• Title/Summary/Keyword: BIOMECHANICAL

Search Result 954, Processing Time 0.03 seconds

Effects of a Notebook Computer Supporter on Biomechanical Characteristics in Wrist Joint Muscles of Healthy Young Adults (노트북 거치대가 건강한 젊은 성인 손목관절근육의 생체역학적 특징에 미치는 영향)

  • Ma, Sung-Ryong;Song, Chiang-Soon
    • PNF and Movement
    • /
    • v.19 no.3
    • /
    • pp.391-399
    • /
    • 2021
  • Purpose: As laptop use increases throughout the COVID-19 pandemic and its use outside of traditional workstations proliferates, it is imperative to expand the limited research available regarding ergonomic exposure. This study aimed to identify the effects of a laptop supporter on biomechanical characteristics in the wrist joint muscles of healthy young adults. Methods: This was a cross-sectional observational study design with thirty-four healthy young adults as participants. They conducted a typing exercise performed under two different conditions, which were with and without a notebook computer supporter. This study measured the biomechanical characteristics of the muscles of the wrist joints including the flexor carpi ulnaris (FCU), the flexor carpi radialis (FCR), the extensor carpi radialis longus (ECRL), and the extensor carpi ulnaris (ECU). Measurements were taken three times: before typing, immediately after typing for 30 minutes with a supporter, and immediately after typing for 30 minutes without a supporter. The statistical method to compare the three different measurement conditions was the repeated measures ANOVA. Results: The participants showed significantly different levels of dynamic stiffness in both the FCU before typing and immediately after 30 minutes of typing with a supporter, and showed significantly different levels of dynamic stiffness in the FCR before typing and immediately after 30 minutes of typing with a supporter. The dynamic stiffness level immediately after 30 minutes of typing without a supporter was significantly different than that immediately after 30 minutes of typing with a supporter. However, the muscle tone was not significantly different among the three different conditions. Conclusion: The results of this study revealed that a laptop supporter used to correct the eye level of the electronic screen increases the dynamic stiffness of the wrist joint flexors, so it is necessary to consider the neutral position of the wrist joint during typing.

Prevalence of Low Back Pain and Associated Risk Factors among Farmers in Jeju

  • Lee, Hyun Jung;Oh, Jung-Hwan;Yoo, Jeong Rae;Ko, Seo Young;Kang, Jeong Ho;Lee, Sung Kgun;Jeong, Wooseong;Seong, Gil Myeong;Kang, Chul Hoo;Song, Sung Wook
    • Safety and Health at Work
    • /
    • v.12 no.4
    • /
    • pp.432-438
    • /
    • 2021
  • Background: We aimed to investigate the prevalence of low back pain (LBP) and its associated agricultural work-related, biomechanical factors among this population. Methods: We analyzed initial survey data from the Safety for Agricultural Injury of Farmers cohort study involving adult farmers in Jeju Island. The prevalence of LBP was calculated with associated factors. Results: In total, 1,209 participants were included in the analysis. The overall prevalence of LBP was 23.7%. Significant associations for LBP were the type of farming activity, length of farming career, prior agricultural injury within 1 year, and stress levels. Multivariate logistic regression analysis revealed three biomechanical factors significantly related to LBP: repetitive use of particular body parts; the inappropriate posture of the lower back and neck. Conclusions: Some occupational, and biomechanical risk factors contribute to LBP. Therefore, postural education, injury prevention education, and psychological support will be needed to prevent LBP.

Biomechanical Analysis of Biodegradable Cervical Plates Developed for Anterior Cervical Discectomy and Fusion

  • Cho, Pyung Goo;Ji, Gyu Yeul;Park, Sang Hyuk;Shin, Dong Ah
    • Asian Spine Journal
    • /
    • v.12 no.6
    • /
    • pp.1092-1099
    • /
    • 2018
  • Study Design: In-vitro biomechanical investigation. Purpose: To evaluate the biomechanical effects of the degeneration of the biodegradable cervical plates developed for anterior cervical discectomy and fusion (ACDF) on fusion and adjacent levels. Overview of Literature: Biodegradable implants have been recently introduced for cervical spine surgery. However, their effectiveness and safety remains unclear. Methods: A linear three-dimensional finite element (FE) model of the lower cervical spine, comprising the C4-C6 vertebrae was developed using computed tomography images of a 46-year-old woman. The model was validated by comparison with previous reports. Four models of ACDF were analyzed and compared: (1) a titanium plate and bone block (Tita), (2) strong biodegradable plate and bone block (PLA-4G) that represents the early state of the biodegradable plate with full strength, (3) weak biodegradable plate and bone block (PLA-1G) that represents the late state of the biodegradable plate with decreased strength, and (4) stand-alone bone block (Bloc). FE analysis was performed to investigate the relative motion and intervertebral disc stress at the surgical (C5-C6 segment) and adjacent (C4-C5 segment) levels. Results: The Tita and PLA-4G models were superior to the other models in terms of higher segment stiffness, smaller relative motion, and lower bone stress at the surgical level. However, the maximal von Mises stress at the intervertebral disc at the adjacent level was significantly higher in the Tita and PLA-4G models than in the other models. The relative motion at the adjacent level was significantly lower in the PLA-1G and Bloc models than in the other models. Conclusions: The use of biodegradable plates will enhance spinal fusion in the initial stronger period and prevent adjacent segment degeneration in the later, weaker period.

Glucosamine Hydrochloride and N-Acetylglucosamine Influence the Response of Bovine Chondrocytes to TGF-β3 and IGF in Monolayer and Three-Dimensional Tissue Culture

  • Pizzolatti, Andre Luiz A.;Gaudig, Florian;Seitz, Daniel;Roesler, Carlos R.M.;Salmoria, Gean Vitor
    • Tissue Engineering and Regenerative Medicine
    • /
    • v.15 no.6
    • /
    • pp.781-791
    • /
    • 2018
  • BACKGROUND: Glucosamine hydrochloride (GlcN HCl) has been shown to inhibit cell growth and matrix synthesis, but not with N-acetyl-glucosamine (GlcNAc) supplementation. This effect might be related to an inhibition of critical growth factors (GF), or to a different metabolization of the two glucosamine derivatives. The aim of the present study was to evaluate the synergy between GlcN HCl, GlcNAc, and GF on proliferation and cartilage matrix synthesis. METHOD: Bovine chondrocytes were cultivated in monolayers for 48 h and in three-dimensional (3D) chitosan scaffolds for 30 days in perfusion bioreactors. Serum-free (SF) medium was supplemented with either growth factors (GF) $TGF-{\beta}$ ($5ng\;mL^{-1}$) and IGF-I ($10ng\;mL^{-1}$), GlcN HCl or GlcNAc at 1mM each or both. Six groups were compared according to medium supplementation: (a) SF control; (b) SF + GlcN HCl; (c) SF + GlcNAc; (d) SF + GF; (e) SF + GF + GlcN HCl; and (f) SF + GF + GlcNAc. Cell proliferation, proteoglycan, collagen I (COL1), and collagen II (COL2) synthesis were evaluated. RESULTS: The two glucosamines showed opposite effects in monolayer culture: GlcN HCl significantly reduced proliferation and GlcNAc significantly augmented cellular metabolism. In the 30 days 3D culture, the GlcN HCl added to GF stimulated cell proliferation more than when compared to GF only, but the proteoglycan synthesis was smaller than GF. However, GlcNAc added to GF improved the cell proliferation and proteoglycan synthesis more than when compared to GF and GF/GlcN HCl. The synthesis of COL1 and COL2 was observed in all groups containing GF. CONCLUSION: GlcN HCl and GlcNAc increased cell growth and stimulated COL2 synthesis in long-time 3D culture. However, only GlcNAc added to GF improved proteoglycan synthesis.

Science of Falling and Injury in Older Adults - Do All Falls Lead to Death?: Literature Review (노인 낙상 - 넘어짐 그리고 인체손상의 과학, 넘어지면 다 죽는가?: 문헌 고찰)

  • Choi, Woochol Joseph;Lim, Kitaek;Kim, Seung-su;Lee, Se-young
    • Physical Therapy Korea
    • /
    • v.28 no.3
    • /
    • pp.161-167
    • /
    • 2021
  • Understanding sciences behind fall-related hip fractures in older adults is important to develop effective interventions for prevention. The aim of this review is to provide biomechanical understanding and prevention strategies of falls and related hip fractures in older adults, in order to guide future research directions from biomechanical perspectives. While most hip fractures are due to a fall, a few of falls are injurious causing hip fractures, and most falls are non-injurious. Fall mechanics are important in determining injurious versus non-injurious falls. Many different biomechanical factors contribute to the risk of hip fracture, and effects of each individual factors are known well. However, combining effects, and correlation and causation among the factors are poorly understood. While fall prevention interventions include exercise, vision correction, vitamin D intake and environment modification, injury prevention strategies include use of hip protectors, compliant flooring and safe landing strategies, vitamin D intake and exercise. While fall risk assessments have well been established, limited efforts have been made for injury risk assessments. Better understanding is necessary on the correlation and causation among factors affecting the risk of falls and related hip fractures in older adults. Development of the hip fracture risk assessment technique is required to establish more efficient intervention models for fall-related hip fractures in older adults.

Short-Term Clinical Effects of Robot-Assisted Gait Training Applied to Patients Undergoing Lower Extremity Surgery: A Pilot Study (하지 수술환자에게 적용한 로봇보조 보행훈련의 단기간 임상적 효과: 예비 연구)

  • Lee, Ha-Min;Kwon, Jung-Won
    • PNF and Movement
    • /
    • v.20 no.2
    • /
    • pp.295-306
    • /
    • 2022
  • Purpose: This study aimed to investigate the effect of robot-assisted gait training on the active ranges of motion, gait abilities, and biomechanical characteristics of gait in patients who underwent lower extremity surgery, and to verify the effectiveness and clinical usefulness of robot-assisted gait training. Methods: This study was conducted on 14 subjects who underwent lower extremity surgery. The subjects participated in robot-assisted gait training for 2 weeks. The active ranges of motion of the lower extremities were evaluated, and gait abilities were assessed using 10-m and 2-min walk tests. An STT Systems Inertial Measurement Unit was used to collect data on biomechanical characteristics during gait. Spatiotemporal parameters were used to measure cadence, step length, and velocity, and kinematic parameters were used to measure hip and knee joint movement during gait. Results: Significant improvements in the active ranges of motion of the hip and knee joints (flexion, extension, abduction, and adduction) and in the 10-m and 2-min walk test results were observed after robot-assisted gait training (p < 0.05). In addition, biomechanical characteristics of gait, spatiotemporal factors (cadence, step length, and velocity), and kinematic factors (gait hip flexion-extension, internal rotation-external rotation angle, and knee joint flexion-extension) were also significantly improved (p < 0.05). Conclusion: The results of this study are of clinical importance as they demonstrate that robot-assisted gait training can be used as an effective intervention method for patients who have undergone lower extremity surgery. Furthermore, the findings of this study are clinically meaningful as they expand the scope of robot-assisted gait training, which is currently mainly applied to patients with central nervous system conditions.

Biomechanical analysis for different mandibular total distalization methods with clear aligners: A finite element study

  • Sewoong Oh;Youn-Kyung Choi;Sung-Hun Kim;Ching-Chang Ko;Ki Beom Kim;Yong-Il Kim
    • The korean journal of orthodontics
    • /
    • v.53 no.6
    • /
    • pp.420-430
    • /
    • 2023
  • Objective: The purpose of this finite element method (FEM) study was to analyze the biomechanical differences and tooth displacement patterns according to the traction direction, methods, and sites for total distalization of the mandibular dentition using clear aligner treatment (CAT). Methods: A finite element analysis was performed on four FEM models using different traction methods (via a precision cut hook or button) and traction sites (mandibular canine or first premolar). A distalization force of 1.5 N was applied to the traction site by changing the direction from -30 to +30° to the occlusal plane. The initial tooth displacement and von Mises stress on the clear aligners were analyzed. Results: All CAT-based total distalization groups showed an overall trend of clockwise or counterclockwise rotation of the occlusal plane as the force direction varied. Mesiodistal tipping of individual teeth was more prominent than that of bodily movements. The initial displacement pattern of the mandibular teeth was more predominant based on the traction site than on the traction method. The elastic deformation of clear aligners is attributed to unintentional lingual tipping or extrusion of the mandibular anterior teeth. Conclusions: The initial tooth displacement can vary according to different distalization strategies for CAT-based total distalization. Discreet application and biomechanical understanding of traction sites and directions are necessary for appropriate mandibular total distalization.

Relationship between Foot Morphology and Biomechanical Variables of the Lower Extremity Joints during Vertical Jump (수직점프 시 발의 형태학적 특징과 하지관절의 운동역학적 변인과의 관계)

  • Seong Hun Park;Sang-Kyoon Park
    • Korean Journal of Applied Biomechanics
    • /
    • v.34 no.2
    • /
    • pp.45-52
    • /
    • 2024
  • Objective: The purpose of this study was to measure the morphological characteristics of the foot and biomechanical variables of the lower extremity joints during vertical jump and investigate the relationship between foot morphology and biomechanics of vertical jump. Method: 24 men in their 20s (age: 22.42 ± 1.41 yrs, height: 173.37 ± 4.61 cm, weight: 72.02 ± 6.21 kg, foot length: 251.70 ± 8.68 mm) participated in the study. Morphological characteristics of the foot included the length of the first toe, the length of the second toe, and the horizontal length from the center of ankle joint to the achilles tendon (Plantar Flexion Moment Arm [PFMA]). Biomechanical variables were measured for plantar flexor strength of the ankle joint and peak angular velocity, moment, and power of the lower extremity joint during vertical jump. Results: There was a significant correlation between the length of the first toe and plantar flexion strength at 30°/s [r=.440, p=.016], the angular velocity of the metatarsophalangeal [MTP] joint [r=-.369, p=.038] while significant correlations between PFMA and the angular velocities of the knee joint [r=.369, p=.038] and ankle joint [r=.420, p=.021] were found. There were also significant correlations between the length of the first toe and the maximum moment of the hip joint [r=.379, p=.034], and the length of the second toe and the power of the hip joint [r=-.391, p=.029]. Finally, significant correlations between PFMA and the power of the ankle joint [r=.424, p=.019] and MTP joint [r=.367, p=.039] were found. Conclusion: Based on the results of this study, the length of the toe and PFMA would be related to the function of the lower extremity joint. Therefore, this should be considered when designing the functional structure of a shoe. Furthermore, this relationship can be applied to intensive training for the plantar flexors and toe flexors to improve power in athletic performance.

The Effects of Chair Height and Foot Condition on the Biomechanical Factors in Sit-to-Stand Movement of Hemiplegic Patients (편마비 환자의 앉은 자세에서 일어서기 동작 시 의자 높이와 발의 조건이 생체역학적 요소에 미치는 영향)

  • Kim, Dong-hoon;Kim, Tack-hoon;Choi, Houng-sik;Roh, Jung-suk;Choi, Kyu-hwan;Kim, Ki-song
    • Physical Therapy Korea
    • /
    • v.25 no.2
    • /
    • pp.1-12
    • /
    • 2018
  • Background: It is very difficult for hemiplegic patients to effectively perform the sit-to-stand (STS) movements independently because of several factors. Moreover, the analysis of STS motion in hemiplegic patients has been thus far confined to only muscle strength evaluation with little information available on structural and environmental factors of varying chair height and foot conditions. Objects: This study aimed to analyze the change in biomechanical factors (ground reaction force, center of mass displacement, and the angle and moment of joints) of the joints in the lower extremities with varying chair height and foot conditions in hemiplegic patients while they performed the STS movements. Methods: Nine hemiplegic patients voluntarily participated in this study. Their STS movements was analyzed in a total of nine sessions (one set of three consecutive sessions) with varying chair height and foot conditions. The biomechanical factors of the joints in the lower extremities were measured during the movements. Ground reaction force was measured using a force plate; and the other abovementioned parameters were measured using an infra-red camera. Two-way repeated analysis of variance was performed to determine the changes in biomechanical factors in the lower extremities with varying chair height and foot conditions. Results: No interaction was found between chair height and foot conditions (p>.05). All measured variables with varying chair height showed a significant difference (p<.05). Maximum joint flexion angle, maximum joint moment, and the displacement of the center of mass in foot conditions showed a significant difference (p<.05); however the maximum ground reaction force did not show a significant difference (p>.05). Conclusion: The findings suggest that hemiplegic patients can more stably and efficiently perform the STS movement with increased chair height and while they are bare-foot.

Biomechanical Analysis of Lower Limbs on Speed of Nordic Walking (노르딕워킹의 속도에 따른 하지 관절의 운동역학적인 분석)

  • Yang, Dae-Jung;Lee, Yong-Seon;Park, Seung-Kyu;Kang, Jeong-Il;Lee, Joon-Hee;Kang, Yang-Hoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.21 no.3
    • /
    • pp.383-390
    • /
    • 2011
  • In this study, 26 normal subjects were studied to compare the biomechanical Analysis of Lower Limbs on Speed of Nordic Walking. The biomechanical variables were determined by performing three-dimensional gait analysis, and the measurements items were spatial and temporal parameters; vertical ground reaction force; and moments of the hip, knee, and ankle joints. The purpose of this study based on the speed of Nordic Walking to the vertical ground reaction force and joint moments of each were analyzed. Nordic Walking with poles while being whether this weight is reduced to load, not the improvement of muscle activity by identify Nordic walking is to allow efficient. The results of the analysis were follows. The spatial parameters of step length, stride length significantly increased with increase in velocity(p<0.001). The temporal parameters of step time, stride time, the duration of double support use, and the duration of single support use also significantly decreased with increase in velocity(p<0.001), but cadence significantly increased(p<0.01). Analysis of the changes in ground reaction force revealed that vertical ground reaction force significantly increased at the initial contact and the terminal stance and decreased at the mid stance with increase in velocity(p<0.001). Moments of the hip and knee joints significantly in creased with increase in velocity whereas that of the ankle joint did not. Gait analysis revealed that weight-bearing decreased and moments of the hip and knee joints increased with increase in velocity(p<0.01). The results of this study may help people perform Nordic walking efficiently and Nordic walking can be used in the gait training of people with an abnormal gait.