• 제목/요약/키워드: Axial load ratio

검색결과 531건 처리시간 0.024초

고장력(SM570)강재의 압축재 특성에 관한 연구 (A Study on the Characteristics of High Tensile Strength Steel(SM570) Plates in Compression Members)

  • 임성우;고상기;장인화
    • 한국강구조학회 논문집
    • /
    • 제13권3호
    • /
    • pp.223-232
    • /
    • 2001
  • 본 연구에서는 높은 축력을 받는 기둥재에 사용 가능성이 큰 고장력 용접구조용 압연강재인 SM570의 압축좌굴내력을 평가하기 위해서 중심압축실험을 실시하였다. 단 주압축 실험결과 강구조 계산규준이 정하고 있는 판폭두께비의 제한치를 만족시키는 기둥부재의 최대내력은 국부좌굴에 의해 결정되며, 판폭두께비의 제한치를 만족시키지는 못하는 경우에는 최대내력이 도달하기 전에 국부좌굴에 의해서 급격히 저하하였다. 또한 압축 좌굴내력이 SM570 강재의 설계기준값인 $4.1tonf/cm^2$보다 높게 나타났다.

  • PDF

Shear strength model for reinforced concrete corbels based on panel response

  • Massone, Leonardo M.;Alvarez, Julio E.
    • Earthquakes and Structures
    • /
    • 제11권4호
    • /
    • pp.723-740
    • /
    • 2016
  • Reinforced concrete corbels are generally used to transfer loads within a structural system, such as buildings, bridges, and facilities in general. They commonly present low aspect ratio, requiring an accurate model for shear strength prediction in order to promote flexural behavior. The model described here, originally developed for walls, was adapted for corbels. The model is based on a reinforced concrete panel, described by constitutive laws for concrete and steel and applied in a fixed direction. Equilibrium in the orthogonal direction to the shearing force allows for the estimation of the shear stress versus strain response. The original model yielded conservative results with important scatter, thus various modifications were implemented in order to improve strength predictions: 1) recalibration of the strut (crack) direction, capturing the absence of transverse reinforcement and axial load in most corbels, 2) inclusion of main (boundary) reinforcement in the equilibrium equation, capturing its participation in the mechanism, and 3) decrease in aspect ratio by considering the width of the loading plate in the formulation. To analyze the behavior of the theoretical model, a database of 109 specimens available in the literature was collected. The model yielded an average model-to-test shear strength ratio of 0.98 and a coefficient of variation of 0.16, showing also that most test variables are well captured with the model, and providing better results than the original model. The model strength prediction is compared with other models in the literature, resulting in one of the most accurate estimates.

An Experimental Study on the Thermal Performance of a Concentric Annular Heat Pipe

  • Boo Joon Hong;Park Soo Yong;Kim Do Hyoung
    • Journal of Mechanical Science and Technology
    • /
    • 제19권4호
    • /
    • pp.1036-1043
    • /
    • 2005
  • Concentric annular heat pipes (CAHP) were fabricated and tested to investigate their thermal characteristics. The CAHPs were 25.4 mm in outer diameter and 200 mm in length. The inner surface of the heat pipes was covered with screen mesh wicks and they were connected by four bridge wicks to provide liquid return path. Three different heat pipes were fabricated to observe the effect of change in diameter ratios between 2.31 and 4.23 while using the same outer tube dimensions. The major concern of this study was the transient response as well as isothermal characteristics of the heat pipe outer surface, considering the application as uniform heating device. A better performance was achieved as the diameter ratio increased. For the thermal load of 180 W, the maximum temperature difference on the outer surface in the axial direction of CAHP was $2.3^{\circ}C$ while that of the copper block of the same outer dimension was $5.9^{\circ}C.$ The minimum thermal resistance of the CAHP was measured to be $0.004^{\circ}C/W.$ In regard to the transient response during start-up, the heat pipe showed almost no time lag to the heat source, while the copper block of the same outer dimensions exhibited about 25 min time lag.

Prediction of Shear Strength of R/C Beams using Modified Compression Field Theory and ACI Code

  • Park, Sang-Yeol
    • KCI Concrete Journal
    • /
    • 제11권3호
    • /
    • pp.5-17
    • /
    • 1999
  • In recent years. the concept of the modified compression field theory (MCFT) was develped and applied to the analysis of reinforced concrete beams subjected to shear, moment, and axial load. Although too complex for regular use in the shear design or beams. the procedure has value in its ability to provide a rational method of anlysis and design for reinforced concrete members. The objective of this paper is to review the MCFT and apply it for the prediction of the response and shear strength of reinforced concrete beams A Parametric analysis was Performed on a reinforced T-section concrete beam to evaluate and compare the effects of concrete strength. longitudinal reinforcement ratio shear reinforcement ratio, and shear span to depth ratio in two different approaches the MCFT and the ACI code. The analytical study showed that the concrete contribution to shear strength by the MCFT was higher than the one by the ACI code in beams without stirrups, while it was lower with stirrups. On the other hand. shear reinforcement contribution predicted by the MCFT was much higher than the one by the ACI code. This is because the inclination angle of shear crack is much smaller than 45$^{\circ}$assumed in the ACI code.

  • PDF

형상비 2.5 RC 교각의 곡률분석평가 (Evaluation of Curvature Analysis at RC Bridge Piers in an aspect ratio of 2.5)

  • 박창규;정영수;이은희;김영섭
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 추계 학술발표회논문집
    • /
    • pp.263-270
    • /
    • 2003
  • Before the implementation of the 1992 seismic design provisions in Korea, longitudinal steels of RC bridge piers were practically lap-spliced in the plastic hinge region. Experimental investigation was made to evaluate the seismic performance of RC bridge pier specimens in a flexure/shear mode. Six circular test specimens in an aspect ratio of 2.5 (600mm in diameter) were made with test parameters confinement ratio, lap splices, and retrofit FRP materials. They were damaged under a series of artificial earthquakes with 0.22g PGA, being compatible in Korean peninsula, through the pseudo-dynamic test. Probable damages were assessed by the Park and Ang damage index. Approximate 0.1 and 0.3 damage indices were obtained for RC specimens without lap splice and with lap splice, respectively. Directly after the pseudo-dynamic test, damaged test columns were laterally actuated under inelastic reversal cyclic loadings simultaneously under a constant axial load. Through curvature measurements, residual seismic performance was evaluated for test specimens. Test results show that RC pier specimens with lap-spliced appeared to fail at low ductility, but significant improvement was obtained for the ductility of these specimens if externally wrapped with FRP.

  • PDF

Seismic behavior and strength of L-shaped steel reinforced concrete column-concrete beam planar and spatial joints

  • Chen, Zongping;Xu, Deyi;Xu, Jinjun;Wang, Ni
    • Steel and Composite Structures
    • /
    • 제39권3호
    • /
    • pp.337-352
    • /
    • 2021
  • The study presented experimental and numerical investigation on the seismic performance of steel reinforced concrete (SRC) L-shaped column- reinforced concrete (RC) beam joints. Various parameters described as steel configuration form, axial compressive ratio, loading angle, and the existence of slab were examined through 4 planar joints and 7 spatial joints. The characteristics of the load-displacement response included the bearing capacity, ductility, story drift ratio, energy-dissipating capacity, and stiffness degradation were analyzed. The results showed that shear failure and flexural failure in the beam tip were observed for planar joints and spatial joint, respectively. And RC joint with slab failed with the plastic hinge in the slab and bottom of the beam. The results indicated that hysteretic curves of spatial joints with solid-web steel were plumper than those with hollow-web specimens. The capacity of planar joints was higher than that of space joints, while the opposite was true for energy-dissipation capacity and ductility. The high compression ratio contributed to the increase in capacity and initial stiffness of the joint. The elastic and elastic-plastic story deformation capacity of L-shaped column frame joints satisfied the code requirement. A design formula of joint shear resistance based on the superposition theory and equilibrium plasticity truss model was proposed for engineering application.

하중증폭계수를 적용한 비대칭 비가새 골조 2차 해석 평가 (Evaluation of the Second Order Analysis of Asymmetric Unbraced Frame by using Load Amplification Factor)

  • 김희동
    • 한국강구조학회 논문집
    • /
    • 제22권1호
    • /
    • pp.87-97
    • /
    • 2010
  • 본 연구는 비대칭 비가새 골조를 대상으로 강구조 설계기준에서 제시하고 있는 하중증폭계수를 적용한 2차 해석법의 타당성을 해석적 방법을 통해 평가하는데 그 목적이 있다. 이를 위해 KBC 2005에서 제안하고 있는 B1 및 B2 계수를 적용한 2차 해석과 KBC 2009에서 제안하고 있는 하중증폭계수를 적용한 직접해석을 5층 2스팬 및 5층 4스팬 비대칭 비가새 강구조 골조에 대해 실시하고, 그 해석 결과를 2차 비탄성 해석 결과와 비교하여 기준에서 제안된 2차 해석법들을 평가하였다. 해석의 주요 변수로는 골조 형상, 기둥 축력비, 해석방법, 기둥수평위치 등이 적용되었다. 연구 결과 구조물의 비대칭성은 B2 계수 및 제안된 해석법의 유효성에 영향을 미치는 것으로 나타났으며, 특히 기둥삭제 및 경사 기둥의 경우 오차의 범위가 증가하는 것으로 나타났다.

철근 콘크리트 전단벽에서 면외 하중이 면내 전단성능에 미치는 영향 (The Effect of Out-of-Plane Load on the In-Plane Shear Capacity of Reinforcement Concrete Shear Wall)

  • 신혜민;박준희
    • 한국지진공학회논문집
    • /
    • 제28권2호
    • /
    • pp.77-83
    • /
    • 2024
  • The design shear strength equations of RC shear walls have been developed based on their performance under in-plane (IP) loads, thereby failing to account for the potential performance degradation of shear strength when subjected to simultaneous out-of-plane (OOP) loading. Most of the previous experimental studies on RC walls have been conducted in one direction under quasi-static conditions, and due to the difficulty in experimental planning, there is a lack of research on cyclic loading and results under multi-axial loading conditions. During an earthquake, shear walls may yield earlier than their design strength or fail unexpectedly when subjected to multi-directional forces, deviating from their intended failure mode. In this paper, nonlinear analysis in finite element models was performed based on the results of cyclic loading experiments on reinforced concrete shear walls of auxiliary buildings. To investigate the reduction trend in IP shear capacity concerning the OOP load ratio, parametric analysis was conducted using the shear wall FEM. The analysis results showed that as the magnitude of the OOP load increased, the IP strength decreased, with a more significant effect observed as the size of the opening increased. Thus, the necessity to incorporate this strength reduction as a factor for the OOP load effect in the wall design strength equation should be discussed by performing various parametric studies.

Experiment and bearing capacity analyses of dual-lintel column joints in Chinese traditional style buildings

  • Xue, Jianyang;Ma, Linlin;Wu, Zhanjing;Zhai, Lei;Zhang, Xin
    • Steel and Composite Structures
    • /
    • 제28권5호
    • /
    • pp.641-653
    • /
    • 2018
  • This paper presents experiment and bearing capacity analyses of steel dual-lintel column (SDC) joints in Chinese traditional style buildings. Two SDC interior joints and two SDC exterior joints, which consisted of dual box-section lintels, circular column and square column, were designed and tested under low cyclic loading. The force transferring mechanisms at the panel zone of SDC joints were proposed. And also, the load-strain curves at the panel zone, failure modes, hysteretic loops and skeleton curves of the joints were analyzed. It is shown that the typical failure modes of the joints are shear buckling at bottom panel zone, bending failure at middle panel zone, welds fracturing at the panel zone, and tension failure of base metal in the heat-affected zone of the joints. The ultimate bearing capacity of SDC joints appears to decrease with the increment of axial compression ratio. However, the bearing capacities of exterior joints are lower than those of interior joints at the same axial compression ratio. In order to predict the formulas of the bending capacity at the middle panel zone and the shear capacity at the bottom panel zone, the calculation model and the stress state of the element at the panel zone of SDC joints were studied. As the calculated values showed good agreements with the test results, the proposed formulas can be reliably applied to the analysis and design of SDC joints in Chinese traditional style buildings.

Seismic behavior of stiffened concrete-filled double-skin tubular columns

  • Shekastehband, B.;Mohammadbagheri, S.;Taromi, A.
    • Steel and Composite Structures
    • /
    • 제27권5호
    • /
    • pp.577-598
    • /
    • 2018
  • The imperfect steel-concrete interface bonding is an important deficiency of the concrete-filled double skin tubular (CFDST) columns that led to separating concrete and steel surfaces under lateral loads and triggering buckling failure of the columns. To improve this issue, it is proposed in this study to use longitudinal and transverse steel stiffeners in CFDST columns. CFDST columns with different patterns of stiffeners embedded in the interior or exterior surfaces of the inner or outer tubes were analyzed under constant axial force and reversed cyclic loading. In the finite element modeling, the confinement effects of both inner and outer tubes on the compressive strength of concrete as well as the effect of discrete crack for concrete fracture were incorporated which give a realistic prediction of the seismic behavior of CFDST columns. Lateral strength, stiffness, ductility and energy absorption are evaluated based on the hysteresis loops. The results indicated that the stiffeners had determinant role on improving pinching behavior resulting from the outer tube's local buckling and opening/closing of the major tensile crack of concrete. The lateral strength, initial stiffness and energy absorption capacity of longitudinally stiffened columns with fixed-free end condition were increased by as much as 17%, 20% and 70%, respectively. The energy dissipation was accentuated up to 107% for fixed-guided end condition. The use of transverse stiffeners at the base of columns increased energy dissipation up to 35%. Axial load ratio, hollow ratio and concrete strength affecting the initial stiffness and lateral strength, had negligible effect of the energy dissipation of the columns. It was also found that the longitudinal stiffeners and transverse stiffeners have, respectively, negative and positive effects on ductility of CFDST columns. The conclusions, drawn from this study, can in turn, lead to the suggestion of some guidelines for the design of CFDST columns.