• Title/Summary/Keyword: BIOMECHANICAL

Search Result 959, Processing Time 0.024 seconds

Effect of Landing Heights on Muscle Activities and Ground Reaction Force during Drop Landing in Healthy Adults (정상 성인에서 착지 시 착지 높이가 근활성도와 지면반발력에 미치는 영향)

  • Chang, Jong-Sung;Lee, Mi-Young
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.6 no.2
    • /
    • pp.145-151
    • /
    • 2011
  • Purpose: The study was designed to investigate the effects of landing heights on muscle activities and ground reaction force during drop landing. Methods: Sixteen healthy adults were recruited along with their written informed consent. They performed a drop-landing task at the height of 20, 40, and 60cm. They completed three trials in each condition and biomechanical changes were measured. The data collected by each way of landing task and analyzed by One-way ANOVA. Ground reaction forces were measured by force flate, muscle activities measured by MP150 system. Results: There were significant differences in ground reaction forces, and significant increases in muscle activities of tibialis anterior, medial gastrocnemius and biceps femoris with landing heights. Conclusion: These findings revealed that heights of landing increases risk factors of body damage because of biomechanical mechanism and future studies should focus on prevention from damage of external conditions.

Surgical Management of a Mandible Subcondylar Fracture

  • Kang, Dong Hee
    • Archives of Plastic Surgery
    • /
    • v.39 no.4
    • /
    • pp.284-290
    • /
    • 2012
  • Open reduction and anatomic reduction can create better function for the temporomandibular joint, compared with closed treatment in mandible fracture surgery. Therefore, the double miniplate fixation technique via mini-retromandibular incision was used in order to make the most stable fixation when performing subcondylar fracture surgery. Those approaches provide good visualization of the subcondyle from the posterior edge of the ramus, allow the surgeon to work perpendicularly to the fracture, and enable direct fracture management. Understanding the biomechanical load in the fixation of subcondylar fractures is also necessary in order to optimize fixation methods. Therefore, we measured the biomechanical loads of four different plate fixation techniques in the experimental model regarding mandibular subcondylar fractures. It was found that the loads measured in the two-plate fixation group with one dynamic compression plate (DCP) and one adaption plate showed the highest deformation and failure loads among the four fixation groups. The loads measured in the one DCP plate fixation group showed higher deformation and failure loads than the loads measured in the two adaption plate fixation group. Therefore, we conclude that the selection of the high profile plate (DCP) is also important in order to create a stable load in the subcondylar fracture.

A Study of Biomechanical Simulation Model for Spinal Fusion using Spinal Fixation System (척추경 고정 나사 시스템을 이용한 척추 유합 시술의 생체역학적 분석 모델 연구)

  • Kim, Sung-Min;Yang, In-Chul;Kang, Ho-Chul
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.2
    • /
    • pp.137-144
    • /
    • 2010
  • In general, spinal fusion surgery takes pressure off the pain induced nerves, by restoring the alignment of the spine. Therefore spinal fixation system is used to maintain the alignment of spine. In this study, a biomechanical study was performed comparing the SROM(Spinal Range Of Motion) of three types of system such as Rigid, Dynesys, and Fused system to analyze the behavior of spinal fixation system inserted in vertebra. Dynesys system, a flexible posterior stabilization system that provides an alternative to fusion, is designed to preserve inter-segmental kinematics and alleviate loading at the facet joints. In this study, SROM of inter-vertebra with spinal fixation system installed in the virtual vertebra from L4 to S1 is estimated. To compare with spinal fixation system, a simulation was performed by BRG. LifeMOD 2005.5.0 was used to create the human virtual model of spinal fixation system. Through this, each SROM of flexion, extension, lateral bending, and axial rotation of human virtual model was measured. The result demonstrates that the movement of Dynesys system was similar to normal condition through allowing the movement of lumbar.

Analysis on the Effect of Lordosis Changes at Lumbar Joint using 3-dimensional Musculoskeletal Model (근골격계 모델을 이용한 요추전만 각도 변화가 요추 관절에 미치는 영향 분석)

  • Bae, Tae-Soo;Kim, Shin-Ki;Ryu, Je-Chung;Mun, Mu-Seong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.10
    • /
    • pp.116-121
    • /
    • 2009
  • It is important to consider lumbar lordotic angle for setup of training program in field of sports and rehabilitaton to prevent unexpected posture deviation and back pain. The purpose of this study was to analyze the biomechanical impact of the level of lumbar lordosis angle during isokinetic exercise through dynamic analysis using a 3-dimensional musculoskeletal model. We made each models for normal lordosis, excessive lordosis, lumbar kyphosis, and hypo-lordosis according to lordotic angle and inputted experimental data as initial values to perform inverse dynamic analysis. Comparing the joint torques, the largest torque of excessive lordosis was 16.6% larger and lumbar kyphosis was 11.7% less than normal lordosis. There existed no significant difference in the compressive intervertebral forces of each lumbar joint (p>0.05), but statistically significant difference in the anterioposterior shear force (p<0.05). For system energy lumbar kyphosis required the least and most energy during flexion and extension respectively. Therefore during the rehabilitation process, more efficient training will be possible by taking into consideration not simply weight and height but biomechanical effects on the skeletal muscle system according to lumbar lordosis angles.

The Biomechanical Analysis of the First Hurdling in Men's 110m Hurdle between Skilled and Less-Skilled Hurdle Players (110 m 허들경기의 제 1허들에 대한 우수선수와 비우수선수의 운동역학적 요인 비교)

  • Gil, Ho-Jong;Yoon, Sukhoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.23 no.1
    • /
    • pp.11-17
    • /
    • 2013
  • The purpose of this study was to provide a fundamental information for enhancing 110m hurdlers' performance through conducting comparative biomechanical analysis between Skilled Group(SG) and Less-Skilled Group(LSG) those who are not in the first section of 110m hurdles. To persue the purpose of this study, total of 10 hurdlers participated. Then they were divided into two groups; SG: five hurdlers who have won awards with 14-second range at 2010 national track and field event, and LSG: five hudlers who did not win any awards with 15-second range. Three-dimensional motion analysis with 12 infrared cameras(Oqus 300, Qualisys) and 1 force plate(Type 9286AA, Kistler) was performed. From this study following conclusions were obtained. 1) For the overall runtime, SG revealed faster elapsed time than that of LSG. 2) At E4, LSG showed greater trunk angle than that of SG. 3) At E3 LSG revealed higher angular velocities than that of SG. 4) No significant differences was found for AP GRF between groups but LSG showed greater VGRF than that of SG.

Biomechanical Evaluation of PMMA Injection in Vertebroplasty (척추성형술 시술에서 PMMA주입에 대한 흉추의 생체역학적 평가)

  • 이준형;채수원;이태수;서중근;박정율;김상돈;이관행
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.1
    • /
    • pp.27-32
    • /
    • 2004
  • In this study, method of PMMA injection is suggested for vertebroplasty in patients with osteoporotic compression fracture. The finite element analysis is used to investigate the vertebroplasty quantitatively. In order to improve previous works with simplified geometry of vertebral body more exact geometry has been constructed from CT image data with 1m thickness. An ideal method of PMMA delivery, with respect to location and amount of injectate, into vertebral body has been suggested based on evaluation of the insert positions and the insert shapes of injected PMMA. It is shown that vertebral body can be compensated most efficiently when PVIMA is highly concentrated on the top-front of trabecular bone of compressed vertebra.

Biomechanical Characteristics of Hand Rim Contact Orientation During Wheelchair Propulsion: A Literature Review (표준형 휠체어 추진시 휠손잡이 촉수위치 특성에 관한 연구)

  • Kwon, Hyuk-Cheol;Kong, Jin-Yong
    • Physical Therapy Korea
    • /
    • v.9 no.2
    • /
    • pp.19-32
    • /
    • 2002
  • The purpose of this paper is to provide the reader with a pertinent information and research trends of biomechanics in wheelchair propulsion. Biomechanical studies for wheelchair propulsion mainly focus on the most suitable propulsion performance and methods for preventing upper extremity injuries. Recent issues have concentrated on wheelchair propulsion style and cycle mainly because of the high prevalence of repetitive strain injuries in the upper extremely such as shoulder impingement and carpel tunnel syndrome. Optimizing wheelchair propulsion performances as well as medical reflections are presented throughout the review. Information on the underlying musculoskeletal mechanisms of wheelchair propulsion has been introduced through a combination of data collection under experimental conditions and a more fundamental mathematical modelling approach. Through a synchronized analysis of the movement pattern and muscular activity pattern, insight has been gained in the wheelchair propulsion dynamics of people with a different level of disability (various level of physical activity and functional potential). Through mathematical modelling simulation, and optimization (minimizing injury and maximizing performance), underlying musculoskeletal mechanisms during Wheelchair propulsion is investigated.

  • PDF

Floor Slipperiness Effect on the Biomechanical Study of Slips and Falls

  • Myung, Ro-Hae;Smith, James L.;Lee, Soon-Yo
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.22 no.3
    • /
    • pp.337-349
    • /
    • 1996
  • A study was conducted to find the possible relationship between slip distance and dynamic coefficient of friction (DCOF) through the biomechanical study of slips and falls using a broader variety of floors and levels of slipperiness than those used before. Four different floor surfaces covering the full range of floor slipperiness (with and without on oil contaminant) were prepared for ten subjects with each walking at a fixed velocity. The results showed that slip distance and heel velocity had a decreasing trend while stride length had a increasing trend as DCOF increased. The contaminant effect overpowered floor slipperiness effect because a higher DCOF surface with oil contaminant created longer slip distance than the lower DCOF with dry floor. Normal gait pattern and suggested heel velocity (10 to 20 cm/sec) were seen on dry floors but abnormally longer stride length and 5 to 10 times faster heel velocity were found an oily floors. In other words, faster heel velocity (greater than 10 to 20 cm/sec) is recommended to measure DCOF on oily floors because the assumption of normal gait was no longer valid.

  • PDF

The Study on Musculoskeletal Effects of Heel Types (구두 굽의 형태가 인체의 근골격계에 미치는 영향에 관한 연구)

  • Lee, Chang-Min;Jeong, Eun-Hui
    • Journal of the Ergonomics Society of Korea
    • /
    • v.23 no.1
    • /
    • pp.39-48
    • /
    • 2004
  • In terms of women engaged in clerical job. working time of the workers who mainly keep standing with their high-heeled shoes on has been increasing. According]y. they are exposed to many kinds of foot deformation caused by loads of lower back and lower extremities due to high-heeled shoes. The type of heels they usually wear are diverse though the hight is same. In this study. we investigated most women's favorite styles of shoes concerned with heights. types and contact areas of the heels. Hence. we designed three kinds of shoes for an experiment: their contact areas with ground are 1 cm2. 2-4 cm2 and over 9 cm2 according to the heel heights. respectively. To investigate the biomechanical effects. analysis of motion and EMG were applied to the experiments. In addition. foot pressure distribution was measured for more detailed analysis. Six healthy young women were participated in this experiments. The result showed the heel becoming higher and narrower increased not only fluctuation of CBM(Center of Body Mass). but also the load of low back muscle and lower extremities. Accordingly. there was significant difference among types of the heel in terms of the role supporting load of the body. though the height is same. Especially. the difference among the pressures on a foot was most significant. In conclusion. we verified biomechanical effects are related with the contact area of a heel with ground as well as the hight.

The Comparison of Biomechanical Changes between Spinous Process Osteotomy and Conventional Laminectomy (극돌기 절골술과 추궁판 절제술에 대한 생체역학적 비교)

  • Kang, Kyoung-Tak;Chun, Heoung-Jae;Son, Ju-Hyun;Kim, Ho-Joong;Moon, Seong-Hwan;Lee, Hwan-Mo;Kim, Ka-Yeon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.7
    • /
    • pp.645-651
    • /
    • 2009
  • Previous studies have introduced the technique of spinous process osteotomy to decompress spinal stenosis, a procedure which aims to afford excellent visualization while minimizing destruction of tissues not directly involved in the pathologic process. However, biomechanically it has not been investigated whether the sacrifice of posterior spinous process might have potential risk of spinal instability or not, even though supra-spinous and inter-spinous ligaments are preserved. Therefore the aim of this study is to evaluate the biomechanical properties after spinous process osteotomy, using finite element analysis. The model of spinous process osteotomy exhibited no significant increase in disc stress or change in segmental range of motion. It is due to the fact that the instability of lumbar spine has been maintained by the two-types of ligaments compared with the prior surgical technique. Therefore, according to the finite element result on this study, this osotetomy was considered to be a clinically safe surgical procedure and could not cause the instability of the lumbar spine.