• Title/Summary/Keyword: Average width

Search Result 1,182, Processing Time 0.03 seconds

Development of Stream Width and Bed-slope Estimation Equations for Preparing Data for Distributed Storm Runoff Model (분포형 강우-유출모형의 하도자료 구축을 위한 하폭 및 하상경사 산정공식 개발)

  • Jung, In-Kyun;Park, Jong-Yoon;Joh, Hyung-Kyung;Lee, Ji-Wan;Kim, Seong-Joon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.52 no.4
    • /
    • pp.1-10
    • /
    • 2010
  • In this study, two estimation equations for preparing stream data for distributed storm runoff model were developed by analyzing the nonlinear relation between upstream flow-length and stream width, and between upstream flow-length and stream bed-slope. The equations for stream cell were tested in Chungjudam watershed (6,661 $km^2$) using KIMSTORM. Six storm events occurring between 2003 and 2008 were selected for the model calibration and verification before the test of equations. The average values of the Nash-Sutcliffe model efficiency (ME), the volume conservation index (VCI), the relative error of peak runoff rate (EQp), and the difference of time to peak runoff (DTp) were 0.929, 1.035, 0.037, and -0.406 hr for the calibrated four storm events and 0.956, 0.939, 0.055, and 0.729 hr for the two verified storm events respectively. The estimation equations were tested to the storm events, and compared the flood hydrograph. The test result showed that the estimation equation of stream width reduced the peak runoff and delaying the time to peak runoff, and the estimation equation of stream bed-slope showed the opposite results.

Laser scribing for buried contact solar cell processing (전극함몰형 태양전지의 제조를 위한 레이저 scribing)

  • 조은철;조영현;이수홍
    • Electrical & Electronic Materials
    • /
    • v.9 no.6
    • /
    • pp.593-599
    • /
    • 1996
  • Laser scribing of silicon plays an important role in metallization including the grid pattern and the front surface geometry which means aspect ratio of metal contacts. To make a front metal electrode of buried contact solar cell, we used ND:YAG lasers that deliver average 3-4W at TEM$\_$00/ mode power to sample stage. The Q-switched Nd:YAG laser of 1.064 gm wavelength was used for silicon scribing with 20-40.mu.m width and 20-200.mu.m depth capabilities. After silicon slag etching, the groove width and depth for buried contact solar cell are -20.mu.m and 30-50.mu.m respectively. Using MEL 40 Nd:YAG laser system, we can scribe the silicon surface with 18-23.mu.m width and 20-200.mu.m depth controlled by krypton arc lamp power, scan speed, pulse frequency and beam focusing. We fabricated a buried contact Silicon Solar Cell which had an energy conversion efficiency of 18.8 %. In this case, the groove width and depth are 20.mu.m and 50.mu.m respectively.

  • PDF

Analytical and numerical investigation of the cyclic behavior of angled U-shape damper

  • Kambiz Cheraghi;Mehrzad TahamouliRoudsari
    • Steel and Composite Structures
    • /
    • v.51 no.3
    • /
    • pp.325-335
    • /
    • 2024
  • Yielding dampers exhibit varying cyclic behavior based on their geometry. These dampers not only increase the energy dissipation of the structure but also increase the strength and stiffness of the structure. In this study, parametric investigations were carried out to explore the impact of angled U-shape damper (AUSD) dimensions on its cyclic behavior. Initially, the numerical model was calibrated using the experimental specimen. Subsequently, analytical equations were presented to calculate the yield strength and elastic stiffness, which agreed with the experimental results. The outcomes of the parametric studies encompassed ultimate strength, effective stiffness, energy dissipation, and equivalent viscous damper ratio (EVDR). These output parameters were compared with similar dampers. Also, the magnitude of the effect of damper dimensions on the results was investigated. The results of parametric studies showed that the yield strength is independent of the damper width. The length and thickness of the damper have the greatest effect on the elastic stiffness. Reducing length and width resulted in increased energy dissipation, effective stiffness, and ultimate strength. Damper width had a more significant effect on EVDR than its length. On average, every 5 mm increase in damper thickness resulted in a 3.6 times increase in energy dissipation, 3 times the effective stiffness, and 3 times the ultimate strength of the model. Every 15 mm reduction in damper width and length increased energy dissipation by 14% and 24%, respectively.

Properties of PD Pulses Accompanying with Bush-type Tree in LDPE (저밀도 폴리에틸렌에서 부시형 전기트리에 수반되는 부분방전 펄스의 특성)

  • 강성화;박영국;정수현;이광우;임기조
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.12
    • /
    • pp.1055-1059
    • /
    • 1998
  • The correlation between the propagation of electrical tree and distributions of partial discharge(PD) pulses accompanying with electrical tree of bush type in low density polyethylene were discussed. We measured the growth of electrical tree by using optical microscope and PD data simultaneously. The PD data detected and analyzed were PD magnitude, repetition rate, average discharge power, average phase angle, and $\psi$-q-n distribution pattern. The average discharge power and repetition rate of PD had good linear relation with area of tree. Repetition rate and peak discharge magnitude and width of discharge phase angle increased with the tree.

  • PDF

A Study for Princess Line according to Body Type II - Focused on Body Type of H & Y - (체형에 따른 프린세스 라인 연구 II - H 체형과 Y 체형을 중심으로 -)

  • 김숙정;서미아
    • The Research Journal of the Costume Culture
    • /
    • v.9 no.6
    • /
    • pp.893-907
    • /
    • 2001
  • The main purpose is to study the effects of princess lines on different body types and to disguise any imperfection by using diverse princess lines. We separated testers body shapes into specific body types, H, Y by applying both the direct and the indirect measurements. These designs were evaluated by using the point ranking system method, and then average scores were obtained from these evaluations. Following are the results of the study: 1 These are the resulting illusion effects when the shoulder width of the Princess line was fixed. When the Princess line originated from 1/3 point of the armhole, body types Y appeared to show narrow waist width. A-line silhouette appeared to display the narrowest shoulder width. When the Princess line originated from 2/3 point of the armhole, body types H and Y appeared to exhibit narrowest waist widths, and the A-line silhouette once again displayed the narrowest shoulder width. When the Princess line originated from 1/2 point of the armhole, body type H appeared to exhibit narrow width; and H-line silhouette displayed the narrowest shoulder width 2. When the Princess lines waist w'4th was fixed in order to study illusion effects of waist widths. In this experiment, locations of Princess lines and widths of the skirt were varied. When the waist width was fixed at 6.5 cm, For the H body type, the Princess line location of 1/3 point of the armhole in H-line silhouette design exhibited the narrowest waist width. For the Y body type in A-line silhouette design, the Princess line locations of 1/3 and 1/2 points of the armhole exhibited the narrowest waist width because it displayed the hourglass effect. When the waist width was fixed at 10 cm, H body type did not exhibit any significant differences between designs. For Y body type, A-line silhouette design with the Princess line origination point at 1/3 down the armhole exhibited the narrowest waist width. 3. The illusion effects of the hip were studied by fixating the width of the skirt and varying the locations of Princess line and waist widths. In H-line skirt silhouette designs, all two body types exhibited narrow hips when the Princess line origination points were at 1/3 and 1/2 way down the armhole. For A-line skirt silhouette, H body type exhibited narrow hips when narrow waist design with the Princess line originating from 1/2 point in the shoulder was shown. Y body type exhibited narrow hips when narrow waist design with the Princess line originating from 1/3 point of the armhole and 2/3 point of the shoulder. 4. With both waist and skirt widths fixed, all two body types exhibited taller and slender postures when the Princess line originated from the shoulder compare to the armhole.

  • PDF

Geology and Ore Deposits of Kubong Gold Mine (구봉광산(九峯鑛山)의 지질(地質)과 광상(鑛床))

  • Cheon, Chan Kyu;Oh, Mihn Soo
    • Economic and Environmental Geology
    • /
    • v.3 no.3
    • /
    • pp.169-176
    • /
    • 1970
  • Kubong Gold Mine is located in Kuryongri, Sayang-myun, Chungyang-gun, Choongchung-Namdo.(latitude $36^{\circ}24^{\prime}N$. longitude $126^{\circ}45^{\prime}30^{{\prime}{\prime}}E$) The mine was begun to work soon after the inhabitants of this village had accidently discovered the outcrops in April 1908. It is one of the largest gold mines in Korea which produces 4,500 tons of crude ore a month. The geology in the area consists of granitic gneiss, banded gneiss, augen-gneiss, mica schist, limesilicate of Pre-Cambrian series and sedimentary rocks(sandstones & conglomerates) of Daedong series. Basic dikes intrude the former formations. The country rock of the ore deposit is a group of the metamorphic rocks mentioned above. Gold-silver bearing quartz vein contains small amounts of pyrite, chalcopyrite, arsenopyrite, galena and sphalerite in which gold and silver occur as native state. The vein strikes $N30^{\circ}{\sim}60^{\circ}E$ and dips $20^{\circ}{\sim}50^{\circ}S$ and the average width of the vein is estimated 1 to 1.5m. Average grade of ore is Au:6~8gr/t and Ag:5~6gr/t. The ore shoot continues from the outcrop to the depth of -1760ML with dip of $20{\sim}25^{\circ}$ and strike extension reaches to 400m at the depth of -1440 ML and to more or less 200m at below. Highgrade of ore vein was found at the lowest level of the ore shoot at the time of recent field survey at the end of August 1970. Its average grade was estimated as Au:20gr/t and its width 1~2.5M in average. A series of futher prospecting for other new ore shoot or parallel veins are urgent and crosscut prospecting along the horizontal level is strongly recommended.

  • PDF

Correction of a Wide Alveolar Cleft with Reverse L osteotomy and Liou Alveolar Distractor (역 L 형 절골술과 Liou 신연기를 이용한 넓은 치조열의 교정)

  • Lee, Myung Chul;Lew, Dae Hyun;Park, Beyoung Yun;Kwon, Soon Man
    • Archives of Plastic Surgery
    • /
    • v.36 no.4
    • /
    • pp.445-449
    • /
    • 2009
  • Purpose: A successful surgical treatment for a wide alveolar cleft with bone graft is difficult to achieve due to several factors such as the limitation of gingivoperiosteal flap, the presence of large scar tissues, and the poor blood circulation. To overcome these problems, alveolar distraction osteogenesis using Liou alveolar distraction device was applied. We analyzed the consequences of this surgical treatment. Method: Between 2006 January and 2007 August, we have conducted analysis on the methods and consequences of Liou alveolar distraction osteogenesis for 6 patients. The age of patients was 12 years and 6 months in average. The follow up period was 19 months in average. The Reverse L osteotomy followed by the placement of the Liou alveolar distraction device was performed. After serial distraction, the distractor was removed after 5 months of the process of osteogenesis, and the result was analyzed using the computed tomography and the x-ray films of the alveolar bone and the teeth. Results: The alveolar cleft with 12.5 mm in average width was filled with 8.5 mm of newly formed bone tissue in average width after 5 months of osteogenesis. Among the 6 cases, 5 required the additional bone graft and 1 case only required the gingivoperioplasty. The newly formed bone tissues did not show any signs of bone resorption. However, a considerable degree of teeth displacement was shown. Conclusion: For the alveolar cleft too wide to be reconstructed by a general bone graft, it is strongly recommended to perform the reverse L osteotomy of the cleft side with Liou alveolar distraction device to initiate the alveolar osteogenesis. However, the migrated teeth showed some degree of relapse, thus, the orthodontic treatment is essential following the distraction osteogenesis treatment.

Cone-beam CT analysis of patients with obstructive sleep apnea compared to normal controls

  • Buchanan, Allison;Cohen, Ruben;Looney, Stephen;Kalathingal, Sajitha;De Rossi, Scott
    • Imaging Science in Dentistry
    • /
    • v.46 no.1
    • /
    • pp.9-16
    • /
    • 2016
  • Purpose: To evaluate the upper airway dimensions of obstructive sleep apnea (OSA) and control subjects using a cone-beam computed tomography (CBCT) unit commonly applied in clinical practice in order to assess airway dimensions in the same fashion as that routinely employed in a clinical setting. Materials and Methods: This was a retrospective analysis utilizing existing CBCT scans to evaluate the dimensions of the upper airway in OSA and control subjects. The CBCT data of sixteen OSA and sixteen control subjects were compared. The average area, average volume, total volume, and total length of the upper airway were computed. Width and anterior-posterior (AP) measurements were obtained on the smallest axial slice. Results: OSA subjects had a significantly smaller average airway area, average airway volume, total airway volume, and mean airway width. OSA subjects had a significantly larger airway length measurement. The mean A-P distance was not significantly different between groups. Conclusion: OSA subjects have a smaller upper airway compared to controls with the exception of airway length. The lack of a significant difference in the mean A-P distance may indicate that patient position during imaging (upright vs. supine) can affect this measurement. Comparison of this study with a future prospective study design will allow for validation of these results.

Effect of slow forced eruption on the vertical levels of the interproximal bone and papilla and the width of the alveolar ridge

  • Kwon, Eun-Young;Lee, Ju-Youn;Choi, Jeomil
    • The korean journal of orthodontics
    • /
    • v.46 no.6
    • /
    • pp.379-385
    • /
    • 2016
  • Objective: Forced eruption has been proposed for the reconstruction of deficient bone and soft tissue. The aim of this study was to examine the changes in the alveolar ridge width and the vertical levels of the interproximal bone and papilla following forced eruption. Methods: Patients whose hopeless maxillary anterior teeth were expected to undergo severe bone resorption and soft tissue recession upon extraction were recruited. In addition, patients whose maxillary anterior teeth required forced eruption for restoration due to tooth fracture or dental caries were included. Before and after forced eruption, the interproximal bone height was measured by radiographic analysis, and changes in the alveolar ridge width and the interproximal papilla height were measured with an acrylic stent. Results: This prospective study demonstrated that the levels of the interproximal alveolar bone and papilla were significantly increased by 1.36 mm and 1.09 mm, respectively, in the vertical direction. However, the alveolar ridge width was significantly reduced by an average of 0.67 mm in the buccolingual direction. The changes in the level of the interproximal alveolar bone and papilla were positively correlated. Conclusions: Although the levels of the interproximal bone and papilla were significantly increased, the alveolar ridge width was significantly decreased following forced eruption. There was a modest positive and significant correlation between the changes in the height of the interproximal alveolar bone and the papilla. Based on our findings, modification of vertical forced eruption should be considered when augmentation of the alveolar ridge width is required.

Six Sigma based on Robust Design of Gripper for LCD Transfer System (LCD 이송장치의 그립퍼부 시그마 기반 강건설계)

  • Chung W.J.;Jung D.W.;Kim H.J.;Yoon Y.M.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.361-362
    • /
    • 2006
  • This paper presents the robust design of gripper part for a high-speed LCD (Liquid Crystal Display) transfer system. In this paper, the 1st DOE (Design of Experiment) is conducted to find out main-effect factors fur the design of gripper part. Thirty-six experiments are performed using $ANSYS^{(R)}$ and their results are statistically analyzed using $MINITAB^{(R)}$, which shows that the factors, i.e., First-width, Second-width, Rec-width, and thickness of gripper part, are more important than other factors. The main effect plots shows that the maximum deflection and mass of gripper part are minimized by increasing First-width, Second-width, Rec-width and thickness. The 2nd DOE is conducted to obtain RSM (Response Surface Method) equation. The CCD (Central Composite Design) technique with four factors is used. Optimum design is conducted using the RSM equation. Genetic algorithm is used for optimal design. Six sigma robust design is conducted to find out a guideline for control range of design parameter. To obtain six sigma level reliability, the standard deviations of design parameters are shown to be controlled within 5% of average design value.

  • PDF