• Title/Summary/Keyword: Axial tomography

검색결과 206건 처리시간 0.031초

Cone-beam CT analysis of patients with obstructive sleep apnea compared to normal controls

  • Buchanan, Allison;Cohen, Ruben;Looney, Stephen;Kalathingal, Sajitha;De Rossi, Scott
    • Imaging Science in Dentistry
    • /
    • 제46권1호
    • /
    • pp.9-16
    • /
    • 2016
  • Purpose: To evaluate the upper airway dimensions of obstructive sleep apnea (OSA) and control subjects using a cone-beam computed tomography (CBCT) unit commonly applied in clinical practice in order to assess airway dimensions in the same fashion as that routinely employed in a clinical setting. Materials and Methods: This was a retrospective analysis utilizing existing CBCT scans to evaluate the dimensions of the upper airway in OSA and control subjects. The CBCT data of sixteen OSA and sixteen control subjects were compared. The average area, average volume, total volume, and total length of the upper airway were computed. Width and anterior-posterior (AP) measurements were obtained on the smallest axial slice. Results: OSA subjects had a significantly smaller average airway area, average airway volume, total airway volume, and mean airway width. OSA subjects had a significantly larger airway length measurement. The mean A-P distance was not significantly different between groups. Conclusion: OSA subjects have a smaller upper airway compared to controls with the exception of airway length. The lack of a significant difference in the mean A-P distance may indicate that patient position during imaging (upright vs. supine) can affect this measurement. Comparison of this study with a future prospective study design will allow for validation of these results.

Quantitative assessment of image artifacts from root filling materials on CBCT scans made using several exposure parameters

  • Rabelo, Katharina Alves;Cavalcanti, Yuri Wanderley;de Oliveira Pinto, Martina Gerlane;Melo, Saulo Leonardo Sousa;Campos, Paulo Sergio Flores;de Andrade Freitas Oliveira, Luciana Soares;de Melo, Daniela Pita
    • Imaging Science in Dentistry
    • /
    • 제47권3호
    • /
    • pp.189-197
    • /
    • 2017
  • Purpose: To quantify artifacts from different root filling materials in cone-beam computed tomography (CBCT) images acquired using different exposure parameters. Materials and Methods: Fifteen single-rooted teeth were scanned using 8 different exposure protocols with 3 different filling materials and once without filling material as a control group. Artifact quantification was performed by a trained observer who made measurements in the central axial slice of all acquired images in a fixed region of interest using ImageJ. Hyperdense artifacts, hypodense artifacts, and the remaining tooth area were identified, and the percentages of hyperdense and hypodense artifacts, remaining tooth area, and tooth area affected by the artifacts were calculated. Artifacts were analyzed qualitatively by 2 observers using the following scores: absence (0), moderate presence (1), and high presence (2) for hypodense halos, hypodense lines, and hyperdense lines. Two-way ANOVA and the post-hoc Tukey test were used for quantitative and qualitative artifact analysis. The Dunnet test was also used for qualitative analysis. The significance level was set at P<.05. Results: There were no significant interactions among the exposure parameters in the quantitative or qualitative analysis. Significant differences were observed among the studied filling materials in all quantitative analyses. In the qualitative analyses, all materials differed from the control group in terms of hypodense and hyperdense lines (P<.05). Fiberglass posts did not differ statistically from the control group in terms of hypodense halos(P>.05). Conclusion: Different exposure parameters did not affect the objective or subjective observations of artifacts in CBCT images; however, the filling materials used in endodontic restorations did affect both types of assessments.

The Prevalence of Cervical Foraminal Stenosis on Computed Tomography of a Selected Community-Based Korean Population

  • Ko, Sangbong;Choi, Wonkee;Lee, Jaejun
    • Clinics in Orthopedic Surgery
    • /
    • 제10권4호
    • /
    • pp.433-438
    • /
    • 2018
  • Background: Cervical foraminal stenosis (CFS) is one of the degenerative changes of the cervical spine; however, correlations between the severity of stenosis and that of symptoms are not consistent in the literature. Studies to date on the prevalence of stenosis are based on images obtained from the departments treating cervical lesions, and thus patient selection bias may have occurred. The purpose of this study was to investigate the prevalence of CFS according to the site, extent, and morphology of stenosis using cervical computed tomography (CT) images obtained from patients who were visiting not because of symptoms related to the cervical spine, cervical pain, or upper limb pain. Methods: Among patients who underwent CT from January 2016 to March 2016 for reasons other than cervical spine symptoms, a total of 438 subjects were enrolled, and 2,628 cervical disc images (C4-5, C5-6, and C6-7; left and right sides) were examined. Three orthopedic surgeons performed two measurements each at 4-week intervals. Values were used for analysis if matched by more than two surgeons; if no match was found, the median values were used for analysis. The left and right sides on the same axial image were independently classified. Results: Left C5-6 stenosis was most common (24.66%) among patients. At the left C6-7, there were 20 focal types and 33 diffuse types. At bilateral C4-5 and right C6-7, the focal type was more common, whereas at bilateral C5-6 and left C6-7, the diffuse type was more common. Age and the severity of stenosis showed statistically significant correlation at all cervical levels. Conclusions: The prevalence of CFS was highest at the C5-6 level (19.06%). Compared to other levels, focal stenosis was more frequent at C4-5 and diffuse stenosis was more common at C5-6. At C6-7, the incidence of focal stenosis was higher on the right side and that of diffuse stenosis was higher on the left side.

Fused roots of maxillary molars: characterization and prevalence in a Latin American sub-population: a cone beam computed tomography study

  • Marcano-Caldera, Maytte;Mejia-Cardona, Jose Luis;Blanco-Uribe, Maria del Pilar;Chaverra-Mesa, Elena Carolina;Rodriguez-Lezama, Didier;Parra-Sanchez, Jose Hernan
    • Restorative Dentistry and Endodontics
    • /
    • 제44권2호
    • /
    • pp.16.1-16.12
    • /
    • 2019
  • Objectives: The upper molars generally have three roots; therefore, different combinations of fusion can occur, increasing the possibility of finding more complex root canal systems. The purpose of this study was to evaluate the prevalence and characterization of fused roots in first and second maxillary molars using cone-beam computed tomography (CBCT) in a Colombian population. Materials and Methods: A total of 1274 teeth were evaluated, of which 534 were maxillary first molars and 740 were maxillary second molars. Axial sections were made at the cervical, middle, and apical levels to determine the prevalence of root fusion and the types of fusion. Results: Overall, 43% of the molars (n = 551) presented some type of fused root. Root fusion was present in 23.4% of the maxillary first molars. The most frequent type of fused root was type 3 (distobuccal-palatal; DB-P) (58.9%). Root fusion was observed in 57.6% of the maxillary second molars, and the most prevalent type of fused root was type 6 (cone-shaped) (45.2%). Of the maxillary molars, 12.5% were classified as C-shaped. Conclusion: Within the limitations of this study, there was a high prevalence of fused roots in maxillary molars in the Colombian population, mainly in the maxillary second molars. In first molars, the most common type of fused root was type 3 (DB-P) and in second molars, the most common type was type 6 (cone-shaped). Additionally, molars with root fusion presented variation at different levels of the radicular portion, with implications for treatment quality.

Evaluating Paraspinal Back Muscles Using Computed Tomography (CT) and Magnetic Resonance Imaging (MRI): Reliability Analysis and Correlation with Intervertebral Disc Pathology

  • Hwang, Eunjin;Antony, Chermaine Deepa;Choi, Jung-Ah;Kim, Minsu;Khil, Eun Kyoung;Choi, Il
    • Investigative Magnetic Resonance Imaging
    • /
    • 제25권2호
    • /
    • pp.109-117
    • /
    • 2021
  • Purpose: To investigate the reliability of CT and MRI for quantitative and qualitative analyses of lumbar paraspinal muscle fatty infiltration (PSFI) and correlation of PSFI with intervertebral disc pathology. Materials and Methods: Lumbar spine CT and MRI of 36 subjects were reviewed retrospectively. Two observers independently outlined lumbar paraspinal muscles at each mid-intervertebral disc level. Paraspinal muscles on CT and MRI were graded according to the Goutallier grading system (GGS). The area, mean value, and standard deviation (SD) of the Hounsfield unit (HU) were obtained. Intervertebral discs were assessed on axial image of T2WI at each level. Correlations between qualitative and quantitative data and intervertebral disc pathology, age, and sex were evaluated. Results: Inter- and intra-observer agreements for results of GGS on MRI were substantial (κ = 0.79) and moderate (κ = 0.59), respectively. Inter- and intra-observer agreements for results of GGS on CT were almost perfect (κ = 0.88) and substantial (κ = 0.66), respectively. Quantitative measurements of HU showed almost perfect inter- and intra-observer reliabilities (κ = 0.82 and κ = 0.99, respectively). There were statistically significant correlations between intervertebral disc pathology and PSFI at L1-2, L2-3, and L4-5 levels on MRI and at L1-2 and L3-4 levels on CT. Age showed significant correlation with results of GGS at all levels on CT and MRI. Conclusion: This study showed that GGS results and HU measurements could be useful for evaluating PSFI because they showed correlations with intervertebral disc pathology results at certain levels.

Influence of CBCT parameters on image quality and the diagnosis of vertical root fractures in teeth with metallic posts: an ex vivo study

  • Larissa Pereira Lagos de Melo;Polyane Mazucatto Queiroz;Larissa Moreira-Souza;Mariana Rocha Nadaes;Gustavo Machado Santaella;Matheus Lima Oliveira;Deborah Queiroz Freitas
    • Restorative Dentistry and Endodontics
    • /
    • 제48권2호
    • /
    • pp.16.1-16.11
    • /
    • 2023
  • Objectives: The aim of this study was to evaluate the influence of peak kilovoltage (kVp) and a metal artifact reduction (MAR) tool on image quality and the diagnosis of vertical root fracture (VRF) in cone-beam computed tomography (CBCT). Materials and Methods: Twenty single-rooted human teeth filled with an intracanal metal post were divided into 2 groups: control (n = 10) and VRF (n = 10). Each tooth was placed into the socket of a dry mandible, and CBCT scans were acquired using a Picasso Trio varying the kVp (70, 80, 90, or 99), and the use of MAR (with or without). The examinations were assessed by 5 examiners for the diagnosis of VRF using a 5-point scale. A subjective evaluation of the expression of artifacts was done by comparing random axial images of the studied protocols. The results of the diagnoses were analyzed using 2-way analysis of variance and the Tukey post hoc test, the subjective evaluations were compared using the Friedman test, and intra-examiner reproducibility was evaluated using the weighted kappa test (α = 5%). Results: The kVp and MAR did not influence the diagnosis of VRF (p > 0.05). According to the subjective classification, the 99 kVp protocol with MAR demonstrated the least expression of artifacts, while the 70 kVp protocol without MAR led to the most artifacts. Conclusions: Protocols with higher kVp combined with MAR improved the image quality of CBCT examinations. However, those factors did not lead to an improvement in the diagnosis of VRF.

Measurement of S1 foramen depth for ultrasound-guided S1 transforaminal epidural injection

  • Ye Sull Kim;SeongOk Park;Chanhong Lee;Sang-Kyi Lee;A Ram Doo;Ji-Seon Son
    • The Korean Journal of Pain
    • /
    • 제36권1호
    • /
    • pp.98-105
    • /
    • 2023
  • Background: Ultrasound-guided first sacral transforaminal epidural steroid injection (S1 TFESI) is a useful and easily applicable alternative to fluoroscopy or computed tomography (CT) in lumbosacral radiculopathy. When a needle approach is used, poor visualization of the needle tip reduces the accuracy of the procedure, increasing its difficulty. This study aimed to improve ultrasound-guided S1 TFESI by evaluating radiological S1 posterior foramen data obtained using three-dimensional CT (3D-CT). Methods: Axial 3D-CT images of the pelvis were retrospectively analyzed. The radiological measurements obtained from the images included 1st posterior sacral foramen depth (S1D, mm), 1st posterior sacral foramen width (S1W, mm), the angle of the 1st posterior sacral foramen (S1A, °), and 1st posterior sacral foramen distance (S1ds, mm). The relationship between the demographic factors and measured values were then analyzed. Results: A total of 632 patients (287 male and 345 female) were examined. The mean S1D values for males and females were 11.9 ± 1.9 mm and 10.6 ± 1.8 mm, respectively (P < 0.001); the mean S1A 28.2 ± 4.8° and 30.1 ± 4.9°, respectively (P < 0.001); and the mean S1ds, 24.1 ± 2.9 mm and 22.9 ± 2.6 mm, respectively (P < 0.001); however, the mean S1W values were not significantly different. Height was the only significant predictor of S1D (β = 0.318, P = 0.004). Conclusions: Ultrasound-guided S1 TFESI performance and safety may be improved with adjustment of needle insertion depth congruent with the patient's height.

Skeletal and dentoalveolar effects of different types of microimplant-assisted rapid palatal expansion

  • Hyeong-Yoon Choi;Sang-Min Lee;Jin-Woo Lee;Dong-Hwa Chung;Mo-Hyeon Lee
    • 대한치과교정학회지
    • /
    • 제53권4호
    • /
    • pp.241-253
    • /
    • 2023
  • Objective: To evaluate the following null hypothesis: the skeletal and dentoalveolar expansion patterns in the coronal and axial planes are not different with two different types of microimplant-assisted rapid palatal expansion (MARPE) systems. Methods: Pretreatment (T0) and post-MARPE (T1) cone-beam computed tomography (CBCT) images of 32 patients (14 males and 18 females; mean age, 19.37) were analyzed. We compared two different MARPE systems. One MARPE system included the maxillary first premolars, maxillary first molars, and four microimplants as anchors (U46 type, n = 16), while the other included only the maxillary first molars and microimplants as anchors (U6 type, n = 16). Results: In the molar region of the U6 and U46 groups, the transverse expansion at the midnasal, basal, alveolar, and dental levels was 2.64, 3.52, 4.46, and 6.32 mm and 2.17, 2.56, 2.73, and 5.71 mm, respectively. A significant difference was observed in the posterior alveolar-level expansion (p = 0.036) and posterior basal-bone-level expansion (p = 0.043) between the groups, with greater posterior skeletal and alveolar expansion in the U6 group. Conclusions: Compared with the U46 group, the U6 group showed greater posterior expansion at the alveolar and basal-bone levels, with an almost parallel split. Both groups showed a pyramidal expansion pattern in the coronal view.

Morphometric analysis of sacral corridor in the upper three sacral segments to prevent neurovascular injury

  • Binita Chaudhary;Prem Kumar;Ruchika Narayan;Adil Asghar;Padamjeet Panchal;Neelam Kumari
    • Anatomy and Cell Biology
    • /
    • 제57권2호
    • /
    • pp.221-228
    • /
    • 2024
  • Although studies of the sacral corridor dimension have been reported in the European population, little attention has been paid to this issue in the Asian population. The purpose of the study is to estimate the safe dimension of the corridor to avoid neurovascular damage during the fixation of the sacral fracture. The study aimed to examine the cephalocaudal (vertical) and the anteroposterior diameter of the bony passage in the upper three sacral segments. The study further examines the effect of age and sex on corridor dimensions at different sacral levels. Three-dimensionally reconstructed sacra from computed tomography of normal subjects were included in the study. Cephalocaudal and anteroposterior diameters were measured in coronal and axial sections using Geomagic Freeform Plus software. Anteroposterior diameter of the sacral corridor at the first, second, and third sacral segments are significantly higher in males (P=0.013, 0.0011, and <0.0001, respectively). The length of the sacrum also revealed sexual dimorphism (P<0.00016). The anteroposterior diameter of the second sacral segment (ap-S2c) correlated moderately with the first sacral anteroposterior diameter (ap-S1c) (R=0.519, P<0.001). The ap-S2c exhibited a moderate correlation to the third sacral segment (ap-S3c) (R=0.677, P<0.001). The sacral corridor at the level of S1 has the largest cephalocaudal (18.25 mm) and anteroposterior diameter (17.11 mm). Placement of the screw in the first sacral corridor may avoid damage to the neurovascular bundle during the fixation of the sacral fracture.

개인용 컴퓨터와 소프트웨어를 이용한 3차원 전산화단층영상에서의 금속 수복물에 의한 선상 오류의 제거 (The elimination of the linear artifacts by the metal restorations in the three dimensional computed tomographic images using the personal computer and software)

  • 박혁;이희철;김기덕;박창서
    • Imaging Science in Dentistry
    • /
    • 제33권3호
    • /
    • pp.151-159
    • /
    • 2003
  • Purpose: The purpose of this study is to evaluate the effectiveness and usefulness of newly developed personal computer-based software to eliminate the linear artifacts by the metal restorations. Materials and Methods: A 3D CT image was conventionally reconstructed using ADVANTAGE WINDOWS 2.0 3D Analysis software (GE Medical System, Milwaukee, USA) and eliminated the linear artifacts manually. Next, a 3D CT image was reconstructed using V-works 4.0/sup TM/(Cybermed Inc., Seoul, Korea) and the linear artifacts eliminated manually in the axial images by a skillful operator using a personal computer. A 3D CT image was reconstructed using V-works 4.0/sup TM/(Cybermed Inc., Seoul, Korea) and the linear artifacts were removed using a simplified algorithm program to eliminate the linear artifacts automatically in the axial images using a personal computer, abbreviating the manual editing procedure. Finally, the automatically edited reconstructed 3D images were compared to the manually edited images. Results and Conclusion: We effectively eliminated the linear artifacts automatically by this algorithm, not by the manual editing procedures, in some degree. But programs based on more complicated and accurate algorithms may lead to a nearly flawless elimination of these linear artifacts automatically.

  • PDF