• Title/Summary/Keyword: Axial Data

Search Result 1,062, Processing Time 0.024 seconds

An Experimental Study on the Atomization Characteristics of a Two-Phase Turbulent Jet of Liquid Sheet Type Co-Axial Nozzle (액막형 동축노즐의 2상 난류분사의 미립화 특성에 관한 실험적 연구)

  • 노병준;강신재;오제하
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.6
    • /
    • pp.1529-1538
    • /
    • 1995
  • In this study, a liquid sheet type co-axial nozzle has been used to investigate the turbulent atomization characteristics which could result in the experimental data to be used in designing a jet nozzle with high performance. Image processing technique and immersion sampling method were employed to measure droplet size. In atomizing characteristics, droplet size distributions and absolute droplet sizes, SMD(Sauter Mean Diameter) have been investigated in the wide ranges of flow field depending upon the air-water mass ratios. And the comparisons between the present data and the semi-empirical curves have been conducted semi-empirical correlation for SMD has been derived in the present analysis.

An Experimental study on the Broadband Noise Generation in Axial Flow Fan (축류팬에서의 광대역소음 발생에 대한 실험적 연구)

  • Rhee, Wook;Choi, Jong-Soo
    • 유체기계공업학회:학술대회논문집
    • /
    • 1998.12a
    • /
    • pp.91-96
    • /
    • 1998
  • The broadband noise generated aerodynamically from a two-bladed axial flow fan has been measured and compared to the result of a self-noise prediction method. The prediction scheme is based on the experimental data set acquired from a series of aerodynamic and acoustic tests of two and three-dimensional airfoil blade sections. For low blade loading case the comparison showed a reasonably good agreement, but as the loading becomes larger the empirical formula overpredict the sound pressure level at high frequency range. This is probably due to the use of stationary wing data for the prediction of rotating blade case, which will be quite different in their vortex strength at the blade tip.

  • PDF

A Benchmark study on ultimate strength formulations of the aluminium stiffened panels under axial compression (알루미늄합금 보강판의 압축 최종강도 설계식의 비교연구)

  • ;;;O.F., Hughes;P.E., Hess
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2004.10a
    • /
    • pp.110-117
    • /
    • 2004
  • The aim of a benchmark study is carried out nine methods are employed for ULS analysis which implicitly predict the ultimate strength of aluminium stiffened panels under axial compression. For this purpose, DNV PULS, experimental and numerical data on the ultimate strength of panels were collected. Comparison of these experimental / numerical, DNV PULS / numerical, results with theoretical solutions by the candidate methods is performed. Also it's compared that ALPS/ULSAP program is based on closed-form formula for the ULS of plates and grillages under axial compression. It is considered that ALPS/ULSAP methodology provides quite accurate and reasonable ULS calculations by a comparison with more refined FEA. Comparison of these experimental data, numerical, computational software results with the simplified solutions obtained by the candidate methods is then performed. The model uncertainties associated with the candidate methods are studied in terms of mean bias and COV (i.e., coefficient of variation) against experiments and numerical solutions, and the relative performance of the various methods is discussed.

  • PDF

Effective Performance Prediction of Axial Flow Compressors Using a Modified Stage-Stacking Method (단축적법의 개선에 의한 축류압축기의 효과적인 성능예측)

  • Song, Tae-Won;Kim, Jae-Hwan;Kim, Tong-Seop;Ro, Sung-Tack
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.8
    • /
    • pp.1077-1084
    • /
    • 2000
  • In this work, a modified stage-stacking method for the performance prediction of multi-stage axial flow compressors is proposed. The method is based on a simultaneous calculation of all interstage variables (temperature, pressure, flow velocity) instead of the conventional sequential stage-by-stage scheme. The method is also very useful in simulating the effect of changing angles of the inlet guide vane and stator vanes on the compressor operating characteristics. Generalized stage performance curves are used in presenting the performance characteristics of each stage. General assumptions enable determination of flow path data and stage design performance. Performance of various real compressors is predicted and comparison between prediction and field data validates the usefulness of the present method.

The Seismic Design of Axial Blower Using Ansys (Ansys를 이용한 축류송풍기의 내진설계)

  • Im, Hyung-Bin;Kim, Kang-Sung;Heo, Jin-Wook;Chung, Jin-Tai
    • Proceedings of the KSME Conference
    • /
    • 2001.06b
    • /
    • pp.596-600
    • /
    • 2001
  • The seismic design for an axial blower is the procedure in which the required response spectrum (RRS) is computed by using the floor response spectrum (FRS). The seismic design is very important to reduce severe damages from an earthquake; therefore, the seismic design has been a great concern in engineering society. In this study, after finite element modeling is established by using Ansys, the modal data are obtained such as the natural frequencies, the participation factor, and so on. With these data, the RRS is acquired by a numerical approach. The seismic safety of the axial blower is evaluated.

  • PDF

Applicability of Existing Fracture Initiation Models to Modern Line Pipe Steels

  • Shim, Do Jun
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.12 no.2
    • /
    • pp.1-24
    • /
    • 2016
  • The original fracture criteria developed by Maxey/Kiefner for axial through-wall and surface-cracked pipes have worked well for many industries for a large variety of relatively low strength and toughness materials. However, newer line pipe steels have some unusual characteristics that differ from these older materials. One example is a test data that has demonstrated that X80 line-pipe with an axial through-wall-crack can fail at pressures about 30 percent lower than predicted with commonly used analysis methods for older steels. Thus, it is essential to review the currently available models and investigate the applicability of these models to newer high-strength line pipe materials. In this paper, the available models for predicting the failure behavior of axial-cracked pipes (through-wall-cracked and external surface-cracked pipes) were reviewed. Furthermore, the applicability of these models to high-strength steel pipes was investigated by analyzing limited full-scale pipe fracture initiation test results. Based on the analyzed results, the shortcomings of the available models were identified. For both through-wall and surface cracks, the major shortcomings were related to the characterization of the material toughness, which generally leads to non-conservative predictions in the J-T analyses. The findings in this paper may be limited to the test data that were consider for this study. The requisite characteristics of a potential model were also identified in the present paper.

Flow Analysis in the Tip Clearance of Axial Flow Rotor Using Finite-Element Large-Eddy Simulation Method (유한요소 LES법에 의한 축류 회전차 팁 틈새의 유동해석)

  • Lee, Myeong-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.5
    • /
    • pp.686-695
    • /
    • 2009
  • Flow characteristics in linear axial cascade have been studied using large eddy simulation(LES) based on finite element method(FEM) to investigate details of the leakage flow in the tip clearance of axial flow rotor. STAR-CD(FVM) and PAT-Flow(FEM) have been adopted to solve the Navier-Stokes equations for the simulation of the unsteady turbulent flow. Numerical results from the present study have been compared with the existing experimental results to investigate a tip clearance effect on velocity profile and static pressure distribution on blade surface at various spanwise positions. Both simulation results agree well with the experimental data. However, it has been shown that the results of finite-element large-eddy simulation agree better with experimental data than $k-{\varepsilon}$ turbulent model based on finite volume method regarding the tip vortex geometry and static pressure distribution at the center of the tip vortex core. As a result of this study, it is shown that finite-element large-eddy simulation method can predict more exactly on the tip leakage vortex flow and behind flow field.

The Study on Interrelationship Analysis of Domestic Road Using PSD (PSD선도를 이용한 국내노면의 상관성 분석에 관한 연구)

  • Kim, Chan-Jung;Kwon, Seong-Jin;Lee, Bong-Hyun;Kim, Hyun-Chul;Bae, Chul-Yong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.8 s.113
    • /
    • pp.806-813
    • /
    • 2006
  • An important factor of vibration test using MAST(multi axial simulation table) system is the reliance of input excitation source. Generally the generation of input excitation source is obtained by the measured data on special road in proving ground. The measured data on special road have more exciting energy than the data of real fields, therefore the time and expense for test can be reduced. But the magnitude of input excitation source must be defined by comparison with the excited energy on real field. The object of this paper makes the data base of domestic roads for the definition of input excitation source which is obtained by the measured data on special road in proving ground. These real field data on domestic roads are analyzed by the power spectral density and interrelationship index.

An Analytical Study on Encased Steel Composite Columns Fire Resistance According to Axial Force Ratio (화재시 축력비에 따른 매입형 합성기둥의 내화성능에 대한 해석적 연구)

  • Kim, Ye-Som;Choi, Byong-Jeong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.1
    • /
    • pp.97-107
    • /
    • 2020
  • In this study, finite element analysis was carried out through the finite element analysis program (ANSYS) to investigate the fire resistance of composite columns in fire. Transient heat transfer analysis and static structural analysis were performed according to ASTM E 119 heating curve and axial force ratio 0.7, 0.6, 0.5 by applying stress-strain curves according to temperature, and loading heating experiments were carried out under the same conditions. In addition, the nominal compressive strength of the composite column according to the heating time according to the standard(Eurocode 4) was calculated and expressed as the axial force ratio and compared with the analytical and experimental values. Through the analysis, As a result of finite element analysis, the fire resistance time was 180 minutes and similar value to the experimental value was obtained, whereas the fire resistance time 150 minutes and 60 minutes were derived from the axial force ratios 0.6 and 0.7. In addition, it was confirmed that the fire resistance time according to the axial force ratio calculated according to the reference equation (Eurocode 4) was lower than the actual experimental value. However, it was confirmed that the standard(Eurocode 4) was higher than the experimental value at the axial force ratio of 0.7. Accordingly, it is possible to confirm the fire resistance characteristics(time-axial force ratio relationship) of the SRC column at high axial force, and to use the experimental and anaylsis data of the SRC column as the data for verification based on Eurocode.

Two dimensional analysis of axial segregation by convection-diffusion model in batchwise and continuous Czochralski process

  • Wang, Jong-Hoe;Kim, Do-Hyun
    • Proceedings of the Korea Association of Crystal Growth Conference
    • /
    • 1997.10a
    • /
    • pp.117-121
    • /
    • 1997
  • It is shown theoretically that uniform axial dopant concentration distribution can be made throughout the crystal by continuous Czochralski process. Numerical simulation are performed for the transient two-dimensional convection-diffusion model. A typical value of the growth and system parameters for Czochralski growth of p-type, 4 inches silicon crystal was used in the numerical calculations. Using this model with proper model parameter, the axial segregation in batchwise Czochralski growth can be described. It is studied by comparing with the experimental data. With this model parameter, the uniform axial concentration distribution of dopant is predicted in continuous Czochralski process.

  • PDF