With the advent of cutting-edge technology, renewable energy is significantly considered as alternative resources to supply electric power. However, many barriers such as energy intermittency, high initial installation cost, and low-efficiency generation challenged building new infrastructure with clean energy. Efforts reducing greenhouse gas emissions and reliance on fossil fuels resulted in the decentralization of power generation like distributed energy resource (DER). This paper is to introduce and evaluate the feasibility of building-integrated photovoltaics (BIPV) in a high-rise building in Ulsan. To optimize BIPV, a variety of methods to minimize efficiency decrease and maximize electric power generation after installing BIPV on the building's facade are suggested. The variables causing power losses are analyzed. By utilizing System Advisor Model (SAM), actual power generated from solar panels is measured by Thin-film PV, Mono-crystalline PV, and Poly-crystalline PV.

BIPV 시스템을 위한 전이금속 산화물 다중층 컬러 유리 구현 기술 연구 (Transition Metal Oxide Multi-Layer Color Glass for Building Integrated Photovoltaic System)

  • 안현식;;장은정;김민회;이재현;최윤석
    • 전기전자학회논문지
    • /
    • 제23권4호
    • /
    • pp.1128-1133
    • /
    • 2019
  • 이 논문에서는 전이 금속 산화물(TMO)층으로 구성된 다층 박막을 사용하는 BIPV(Building Integrated Photovoltaic) 시스템용 전면 컬러 유리를 제안하였다. 몰리브덴 산화물(MoO3) 및 텅스텐 산화물(WO3)은 굴절률 차이가 큰 계면을 형성하여 적절한 간섭효과를 얻을 수 있다. 단일 Thermal Evaporator 증착 방법을 통해 다층 박막을 제작함으로써 간단하고 빠르며 저렴한 제조 방법을 제안하였다. MoO3(60nm)/WO3(100nm) 다층 박막으로 90% 이상의 광 투과율을 갖는 자홍색 유리를 시연하였으며, 이 기술은 상용화된 BIPV 시스템에 유용할 것으로 기대된다.

대학교 기숙사의 전력소비량과 BIPV시스템의 발전효율·부하부담율에 관한 연구 (A Study on the Power Consumption and the Generation Efficiency and Load Rate of the Building Integrated Photovoltaic System in University Dormitories)

  • 서원덕;이강국;홍원화
    • KIEAE Journal
    • /
    • 제11권6호
    • /
    • pp.87-93
    • /
    • 2011
  • This study examines building's power consumption unit cost and Building Integrated Photovoltaic (BIPV)'s generation efficiency and load rate with the subjects of university dormitory buildings in order to suggest foundational data for new and recycled energy use and management to plan and operate university dormitories afterwards. Thereby, this research gained the following findings. 1. The quantity of solar radiation and efficiency change in the BIPV system applied to the research subject buildings after the lapse of time was averagely 8.7%, and it is thought that temperature increase determines conversion efficiency with the influence of surrounding outside temperature and the module's temperature. 2. The generation efficiency of the BIPV system in the research subject buildings was averagely 10.9%. In May, it was 13.9%, and in January, it was the lowest as 10.25%. Considering the fact that power consumption reduces during an intermediate period, it will be necessary to establish measures for equipment and power consumption load balancing. 3. The monthly load rate of the BIPV system was averagely 4.09%. In May, it was the highest as 4.94%, and in July, it was the lowest as 3.24%. 4. It is intended to conduct constant follow-up research on estimating university dormitory building's power consumption unit cost and examining the generation efficiency and load rate of the BIPV system.

주택지붕용 2kWp BIPV시스템의 성능 실험 및 전기 부하 감당에 관한 연구 (The Performance and Energy Saving Effect of a 2kWp Roof-Integrated Photovoltaic System)

  • 이강록;오명택;박경은;김진희;김준태
    • 한국태양에너지학회 논문집
    • /
    • 제26권1호
    • /
    • pp.13-19
    • /
    • 2006
  • The efficiency of building-integrated photovoltaic(BIPV) system is mainly determined by solar radiation and the temperature of PV modules. The performance of BIPV systems is reported to be different from that of conventional PV systems installed in the open-air. This paper presents the relationship of solar radiation and electricity generation from a 2kWp roof-integrated PV system that is applied as building elements on an experimental house, and the energy saving effect of the BIPV system for a typical house. For the performance evaluation of the BIPV system, it produced a regression equation with measured data for winter days. The regression equation showed that a comparison of the measured electricity generation and the predicted electricity generation of the BIPV system were meaningful. It showed that an annual electricity generation of the system appeared to cover around 52% of an annual electricity consumption of a typical domestic house with the floor area of $96m^2$.