• Title/Summary/Keyword: Average width

Search Result 1,187, Processing Time 0.027 seconds

Characteristics of Fluid Force Reduction of a Square Prism With a Small Triangular Prism (작은 삼각주에 의한 정방형주의 유체력 저감특성)

  • Ro, Ki-Deok
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.3
    • /
    • pp.243-247
    • /
    • 2015
  • The characteristics of the fluid force reduction of a square prism having a small triangular prism at the upstream side was investigated by measuring of lift and drag on the square prism The experimental parameters were the width ratios (H/B=0.2~0.6) of triangular prisms to the prism width and the gap ratios (G/B=0~3) between the square prism and the triangular prism. The drag reduction rate of the square prism was increased and then decreased with G/B in case of the same H/B, and was increased with H/B in case of the same G/B. The maximum drag reduction rate was represented by 78.5% at H/B=0.6 and G/B=1.5. The lift reduction rate of the square prism was hardly not affected by the width and gaps ratios, the average value was about 52.4%.

Experiments of flowfield of a square prism having a front vertical plate (정면에 수직 평판을 가진 정방형주의 유동장 특성실험)

  • Ro, Ki-Deok;Jo, Dong-Bae;Yoon, Young-Jun;Park, Seo-Jin
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.7
    • /
    • pp.900-908
    • /
    • 2014
  • The Characteristics of the flowfields of a square prism having a small vertical plate at the upstream side was investigated by measuring of fluid force on the square prism and by visualization of the flow fields using PIV. The experimental parameters were the width ratios(H/B=0.2~0.6) of vertical plates to the prism width and the gap ratios (G/B=0~3) between the prism and the vertical plate. The drag reduction rate of the square prism was increased with H/B in case of the same G/B, and was increased and then decreased with G/B in case of the same H/B. The lift reduction rate of the square prism was hardly not affected by the width and gaps ratios, the average value was about 48.1%. In case of a square prism having a small vertical plate, the stagnation regions were represented in the upstream and downstream sides of the square prism.

Relation between the Concentration of Hexagonal Boron Nitride Nano-Sheets Dispersed in Pure Water and Their Width and Height (초순수 용매 내 육방정 질화붕소 나노시트의 농도와 크기의 관계)

  • Cho, Dae-Hyun;Park, Miyoung;Ha, Seonghun
    • Tribology and Lubricants
    • /
    • v.35 no.6
    • /
    • pp.343-349
    • /
    • 2019
  • According to a report in 2011, hexagonal boron nitride demonstrated good solubility in pure water, even without surfactants or organic functionalization. Hexagonal boron nitride nanosheets are an effective lubricant additive, and their solubility in pure water has motivated lubrication engineers to utilize aqueous solutions containing these nanosheets as water-based lubricants. In this study, we measure the width and height of the hexagonal boron nitride nanosheets dispersed in pure water by using the Zetasizer and atomic force microscopy. Without surfactants or functionalization, aqueous solutions containing 0.10, 0.07, 0.05, and 0.01 wt% of hexagonal boron nitride nanosheets are synthesized via sonication-assisted hydrolysis. The Zetasizer provides only a one-dimensional size of approximately 410 nm, regardless of the concentration of the solution. Thus, it does not allow the estimation of the shape of the nanosheet. To acquire the three-dimensional size of the nanosheets, atomic force microscopy is employed. The aqueous solutions containing 0.10, 0.07, 0.05, and 0.01 wt% of the hexagonal boron nitride nanosheets show average values of 740, 450, 700, and 610 nm in width, and 37, 26, 33, and 32 nm in thickness, respectively. No significant trend is observed between the concentration of the solution and size of the nanosheets. Therefore, when preparing a water-based lubricant, it may be appropriate to adjust conditions such as ultrasonication time rather than the concentration.

A Study on Classification of Chinese Men's Body Types - Focused in Beijing and Shanghai -

  • Lim, Soon;Sohn, Hee-Soon;Kim, Jee-Yeon
    • Journal of Fashion Business
    • /
    • v.6 no.6
    • /
    • pp.78-88
    • /
    • 2002
  • The purpose of this study is to provide for some basic data useful to production of the apparels fit and measured well for the Chinese men. For this purpose, 389 men aged between 20 and 49 and living in Beijing and Shanghai, China were sampled to be measured for their constitutions. Then, their constitutions were classified and thereupon, according to the Men's Wear Specifications (GB/T 1335.1-1997), National Standards of People's Republic of China. The collected data were statistically processed using SAS 6.12 for technical statistical analysis, correlation analysis, factor analysis, group-wise analysis. The results of this study can be summarized as follows; 1. As a result of the factor analysis aiming to determine Chinese men's constitutional components, five components could be identified: constitutional obesity, lateral body size, longitudinal body size, shoulder and back width, and shoulder drooping. 2. As a result of classifying Chinese men's constitutions according to drop measurements, four types could be identified. Y type had the lowest obesity and the highest longitudinal body size. A type had a lower obesity and had an average longitudinal body size. B Type had the second highest obesity, the smallest longitudinal body size and shoulders/back width. C Type had the highest obesity, upper body length and shoulders/back width. 3. In terms of distribution, 'B' type (39.10%) of the sample, followed by 'A' type (29.26%), 'C' type (19.95%) and 'Y' type (11.70%). In all, the results of this study suggests that 'B' type represents the Chinese men in contrast with GB specifying that 'A' type represents the Chinese men. On the other hand, Beijing region was dominated most by 'B' type (37.06%), followed by 'A' type (28.82%), 'C' type (22.35%) and 'Y' type (11.76%), while Shanghai region was dominated most by 'B' type (41.13%), followed by 'A' type (31.21%), 'C' type (19.15%) and 'Y' type (8.51%).

Suggesting double-web I-shaped columns for omitting continuity plates in a box-shaped column

  • Saffari, Hamed;Hedayat, Amir A.;Goharrizi, Nasrin Soltani
    • Steel and Composite Structures
    • /
    • v.15 no.6
    • /
    • pp.585-603
    • /
    • 2013
  • Generally the required strength and stiffness of an I-shaped beam to the box-shaped column connection is achieved if continuity plates are welded to the column flanges from all sides. However, welding the forth edge of a continuity plate to the column flange may not be easily done and is normally accompanied by remarkable difficulties. This study was aimed to propose an alternative for box columns with continuity plates to diminish such problems. For this purpose a double-web I-shaped column was proposed. In this case the strength and rotational stiffness of the connection was provided by nearing the column webs to each other. Finite element studies on about 120 beam-column connections showed that the optimum proportion of the distance between two column webs and the width of the column flange (parameter ${\beta}$) was a function of the ratio of the beam flange width to the column flange width (parameter ${\alpha}$). Hence, based on the finite element results, an equation was proposed to estimate the optimum value of parameter ${\beta}$ in terms of parameter ${\alpha}$ to achieve the highest connection performance. Results also showed that the strength and ductility of post-Northridge connections of such columns are in average 12.5 % and 54% respectively higher than those of box-shaped columns with ordinary continuity plates. Therefore, a double-web I-shaped column of optimum arrangement might be a proper replacement for a box column with continuity plates when beams are rigidly attached to it.

A study of panoramic focal trough for the six-year-old child (6세 아동을 위한 파노라마방사선사진 상층의 연구)

  • Kim Sang-Yeon;Cho Hang-Moon;Han Jin-Woo;Lee Sul-Mi
    • Imaging Science in Dentistry
    • /
    • v.34 no.2
    • /
    • pp.63-67
    • /
    • 2004
  • Purpose: To make a focal trough (image layer) for an average maxillary dental arch of 6-year-old korean in panoramic radiography. Materials and Methods : Phantom for the maxillary dental arch was designed using intercanine width, intermolar width, tooth size, and interdental spacing to record the data of 6-year-old child. The characteristics of pre-corrected panoramic machine (for adult) was evaluated using the phantom, resolution test pattern for margin of the image layer, and metal ball for the center of the image layer. Panoramic image layer of the child was developed by means of decreasing the speed of film-cassette and positioning the phantom backwards, and then the characteristics of post-corrected panoramic machine (for child) were reevaluated. Results: At post-corrected panoramic image layer, beam projection angles at all interdental areas increased for about 2.6-3.8°, the position of the image layer was shifted toward the rotation center for about 2.5 mm at the deciduous central incisior area. The width of image layer decreased at all areas. Conclusion : Increased beam projection angle will reduce the disadvantage of tooth overlap, and the same form between the center of the image layer and dental arch will improve image resolution.

  • PDF

A Study on the Basic Bodice Pattern for the Fatty Body -The subject of middle-aged women- (비만체형을 위한 기본 Bodice 원형연구 -중년기 부인을 중심으로-)

  • 한애미
    • Journal of the Korean Home Economics Association
    • /
    • v.25 no.3
    • /
    • pp.15-26
    • /
    • 1987
  • The purpose of this study was to develop the pattern drafting method which would be suitable to their physical characteristics for the fatty body of 40∼55 aged Korean women who are more than 1.5 Rohrer's Index and 90㎝ bust girth. The study was composed as follows; 1. Body measurement and statistical analysis: One hundred and thirty women were measured on 29 items. Thirty-four items including 29 measured items and 5 calcutated items were analyzed statistically. 1) Mean, standard deviation, variance, maximum, minimum, range were computed. 2) Correlation coefficients between each items were computed. 2. Development of new bodice pattern drafting method: Measurement items necessary to draft new bodice pattern were bust girth, center back waist length, shoulder width, back width, chest and neck base girth. The new pattern was examined through three wearing tests for completion. 3. Evaluation of the new pattern drafting method: The new pattern was objectively evaluated by the sensory test. The sensory evaluation was applied to evaluate the new pattern for the fatty body women by comparint it with the conventional patterns. The results of sensory tests of the new pattern are as follows: 1) The composite reliability coefficient is 0.7698, and the reliability of sensory test shows high. 2) According to a statistical analysis of the result of the 23 items on the questionaire, all the items showed significant differences(α 0.01) between the two, with the new pattern having higher scores. The new pattern is better conventional pattern as the average mark of the former is 3.901 but that of latter is 2.926. The new pattern drafting method proved to be superior to the conventional one especially in the fitness at the center front neck point, shoulder point, side line, armscye depth, position of bust point, chest width line, under arm dart and the shoulder line.

  • PDF

Comparison of the 3D Digital Photogrammetry and Direct Anthropometry in Unilateral Cleft Lip Patients (일측성 구순열 환자에서 3차원 수치사진측량 스캔과 직접계측 방법의 비교)

  • Seok, Hyo Hyun;Kwon, Geun-Yong;Baek, Seung-Hak;Choi, Tae Hyun;Kim, Sukwha
    • Archives of Craniofacial Surgery
    • /
    • v.14 no.1
    • /
    • pp.11-15
    • /
    • 2013
  • Background: In cleft lip patients, the necessity of a thorough preoperative analysis of facial deformities before reconstruction is unquestioned. The surgical plan of cleft lip patient is based on the information gained from our preoperative anthropometric evaluation. A variety of commercially available three-dimensional (3D) surface imaging systems are currently introduced to us in plastic surgery for these use. However, few studies have been published on the soft tissue morphology of unrepaired cleft infants described by these 3D surface imaging systems. Methods: The purpose of this study is to determine the accuracy of facial anthropometric measurements obtained through digital 3D photogrammetry and to compare with direct anthropometry for measurement in unilateral cleft lip patients. We compared our patients with three measurements of dimension made on both sides: heminasal width, labial height, and transverse lip length. Results: The preoperative measurements were not significantly different in both side of labial height and left side of heminasal width. Statistically significant differences were found on both side of transverse lip length and right side of heminasal width. Although the half of preoperative measurements were significantly different, trends of results showed average results were comparable. Conclusion: This is the first study in Korea to simultaneously compare digital 3D photogrammetry with traditional direct anthropometry in unilateral cleft lip patients. We desire this study could contribute the methodological choice of the many researchers for proper surgical planning in cleft lip reconstruction field.

Six Sigma Robust Design of Composite Hand for LCD Glass Transfer Robot (LCD 유리 이송용 복합재료 로봇 핸드의 식스 시그마 강건설계)

  • Nam Hyunwook
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.3 s.234
    • /
    • pp.455-461
    • /
    • 2005
  • This research studied robust design of composite hand for LTR (LCD glass Transfer Robot). $1^{st}$ DOE (Design of Experiment) was conducted to find out vital few Xs. 108 experiments were performed and their results were statistically analyzed. Pareto chart analysis shows that the geometric parameters (height and width of composite beam) are more important than material parameters $(E_{1},\;E_{2})$ or stacking sequence angle. Also, the stacking sequence of mid-layer is more important than that of outer-layer. The main effect plots shows that the maximum deflection of LTR hand is minimized with increasing height, width of beam and layer thickness. $2^{nd}$ DOE was conducted to obtain RSM (Response Surface Method) equation. 25 experiments were conducted. The CCD (Central Composite Design) technique with four factors was used. The coefficient of determination $(R^{2})$ for the calculated RSM equation was 0.989. Optimum design was conducted using the RSM equation. Multi-island genetic algorithm was used to optimum design. Optimum values for beam height, beam width, layer thickness and beam length were 24.9mm, 186.6mnL 0.15mm and 2402.4mm respectively. An approximate value of 0.77mm in deflection was expected to be a maximum under the optimum conditions. Six sigma robust design was conducted to find out guideline for control range of design parameter. To acquire six sigma level reliability, the standard deviation of design parameter should be con trolled within $2{\%}$ of average design value

Development of Jacket Bodice Pattern for Elderly Women Using 3D Pattern Design System (3D 패턴 디자인 시스템에 의한 노년 여성의 재킷바디스패턴 연구)

  • Suh, Chu-Yeon
    • Fashion & Textile Research Journal
    • /
    • v.8 no.5
    • /
    • pp.552-561
    • /
    • 2006
  • This study was conducted to suggest an appropriate jacket bodice pattern for elderly women by comparing the developed pattern with existing ready-made jacket pattern. The developed jacket bodice pattern was produced from the basic sloper in which elderly women's somatotype was fully reflected, by using the newly developed 3D pattern design system. Subjects were 6 elderly women aged from 60 to 69 who have average somatotype in their age group. This study carried out pattern analysis and self-sensory test with three ready-made jackets(national brands) and suggested a developed jacket pattern based on the results. According to the self sensory test results of ready-made jacket, wearing fitness among brands was significantly different even though those brands were same B91 size. The results of ready-made jackets' pattern analysis, size differences among patterns have influenced wearing fitness. The basic numerical formula for the jacket pattern considered elderly women's somatotype were as follows; $B/4+2{\pm}0.2{\sim}0.5$(difference of front and back), $W/4+2{\pm}0.2{\sim}0.5$(difference of front and back), H/4+2~7(ease amount), armhole depth B/4, chest width B/6+1, back width B/6+3 and back neck width B/12+0.5. According to the results of the developed jacket's appearance evaluation, it earned higher scores in silhouette and ease amount, confirming that the developed jacket is appropriate for the elderly women. Also, in the evaluation on space length, the developed jacket pattern was evaluated to allow proper space length in all around of measurement parts.