• Title/Summary/Keyword: B-Value

Search Result 8,720, Processing Time 0.041 seconds

A study on the amylase in serum and urine in open heart surgery under the extracorporeal circulation (체외순환 개심술 환자의 혈청 및 뇨중 Amylase 변동에 관한 연구)

  • Lee, Byeong-U;Kim, Geun-Ho
    • Journal of Chest Surgery
    • /
    • v.16 no.1
    • /
    • pp.83-90
    • /
    • 1983
  • During the period of March 1981 to September 1982 a series of survey has been done on the value of amylase in blood and urine of 24 patients who went through the operation of heart surgery, for congenital and acquired heart diseases, with extracorporeal circulation at the Department of Thoracic _ Cardiovascular Surgery, School of Medicine, Hanyang University. In order to analyze the iteration and inter-relation of the value of amylase in blood and urine and the extra corporeal circulation time. The duration of extra-corporeal circulation time up to 60 minutes was classified as Group A while above 60 minutes was classified as Group B. The results are as follow; 1. 3 patients [23.07%] among 13 patients of Group A and 3 patients [27.27%] among 11 patients, showed increased amylase value after the surgery. 2. The average value in blood after operation was 120.3190.71 unit in Group A and 130.90113.15 unit in Group B. It was 11.59 units [9.63%] higher in Group A than in Group B. 3. 1 patient [7.7%] among 13 patients of Group A and 2 patients[18.18%] among 11 patients of Group B, the frequency of Group B was 10.48% higher. 4. The average Value of amylase in urine after the surgery was 111.9254.87 unit in Group A and 151.54111.17 unit in Group B. It was 39.62 unit [32.72%] higher in Group A than in Group B. 5. The longer the duration of extra corporeal circulation time showed the higher the amylase value in blood and urine after the operation. 6. Although the value of amylase in blood and urine was increased after operation, no patients Were found to have developed clinical pancreatitis.

  • PDF

Usefulness of the High B-value DWI in Brain Tumors (뇌종양 확산강조영상에서 High B-value의 유용성 평가)

  • Kim, Jin-tae;Byun, Jae-Hu;Park, Yong-Seong;Lee, Rae-Gon;Hwang, Seon-Kwang
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.17 no.1
    • /
    • pp.33-41
    • /
    • 2015
  • This study attempts to examine the clinical usefulness of High b-value DWI (diffusion weighted imaging) for brain tumors with an edema. Subjects were seven patients selected from 65 patients who received an MRI scan for suspected encephalopathy and confirmed diagnosis at our hospital from February to July 2015 (male: 7, average age : 66 years old). As test equipment, 3.0T MR System (ACHIEVA Release, Philips, Best, The Netherlands) and 8Channel SENSE Head Coill were used. DWI checks on the use of the variable TR 5460ms, TE 132ms, Slice Thickness 4mm, gap 1mm, Slice number 29 is, 3D T1WI is TR 8.4ms, TE 3.9ms, matrix size $240{\times}240$, Slice can set 180 piecesIt was. b value of 0, 1,000, 2,000 s/mm2 with DWI acquisition and 3D T1WI enhancement five minutes after the Slice Thickness 3mm, gap 0mm to reconstruct the upper face axis (MPR TRA CE) was. As for the experiment, in b-value 1,000 and 2,000 images, SNR and the lesion at the lesion site and CNR in the normal site opposite to the lesion are measured. WW(window width) and WL(window level) are made equal in MRICro software, and the volume of the lesion is measured from each of b-value and MPR TRA CE image. Using SPSS ver. 1.8.0.0 Mann Whitney-test was analyzed for SNR and CNR, while Kruskal-Wallis test was analyzed for volume.

  • PDF

A Study on Some Antioxidative Effects of Stewed Pumpkin Juice on Lipid (호박즙의 유지에 대한 항산화 효과)

  • 오봉윤;박복희
    • Korean Journal of Human Ecology
    • /
    • v.1 no.2
    • /
    • pp.89-99
    • /
    • 1998
  • This study was carried out to investigate some antioxidative effects of stewed pumpkin juice (SPJ) and the SPJs added with ginger (SPJ-G), onion (SPJ-O), jujube (SPJ-J) or boxthorn (SPJ-B), respectively, on the lipid oxidation of soybean oil (S) and mackerel pike boiled ground (MPBG). Antioxidative substances of SPJ were extracted by using the two solvent layers of n-hexane:acetone (1:1)(H) and methanol:water (7:3)M. The antioxidative effects of the extracts were observed by the peroxide value (P.O.V.) and thiobabituric acid (T.B.A.) value. The P.O.V. and T.B.A. value of two solvent extracts of S and MPBG showed significantly lower than those of S and MPBG. The SPJ showed very distingnished antioxidative effects. It was considered that melanoidine extracted by using methanol:water (7:3) solvent as well as carotenoid extracted by using n-hexane:acetone (1:1) solvent had an antioxidative effect. During storage, T.B.A. value of MPBG significantly increased, while that of MPBG-SPJ significantly decreased more than that of MPBG. T.B.A. value of MPBG-SPJs decreased much than that of MPBG-SPJ, SPJ-O, SPJ-G, SPJ-J and SPJ-B, in order of abundance, showed higher level of antioxidative effects than SPJ. (Korean J Human Ecology 1(2):89∼99, 1998)

  • PDF

Comparison of Heat Resistance of Bacillus subtilis, Geobacillus stearothermophilus, and Bacillus atrophaeus spores (Bacillus subtilis, Geobacillus stearothermophilus 및 Bacillus atrophaeus 포자의 열 저항성 비교)

  • Eun-Sun Jeong;Ju-Hee Nam;Jung-Beom Kim
    • Journal of Food Hygiene and Safety
    • /
    • v.38 no.5
    • /
    • pp.356-360
    • /
    • 2023
  • We analyzed the heat resistance of non-pathogenic Bacillus atrophaeus, Bacillus subtilis, and Geobacillus stearothermophilus spores which exhibit strong heat resistance and evaluated the possibility of using them to determine direct sterilization when manufacturing retort foods. The D121-values of B. subtilis, G. stearothermophilus, and B. atrophaeus spores were 2.9±0.1 min, 4.3±0.1 min, and 3.7±0.1 min, respectively. The Z-values of B. subtilis, G. stearothermophilus, and B. atrophaeus spores were 43.0±1.4℃, 25.0±1.6℃, and 35.8±1.4℃, respectively. The D121-values of B. subtilis, G. stearothermophilus, and B. atrophaeus spores were all higher than that of Clostridium botulinum spores used to confirm retort food sterilization. Considering these results, B. subtilis, G. stearothermophilus, and B. atrophaeus spores can be used instead of the pathogenic spore-forming bacteria C. botulinum when sterilizing retort food. In addition, sterilization can be confirmed in 2 to 3 days, a shorter time than the 13 days required for existing bacterial growth experiments based on the Korean food code.

The Impact of Customer Value on Relationship Continuity -Focusing on transaction value, relationship value, appraisal value- (기업 간 거래에서 고객가치가 거래지속성에 미치는 영향 -거래가치, 관계 가치, 평가적 가치를 중심으로-)

  • Kim, Hyang-Mi;Lee, So-Young
    • Journal of Digital Convergence
    • /
    • v.14 no.9
    • /
    • pp.123-132
    • /
    • 2016
  • This study starts from the research question that "Why some companies decide to keep working in partnership even when they are not satisfied with the partner companies simply because they are old business partners." The authors try to find the answer in terms of customer value considering the phases of B2B transaction spectrum: transaction value, relationship value and appraisal value implementing empirical research. The result shows that the intension to retain the relation with an existing partner is formed by the trade-off between the benefit and cost of both contract value and relationship value and not the sole value was dominant. The unique point of the study is that current study is considering these two factors as dependent variables which affect the relationship continuity which is not the case in existing researches.

Color lens CIE L*a*b* coordination transfer by tinted time (착색시간에 따른 칼라렌즈 색좌표 이동)

  • Jeong, Byung-Mann;Park, Kwang-Ho;Kim, Yong-Geun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.1
    • /
    • pp.53-57
    • /
    • 2003
  • R, G, Y, B color lenses Manufactured increasing tinted time by 5 min term. CIE $L^*a^*b^*$ coordination's analysis used spectrophotometer and CIE $L^*a^*b^*$ color system. CIE $L^*a^*b^*$ coordination transfer form about tinted time being $$b^*(Y-B)={\beta}a^*+{\alpha}$$ change to do linear almost. In red case, move in $G{\rightarrow}R$, $B{\rightarrow}Y$ form tinted time increases, and Parameter ${\alpha}$, ${\beta}$ value got each -3.49 and 0.90. In green case, CIE $L^*a^*b^*$ coordination transfer form is $R{\rightarrow}G$, $B{\rightarrow}Y$ form. Got the pure green color color in 10 min's tinted time. Parameter ${\alpha}$, ${\beta}$ value got each -0.72 and -0.55. Get into pure yellow and blue color case tinted time increases. Parameter ${\alpha}$, ${\beta}$ value are 14.11 and 1.58 in yellow, and Parameter ${\alpha}$, ${\beta}$ value are -11.62 and 1.30 in blue color.

  • PDF

The complexion of Korean female changed by 7 years. (안색(顔色)에 대한 현대적 조명 : 상고천진론(上古天眞論)의 여자칠세(女子七歲)이론을 근거로)

  • Kim, Eun-Joo;Roh, Ho-Sik;Kim, Duck-Hee;Kim, Hank-On;Cho, Ga-Young
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.23 no.1
    • /
    • pp.253-259
    • /
    • 2010
  • Objectives: We investigated $L^*a^*b^*$ and $ITA^{\circ}$ value on the face to correlate the complexion of Korean female with aging theory of Neijing(內經) in Suwen-Shanggutianzhenlun(素問,上古天眞論). Methods: Three hundreds and thirty one Korean females, aged 22-64 years($39.36{\pm}9.71$ years) were participated in this study. We measured the skin properties of the face with Spectrophotometer CM2600d(Minolta, Japan). Trisimulus $L^*a^*b^*$ color and $ITA^{\circ}$ value divided on 7 years were and analyzed by regression analysis method. Results: $L^*$, ITA value decreased and $a^*$, $b^*$ increased as the age increases. Among these, we found out that ITA value is most related to aging. $L^*$ value decreased among the group of 28 to 35 years old. ITA value decreased among the group of 35 to 42 years old. $a^*$ value decreased among the group of 42 to 49 years old. Conclusions: Unique aging pattern by 7 years of female in Oriental medicine is reflected to complexion.

The Understanding of Determination of Horizontal Centration Point of Single-vision Reading Glasses (단초점 근용 안경의 수평방향 설계점 결정에 대한 이해)

  • Kim, Min Ho;Kim, Hyun-Il
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.2
    • /
    • pp.1-8
    • /
    • 2009
  • Purpose: The purpose of this study is to compare degrees of asthenopia in after wearing of dispensed reading glasses with different criterion of P.D. Methods: The person who has minus near correction power (distance correction value (-)) is compared to the degree of asthenopia by wearing of dispensed reading glasses with near P.D(-B) and distance P.D. The person who has plus near correction power is compared to degree of asthenopia by wearing of dispensed reading glasses with near P.D-B, distance P.D, near P.D-A. The "Near-P.D-A" means reduced optical centre distance of reading glasses of positive correction value at which the same effect of prism B.O through near visual point in distance glasses exist at near visual point in reading glasses. Results: When near correction value is (-), dispensed reading glasses with distance P.D have caused less asthenopia than dispensed glasses with near P.D-B. When the near correction value is (+), we cannot confirm that which P.D is more useful for reading glasses. As a result of this study, dispensed reading glasses with near P.D-A have caused less asthenopia than another criterion of P.D. Conclusion: The effect of prism B.I through a near visual point in distance glasses ((-) correction value) reduce convergence demand. Therefore (-) correction value-reading glasses support convergence in near vision, because the effect of prism B.I of reading glasses is smaller than that of distance glasses. When the near correction value is (+), centration points can be determined by one of near P.D-A, near P.D-B, distance P.D.

  • PDF

Prognostic Value of a CYP2B6 Gene Polymorphism in Patients with Acute Myeloid Leukemia

  • Alazhary, Nevin M;Shafik, Roxan E;Shafik, Hanan E;Kamel, Mahmoud M
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.11
    • /
    • pp.4583-4587
    • /
    • 2015
  • Background: The objectives of this study aimed to detect a CYP2B6 polymorphism in de novo cases of acute myeloid leukemia patients and identify any role in disease progression and outcome. Materials and Methods: DNA was isolated from peripheral blood of 82 newly diagnosed acute myeloid leukemia cases and the CYP2B6 G15631T gene polymorphism was assayed by PCR restriction fragment length polymorphism (PCR-RFLP). Results: The frequency of the GG genotype (wild type) was 48 (58.5%) and that of the mutant type T allele was 34 (41.9%). GT genotype heterozygous variants were found in 28 (34%), and TT genotype homozygous variants in 6 (7.3%) cases. We found no significant association between the CYP2B6 G15631T polymorphism and complete response (CR) (p-value=0.768), FAB classification (p-value=0.51), cytogenetic analysis (p-value=0.673), and overall survival (p-value=0.325). Also, there were no significant links with early toxic death (p-value=0.92) or progression-free survival (PFS) (p-value=0.245). Conclusions: Our results suggest that the CYP2B6 polymorphism has no role in disease progression, therapeutic outcome, patient free survival, early toxic death and overall survival in acute myeloid leukemia patients.

Development of B-Value Based GBAS Ground Facility Error Standard Deviation Model and Verification (B-Value를 이용한 GBAS 지상국 오차 표준편차 모델 개발 및 성능 평가)

  • Jun, Hyang-Sig;Ahn, Jong-Sun;Lee, Young-Jae;Choi, Young-Kiu;Sung, Sang-Kyung;Yeom, Chan-Hong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.12
    • /
    • pp.1232-1237
    • /
    • 2009
  • The ICAO and FAA are developing and verifying of GBAS for civil aircraft landing and take-off. The guarantee of aircraft integrity issue is the important part of GBAS. To guarantee integrity, the GBAS ground facility broadcasts various informations to aircraft. The informations are related to the estimated accuracy of each pseudorange correction and the estimated error terms, for example B-value and standard deviation of the ground facility error. These parameters are used to calculate position error (estimated value of the user). If estimated position errors don't satisfy requirements, aircraft use alternate navigation means. In this paper, GBAS reference stations's real data, which operated by KARI (Korea Aerospace Research Institute) in Jeju international airport, are used to development of new ground facility error standard deviation model. We verify improvement of GBAS availability, with respected to vertical protection level, using B-value based a new ground facility error standard deviation model and a sigma inflation factor.