• 제목/요약/키워드: BEAMnrc

검색결과 8건 처리시간 0.02초

Evaluation of electron dose distribution obtained from ADAC Pinnacle system against measurement and Monte Carlo method for breast patients

  • Lee, S.;Lee, R.;Park, D.;S. Suh
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2003년도 제27회 추계학술대회
    • /
    • pp.82-82
    • /
    • 2003
  • Introduction: With the development of dose calculation algorithms for electron beams, 3D RTP systerns are available for electron beam dose distribution commercially. However, no studies evaluated the accuracy of dose calculation with ADAC Pinnacle system for electron beams. So, the accuracy of the ADAC system is investigated by comparing electron dose distributions from ADAC system against the BEAMnrc/DOSXYZnrc. Methods: A total of 33 breast cancer patients treated with 6, 9, and 12MeV electrons in our institution was selected for this study. The first part of this study is to compare the dose distributions of measurement, TPS and the BEAMnrc/DOSXYZnrc code in flat water phantom at gantry zero position and for a 10 ${\times}$ 10 $\textrm{cm}^2$ field. The second part is to evaluate the monitor unit obtained from measurement and TPS. Adding actual breast patient's irregular blocks to the first part, monitor units to deliver 100 cGy to the dose maximum (dmax) were calculated from measurement and 3D RTP system. In addition, the dose distributions using blocks were compared between TPS and the BEAMnrc/DOSXYZnrc code. Finally, the effects of tissue inhomogeneities were studied by comparing dose distributions from Pinnacle and Monte Carlo method on CT data sets. Results: The dose distributions calculated using water phantom by the TPS and the BEAMnrc/ DOSXYZnrc code agreed well with measured data within 2% of the maximum dose. The maximum differences of monitor unit between measured and Pinnacle TPS in flat water phantom at gantry zero position were 4% for 6 MeV and 2% for 9 and 12 MeV electrons. In real-patient cases, comparison of depth doses and lateral dose profiles calculated by the Pinnacle TPS, with BEAMnrc/DOSXYZnrc code has generally shown good agreement with relative difference less than +/-3%. Discussion: For comparisons of real-patient cases, the maximum differences between the TPS and BEAMnrc/DOSXYZnrc on CT data were 10%. These discrepancies were due in part to the inaccurate dose calculation of the TPS, so that it needs to be improved properly. Conclusions: On the basis of the results presented in this study, we can conclude that the ADAC Pinnacle system for electron beams is capable of giving results absolutely comparable to those of a Monte Carlo calculation.

  • PDF

분산 감소 기법에 의한 몬테칼로 선량 계산 효율 평가 (Application of Variance Reduction Techniques for the Improvement of Monte Carlo Dose Calculation Efficiency)

  • 박창현;박성용;박달
    • 한국의학물리학회지:의학물리
    • /
    • 제14권4호
    • /
    • pp.240-248
    • /
    • 2003
  • 몬테칼로 계산은 다른 어떤 알고리즘보다 정확한 선량 계산 결과를 주지만 계산 시간이 오래 걸리는 단점이 있다. 본 연구에서는 Varian 600 C/D 선형가속기로부터지 6 MV 광자선에 대해 몬테칼로 계산을 사용하여 얻은 선량 분포가 측정에 의해 얻은 선량 분포와 2% 이내에서 서로 잘 일치하도록 하며 분산 감소 기법을 사용하여 계산 시간 단축 정도를 평가하였다. 그리고 연산 능력을 높여 계산 시간 단축 정도를 평가하여 분산 감소 기법을 사용한 경우와 연산 능력을 높인 경우 간에 계산 시간 단축 정도를 비교하였다. 몬테칼로 계산 코드로는 빔 모사를 위해 BEAMnrc 코드, 선량 계산을 위해 DOSXYZnrc 코트를 각각 사용하였는데 분산 감소 기법은 이 코드들에서 지원하는 방법들을 사용하였고 연산 능력을 높이는 방법으로는 컴퓨터 클러스터를 이용한 병렬 처리를 사용하였다. 비교 결과, 분산 감소 기법을 사용하여 계산 시간을 최대 1/25 이상 단축시킬 수 있었고 9대의 컴퓨터를 이용한 병렬 처리 결과 계산 시간을 1/9로 단축시킬 수 있었다. 계산 곁과의 정확성을 만족할 만한 수준으로 유지할 수 있다면 분산감소 기법을 포함한 간략화된 물리의 적용은 현 시점에서 몬테칼로 선량 계산 시간을 획기적으로 단축시킬 대안이 될 수 있다.

  • PDF

방사선 치료를 위한 몬테칼로 광자선 선량계산 시 통계적 불확실성 영향 평가 (The Effects of the Statistical Uncertainties in Monte Carlo Photon Dose Calculation for the Radiation Therapy)

  • 정광호;서태석;조병철
    • Journal of Radiation Protection and Research
    • /
    • 제29권2호
    • /
    • pp.105-115
    • /
    • 2004
  • 몬테칼로 모의실험을 이용하여 방사선 선량을 계산할 경우 원하는 정확도를 얻기 위해서는 계산입자(histories) 수가 많아야 하므로 시간이 오래 걸리게 된다. 그러므로 정확성을 유지할 수 있으면서 시간을 최소화할 수 있는 최적의 계산입자 수를 결정해야 할 필요가 있다. 본 연구에서는 계산입자 수에 따른 통계적 불확실성의 영향을 평가한 후 최적의 계산입자 수 결정을 위한 불확실성의 한계를 제시하고자 하였다. 몬테칼로 코드로는 BEAMnrc와 DOSXYZnrc를 사용하였으며, 모의 흉부 팬텀에 대하여 계산입자 수를 달리 하면서 광자선 선량을 계산한 후 통계적 오차가 적은 벤치마크와 비교하였다. 통계적 오차의 영향을 분석하기 위하여 임상적으로 널리 이용되는 등선량 곡선 비교, DVH, RMSD 방법을 이용하였다. 연구 결과 통계적 오차의 영향은 등산량 곡선 비교와 RMSD 비교에서 크게 나타났으나 DVH에서의 영향은 크지 않은 것으로 나타났다. 방사선치료를 위한 광자선 선량계산을 할 경우 전체 통계적 불확실성 $(\bar{{\Delta}D})$ 9% 또는 $D_{max}/2$ 이상을 갖는 체적소에 대한 통계적 오차 1%, 또는 최대 선량지점에서의 통계적 불확실성 1% 정도가 적정 수준임을 확인할 수 있었다.

Dosimetric Characteristics of 6 MV Modified Beams by Physical Wedges of a Siemens Linear Accelerator

  • Zabihzadeh, Mansour;Birgani, Mohammad Javad Tahmasebi;Hoseini-Ghahfarokhi, Mojtaba;Arvandi, Sholeh;Hoseini, Seyed Mohammad;Fadaei, Mahbube
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권4호
    • /
    • pp.1685-1689
    • /
    • 2016
  • Physical wedges still can be used as missing tissue compensators or filters to alter the shape of isodose curves in a target volume to reach an optimal radiotherapy plan without creating a hotspot. The aim of this study was to investigate the dosimetric properties of physical wedges filters such as off-axis photon fluence, photon spectrum, output factor and half value layer. The photon beam quality of a 6 MV Primus Siemens modified by 150 and 450 physical wedges was studied with BEAMnrc Monte Carlo (MC) code. The calculated present depth dose and dose profile curves for open and wedged photon beam were in good agreement with the measurements. Increase of wedge angle increased the beam hardening and this effect was more pronounced at the heal region. Using such an accurate MC model to determine of wedge factors and implementation of it as a calculation algorithm in the future treatment planning systems is recommended.

Photon dose calculation of pencil beam kernel based treatment planning system compared to the Monte Carlo simulation

  • Cheong, Kwang-Ho;Suh, Tae-Suk;Kim, Hoi-Nam;Lee, Hyoung-Koo;Choe, Bo-Young;Yoon, Sei-Chul
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.291-293
    • /
    • 2002
  • Accurate dose calculation in radiation treatment planning is most important for successful treatment. Since human body is composed of various materials and not an ideal shape, it is not easy to calculate the accurate effective dose in the patients. Many methods have been proposed to solve the inhomogeneity and surface contour problems. Monte Carlo simulations are regarded as the most accurate method, but it is not appropriate for routine planning because it takes so much time. Pencil beam kernel based convolution/superposition methods were also proposed to correct those effects. Nowadays, many commercial treatment planning systems, including Pinnacle and Helax-TMS, have adopted this algorithm as a dose calculation engine. The purpose of this study is to verify the accuracy of the dose calculated from pencil beam kernel based treatment planning system Helax-TMS comparing to Monte Carlo simulations and measurements especially in inhomogeneous region. Home-made inhomogeneous phantom, Helax-TMS ver. 6.0 and Monte Carlo code BEAMnrc and DOSXYZnrc were used in this study. Dose calculation results from TPS and Monte Carlo simulation were verified by measurements. In homogeneous media, the accuracy was acceptable but in inhomogeneous media, the errors were more significant.

  • PDF

몬데카를로 기반 치료계획시스템의 성능평가 (Benchmark Results of a Monte Carlo Treatment Planning system)

  • Cho, Byung-Chul
    • 한국의학물리학회지:의학물리
    • /
    • 제13권3호
    • /
    • pp.149-155
    • /
    • 2002
  • 최근 들어 방사선 수송이론, 컴퓨터 하드웨어 성능, 및 병렬 연산 기법의 발전에 힘입어, 몬테카를로 기반의 선량계산 기법을 임상에 적용할 수 있게 되었다. 임상적용을 위해 개발된 몬테카를로 기반 선량계산 코드간의 계산 소요 시간과 정확도를 비교할 목적으로 제13차 ICCR (International Conference on the use of Computers in Radiation Therapy, Heidelberg, Germany, 2000) 학술대회에서 벤치마킹 절차서가 제안되었다. 최근, 본원에서도 임상적용을 목표로 28개의 인텔 펜티움 프로세서로 구성된 Linux cluster 시스템을 구축하고, 여기에 몬테카를로 선량계산을 위한 BEAMnrc 코드를 설치하였다. 본 연구의 목적은 위에서 제안된 벤치마킹 절차를 수행하여 본원에서 구축한 몬테카를로 선량계산 시스템의 정량적 성능 평가를 시도하고자 하는 것이었다. 벤치마킹 절차는 크게 다음의 세 과정으로 구성되어 있다. a) 30.5 cm $\times$ 39.5 cm $\times$ 30 cm 의 팬톰(5 ㎣ voxels) 에 대한 통계적 불확정도 2%이내 결과를 얻기 위한 광자선 선량계산 속도. b) 위 팬톰에 대한 전자선의 선량계산 속도. c) 비균질 평판 매질로 구성된 팬톰내 광자선 및 전자선의 선량계산 결과를 EGSr/PRESTA 계산 결과와 비교 제시. 18 MV 광자선에 대해 선량계산 속도 평가 결과 5.5분이 소용되었다. 전자선의 경우, 실제 계산 시간은 광자선에 비해 약 10배 정도 빨랐으나, 병렬 연산을 처리하기 위해 소용되는 추가 시간 때문에 전체 계산에 소요되는 시간은 광자선과 비슷하였다. 본 원에서 사용한 몬테카를로 코드는 EGSnrc로써 EGS4의 개선 버전으로 이들 간의 정확도 비교는 큰 의미가 없을 것으로 판단된다. 하지만 두 계산 결과가 기대했던 바와 같이 매우 잘 일치하였다. 결론적으로, 본원에서 구축한 몬테카를로 치료계획시스템은 임상적용에 무리가 없을 것으로 판단하였다. 추후 본 시스템을 본원에서 사용하는 상용 치료계획시스템과 인터페이스를 개발하여, 통합환경을 구축함으로써, 몬테카를로 기반의 치료계획시스템의 임상적용과 관련된 연구들을 수행해 나갈 계획이다.

  • PDF