• Title/Summary/Keyword: BIOMECHANICAL

Search Result 954, Processing Time 0.029 seconds

Effects of Screw Diameter and Thread Shape on the Strength of Transpedicular Screw Fixation in Posterior Spinal Fusion (후방 척추고정술에서 척추경 나사못의 크기와 형태가 척추 고정력에 미치는 영향에 대한 연구)

  • Mun, Mu-S.;Ryu, Jei-C.;Yoo, Myung-C.;Kim, Ki-T.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.05
    • /
    • pp.23-26
    • /
    • 1995
  • The objectives of the present study are 1)to find the effect of the diameter of transpedicular screws on their fixational strength in pedicles under static pull-out loading, 2)to determine the biomechanical correlation between the pedicle diameter and the screw diameter, and 3)to find the effects of other factors in the screw design, such as materials, screw pitch, thread height and shape on their fixational strength. Biomechanical tests (Test I) were performed to evaluate the effect of the screw diameter on pull-out strength by using 60 porcine pedicls and six groups of custom-made pedicle screws with different diameters (the major and the minor diameter of the screws used in the testing varied from 4mm upto 9mm and from 3mm upto 8mm, respectively) while all other factors (materials, screw pitch, thread height and shape etc.) were fixed. In Test II, by using 61 porcine pedicles, the relationship between the ratio of the pedicle diameter and the screw diameter(=aspect ratio) of the custum-made screw and the pull-out strength of the screw was investigated. Test III was performed with 94 porcine pedicles and 8 different types of the commercial screws from 6 major productors in order to determine the effect of the screw diameter, pitch and the thread shape on the pull-out strength of the screw, respectively. The results of Test I showed that the axial pull-out resistance of the screw could be increased prportionaly to the screw diameter(P<0.05). But this increase in the pull-out resistance did not found when the screws of 4mm or 9mm in the diameter were employed. It was found from the results of Test II that the screws had its maximum pull-out resistant force when the aspect ratio ranging 40 - 69% (P<0.05). based on the results for the major diameter against the minor diameter of screw, the maximal pull-out resistance was found at 60-65% (P<0.05). According to these biomechanical testing results, it seems that the screw with a moderately large pitch is more desirable and the buttress-shaped screw can provide stronger fixation than the V-shape one can, if other designal factor and conditions were fixed.

  • PDF

Biomechanical Analysis of a Combined Interspinous Spacer with a Posterior Lumbar Fusion with Pedicle Screws (척추경나사못을 이용한 유합술과 동반 시술된 극돌기간 삽입기구의 생체역학적 연구)

  • Kim, Y.H.;Park, E.Y.;Lee, S.J.
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.6
    • /
    • pp.276-282
    • /
    • 2015
  • Recently, during the multi-level fusion with pedicle screws, interspinous spacer are sometimes substituted for the most superior level of the fusion in an attempt to reduce the number of fusion level and likelihood of degeneration process at the adjacent level. In this study, a finite element (FE) study was performed to assess biomechanical efficacies of the interspinous spacer combined with posterior lumbar fusion with a previously-validated 3-dimensional FE model of the intact lumbar spine (L1-S1). The post-operative models were made by modifying the intact model to simulate the implantation of interspinous spacer and pedicle screws at the L3-4 and L4-5. Four different configurations of the post-op model were considered: (1) a normal spinal model; (2) Type 1, one-level fusion using posterior pedicle screws at the L4-5; (3) Type 2, two-level (L3-5) fusion; (4) Type 3, Type 1 plus Coflex$^{TM}$ at the L3-4. hybrid protocol (intact: 10 Nm) with a compressive follower load of 400N were used to flex, extend, axially rotate and laterally bend the FE model. As compared to the intact model, Type 2 showed the greatest increase in Range of motion (ROM) at the adjacent level (L2-3), followed Type 3, and Type 1 depending on the loading type. At L3-4, ROM of Type 2 was reduced by 34~56% regardless of loading mode, as compared to decrease of 55% in Type 3 only in extension. In case of normal bone strength model (Type 3_Normal), PVMS at the process and the pedicle remained less than 20% of their yield strengths regardless of loading, except in extension (about 35%). However, for the osteoporotic model (Type 3_Osteoporotic), it reached up to 56% in extension indicating increased susceptibility to fracture. This study suggested that substitution of the superior level fusion with the interspinous spacer in multi-level fusion may be able to offer similar biomechanical outcome and stability while reducing likelihood of adjacent level degeneration.

Biomechanical Evaluation for Washing Machine Design Suggested Newly for Prevention of Musculoskeletal Disorders (근골격계 질환 예방을 위하여 새로이 제시된 세탁기 디자인에 대한 생체역학적 평가)

  • Cho, Young-Kuen;Choi, Hue-Seok;Kim, Hyun-Dong;Choi, Hyun-Ho;Youn, Join-In;Kim, Young-Ho;Shin, Tae-Min;Kim, Han-Sung;Lim, Do-Hyung
    • Journal of the Ergonomics Society of Korea
    • /
    • v.27 no.4
    • /
    • pp.27-35
    • /
    • 2008
  • Recently, many studies have reported the fact that an excessively accumulated psychological and physical burden induced from physical labor conducted routinely in home and industry can be one of main reasons of musculoskeletal disorders in the working population. This fact makes increase interests in studies to reduce a risk of musculoskeletal disorders through grafting ergonomic considerations on working environment. However, there are currently limited methodologies in quantitative evaluations of new ergonomic suggestions to reduce a risk of musculoskeletal disorders. The current study is therefore performed to evaluate quantitatively effects of a design of washing machine as a new ergonomic suggestion onto prevention of musculoskeletal disorders, through application of a biomechanical evaluation methodology. For this, three-dimensional motion analysis by using musculoskeletal models with Rapid Entire Body Assessment (REBA), which has been generally used for a simple evaluation of a degree of harmfulness of the human body at specific working postures to be considered, was performed. The results of REBA did not give us enough information and their results were somewhat simple and inaccurate, but the results of the three-dimensional motion analysis give us enough information such as alteration of main muscle forces and joint moments required during washing work. All results showed that the main muscle strengths and joint moments were decreased effectively for reduction of a risk of musculoskeletal disorders during the washing work with newly designed washing machine evaluated in the current study, compared with those generated during the washing work with general washing machine. From these results, it can be concluded that a risk of the musculoskeletal disorders, which may be induced by a repetitive washing work, may be reduced through using the washing machine designed ergonomically and newly. Also, it is thought that if our ergonomic design can be applied for improvement of working environment in lifting and laying works conducted repeatedly for a treatment work of goods, which have a strong resemblance to the behaviors generated frequently during the washing work, a possibility of occurrence of the musculoskeletal disorders by the lifting and laying works may be reduced highly.

A Study on the Change of Gait Temporal Parameter and Ankle Joint Moment in Patients with Achilles Tendinitis (아킬레스 건염 환자의 보행 시 고관절, 슬관절 및 족관절 모멘트의 변화에 대한 연구)

  • Yu, Jae-Ho;Lee, Gyu-Chang;Lee, Dong-Yeop
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.12
    • /
    • pp.5766-5772
    • /
    • 2011
  • This study was to investigate the change of gait temporal parameter and ankle joint moment between patients with achilles tendinitis and healthy people. Thus, the purpose of this study is to clarify biomechanical change of gait in patients with achilles tendinitis and to find risk factor for prevention of achilles tendinitis. We recruited 20 patients with an achilles tendinitis and 20 healthy people. While subjects shuttled 5 times on 13 m distance with comfortable pace, we examined gait function marker with three-dimensional gait analysis system. All subject outstepped center of forceplate during gait and calculated ankle joint moment using software. Obtained data was analyzed using SPSS 12.0 software. In results, we confirmed that patients with achilles tendinitis showed reduction of extension moment in early initial phase and reduction of flexion moment in mid-stance on hip joint. and reduction of flexion moment in early initial phase and reduction of extension moment in late phase on knee joint. And we identified that patients with achilles tendinitis showed reduction of dorsiflexion moment in early stance phase, maximal plantarflexion moment in mid stance phase, and dorsiflexion moment in late stance phase. Thus, there are biomechanical changes on gait in patients with achilles tendinitis compared to healthy people. And, in clinical settings, they should focus on changes of gait in patients with achilles tendinitis. Further study will be undertaken for the biomechanical changes of patietns with achilles tendinitis.

Bone-Preserving Decompression Procedures Have a Minor Effect on the Flexibility of the Lumbar Spine

  • Costa, Francesco;Ottardi, Claudia;Volkheimer, David;Ortolina, Alessandro;Bassani, Tito;Wilke, Hans-Joachim;Galbusera, Fabio
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.6
    • /
    • pp.680-688
    • /
    • 2018
  • Objective : To mitigate the risk of iatrogenic instability, new posterior decompression techniques able to preserve musculoskeletal structures have been introduced but never extensively investigated from a biomechanical point of view. This study was aimed to investigate the impact on spinal flexibility caused by a unilateral laminotomy for bilateral decompression, in comparison to the intact condition and a laminectomy with preservation of a bony bridge at the vertebral arch. Secondary aims were to investigate the biomechanical effects of two-level decompression and the quantification of the restoration of stability after posterior fixation. Methods : A universal spine tester was used to measure the flexibility of six L2-L5 human spine specimens in intact conditions and after decompression and fixation surgeries. An incremental damage protocol was applied : 1) unilateral laminotomy for bilateral decompression at L3-L4; 2) on three specimens, the unilateral laminotomy was extended to L4-L5; 3) laminectomy with preservation of a bony bridge at the vertebral arch (at L3-L4 in the first three specimens and at L4-L5 in the rest); and 4) pedicle screw fixation at the involved levels. Results : Unilateral laminotomy for bilateral decompression had a minor influence on the lumbar flexibility. In flexion-extension, the median range of motion increased by 8%. The bone-preserving laminectomy did not cause major changes in spinal flexibility. Two-level decompression approximately induced a twofold destabilization compared to the single-level treatment, with greater effect on the lower level. Posterior fixation reduced the flexibility to values lower than in the intact conditions in all cases. Conclusion : In vitro testing of human lumbar specimens revealed that unilateral laminotomy for bilateral decompression and bone-preserving laminectomy induced a minor destabilization at the operated level. In absence of other pathological factors (e.g., clinical instability, spondylolisthesis), both techniques appear to be safe from a biomechanical point of view.

The Effect of Gender Difference in Injury Experience on Biomechanical Variables of Lower Extremity during Two Leg Drop Landing (양발 착지 시 성별에 따른 상해 경험이 하지관절의 운동역학적 변인에 미치는 영향)

  • Lee, Seong-Yeol;Kwon, Moon-Seok
    • Journal of the Korean Applied Science and Technology
    • /
    • v.36 no.2
    • /
    • pp.424-433
    • /
    • 2019
  • The purpose of this study was to investigate the effects of gender difference in injury experience on biomechanical variables of lower extremity during two leg drop landing. 20 male(injury experience=8, non-injury experience=12) and 20 female(injury experience=11, non-Injury Experience=9) in their 20's were selected as subjects. Two-way mixed ANOVA was performed on the biomechanical variables obtained from the two leg drop landing in a 45cm height box and post-test was performed with bonferroni adjustment(p <.05). The results of this study suggest that the group of female who injury experience could induce the reduction of the peak vertical ground reaction force by increasing the valgus and internal rotation of the knee joint and flexion and internal rotation of the hip joint. In the INE(injury non-experienced) female group, the peak knee flexion angle was the smallest, as well as the flexion of the hip joint and the external rotation angle, and the peak vertical ground reaction force was the highest. On the other hand, the INE female group showed high vertical ground reaction force because they did not utilize the knee and hip joints relatively than the IE(injury experienced) female group, this means that it is relatively exposed to the risk of injury. Therefore, it was found that gender difference in injury experience is a factor affecting factors of knee and hip joint movement and peak vertical GRF(ground reaction force).

CBCT-based assessment of root canal treatment using micro-CT reference images

  • Lamira, Alessando;Mazzi-Chaves, Jardel Francisco;Nicolielo, Laura Ferreira Pinheiro;Leoni, Graziela Bianchi;Silva-Sousa, Alice Correa;Silva-Sousa, Yara Terezinha Correa;Pauwels, Ruben;Buls, Nico;Jacobs, Reinhilde;Sousa-Neto, Manoel Damiao
    • Imaging Science in Dentistry
    • /
    • v.52 no.3
    • /
    • pp.245-258
    • /
    • 2022
  • Purpose: This study compared the root canal anatomy between cone-beam computed tomography (CBCT) and micro-computed tomography (micro-CT) images before and after biomechanical preparation and root canal filling. Materials and Methods: Isthmus-containing mesial roots of mandibular molars(n=14) were scanned by micro-CT and 3 CBCT devices: 3D Accuitomo 170 (ACC), NewTom 5G (N5G) and NewTom VGi evo (NEVO). Two calibrated observers evaluated the images for 2-dimensional quantitative parameters, the presence of debris or root perforation, and filling quality in the root canal and isthmus. The kappa coefficient, analysis of variance, and the Tukey test were used for statistical analyses(α=5%). Results: Substantial intra-observer agreement (κ=0.63) was found between micro-CT and ACC, N5G, and NEVO. Debris detection was difficult using ACC (42.9%), N5G (40.0%), and NEVO (40%), with no agreement between micro-CT and ACC, N5G, and NEVO (0.05<κ<0.12). After biomechanical preparation, 2.4%-4.8% of CBCT images showed root perforation that was absent on micro-CT. The 2D parameters showed satisfactory reproducibility between micro-CT and ACC, N5G, and NEVO (intraclass correlation coefficient: 0.60-0.73). Partially filled isthmuses were observed in 2.9% of the ACC images, 8.8% of the N5G and NEVO images, and 26.5% of the micro-CT images, with no agreement between micro-CT and ACC, and poor agreement between micro-CT and N5G and NEVO. Excellent agreement was found for area, perimeter, and the major and minor diameters, while the roundness measures were satisfactory. Conclusion: CBCT images aided in isthmus detection and classification, but did not allow their classification after biomechanical preparation and root canal filling.

Biomechanical Analysis of Elderly Fall Related Risk Factors using Downhill Walking on Treadmill (트레드밀 내리막 보행을 이용한 노인 낙상관련 위험요인의 운동역학적 분석)

  • Woo, Jeong-Hyun;Park, Sang-Kyoon
    • 한국체육학회지인문사회과학편
    • /
    • v.55 no.2
    • /
    • pp.643-655
    • /
    • 2016
  • The purpose of this study was to investigate biomechanical differences between young and old adults during downhill walking on a treadmill in order to understand the mechanisms of elderly falls. Eighteen healthy young females(YG: yrs: 21.17±1.5) and eighteen healthy old females(OG: yrs: 66.67±1.33) participated in this study. They were asked to walk at their preferred speed on a treadmill at level, 7.5° and 15° decline. OG walked more wobbly in the medial and lateral directions than YG(p<.05). As slope got steeper, OG had smaller ROM(range of motion) of ankle and knee joints compared with YG. However, there was no difference in ROM of the hip between OG and YG, but maximum extension angle of OG was smaller compared with YG(p<.05). Smaller extensor moment was generated on OG during downhill walking(p<.05). It was hypothesized that more risk factors would be found on older people compared to young people during downhill. However, older people actually walks with a safer strategy compared to young people during downhill. Finally, current findings about biomechanical characteristics of elderly walking would provide useful fundamental information for a follow-up study regarding the prevention of elderly fall during their daily life.