• Title/Summary/Keyword: B-mode imaging

Search Result 63, Processing Time 0.033 seconds

Power Doppler ultrasound-guided sialography using the phenomenon of increased blood flow: A technical report

  • Oh, Song Hee;Seo, Yu-Kyeong;Kim, Gyu-Tae;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.49 no.4
    • /
    • pp.301-306
    • /
    • 2019
  • Purpose: This report presents a procedure for performing power Doppler ultrasound-guided sialography using the phenomenon of increased blood flow and illustrates its application to practical patient cases. Materials and Methods: The salivary gland was scanned using ultrasound equipment (GE LOGIQ5 Expert® device; GE Medical Systems, Milwaukee, WI, USA) to identify pathological findings related to the patient's chief complaint. To identify the orifice of the main duct, it should be cannulated using a lacrimal dilator. After inserting the catheter into the cannulated main duct, the position of the catheter within the duct was confirmed by ultrasound. A contrast agent was injected until the patient felt fullness, and ultrasound (B-mode) was used to confirm whether the contrast agent filled the main canal and secondary and tertiary ducts. Then, power Doppler ultrasound was performed to determine whether the salivary gland had increased blood flow. Results: In 2 cases in this report, a power Doppler ultrasound scan showed a significant increase in blood flow after contrast medium injection, which was not observed on a preoperative scan. Conclusion: Power Doppler ultrasound was found to be a simple, safe, and effective tool for real-time sialography monitoring.

Comparison of Muscle Architecture of Lower Extremity using Rehabilitative Ultrasound Image in Young Adults: a Comparative Study of Muscle Cross-sectional area of Lower Extermity of Seoul and Hanoi in Vietnam (재활 초음파 영상을 이용한 젊은 성인의 하지 근 구조 비교: 서울과 하노이 하지 근 단면적비교 연구)

  • Lee, Hwang-Jae;Kim, Min-Kyu;Ha, Hyun-Geun;Lee, Wan-Hee
    • The Journal of Korean Physical Therapy
    • /
    • v.26 no.5
    • /
    • pp.324-330
    • /
    • 2014
  • Purpose: The aim of the current study was to compare the muscle architecture of lower extremity using rehabilitative ultrasound imaging (RUSI) in young adults in Seoul and Hanoi. Methods: The study design was a comparative study of muscle cross-sectional area of lower extremity. Sixty healthy young subjects (Seoul group: 30, Hanoi group: 30) participated in this study. Real-time B-mode RUSI with a 7.5MHz linear transducer was used for measurement of cross-sectional area, pennation angle, and muscle thickness of the rectus femoris, tibialis anterior, and medial gastrocnemius muscles. Independent t-test was used for statistical analysis. Results: Significant difference in cross sectional area of rectus femoris was observed between Korean young adults and Hanoi young adults (p<0.01). Muscle thickness and pennation angle of tibialis anterior in Korean young adults were greater than in Hanoi young adults (p<0.01). In addition, the muscle thickness and pennation angle of the medial part of gastrocnemius muscle were greater in Korean young adults than in Hanoi young adults (p<0.01). In addition, in the results for gender, men had larger muscle architectures than women in both groups (p<0.01). Conclusion: This study, using RUSI, showed significant difference in muscle architectures of lower extremity in a diverse group of young adults RUSI.

Comparison of the Contraction Ratios of the Transversus Abdominis Muscle During the Abdominal Drawing-in Maneuver in the Hook-Lying, Sitting, and Standing Positions (무릎 구부리고 누운 자세, 앉은 자세, 선 자세에서 복부 드로잉-인 방법을 수행하는 동안 배가로근의 수축비 비교)

  • Won, Jong-Im
    • PNF and Movement
    • /
    • v.19 no.2
    • /
    • pp.215-223
    • /
    • 2021
  • Purpose: This study aimed to compare the contraction ratios of the abdominal muscles and the preferential activation ratios of the transversus abdominis muscle (TrA) during the abdominal drawing-in maneuver (ADIM) in the hook-lying, sitting, and standing positions. Methods: This study included 30 healthy participants. The thicknesses of the TrA, internal oblique muscle (IO), and external oblique muscle (EO) were measured at rest and during the ADIM in the hook-lying, sitting, and standing positions using B-mode ultrasound imaging. The contraction ratios of these muscles and the preferential activation ratios of the TrA were calculated for each position. Results: The contraction ratio of the TrA and preferential activation ratio of the TrA during the ADIM in the hook-lying position were significantly higher than those in the sitting and standing positions (p < 0.05). The contraction ratio of the TrA during the ADIM in the sitting position was significantly higher than that in the standing position (p < 0.05). Conclusion: The hook-lying position tended to facilitate TrA activity better than the sitting position. Furthermore, the sitting position tended to facilitate TrA activity better than the standing position. These findings suggest that the ADIM in the hook-lying position should be implemented before that in the sitting position and that the ADIM in the sitting position should be implemented before that in the standing position.

Reproducibility Evaluation of Deep inspiration breath-hold(DIBH) technique by respiration data and heart position analysis during radiation therapy for Left Breast cancer patients (좌측 유방암 환자의 방사선치료 중 환자의 호흡과 심장 위치 분석을 통한 Deep inspiration breath-hold(DIBH) 기법의 재현성 평가)

  • Jo, Jae Young;Bae, Sun Myung;Yoon, In Ha;Lee, Ho Yeon;Kang, Tae Young;Baek, Geum Mun;Bae, Jae Beom
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.297-303
    • /
    • 2014
  • Purpose : The purpose of this study is reproducibility evaluation of deep inspiration breath-hold(DIBH) technique by respiration data and heart position analysis in radiation therapy for Left Breast cancer patients. Materials and Methods : Free breathing(FB) Computed Tomography(CT) images and DIBH CT images of three left breast cancer patients were used to evaluate the heart volume and dose during treatment planing system( Eclipse version 10.0, Varian, USA ). The signal of RPM (Real-time Position Management) Respiratory Gating System (version 1.7.5, Varian, USA) was used to evaluate respiration stability of DIBH during breast radiation therapy. The images for measurement of heart position were acquired by the Electronic portal imaging device(EPID) cine acquisition mode. The distance of heart at the three measuring points(A, B, C) on each image was measured by Offline Review (ARIA 10, Varian, USA). Results : Significant differences were found between the FB and DIBH plans for mean heart dose (6.82 vs. 1.91 Gy), heart $V_{30}$ (68.57 vs. $8.26cm^3$), $V_{20}$ (76.43 vs. $11.34cm^3$). The standard deviation of DIBH signal of each patient was ${\pm}0.07cm$, ${\pm}0.04cm$, ${\pm}0.13cm$, respectively. The Maximum and Minimum heart distance on EPID images were measured as 0.32 cm and 0.00 cm. Conclusion : Consequently, using the DIBH technique with radiation therapy for left breast cancer patients is very useful to establish the treatment plan and to reduce the heart dose. In addition, it is beneficial to using the Cine acquisition mode of EPID for the reproducibility evaluation of DIBH.

Principal component analysis in C[11]-PIB imaging (주성분분석을 이용한 C[11]-PIB imaging 영상분석)

  • Kim, Nambeom;Shin, Gwi Soon;Ahn, Sung Min
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.12-16
    • /
    • 2015
  • Purpose Principal component analysis (PCA) is a method often used in the neuroimagre analysis as a multivariate analysis technique for describing the structure of high dimensional correlation as the structure of lower dimensional space. PCA is a statistical procedure that uses an orthogonal transformation to convert a set of observations of correlated variables into a set of values of linearly independent variables called principal components. In this study, in order to investigate the usefulness of PCA in the brain PET image analysis, we tried to analyze C[11]-PIB PET image as a representative case. Materials and Methods Nineteen subjects were included in this study (normal = 9, AD/MCI = 10). For C[11]-PIB, PET scan were acquired for 20 min starting 40 min after intravenous injection of 9.6 MBq/kg C[11]-PIB. All emission recordings were acquired with the Biograph 6 Hi-Rez (Siemens-CTI, Knoxville, TN) in three-dimensional acquisition mode. Transmission map for attenuation-correction was acquired using the CT emission scans (130 kVp, 240 mA). Standardized uptake values (SUVs) of C[11]-PIB calculated from PET/CT. In normal subjects, 3T MRI T1-weighted images were obtained to create a C[11]-PIB template. Spatial normalization and smoothing were conducted as a pre-processing for PCA using SPM8 and PCA was conducted using Matlab2012b. Results Through the PCA, we obtained linearly uncorrelated independent principal component images. Principal component images obtained through the PCA can simplify the variation of whole C[11]-PIB images into several principal components including the variation of neocortex and white matter and the variation of deep brain structure such as pons. Conclusion PCA is useful to analyze and extract the main pattern of C[11]-PIB image. PCA, as a method of multivariate analysis, might be useful for pattern recognition of neuroimages such as FDG-PET or fMRI as well as C[11]-PIB image.

  • PDF

Clinical Value of Real Time Elastography in Patients with Unexplained Cervical Lymphadenopathy: Quantitative Evaluation

  • Fu, Ying;Shi, Yun-Fei;Yan, Kun;Wang, Yan-Jie;Yang, Wei;Feng, Guo-Shuang
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.13
    • /
    • pp.5487-5492
    • /
    • 2014
  • Ultrasonography is non-invasive and can give useful clues in the diagnosis of cervical lymphadenopathy, However, differential diagnosis is difficult in some situations even combined with color Doppler imaging. The present study was conducted to evaluate the clinical value of real time elastography in patients with unexplained cervical lymphadenopathy using a quantitative method. From May 2011 to February 2012, 39 enlarged lymph nodes from 39 patients with unexplained cervical lymphadenopathy were assessed. All the patients were examined by both B-mode ultrasound, color Doppler flow imaging and elastography. The method of analyzing elasto-graphic data was the calculation of the 10 parametres ("mean", "sd", "area%", "com", "kur", "ske", "con", "ent", "idm", "asm") offered by the software integrated into the Hitachi system. The findings were then correlated with the definitive tissue diagnosis obtained by lymph node dissection or biopsy. Final histology revealed 10 cases of metastatic lymph nodes, 11 cases of lymphoma, 12 cases of tuberculosis and 6 cases of nonspecific lymphadenitis. The significant distinguishing features for conventional ultrasound were the maximum short diameter (p=0.007) and absent of echogenic hilum (p=0.0293). The diagnostic accuracy was 43.6% (17/39 cases) and there were 17 patients with equivocal diagnosis. For elastography, "mean" (p=0.003), "area%" (p=0.009), "kurt" (p=0.0291), "skew" (p=0.014) and "cont" (p=0.012) demonstrated significant differences between groups. With 9 of the 17 patients with previous equivocal diagnoses (52.9%) definite and correct diagnoses could be obtained. The diagnostic accuracy for conventional ultrasound combined elastography was 69.2% (27/39 cases). There were differences in the diagnostic sensitivity of the two methods (p=0.0224). Ultrasound combined with elastography demonstrated higher rates of conclusive and accurate diagnoses in patients with unexplained cervical lymphadenopathy than conventional ultrasound. The quantitative program showed good correlation with the pathology of different lymph node diseases.

The Development of Iodine-123 with MC-50 Cyclotron (MC-50 싸이클로트론을 이용한 $^{123}I$ 제법 연구)

  • Suh, Yong-Sup;Yang, Seung-Tae;Chun, Kown-Soo;Lee, Jong-Doo;Han, Hyon-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.25 no.2
    • /
    • pp.286-293
    • /
    • 1991
  • $^{123}I$, which is applied for the thyroid and other in vivo kinetic study, has a special role in life sciences. The 159 KeV $\gamma-ray$ from $^{123}I$ is almost ideally appropriate for the current imaging instrumentation. Its decay mode (electron capture) and short half-life (13.3 hr) reduced the burden of radiation dose to the patients, and its chemical property makes it easy to synthesize the labelling compounds. In this experiment, the production of $^{123}I$ via the nuclear reaction $^{124}Te(p,2n)^{123}I$ with 28 MeV protons was sutdied. $TeO_2$ is used as a target material, because it has good physical properties. The target was prepared with $TeO_2$ powder and was molten into a ellipsoidal cavity (a=14 mm, b=10 mm, $270.8mg/cm^2$ thick) of pure platinum. The irradiation was carried out in the external proton beam with incident energies range from 28 MeV to 22 MeV, and current was $30{\mu}A$. The loss of $TeO_2$ target was significantly reduced by using $4\pi-cooling$ system in irradiation. The dry distillation method was adopted for the separation of $^{123}I$ from irradiated target, and when it was kept 5 minutes at $780^{\circ}C$, its result was quantitative. The loss of the target material $(TeO_2)$ was below 0.2% for each production run and $^{123}I$ from the dry distillation apparatus was captured with 0.01 N NaOH in $Na^{123}I$ form, then the pH of the solution was adjusted to $7.5\sim9.0$ with HC1/NaOH. The $Na^{123}I$ solution was passed through $0.2{\mu}m$ membrane filter, and sterilized under high pressure and temperature for 30 minutes. The production of $^{123}I$ is acceptable for clinical application based on the quality of USP XXI.

  • PDF

Effect of a Deep Learning Framework-Based Computer-Aided Diagnosis System on the Diagnostic Performance of Radiologists in Differentiating between Malignant and Benign Masses on Breast Ultrasonography

  • Ji Soo Choi;Boo-Kyung Han;Eun Sook Ko;Jung Min Bae;Eun Young Ko;So Hee Song;Mi-ri Kwon;Jung Hee Shin;Soo Yeon Hahn
    • Korean Journal of Radiology
    • /
    • v.20 no.5
    • /
    • pp.749-758
    • /
    • 2019
  • Objective: To investigate whether a computer-aided diagnosis (CAD) system based on a deep learning framework (deep learning-based CAD) improves the diagnostic performance of radiologists in differentiating between malignant and benign masses on breast ultrasound (US). Materials and Methods: B-mode US images were prospectively obtained for 253 breast masses (173 benign, 80 malignant) in 226 consecutive patients. Breast mass US findings were retrospectively analyzed by deep learning-based CAD and four radiologists. In predicting malignancy, the CAD results were dichotomized (possibly benign vs. possibly malignant). The radiologists independently assessed Breast Imaging Reporting and Data System final assessments for two datasets (US images alone or with CAD). For each dataset, the radiologists' final assessments were classified as positive (category 4a or higher) and negative (category 3 or lower). The diagnostic performances of the radiologists for the two datasets (US alone vs. US with CAD) were compared Results: When the CAD results were added to the US images, the radiologists showed significant improvement in specificity (range of all radiologists for US alone vs. US with CAD: 72.8-92.5% vs. 82.1-93.1%; p < 0.001), accuracy (77.9-88.9% vs. 86.2-90.9%; p = 0.038), and positive predictive value (PPV) (60.2-83.3% vs. 70.4-85.2%; p = 0.001). However, there were no significant changes in sensitivity (81.3-88.8% vs. 86.3-95.0%; p = 0.120) and negative predictive value (91.4-93.5% vs. 92.9-97.3%; p = 0.259). Conclusion: Deep learning-based CAD could improve radiologists' diagnostic performance by increasing their specificity, accuracy, and PPV in differentiating between malignant and benign masses on breast US.

Computer Assisted EPID Analysis of Breast Intrafractional and Interfractional Positioning Error (유방암 방사선치료에 있어 치료도중 및 분할치료 간 위치오차에 대한 전자포탈영상의 컴퓨터를 이용한 자동 분석)

  • Sohn Jason W.;Mansur David B.;Monroe James I.;Drzymala Robert E.;Jin Ho-Sang;Suh Tae-Suk;Dempsey James F.;Klein Eric E.
    • Progress in Medical Physics
    • /
    • v.17 no.1
    • /
    • pp.24-31
    • /
    • 2006
  • Automated analysis software was developed to measure the magnitude of the intrafractional and interfractional errors during breast radiation treatments. Error analysis results are important for determining suitable planning target volumes (PTV) prior to Implementing breast-conserving 3-D conformal radiation treatment (CRT). The electrical portal imaging device (EPID) used for this study was a Portal Vision LC250 liquid-filled ionization detector (fast frame-averaging mode, 1.4 frames per second, 256X256 pixels). Twelve patients were imaged for a minimum of 7 treatment days. During each treatment day, an average of 8 to 9 images per field were acquired (dose rate of 400 MU/minute). We developed automated image analysis software to quantitatively analyze 2,931 images (encompassing 720 measurements). Standard deviations ($\sigma$) of intrafractional (breathing motion) and intefractional (setup uncertainty) errors were calculated. The PTV margin to include the clinical target volume (CTV) with 95% confidence level was calculated as $2\;(1.96\;{\sigma})$. To compensate for intra-fractional error (mainly due to breathing motion) the required PTV margin ranged from 2 mm to 4 mm. However, PTV margins compensating for intefractional error ranged from 7 mm to 31 mm. The total average error observed for 12 patients was 17 mm. The intefractional setup error ranged from 2 to 15 times larger than intrafractional errors associated with breathing motion. Prior to 3-D conformal radiation treatment or IMRT breast treatment, the magnitude of setup errors must be measured and properly incorporated into the PTV. To reduce large PTVs for breast IMRT or 3-D CRT, an image-guided system would be extremely valuable, if not required. EPID systems should incorporate automated analysis software as described in this report to process and take advantage of the large numbers of EPID images available for error analysis which will help Individual clinics arrive at an appropriate PTV for their practice. Such systems can also provide valuable patient monitoring information with minimal effort.

  • PDF

Evaluating Quadriceps Muscle Damage after Downhill Running of Different Intensities using Ultrasonography (내리막 달리기 후 국소 근손상의 영상학적 비교분석 : 운동 강도의 영향)

  • Sun, Min Ghyu;Kim, Choun Sub;Kim, Maeng Kyu
    • Journal of the Korean Applied Science and Technology
    • /
    • v.36 no.3
    • /
    • pp.1028-1040
    • /
    • 2019
  • The current study was performed to investigate the magnitude of exercise-induced muscle damage (EIMD) after downhill running (DR) of different intensities and to examine the availability of muscle echo intensity as biomarkers to detect regional damage within quadriceps muscle group (QG) following DR. Healthy college-age men (n=11) were experienced twice DR sessions [$50%HR_{max}$ DR, LDR; $70%HR_{max}$ DR, HDR] separated by a 2-week wash-out period with the random order. After DR, severity of EIMD according to exercise intensity were determined by serum creatine kinase (CK) activity, muscle tenderness, and neuromuscular function indicators such as a maximal voluntary isometric contraction (MVIC) and range of motion (ROM). Transvaginal B-mode imaging had been employed to evaluate regional muscle echo intensity within QG [rectus femoris, RF; vastus lateralis, VL; vastus medialis, VM; vastus intermedius, VI]. After both DR sessions, changes in serum CK activity and muscle tenderness have tended to more increase in HDR compared to those of LDR. There was a significant interaction effect between exercise intensity during DR and the time course of serum CK activity(p<.05). However, there were no statistical differences between sessions in muscle tenderness. The time course of changes in the neuromuscular functions after DR were similar to those of regional muscle echo intensity regardless exercise intensity. Although neuromuscular function showed to decline in HDR more than those of LDR after DR, no statistical differences between sessions. In contrast, there were significant interaction effects between sessions and time course of changes in RF and VL muscle echo intensity(p<.01), but not shown in those of VI and VM. These results indicated that each muscles within the QG show different response profiles for EIMD during DR, exercise intensity influences on these responses as well. In particular, current findings suggested that muscle echo intensity derived from ultrasound imaging is capable of detecting regional muscle damage in QG following DR.