• Title/Summary/Keyword: B/F ratio

Search Result 652, Processing Time 0.029 seconds

A Study on the Prediction of Fatigue Life in 2024-T3 Aluminium using X-ray Half-Value Breadth (X선 반가폭을 이용한 Al 2024-T3 합금의 피로수명예측에 관한 연구)

  • 조석수;김순호;주원식
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.1
    • /
    • pp.145-152
    • /
    • 2000
  • X-ray diffraction method detects change of crystal lattice distance under material surface using diffraction angle 2$\theta$. This technique can be applied to the behavior on slip band and micro crack due to material degradation. The relation between half-value breadth and number of cycle has three stages which constitute rapid decrease in initial number of cycles, slight decrease in middle number of cycles and rapid decrease in final number of cycles. The ratio of half-value breadth takes a constant value on B/B$_{0}$-N diagram with loading condition except early part of fatigue life. The ratio of half-value breadth B/B$_{0}$ with respect to number of cycle to failure N$_{f}$ has linear behavior on B/B$_{0}$-log N$_{f}$ diagram. Therefore, in this paper the estimation of fatigue life by average gradient method has much less estimated mean error than the estimation of fatigue life by log B/B$_{0}$-log N/N$_{f}$ relation.elation.ation.

  • PDF

Document Classification of Small Size Documents Using Extended Relief-F Algorithm (확장된 Relief-F 알고리즘을 이용한 소규모 크기 문서의 자동분류)

  • Park, Heum
    • The KIPS Transactions:PartB
    • /
    • v.16B no.3
    • /
    • pp.233-238
    • /
    • 2009
  • This paper presents an approach to the classifications of small size document using the instance-based feature filtering Relief-F algorithm. In the document classifications, we have not always good classification performances of small size document included a few features. Because total number of feature in the document set is large, but feature count of each document is very small relatively, so the similarities between documents are very low when we use general assessment of similarity and classifiers. Specially, in the cases of the classification of web document in the directory service and the classification of the sectors that cannot connect with the original file after recovery hard-disk, we have not good classification performances. Thus, we propose the Extended Relief-F(ERelief-F) algorithm using instance-based feature filtering algorithm Relief-F to solve problems of Relief-F as preprocess of classification. For the performance comparison, we tested information gain, odds ratio and Relief-F for feature filtering and getting those feature values, and used kNN and SVM classifiers. In the experimental results, the Extended Relief-F(ERelief-F) algorithm, compared with the others, performed best for all of the datasets and reduced many irrelevant features from document sets.

ON THE CATCH OF GILL NET IN THE JEJU ISLAND -Comparison of mackerel catch in monofilament and multifilament gill nets- (제주도 자망이망율에 관하여 -고등어 자망의 이망율 비교-)

  • SHON Tae Jun
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.8 no.1
    • /
    • pp.7-10
    • /
    • 1975
  • The catches of mackerel by monofilament and multifilament net were compared by means of $x^2$ and t-test method. In order to improve the netting twine of drift nets, 6 shoots 5 different mesh and nylon-monofilament netting twines $(B\times2,\;C\;D,\;F,)$ and 2 shoe nylon-multifilament $(A\times2)$ which are using near the Jeju Island in contemporary days were used for the experiment. These gill no were connected in order of A, ,B, C, A, B, E, F and operated fly fishing boat Taeann Ho (7T) near sea of Jeju Ialand from May 1974 to August 1974. The results obtained are as follows: 1. B type nylon-monofilament gill nets were superior to nylon-multifilament gill nets in catch according to the result of $X^2$ test and t-test, and the catch ratio was $M_A:\;M_B=1:1.8$. 2. 75mm mesh size C, D nylon-monofilament gill nets were superior to 85mm mesh size nylonmonofilament gill nets, and their catch ratio were E, F: C, D=1:2.8. 3. The catch ratio C, D and E, F type nets were compared by means of t-teat, however could not recognized their relationship.

  • PDF

The Effects of Perilla and Pine Nut on Blood Components in Rats (들깨와 잣이 흰쥐의 혈액 성분에 미치는 영향)

  • Jho, Hu Jhong
    • Journal of Environmental Health Sciences
    • /
    • v.10 no.1
    • /
    • pp.99-106
    • /
    • 1984
  • The diets used to this experiment were composed only of stock diet for group A, a mixture of stock diet and 2% cholesterol for group B, and 5%, 10% perilia powder for group C, D and 5%, 10% pine nut for group E, F in addition to group B diet respectively. All groups fed with these experimental diets for 3 weeks were fasted for 15 hours at the end of the experiment, and then they were decapitated to take serum. The serum was used to measure the level of glucose, total cholesterol, triglyceride, HDL-cholesterol and lipoprotein composition. The results were summarized as follows. 1. Perilla and pine nut diets have no influence on body weight and food intake in cholesterolfed male rats 2. The blood glucose level was not changed significantly at groups C-F. 3. Total cholesterol level was significantly decreased by 21.6% ~ 29.7% at group C-F than at group B. 4. HDL-cholesterol level was increased by 51.3% ~ 86.1% at group C-F than at Group B. 5. The $\alpha/\beta$ ratio which is 0.51 at the group A was risen to 0.99 at the group B. However, this ratio was decreased to 0.5 0 - 0.51 at group C, D and to 0.68 - 0.69 at group E.F.

  • PDF

Electrical Properties and Temperature Stability of resonant Frequency with Zr/Ti ratio in PSN-PMN-PZT Ceramics (PSN-PMN-PZT 세라믹스의 Zr/Ti 비에 따른 전기적 특성과 공진주파수의 온도안정성)

  • 류주현;윤광희;민석규;이명수;서성재
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.8
    • /
    • pp.675-680
    • /
    • 2000
  • In this study the temperature coefficient of resonant frequency(TC $F_{r}$) dielectric and piezoelectric properties of Pb[(S $b_{1}$2//N $b_{1}$2/)$_{0.065}$)-(Z $r_{x}$, $Ti_{1-x}$ )$_{0.90}$] $O_3$ceramics were investigated with Zr/Ti ratio. The compositions near the morphotropic phase boundary (MPB) appeared when Zr/Ti ratio was 49.5/50.5 The dielectric constant and electromechanical coupling factor( $k_{p}$) also showed the highest values of 1,257, 0.653 respectively when the Zr/Ti ratio was 49.5/50.5 Moreover the mechanical quality factor( $Q_{m}$) showed th lowest value of 713 when the Zr/Ti ratio. The temperature coefficient of resonant frequency(TC $F_{r}$) abruptly change at the morphotropic phase boundary(MPB) which existed between the rhombohedral phase with highly negative TC $F_{r}$ of -106ppm/$^{\circ}C$ and the tetragonal phase with highly positive TC $F_{r}$ of +64pp $m^{\circ}C$ as Zr/Ti ratio varied from 50/50 to 49.5/50.5.50.5..50.5.

  • PDF

High Performance Millimeter-Wave Image Reject Low-Noise Amplifier Using Inter-stage Tunable Resonators

  • Kim, Jihoon;Kwon, Youngwoo
    • ETRI Journal
    • /
    • v.36 no.3
    • /
    • pp.510-513
    • /
    • 2014
  • A Q-band pHEMT image-rejection low-noise amplifier (IR-LNA) is presented using inter-stage tunable resonators. The inter-stage L-C resonators can maximize an image rejection by functioning as inter-stage matching circuits at an operating frequency ($F_{OP}$) and short circuits at an image frequency ($F_{IM}$). In addition, it also brings more wideband image rejection than conventional notch filters. Moreover, tunable varactors in L-C resonators not only compensate for the mismatch of an image frequency induced by the process variation or model error but can also change the image frequency according to a required RF frequency. The implemented pHEMT IR-LNA shows 54.3 dB maximum image rejection ratio (IRR). By changing the varactor bias, the image frequency shifts from 27 GHz to 37 GHz with over 40 dB IRR, a 19.1 dB to 17.6 dB peak gain, and 3.2 dB to 4.3 dB noise figure. To the best of the authors' knowledge, it shows the highest IRR and $F_{IM}/F_{OP}$ of the reported millimeter/quasi-millimeter wave IR-LNAs.

농흉에 대한 임상적 고찰

  • 정수상
    • Journal of Chest Surgery
    • /
    • v.13 no.1
    • /
    • pp.26-33
    • /
    • 1980
  • The incidence of the empyema thoracis has been drastically reduced with the advent of antimicrobial drugs. Empyema thoracis is however still dealt with one of major problems in thoracic surgery because of difficulties in the management of associated bronchopleural fistula. During the period of January 1975 to June 1979, 145 patients of empyema thoracis were treated in the Department of Thoracic Surgery, Busan National University Hospital. This reports dealed especially with the incidence, etiology and management of chronic empyema thoracis with B.P.F. and estimated the results of intercostal myoplasty. The results: 1 ] Among 145 empyema thoracis patients, 33 patients [22.7%] had bronchopleural fistula. 2] Male predominated in general with the ratio of 4:1 and in empyema thoracis with B.P.F. male predominance was further more prominent with the ratio of 10:1. Peak incidence of chronic empyema thoracis lay on 3rd and 4th decade. 3] The most common causation of empyema thoracis was pneumonia [77.3%] in children and tuberculosis [48.8%] in adult. 4] The most common causative organism of empyema thoracis was staphylococcus aureus [52.5%]. 5] Among 40 cases of resection for pulmonary tuberculosis, 4 cases developed empyema thoracis with B.P.F. [10%], and resection for another underlying pathology was 2.1%. 6] In contrast to good prognosis of acute empyema thoracis, chronic empyema thoracis with B.P.F. was improved only 66.6% of cases. 81.5% of chronic empyema without B.P.F. were cured completely. 7] Intercostal myoplasty were performed in 21 cases of empyema thoracis with B.P.F. and of which 15 cases showed that fistula were closed. 8] The over all mortality rate in empyema thoracis was 8.7%. The mortality rate of chronic empyema thoracis with and without B.P.F. was 15.2% and 5.3% respectively.

  • PDF

Development of Standard Capacitors with Serial/Parallel Connection Structure for Expanding National Standard Traceability of Capacitance Standard Field (전기용량 국가표준 소급범위 확장을 위한 직/병렬 연결구조의 전기용량 표준기 개발)

  • Kim Han-Jun;Kang Jeon-Hong;Han Sang-Ok
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.8
    • /
    • pp.403-407
    • /
    • 2006
  • Standard capacitors, as like as Hamon resistor standards, of series connection/parallel connection ratio $10{\mu}F/1000{\mu}F\;and\;100{\mu}F/10000{\mu}F$ were fabricated for calibration of impedance bridges or analyzers with measuring ranges up to 1 F. The calculated correction terms to the ratio of one measured value in series connection to the value in parallel connection were evaluated to be $1.92{\times}10^{-7}$. These capacitors were designed to be used not only as 100:1 capacitance standards but also as single capacitors or decade capacitors with decade values at frequencies up to 1 kHz.

Optimum Lactose: Sucrose Ratio for the Pigs Weaned at 21 Days of Age

  • Jin, C.F.;Kim, J.H.;Han, In K.;Yeon, J.U.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.11 no.2
    • /
    • pp.185-191
    • /
    • 1998
  • A total of 240 weaned pigs (BW 5.4 kg) were allotted in a completely randomized block design to find out the optimum lactose : sucrose ratio for the weaned pigs. Treatments were 100:0 (A), 75:25 (B), 50:50 (C), 25:75 (D) and 0:100 (E) in lactose : sucrose ratio. For the first week after weaning, average daily gain (ADG) and feed/gain (F/G) were improved (p < 0.05) for pigs fed A, B and C diets compared to pigs fed diets D and E, but the average daily feed intakes (ADFI) of the pigs were not different. From d 7 to 14, no significant differences was found in ADG and ADFI among the treatments, but pigs fed the diets A, B and C had improved F/G compared with the pigs fed diets D and E (p < 0.05). From d 15 to 21, no significant differences were found in ADG, ADFI and F/G among the treatments. The digestibility of nutrients was not influenced by the lactose : sucrose ratio except nitrogen. Nitrogen digestibility of A diet was significantly higher than D and E diets (p < 0.05) but no significant differences were found among diets A, B and C. Dry matter and phosphorus excretions were not influenced by the treatments. The pigs fed diets A, B and C excreted significantly less nitrogen than the pigs fed diets D and E. In conclusion, the results suggest that sucrose can effectively replace up to 50% lactose in starter diets.

The Deformation and Breaking Load of the Fishing Hook by the Tensile Test (인장시험에 의한 낚시의 변형과 파단하중)

  • KO Kwan-Soh;KIM Yong-Hae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.14 no.4
    • /
    • pp.269-275
    • /
    • 1981
  • The fishing hooks were tested for breaking and unbending due to plastic deformation of the material. Study of tensile test is not complicated, but has not even worked out fully enough, especially when the test specimen is subjected to plastic deformation. The fishing hook is subjected to unbending stress and the critical section is a Point which is furthest from the line of action of the forces. The dynamic force of fish during jerks depends on their speed of movement and body weight, the kinetic energy corresponding to it and also on the rlastic displacement of the rigging which absorb the energy. Six kinds of hook were tested by the dynamometer under tensile speed 290mm/min (subscript s) and 780mm/min (subscript f). According to their results, the breaking load(B: kg) can be induced with the formula $B={\alpha}wd^2+\beta$ where w(mm) is the distance between the barb base and the lower shank and d(mm) is diameter. The coefficients of the formula for the round hooks(R) and the angular hooks(A) are approximately as follows: $$R:\;\alpha_{s}=0.5,\;\beta_{s}=1.6,\;\alpha_{f}=0.4,\;\beta_{f}=1.4$$ $$A:\;\alpha_{s}=1.1,\;\beta_{s}=2.0,\;\alpha_{f}=1.0,\;\beta_{f}=0.9$$ The ratio of $B_{f}\;to\;B_{s}$ is corresponding to 0.8. The ratio of deformation(X) that is moved distance of barb base at break to the distance(H) between head base and barb base is about $50\%$. Further study should be carried out on the subject of impact and fatigue test under the same condition which is exerted force by the hooked fish.

  • PDF