• Title/Summary/Keyword: B1 field

Search Result 2,602, Processing Time 0.03 seconds

Improvement of Field Uniformity in a Reverberation Chamber with Various Numbers of a 2D CRD (2D CRD 수에 따른 전자파 잔향실 내의 필드 균일성 개선)

  • Kim, Jin-Bok;Rhee, Joong-Geun;Kim, Jung-Hoon;Rhee, Eu-Gene
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.47 no.4
    • /
    • pp.18-24
    • /
    • 2010
  • This paper presents the improvement of the field uniformity in a reverberation chamber which can be substitute an anechoic chamber for the electromagnetic interference (EMI) and immunity test. Nowadays, there are many EMI issues due to the increasing use of wireless local area network (LAN), digital multimedia broadcasting (DMB), and mobile internet. With this reason, this paper studied the field characteristics in a reverberation chamber for 2.3 GHz band. In this paper, the finite difference time domain (FDTD) method is used to analyze the field characteristics in a reverberation chamber. To improve the field uniformity in the reverberation chamber, this paper adopted a 2D cubical residue diffuser (CRD) with varying the disposition and number of CRD. For each case, the tolerance and standard deviation of the electric field strength are evaluated. In comparison with the reverberation chamber without any CRD, the reverberation chamber with two CRDs showed improved results; 1.98 dB improvement in standard deviation and 3.6 dB improvement in tolerance.

Simultaneous Measurement of Velocity and Concentration Field in a Stirred Mixer Using PIV/LIF Technique (PIV/LIF기법에 의한 교반혼합기 내의 속도장과 농도장 동시 측정)

  • Jeong, Eun-Ho;Yoon, Sang-Youl;Kim, Kyung-Chun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.4
    • /
    • pp.504-510
    • /
    • 2003
  • Simultaneous measurements of turbulent velocity and concentration field in a stirred mixer tank are carried out by using PIV/LIF technique. Instantaneous velocity fields are measured with a 1K$\times$1K CCD camera adopting the frame straddle method while the concentration fields are obtained by measuring the fluorescence intensity of Rhodamine B tracer excited by the second pulse of Nd:Yag laser light. Image distortion due to the camera view-angle is compensated by a mapping function. It is found that the general features of the mixing pattern are quite dependent on the local flow characteristics during the rapid decay of mean concentration. However, the small scale mixing seems to be independent on the local turbulent velocity fluctuation.

Magnetic dependence of cyclotron resonance in the electron-piezoelectric phonon interacting materials

  • Park, Jung-Il;Sug, Joung-Young
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.24 no.1
    • /
    • pp.16-22
    • /
    • 2020
  • Based on quantum transport theory, we investigated theoretically the magnetic field dependence of the quantum optical transition of quasi 2-dimensional Landau splitting system, in CdS and ZnO Through the analysis of the current work, we found the increasing properties of the cyclotron resonance line-profiles (CRLPs) which show the absorption power and the cyclotron resonance line-widths (CRLWs) with the magnetic field in CdS and ZnO We also found that that CRLWs, γtotal(B) of CdS < γtotal(B) of ZnO in the magnetic field region B < 15 Tesla.

Performance verification of Ka-Band Array Antenna using Near-Field Test Method (근접전계 시험 기법을 활용한 Ka-대역 배열안테나 성능 검증)

  • Kim, Youngwan;Kwon, Junbeom;Kang, Yeonduk;Park, Jongkuk
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.4
    • /
    • pp.105-111
    • /
    • 2019
  • In this paper, a performance analysis of waveguide broad-wall slot array antenna for millimeter-wave seeker in Ka-band was performed as using near-field measurement. The measurement of slot array antenna was conducted in both far-field and near-field. And the validation of near-field test in millimeter band was confirmed. It was confirmed that the beam pattern characteristics including beam width and side lobe level of the slot array antenna that performed the verification were the same. Differenced in the side lobe level of azimuth and elevation beam pattern were verified to be less than 1dB. Additionally, the new antenna aperture distribution was extracted as using back-projection method modifying the near-field data and then introduced the method conducting performance analysis of array antenna.

Sensitivity Improvement of 3-D Hall Sensor using Anisotropic Etching and Ni/Fe Thin Films (트랜치 구조를 갖는 3차원 홀 센서의 감도 개선에 관한 연구)

  • 이지연;최채형
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.8 no.4
    • /
    • pp.17-23
    • /
    • 2001
  • The 3-D Hall sensor has two horizontal magnetic field sensing parts ($\chi$, y components) and one vertical magnetic field sensing part (z component). For conventional, 3-D Hall sensor it is general that the sensitivity for $B_{z}$ is about 1/10 compared with those for $B_\chi$ or $B_y$. Therefore, in this work, we proposed 3-D Hall sensor with new structure. We have increased the sensitivity about 6 times to form the trench using anisotropic etching. And we have increased the sensitivity for the $B_z$ by 80% compared with those of $B_\chi$ and$B_y$ using deposition of the ferromagnetic thin films on the bottom surface of the wafer to concentrate the magnetic fluxes. When the input current was 3 mA, sensitivities of the fabricated sensor with Ni/Fe film for $B_\chi, B_y$ and $B_{z}$ were measured as 120.1 mV/T, 111.7 mV/T, 95.3 mV/T, respectively. The measured linearity of the sensor was within $\pm$3% of error.

  • PDF

The Effect of Magnetic Field Treatment on Enhanced Exchange Coupling of $Nd_{2}Fe_{14}B/Fe_{3}B$ Magnet (자장중 열처리에 의한 $Nd_{2}Fe_{14}B/Fe_{3}B$ 초미세립 복합자성상의 자기특성 향상)

  • 박언병;양충진
    • Journal of the Korean Magnetics Society
    • /
    • v.6 no.2
    • /
    • pp.80-85
    • /
    • 1996
  • An externally applied magnetic field during annealing the $Nd_{2}Fe_{14}B/Fe_{3}B$ based spring magnet was found to enhance the exchange coupling between the hard and soft magnetic grains. More than 30 % increase in remanence values for melt-spun $Nd_{4}Fe_{73.5}Co_{3}(Hf_{1-x}-Ga_{x})B_{18.5}$(x=0, 0.5, 1.0) alloys was resulted from uniform distribution of $Fe_{3}B$, $\alpha$-Fe as well as $(Nd_{2}Fe_{14}B)$, and also from reduced grain size of those phases by 20 %. The result also showed that there is an optimum grain size exhibiting a high coercivity value which will be discussed in terms of previously simulated exchange coupling parameter.

  • PDF

A Study on the Optimized Measurements of Field Uniformity for Electromagnetic Radiated Immunity Test System (전자파 방사 내성 시험을 위한 최적화된 균일장 측정 방법에 관한 연구)

  • Cho Jin-Young;Mun Jun-Chul;Jung Chang-Kyoo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.6 s.97
    • /
    • pp.622-631
    • /
    • 2005
  • In this paper, we reduce 'over and under deviation' and 'over and under testing' which have a cause of uncertainty in electromagnetic radiated immunity test. We analyze continued measurement method of field uniformity and propose new estimate method having the minimum uncertainty condition. We test comparison in 4 anechoic chambers and analyze FDI(Field Deviation Index) which is the minimum deviation excess 6 dB on fields. We obtain that the proposed test method improve 1.193 dB than domestic standard(KN 61000-4-3) and 0.017 dB than international standard (IEC61000-4-3) in every frequency. In the test result 'over and under testing point' have 926 point at every field area and have 118 point at center uniform area. These result know that proposed measurement method have 10 point less at every field area and 9 point less at center uniform area than continued measurement method. The proposed test method have few point more than continued measurement method. Therefore, we confirmed that the proposed test method have the minimum uncertainty in electromagnetic radiated immunity test.

Magnetic Pinning Properties and Flux Jumps in Superconducting $MgB_2$

  • Yoon, W.S.;Lee, Eui-Wan;Kim, C.J.;Kim, B.G.;Ri, H.C.
    • Progress in Superconductivity
    • /
    • v.9 no.1
    • /
    • pp.11-17
    • /
    • 2007
  • Magnetization studies have been carried out on $MgB_2$ polycrystalline samples in the temperature range of 5 - 44 K and in the magnetic field up to 7 Tesla. The critical current density was calculated from hysteresis loops using the Bean's critical state model, and the highest value of $J_c$ at 20 K was $2.7{\times}10^5\;A/cm^2$ at 2 Tesla. The hysteresis loops were carefully examined to determine the temperature and magnetic field range where flux jumps appeared. The first jump occurred typically at 1 Tesla. Due to the strong pinning, we observed the presence of flux jump below H = 1 Tesla at temperature below 30 K.

  • PDF

Time-Multiplexed RF Transmission to Improve $B_1$ Homogeneity in High Field MRI

  • Han, Byung-Hee;Seo, Jeung-Hun;Heo, Hye-Young;Lee, Soo-Yeol
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.2
    • /
    • pp.99-106
    • /
    • 2008
  • To improve $B_1$ homogeneity in high field MRI, the RF power is applied to the transmit array coil elements sequentially in the time-multiplexed way. Since only a single coil element is activated in a time-multiplexing slot, the global standing wave formation in the human body is greatly suppressed. The time-multiplexing slot width is on the order of micro seconds, hence, high-order-harmonic slices can be placed far from the transmit coil and simultaneous multiple slice selection can be avoided. The $B_1$ homogeneities of a birdcage coil and an eight-channel transmit array coil have been compared through finite difference time domain simulations. The simulation results indicate that the proposed technique can reduce the peak-to-peak $B_1$ inhomogeneity down to one fourth of the transmission with a birdcage coil on the central plane of the human head model at 3 T. The mimicking experiments at 3 T, eight separate experiments with a single coil element activated and image reconstruction by combining the eight images, also show promising results. It is expected that the proposed technique has some advantages over other $B_1$ improving methods in real practice since simple RF switching circuitries are only necessary and electromagnetic coupling between the coil elements is out of concern in its realization.