• 제목/요약/키워드: Axial Flow Impeller

검색결과 88건 처리시간 0.287초

원심형, 사류형, 축류형 펌프단에서 살펴본 이차유동의 수치적 고찰 (Numerical Investigation of Secondary Flow in 3 Pump Stages: Centrifugal Multistage/Mixed-flow Stage/ Axial-flow Stage)

  • 오종식
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2005년도 연구개발 발표회 논문집
    • /
    • pp.359-364
    • /
    • 2005
  • Centrifugal pump shows the strongest secondary flow. Wake is formed near pressure surface close to hub at impeller exit for centrifugal pump impeller. Pressure gradient drives secondary flow in the inducer region, while in the remaining region the following sources drive together: > Pressure gradient > Coriolis force Low-momentum fluid near suction surface hub moves toward pressure surface hub in mixed-flow pump impeller. Tip leakage vortex dominate secondary flow in axial-flow pump impeller. Tip leakage vortex dominate secondary flow in axial-flow in axial-flow pump impeller

  • PDF

스러스트 래버린스 실을 배면에 갖는 원심형 임펠러의 축력 해석 (Analysis of the Axial Thrust Force of a Centrifugal Impeller with a Thrust Labyrinth Seal at its Backside)

  • 박준혁;김태호
    • Tribology and Lubricants
    • /
    • 제37권1호
    • /
    • pp.31-40
    • /
    • 2021
  • This study describes the effects of a thrust labyrinth seal applied to the backside of a centrifugal impeller on the axial thrust force for high speed turbomachinery. The bulk flow model using Neumann's equation calculates the seal cavity pressures and leakage flow rate of the thrust labyrinth seal based on three configurations: teeth-on-rotor (TOR), teeth-on-stator (TOS), and interlocking labyrinth seal (ILS). Prediction results show that the ILS is superior to the TOR and TOS in terms of leakage flow rate. A mathematical model of a centrifugal impeller with a thrust labyrinth seal on its backside calculates the force components corresponding to the impeller inlet, shroud, impeller backside outer, backside seal, and backside inner pressures. A summation of the force components renders the total axial thrust force acting on the centrifugal impeller. The Newton-Raphson numerical scheme iteratively calculates the pressures and leakage flow rate through the impeller wall gap. The prediction results reveal that the leakage flow rate and total axial thrust force increase with rotor speed, and the ILS significantly decreases the leakage flow rate, whereas it slightly increases the axial thrust force when compared to TOR and TOS. Increasing the seal clearance causes an increase in the leakage flow rate and a slight decrease in the axial thrust force with the ILS.

CFD를 활용한 축류형 혈액펌프의 펌프 특성 해석 (Pump performance analysis of Axial Flow Blood Pump using CFD)

  • 최승한;김동욱
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2003년도 춘계학술발표논문집
    • /
    • pp.288-290
    • /
    • 2003
  • Artificial heart is divided by pulsation flow type and continuous flow type according to blood circulation pattern. Axial flow blood pump is a kind of continuous flow type artificial heart. Axial flow blood pump would be different pump performance according to impeller's shape and rotating velocity. Pump performance be able to compare by flow rate according to differential pressure and Impeller's rotating velocity. It confirms Impeller model of better efficiency according to compare Pump performance of axial flow blood pump using CFD with actual experiment result.

  • PDF

심장내 이식형 축류 혈액펌프의 in-vitro특성에 관한 연구 (A Study of in-vitro Performances of the Intracardiac Axial Flow Pump)

  • 김동욱;삼전부호희
    • 대한의용생체공학회:의공학회지
    • /
    • 제19권1호
    • /
    • pp.33-38
    • /
    • 1998
  • 심장내 이식형 축류 혈액 펌프의 개발을 시도하였다. 이 펌프는 해부학적인 적합성이 좋고, 혈액과 접촉하는 면적이 적으며, 심장판막의 위치에 이식할 수 있어 이식술이 용이한 등의 이점이 있다. 축류혈액펌프는 입펠러와 소형 모터에 의해 구성되었으며, 모터축과 펌프의 본체의 밀봉은 자성유체 축봉이 이용되었다. 본 연구에서 개발한 혈액펌프의 펌프 특성은 4매 임펠러의 경우 회전수 7091[rmp], 6매 임펠러의 경우 회전수 6402[rpm]에서 유량 5[l/min], 차압 100[mmHm]을 얻을 수 있었으며, 자성유체 축봉의 내압 특성은 회전수 7000[rpm], 압력ㄹ 150[mmHg]에서 24시간 이상의 내구성을 얻을 수 있었다. 그리고, 용혈에 대하여 검토한 결과 4매 임펠러의 1H 는 0.0561[g/100L]이고, 6매 임펠러의 경우는 1H=0.214[g/100L]을 얻을 수 있었다. 이상의 실험결과는 심장내 이식 축류형 혈액펌프의 실현 가능성을 보여 주는 것으로 앞으로 큰 기대를 걸수 있다고 생각된다.

  • PDF

밀폐된 원통내부에서 회전체의 형상에 따른 혼합효과에 대한 LDV 측정 (LDV Measurement for the Mixing Effect of the Rotator Shape in a Confined Cylinder)

  • 박천수;김유곤
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.720-726
    • /
    • 2001
  • Two-dimensional, angle-resolved LDV(Laser Doppler Velocimetry) measurements of the turbulent rotating flow field in a confined cylinder have been performed. The configurations of interest are flows between a rotating upper disk with a rod attached by a disk or impeller(${\theta}= 90^{\circ},\;45^{\circ}$) and a stationary lower disk in a confined cylinder. The mean flow velocity as well as the turbulent intensity of the flow field have been measured. The results show that the flow is strongly dependent on the position of the impellers or the disk, negligibly affected by the Reynolds number in turbulent flow. It is observed that the mixing effect of the axial flow impeller(${\theta}= 45^{\circ}$) is better than that of the radial flow impeller(${\theta}= 90^{\circ}$) or a disk.

  • PDF

물질전달계수를 이용한 생물 반응기 운전 최적화 (Optimization of Bioreactor Operation by Mass Transfer Coefficient)

  • 김형순
    • 한국산업융합학회 논문집
    • /
    • 제4권3호
    • /
    • pp.243-251
    • /
    • 2001
  • The effects of various operating parameters(agitation speed, impeller type, antiform agents, impeller spacing etc.) on air-liquid mass transfer was characterized by volumetric mass transfer coefficient($k_La$). Also, the dual-impeller agitated systems are compared with single-impeller agitated systems with a special focus on its applications for bioreactors, $k_La$ was take over a range of 200~450 rpm of agitation speed, and 0.5~2.5 vvm of air flow rates, for four single impeller and impeller combinations consisting of four impeller types, namely rushton, pitched blade, scaba, intermig were tested. The rushton impeller showed the best $k_La$ as compared with other single impellers. The dual impeller system are found to be superior as compared to single impeller in all aspects, The best combination of the dual impeller was a intermig of axial flow type as an upper impeller and a rushton of radial flow type as a lower part. Also, the control of the DO level with the variation of agitation speed was more efficient than that with an increase in air flow rate. The addition of antiform dropped the $k_La$ very large up to 1g/L regardless the type. PPG was less effect on $k_La$ than other antiforms. The impeller spacing and presence of solute are found very effective on $k_La$. When the $NaNO_3$is presented as solute, the $k_La$ increased approximately 50% then control.

  • PDF

밀폐된 원통내부에서 회전체의 형상이 회전유동에 미치는 영향에 관한 실험적 연구 (Experimental Study for the Influence of Rotator Shape on the Rotating Flow in a Confined Cylinder)

  • 김유곤;박천수
    • 대한기계학회논문집B
    • /
    • 제26권5호
    • /
    • pp.675-684
    • /
    • 2002
  • Two-dimensional, angle-resolved LDV(Laser Doppler Velocimetry) measurements of the turbulent rotating flow field in a confined cylinder have been performed. The configurations of interest are flows between a rotating upper disk with a rod attached by a disk or impeller($\theta$ = 45$^{\circ}$, 90$^{\circ}$) and a stationary lower disk in a confined cylinder. The mean flow velocity as well as the turbulent intensity of the flow field have been measured. The results show that the flow is strongly dependent on the position of the impellers or the disk, negligibly affected by the Reynolds number in turbulent flow. It is observed that the mixing effect of the axial flow impeller($\theta$ = 45$^{\circ}$) is better than that of the radial flow impeller($\theta$ = 90$^{\circ}$) or a disk.

환기용 축류송풍기의 유동해석 및 모터 위치에 따른 성능 특성 연구 (Flow Analysis and Performance Evaluation of a Ventilation Axial-Flow Fan Depending on the Position of Motor)

  • 김재우;김진혁;김광용
    • 한국유체기계학회 논문집
    • /
    • 제13권4호
    • /
    • pp.25-30
    • /
    • 2010
  • Flow analysis and performa nce evaluation have been performed for a ventilation axial-flow fan with different positions of the motor. Two different positions of motor have been tested; one is in front of the impeller and the other is behind the impeller. Flow analyses are performed by solving three-dimensional Reynolds-averaged Navier-Stokes equations through a finite-volume solver. Preliminary numerical calculations are carried out to test the performances of different turbulence models, i.e., SST model, k-$\omega$ model, and k-$\varepsilon$ model with and without using empirical wall function in the flow analysis. The validation of numerical analyses has been performed in comparison with the experimental data. The numerical results for the performance characteristics of the ventilation axial-flow fan with two different positions of the motor have been presented.

피치각 수정에 따른 축류식 터보팬 성능 변화에 관한 연구 (Performance of an Axial Turbo Fan by the Revision of Impeller Pitch Angle)

  • 강석윤;이태구;류인근;이재헌
    • 설비공학논문집
    • /
    • 제17권3호
    • /
    • pp.268-276
    • /
    • 2005
  • The aim of this paper is to suggest one efficient method for the various requirements of performance during the process designing and producing an impeller. The study considers that the revisions of a pitch angle of an impeller at an axial turbo fan affect an air flow rates and a static pressure rise. The axial turbo fan specified with the 250 Pa maximum static pressure and 1300 CMH fan air flow rates was tested and analyzed by CFD. The Numerical results show that the air flow rates are calculated to 1,175 CMH, 1,223 CMH, 1,270 CMH, 1,340 CMH and 800 CMH in cases that the pitch angles are $44^{\circ},\;49^{\circ},\;54^{\circ},\;59^{\circ},\;and\;64^{\circ}$ respectively. Also the static pressure rises are shown to 108 Pa, 122Pa, 141 Pa, 188 Pa and 63 Pa at the same cases. The air flow rate is increased linearly according to the changes of the pitch angle from $44^{\circ}\;to\;59^{\circ}$ and the maximum air flow rate passing the impeller is increased to $13\%$ over at the case of $59^{\circ}$ pitch angle compared with the reference case of $54^{\circ}$ pitch angle. The static pressure rise is increased linearly according to the changes of the pitch angle from $44^{\circ}\;to\;54^{\circ}$, too. The static pressure rise at the $59^{\circ}$ pitch angle is increased to $33\%$ over compared with the $54^{\circ}$ pitch angle. The result shows that the revisions of pitch angle make the static pressure rise increase widely. However the air flow rates and the static pressure rise at the $64^{\circ}$ pitch angle are suddenly decreased because of over-changed pitch angle.