Kim, Hyuk;So, Eunsun;Karm, Myong-Hwan;Kim, Hyun Jeong;Seo, Kwang-Suk
Journal of Dental Anesthesia and Pain Medicine
/
v.17
no.4
/
pp.297-305
/
2017
Background: Fiberoptic nasotracheal intubation (FNI) is performed if it is difficult to open the mouth or if intubation using laryngoscope is expected to be difficult. However, training is necessary because intubation performed by inexperienced operators leads to complications. Methods: Every resident performed intubation in 40 patients. Success of FNI was evaluated as the time of FNI. First intubation time was restricted to 2 min 30 s. If the second attempt was unsuccessful, it was considered a failed case, and a specialist performed nasotracheal intubation. If the general method of intubation was expected to be difficult, awake intubation was performed. The degree of nasal bleeding during intubation was also evaluated. Results: The mean age of the operators (11 men, 7 women) was 27.8 years. FNI was performed in a total of 716 patients. The success rate was 88.3% for the first attempt and 94.6% for the second attempt. The failure rate of intubation in anesthetized patients was 4.9%, and 13.6% in awake patients. When intubation was performed in anesthetized patients, the failure rate from the first to fifth trial was 9.6%, which decreased to 0.7% when the number of trials increased to > 30 times. In terms of awake intubation, there was no failed attempt when the resident had performed the FNI > 30 times. The number of FNIs performed and nasal bleeding were important factors influencing the failure rate. Conclusion: The success rate of FNI increased as the number of FNI performed by residents increased despite the nasal bleeding.
Kim, Hye-Jin;Kim, So-Hyun;Kim, Tae-Heung;Yoon, Ji-Young;Kim, Cheul-Hong;Kim, Eun-Jung
Journal of Dental Anesthesia and Pain Medicine
/
v.17
no.4
/
pp.313-316
/
2017
Mask ventilation, the first step in airway management, is a rescue technique when endotracheal intubation fails. Therefore, ordinary airway management for the induction of general anesthesia cannot be conducted in the situation of difficult mask ventilation (DMV). Here, we report a case of awake intubation in a patient with a huge orocutaneous fistula. A 58-year-old woman was scheduled to undergo a wide excision, reconstruction with a reconstruction plate, and supraomohyoid neck dissection on the left side and an anterolateral thigh flap due to a huge orocutaneous fistula that occurred after a previous mandibulectomy and flap surgery. During induction, DMV was predicted, and we planned an awake intubation. The patient was sedated with dexmedetomidine and remifentanil. She was intubated with a nasotracheal tube using a video laryngoscope, and spontaneous ventilation was maintained. This case demonstrates that awake intubation using a video laryngoscope can be as good as a fiberoptic scope.
Journal of The Korean Dental Society of Anesthesiology
/
v.8
no.2
/
pp.118-121
/
2008
Background: This retrospective study aims to describe the airway management and to search predictive parameter for difficult intubation in 700 patients undergoing oromaxillary surgery. Methods: The medical records of 700 patients undergone oromaxillary surgery were reviewed for airway management during perioperative period. The cases of difficult intubation were selected and those radiologic findings were reviewed. The mandibular depth (MD), mandibular length (ML), thyromental distance (TMD) were measured. Results: In 41 cases difficult intubation were recorded in anesthetic record. The grade of Cormack and Lehane was III in 36 patients and IV in 5 cases. The MD of difficult intubation cases was $4.2{\pm}3.2\;cm$. The ML of difficult intubation cases was $10.1{\pm}3.8\;cm$. The TMD of difficult intubation cases was $5.9{\pm}4.3\;cm$. Under the fiberoptic guided awake intubation was undertaken in 75 patient. In none of the cases was failed nasotracheal intubation. Conclusions: The patients undergoing oromaxillar surgery have a potentially difficult airway but, if managed properly during perioperative preiod, morbidity and mortality can be reduced or avoided. The radiologic findings were poor predict for difficult intubation. The fiberoptic guided awake intubation is a safe alternative to direct laryngoscopic intubation.
Journal of The Korean Dental Society of Anesthesiology
/
v.10
no.2
/
pp.190-196
/
2010
Difficult airway management including difficult intubation, difficult ventilation and difficult mask ventilation is a life threatening issue during anesthesia care. A 23-year-old woman with Treacher Collins syndrome was scheduled for distraction osteogenesis. She had hypoplasia of mandible and malar bone, bilateral deformities of auricles with partial deafness and antimongoloid slant of the palpebral fissures. A 56-year-old woman with mandibular hypoplasia due to childhood trauma was scheduled for distraction osteogenesis. She had a history of difficult intubation. We anticipated a difficult intubation and ventilation. Fiberoptic bronchoscopic guided awake intubation was selected for anesthesia induction. After intravenous injection of midazolam and remifentanil, 10% lidocaine pump spray on the pharyngolarynx with a direct laryngoscope and on the nasal canal. However fiberoptic bronchoscopic guided awake intubation was failed due to severe gag reflex. After intravenous injection of propofol and remifentanil using the target controlled infusion (TCI), mask ventilation was easily performed and, after intravenous injection of vecuronium, fiberoptic bronchoscopic guided intubation was easily performed using a wire reinforced endotracheal tube. The operation was completed successfully without any adverse events.
Background: Awake fiberoptic intubation (AFOI) is the procedure of choice for securing the airway in patients with a difficult airway when undergoing surgeries under general anesthesia. An ideal drug would not only provide conscious sedation but also maintain spontaneous ventilation, smooth intubation conditions, and stable hemodynamics. We compared the effects of dexmedetomidine alone and dexmedetomidine in combination with fentanyl at a dose lower than the standard dose for achieving conscious sedation during AFOI in difficult airway patients undergoing oral cancer and dental surgeries. Methods: We included 68 adult patients undergoing AFOI. The patients were randomized in two groups, wherein Group D received intravenous dexmedetomidine 1 ㎍/kg and Group DF received dexmedetomidine 0.5 ㎍/kg and fentanyl 1 ㎍/kg. The outcomes measured were airway obstruction score, intubation scores, fiberoptic intubation comfort score, sedation score, and hemodynamic variables. Results: Low-dose dexmedetomidine with fentanyl showed similar results as those with the standard dose of dexmedetomidine in terms of airway obstruction, vocal cord movement, degree of cough, degree of limb movements, and intubation comfort. However, the sedation achieved and incidence of hypotension and bradycardia were higher in Group D than in Group DF. Conclusions: A low dose of dexmedetomidine-fentanyl provides satisfactory intubation conditions as those with a standard dose of dexmedetomidine in AFOI, thereby avoiding bradycardia, hypotension, and sedation.
Awake fiberoptic nasotracheal intubation is a useful technique, especially in patients with airway obstruction. It must not only provide sufficient anesthesia, but also maintain spontaneous breathing. We introduce a method to achieve this using a small dose of fentanyl and midazolam in combination with topical anesthesia. The cases of 2 patients (1 male, 1 female) who underwent oral maxillofacial surgery are reported. They received $50{\mu}g$ of fentanyl 2-3 times (total $2.2-2.3{\mu}g/kg$) at intervals of approximately 2 min. Oxygen was administered via a mask at 6 L/min, and 0.5 mg of midazolam was administered 1-4 times (total 0.02-0.05 mg/kg) at intervals of approximately 2 min. A tracheal tube was inserted through the nasal cavity after topical anesthesia was applied to the epiglottis, vocal cords, and into the trachea through the fiberscope channel. All patients were successfully intubated. This is a useful and safe method for awake fiberoptic nasotracheal intubation.
A 47-year-old man was referred to the operating room to treat a dentigenous cyst of the mandibular bone. Initial assessment of the airway was considered normal. However, after the induction of anesthesia, we could not intubate the patient due to severe distortion of the glottis. Fiberoptic bronchoscopy and video laryngoscopy were not effective. Intubation using a retrograde wire technique was successful. After the conclusion of surgery, the patient recovered without any complications. Subsequent magnetic resonance imaging of the patient's neck showed a $6{\times}4{\times}8.6cm$ heterogeneous T2 hyperintense, T1 isointense well-enhancing mass in the prestyloid parapharyngeal space. The patient was scheduled for excision of the mass. We planned awake intubation with fiberoptic bronchoscopy. The procedure was successful and the patient recovered without complications. Anesthetic induction can decrease the muscle tone of the airway and increase airway distortion. Therefore, careful airway assessment is necessary.
Journal of The Korean Dental Society of Anesthesiology
/
v.13
no.2
/
pp.51-54
/
2013
A 30-year-old man with morbid obesity (height: 176 cm, body weight: 100 kg, body mass index: 32.28) was scheduled for reconstruction of the mandibular fracture. During induction of general anesthesia and nasotracheal intubation, we experienced massive epistaxis, hypoxemia and difficult airway management. Fortunately, we performed oro-tracheal intubation with direct laryngoscopy and it barely succeeded. He recovered without any residual complications and rescheduled seven days later and we successfully performed awake fiberoptic nasotracheal intubation. The patient discharged on the fourth postoperative day.
Kim, Jin-Sun;Seo, Dong-Kyun;Lee, Chang-Joon;Jung, Hwa-Sung;Kim, Seong-Su
Journal of Dental Anesthesia and Pain Medicine
/
v.15
no.3
/
pp.167-171
/
2015
When anesthesiologists encounter conditions in which intubation is not possible using a conventional direct laryngoscope, they can consider using other available techniques and devices such as fiber optic bronchoscope (FOB)-guided intubation, a laryngeal mask airway (LMA), intubating LMA (ILMA), a light wand, and the Combitube. FOB-guided intubation is frequently utilized in predicted difficult airway cases and is generally performed when the patient is awake to enable easier access to the trachea. An LMA can be introduced to ventilate the patient with relative ease, while an ILMA can be used for definite endotracheal intubation. However, occasionally, an endotracheal tube (ETT) cannot pass through the larynx, despite successful introduction of a FOB into the trachea and placement of an ILMA by the anesthesiologist. Therefore, we initially introduced an ILMA for emergent ventilation, followed by successful insertion of an ETT under FOB guidance. In this report, we describe three cases of difficult intubation using a FOB and ILMA combination approach.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.