• Title/Summary/Keyword: BIOMECHANICAL

Search Result 947, Processing Time 0.03 seconds

Biomechanical Fatigue Analysis of Cervical Plate Systems by using a Computer Simulation Based on Finite Element Method (유한요소법을 이용한 척추 삽입형 경추판 시스템에 대한 생체역학적 피로해석)

  • Kim, Sung-Min;Yang, In-Chul;Cho, Sung-Youn
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.8
    • /
    • pp.96-103
    • /
    • 2008
  • In this study, we performed the biomechanical analysis of cervical plate systems by using a computer simulation based on finite element method to derive reliable model by analysis of design variables and fatigue behavior. To simulate the cervical spine movement in-vivo state by surgery, we modeled the cervical plate system which consisted of screws, rings, rivets, and plate and Ultra High Molecular Weight Polyethylene (UHMWPE) Block. The experiment of cervical plate system followed the ASTM F1717 standards that covered the materials and methods for the static and fatigue testing. The result of computer simulation is compared with experimented test. We expected this study is to derive reliable results by analysis of design variables and fatigue behavior for developing a new model.

Biomechanical adaptation of orthodontic tooth movement (임상가를 위한 특집 2 - 교정력에 의한 치아이동과 Biomechanical adaptation)

  • Lee, Syng-Ill
    • The Journal of the Korean dental association
    • /
    • v.51 no.3
    • /
    • pp.138-147
    • /
    • 2013
  • Orthodontic tooth movement is a unique process which tooth, solid material is moving into hard tissue, bone. Orthodontic force in general provides the strain to the PDL and alveolar bone, which in turn generates the interstitial fluid flow(in detail, fluid flow in PDL and canaliculi). As a results of matrix strain, periodontal ligament cells and bone cells are deformed, releasing variety of cytokines, chemokines, and growth factors. These molecules lead to the orthodontic tooth movement(OTM). In these inflammation and tissue remodeling sites, all of the cells could closely communicate with one another, flowing the information for tissue remodeling. To accelerate the rate of OTM in future, local injection of single growth factor(GF) or a combination of multiple GFs in the periodontal tissues might intervene to stimulate the rate of OTM. Corticotomy is effective and safe to accelerate OTM.

The Study on a Biomechanical Model for Automotive Seat Design (자동차 SEAT DESIGN을 위한 BIOMECHANICAL MODEL 연구)

  • 신학수;최출헌
    • Proceedings of the ESK Conference
    • /
    • 1998.04a
    • /
    • pp.149-154
    • /
    • 1998
  • The design of seat is maintaining to final stable posture. The final stable posture is the seated posture in which the force of the pad and spring supporting the body is balanced with the body weight and the bodydoes not sink anyfurther intothe seat. With poorly designed seated seats, your behind maygradually move forward, or localized pressure may result in congestion of the blood or numbness, making you want to move. Therefore, the final stable posture is not maintained. A number of ideas were used in this study will eliminate this problem. In automobile seat design, primary attention has forcused on providing the occupant with a comfortable seat that has sufficient padding and adjuxtments toaccomodate different sizes and postures of people. First of all, whether the process is design-oriented or technology-oriented, the design concept must be human-oriented. The fatigue-alleviating seats which were the primary purpose of this research were studied with a human-oriented approach.

  • PDF

Estimation of anthropometric body dimensions and joint strengths of a worker performing manual materials handling tasks using a multivariate normal simulation model (다변량 정규분포 모의모형을 이용한 물자운반작업을 수행하는 작업자의 인체 치수 및 관절염력의 예측에 관한 연구)

  • 변승남
    • Journal of the Ergonomics Society of Korea
    • /
    • v.12 no.2
    • /
    • pp.63-83
    • /
    • 1993
  • The primary objective of the research is to develop a mathematical method to incorporate the variability of anthropometric body dimensions and joint strengths of individuals in a biomechanical analysis. A multivariate normal simulation model estimated anthropometric body dimensions and joint strengths of the random link-person, based on the assumptions that the vari- ables of body dimensions and joint strengths are correlated and follow normal distributions. Statistical comparative analysis demonstrated that the random link-person represented a more realistic human-like form in an anthropometric sense than the proportional link-person whose body dimensions were estimated proportionally. Estimated joint strengths for the random link-person, however, did not match the measured joint strengths as closely as the estimated body dimensions. The random link-person will allow biomechanical analysis of manual materials handling tasks to be individualized with respect to the anthropometry and a static strength.

  • PDF

The study on microslip using a signal detection theory

  • Son, D.H.;Li, K.W.
    • Journal of the Ergonomics Society of Korea
    • /
    • v.10 no.2
    • /
    • pp.51-55
    • /
    • 1991
  • Since slipping has been identified as a major hazard, it is important to understand the mechanism of a slip. Many researches, based on biomechanical studies, had been attempted to do that. Thowever, the correlation between the mechanism of a slip and psychophysical behaviors of people had rarely been verified. For example, the existence of small slips in a forward direction, which do not normally perceived by human subjects, has been established by several experimenters. However, the term "microslips are not perceived by the walkers[4]." has not been examined precisely by any experiments. The objective of this study is, using a Signal Detection Theory (SDT), to define a microslip and slip more quqntitatively with the biomechanical measurement of slip distance. The results showed that, the slip distance around the 3 centimeters, there was a obvious change in the accident detectability of the subject. The conclusion is that it is possible to identify the boundary of a microslip and slip around the 3 centermeters of slip distance.

  • PDF

Impedance modulation of anthropomorphic robots with kinematic and force redundancies (여유자유도/여유구동 인체형 로봇의 임피던스 생성방식)

  • 이병주;김희국;이재훈
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1289-1292
    • /
    • 1997
  • Typical biomechanical system such as human body and mammals possess abundant muscles which are more than required for motion generation of such systems. We have shown that the excess number of muscles play important roles in spring-like impedance modulation. redundant kinematic structure, which is another feature of biomechanical systems, allows modulations of inertia and damping properties of such systems. In this work, we propose a frequency modulation algorithm which combines the spring-like impedance with inertia impedance. also, a load distribution method for frequency modulation is also introduced. The frequency modulation represents a simulataneous control of force and kinematic redundancies, which has not been addressed in the literature.

  • PDF

Fabrication and Biomechanical Characteristics of Composite Ceramic Bone Scaffolds for Bone Tissue Engineering (골 생체조직공학을 위한 복합 세라믹 골 지지체의 제조와 생체역학적 특성)

  • Kim E. S.;Chung J. H.
    • Journal of Biosystems Engineering
    • /
    • v.29 no.5 s.106
    • /
    • pp.457-466
    • /
    • 2004
  • Novel porous composite ceramic bone scaffolds composed of biodegradable PHBV(polyhydroxybutyrate-co-hydroxyvalerate) and TA(toothapatite) have been fabricated for bone tissue engineering by a modified solvent casting and particulate leach-ing method with salt-contained heat compression technique. The results of this study suggest that the PHBV-TA composite scaffold, especially the scaffold containing 30 weight$\%$ of TA may be a good candidate far bone tissue engineering of non-load bearing area in oral and maxillofacial region.

Development of a nonlinear biomechanical soft tissue model for a virtual surgery trainer (가상수술기를 위한 비선형 생체 모델의 개발)

  • Kim J.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.911-914
    • /
    • 2005
  • Soft tissue characterization and modeling based on living tissues has been investigated in order to provide a more realistic behavior in a virtual reality based surgical simulation. In this paper, we characterize the nonlinear viscoelastic properties of intra-abdominal organs using the data from in vivo animal experiments and inverse FE parameter estimation algorithm. In the assumptions of quasi-linear-viscoelastic theory, we estimated the nonlinear material parameters to provide a physically based simulation of tissue deformations. To calibrate the parameters to the experimental results, we developed a three dimensional FE model to simulate the forces at the indenter and an optimization program that updates new parameters and runs the simulation iteratively. The comparison between simulation and experimental behavior of pig intra abdominal soft tissue are presented to provide a validness of the tissue model using our approach.

  • PDF

A Study on the Stress and Strain Analysis of Human Muscle Skeletal Model in Kendo Three Typical Attack Motions (세 가지 주요 검도 공격 동작에서의 근-골격계 응력과 번형률 해석에 관한 연구)

  • Lee, Jung-Hyun;Lee, Young-Shin
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.9
    • /
    • pp.126-134
    • /
    • 2008
  • Kendo is one of the popular sports in modem life. Head, wrist and thrust attack are the fast skill to get a score on a match. Human muscle skeletal model was developed for biomechanical study. The human model was consists with 19 bone-skeleton and 122 muscles. Muscle number of upper limb, trunk and lower limb part are 28, 60, 34 respectively. Bone was modeled with 3D beam element and muscle was modeled with spar element. For upper limb muscle modelling, rectus abdominis, trapezius, deltoideus, biceps brachii, triceps brachii muscle and other main muscles were considered. Lower limb muscle was modeled with gastrocenemius, gluteus maximus, gluteus medius and related muscles. The biomechanical stress and strain analysis of human muscle was conducted by proposed human bone-muscle finite element analysis model under head, wrist and thrust attack for kendo training.