• 제목/요약/키워드: Average vertical force

검색결과 70건 처리시간 0.023초

승마 속보 시 미숙련자에게 적용한 하지장 비율 74.04% 등자길이 피팅의 기승자세 효과 (The Effects of the Stirrup Length Fitted to the Rider's Lower Limb Length on the Riding Posture for Less Skilled Riders during Trot in Equestrian)

  • 현승현;류재청
    • 한국운동역학회지
    • /
    • 제25권3호
    • /
    • pp.335-342
    • /
    • 2015
  • Objective : The purposes of this study was to analyze the effects of the stirrup length fitted to the rider's lower limb length and it's impact on less skilled riders during trot in equestrian events. Methods : Participants selected as subjects consisted of less skilled riders(n=5, mean age: $40.02{\pm}10.75yrs$, mean heights: $169.77{\pm}2.08cm$, mean body weights: $67.65{\pm}7.76kg$, lower limb lengths: $97.26{\pm}2.35cm$, mean horse heights: $164.00{\pm}5.74cm$ with 2 type of stirrups lengths(lower limb ratio 74.04%, and 79.18%) during trot. The variables analyzed consisted of the displacement for Y axis and Z axis(head, and center of mass[COM]) with asymmetric index, trunk front-rear angle(consistency index), lower limb joint(Right hip, knee, and ankle), and average vertical forces of horse rider during 1 stride in trot. The 4 camcorder(HDR-HC7/HDV 1080i, Spony Corp, Japan) was used to capture horse riding motion at a rate of 60 frames/sec. Raw data was collected from Kwon3D XP motion analysis package ver 4.0 program(Visol, Korea) during trot. Results : The movements and asymmetric index didn't show significant difference at head and COM, Also, 74.04% stirrups lengths in trunk tilting angle showed significant difference with higher consistency than that of 79.18% stirrups lengths. Hip and knee joint angle showed significant difference with more extended posture than that of 74.04% stirrups lengths during trot. Ankle angle of 79.18% stirrups length showed more plantarflexion than that of 74.04% stirrups lengths. Average vertical force of rider showed significant difference with higher force at 79.18% stirrups lengths than that of 74.04% stirrups lengths during stance phase. Conclusion : When considering the above, 74.04% stirrups length could be effective in impulse reduction with consistent posture in rather less skilled horse riders.

거리에 따른 수직 충돌 제트의 표면 평균압 측정 (Measurement of the Average Surface Pressure by a Vertical Impinging Jet for the Different Distances)

  • 정우원;이계한;장안식;박경열;전경진
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.181-182
    • /
    • 2006
  • When a water jet is injected on the body surface, the pressure and shear stress on the surface are important physical parameters in determining the body surface wash out and physical stimulus. We used the force plate in order to measure the surface average pressure for different nozzle types and distances between a nozzle and a plate. We used the nozzles with a hole dimeter of 1.8, 2.9, 3.2mm, and the shower heads with 10 holes (hole diameter, 1mm) and 20 holes (hole diameter, 1mm). The distances between a nozzle and a plate was 10, 20, 30, 40cm. The results showed that the surface forces were not affected by the distances between a nozzle and a plate. Further numerical studies will be performed to predict wall shear stress based on the measured pressure data.

  • PDF

각도별 런닝 턴 시 발의 효과에 관한 동역학적 분석 (Dynamics of Angular Running Turns in Foot Effectiveness)

  • 신성휴;박현철
    • 한국운동역학회지
    • /
    • 제19권4호
    • /
    • pp.663-669
    • /
    • 2009
  • 본 연구의 목적은 런닝 턴 동작시 많은 정확한 턴을 위한 방법으로 발의 움직임을 역학적으로 분석하기 위함이다. 런닝 턴 동작에 대한 많은 역학적인 요인들 중 정확한 턴을 위해서는 감속이 발생되고 이런 감속은 진행하고자 하는 방향으로 턴을 할 수 있게 해준다. 턴이 시작되는 시점인 발의 회전각과 이로 발생되는 몸통의 각을 3차원 영상분석과 지면반력 분석을 하였다. 따라서, 여러 매개변수들 중 수직축(z축)에서 발의 총 회전각($\theta_f$)/몸통 총 회전각($\theta_d$)= 발의 효과($\varepsilon$)로 단순화 시켜 간단한 방정식을 만들어서 설명했으며, 자료 산출을 위해 평균 속력 4.5m/s에서 진행 방향 $0^{\circ}$, $30^{\circ}$, $60^{\circ}$ 턴에 대한 분석을 통해 턴의 각이 커지면 커질수록 입각기 시간, 발 변위, 좌 우힘이 증가했음을 알 수 있었다.

압축하중을 받는 압전 작동기로 구동하는 곤충모방 날갯짓 기구의 특성 (Characteristic of an insect-mimicking flapping device actuated by a piezoceramic actuator)

  • 박훈철;구옌쿠옥비엣;변도영;구남서;윤광준
    • 한국항공우주학회지
    • /
    • 제36권11호
    • /
    • pp.1063-1071
    • /
    • 2008
  • 단일층 압전작동기에 적절한 압축하중을 가하면, 압전세라믹 층에 가해지는 압축 응력에 의한 재료비선형적 특성과 기계적 좌굴현상에 의하여 작동 변위와 작동력이 동시에 향상된다. 본 논문에서는 날갯짓 기구를 압축하중을 받는 단일층 압전 작동기로 구동하는 경우, 날갯짓 각도와 공기력에 어떠한 영향이 발생하는가를 조사하였다. 또한 날개 형상과 수동 날갯 회전 각도가 공기력 발생에 미치는 영향도 실험적으로 조사하였다. 인공 날개를 2차원으로 가정한 전산유체해석을 통하여 얻은 평균 수직력이, 실험으로 얻은 값과 잘 일치함을 확인하였다.

안모유형에 따른 교정치료 (ORTHODONTIC TREATMENT RELATED TO FACIAL PATTERNS)

  • 황충주
    • 대한치과교정학회지
    • /
    • 제18권2호
    • /
    • pp.475-488
    • /
    • 1988
  • Certain malocclusion are associated with specific "facial type," and it is important for the clinician to classify the common facial characteristic of each patient. Because the reaction to treatment mechanics and the stability of the denture is depended upon the analysis of the facial pattern. Basically, there are 3 district facial types or patterns under which almost all malocclusion can be classified. 1. mesofacial is the most average growth. 2. brachyfacial which is a horizontal growth pattern has a week muscle, with dental arch, deep bite. 3. dolichofacial which is a vertical growth pattern has a strong muscle, narrow dental arch, open bite. Brachyfacial pattern show a resistant to mandibular rotation during treatment can accept a more protrusive denture and are prominantly nonextraction, whereas dolichofacial patterns tend to open during treatment require a more retracted denture in order to assure post-treatment stability. Brachyfacial pattern would better treat to use extrusive force system, whereas dolichofacial pattern treat to use intrusive force system with head gear and intermaxillary elastics.

  • PDF

얇은 고무막 형태의 압력가변 연마헤드를 이용한 웨이퍼 평탄도 개선 방법에 관한 연구 (Planarization Uniformity Improvement by a Variable Pressure Type of the Polishing Head with the Thin Rubber Sheet)

  • 이호철
    • 한국정밀공학회지
    • /
    • 제22권4호
    • /
    • pp.44-51
    • /
    • 2005
  • In this paper, a new polishing head with the variable pressure structure was studied to improve the planarization uniformity of the conventional template-metal head. Metal surface waviness and slurry distribution on the pad have been known to affect the polishing uniformity even in the synchronized quill and platen velocities. A polishing head with silicon rubber sheet was used to get a curved pressure distribution. In the experiment, the vertical deflection behavior on the pad was characterized with back pressure in the air chamber. Quill force increased linearly with backpressure. However, backpressure under a quill force made the upward movements of the quill. In the wafer polishing experiments, polishing rate and polishing thickness distribution were severely changed with backpressure. The best uniformity was observed with the standard deviation off.5% level of average polishing removal 215nm at backpressure 12.1kPa.

아동의 복합운동이 착지 시 하지 손상요인에 미치는 영향 (Effects of Combined Exercise on Injury Risk Factors of Lower Extremity during Landing)

  • 하성희;류시현;김주년;길호종;류지선;윤석훈;박상균
    • 한국운동역학회지
    • /
    • 제24권2호
    • /
    • pp.173-180
    • /
    • 2014
  • The purpose of this study was to investigate the effect of combined exercise on injury risk factors of lower extremity during landing. Ten sports talented athletes participated in this study. Sports talented athletes participated in a combined exercise (sports talented exercise, coordination) for 16 weeks. A three-dimensional motion analysis was performed using eight infrared cameras (sampling rate of 100 Hz), one force plate, and electromyography system (sampling rate of 1000 Hz) during landing. Kinetic, and kinematics analysis including average impulsive force, angle of lower extremity, vertical stiffness, onset of muscle activation were calculated by Matlab2009a software. Paired t-test was performed at alpha=.05. The average impulsive force in landing phase was not statistically significant (t=-.748, p=.474). The hip joint angle was more decreased in post test compared to pre test (E1: t=2.682, p=.025, E2: t=5.609, p=.000, E3: t=2.538, p=.032). The knee joint (E1: t=-.343, p=.739, E2: t=1.319, p=.220, E3: t=.589, p=.570) and ankle joint (E1: t=.081, p=.937, E2: t=.784, p=.453, E3: t=.392, p=.704) angle were tended to decrease after combined exercise. The vertical stiffness was tended to decrease after combined exercise (t=1.972, p=.080). Onset of quadriceps femoris (t=.698, p=.503) and medial gastocnemius (t=1.858, p=.096) were tended to be faster than biceps femoris (t=-.333, p=.747) after combined exercise. Although thses findings were not statistically significant except on a hip joint angle, risk factors of lower extremity such as joint angle, vertical stiffness and onset of quadriceps femoris, medial gastrocnemius were positively changed after the combined exercise but an additional training for improved onset of biceps femoris would be required in the future.

심한 교모증 환자의 완전 구강 회복 (Full Mouth Rehabilitation in Severely Worn Dentition)

  • 정재현;최민호;박영록;김창헌;강동완
    • 구강회복응용과학지
    • /
    • 제19권3호
    • /
    • pp.247-256
    • /
    • 2003
  • The patient had bruxism and epilepsy tendency. Inadequate or unstable posterior support was identified due to severe anterior attrition and decreased occlusal vertical dimension. Prematurities of posterior occlusal and wear facets increased the function of anterior teeth, resulting in severe wear. Wear facets displayed sharply defined peripheries, which are matched on articulated diagnostic casts. Also the patient showed C III malocclusion tendency, and lost some facial contour with drooping corners on the mouth. In this case, the alteration of OVD (Occlusal Vertical Dimention) may provide a biologically compatible adjunct to the treatment such as dentofacial esthetics, improved visual proportion in facial heightand mechanical solutions to the force-management of the masticatory system. The patient requires extensive restorative treatment to regain appropriate function, esthetics and comfort. According to the report by Farhad Fays, the average vertical distance from the maxillary to the mandibular mucolabial reflection in the region of the central incisors is approximately 34mm. However, the vertical distance of this patient was found to be 32mm, which was necessary to add gauge 20-sheets to apply vertical dimension. A removable occlusal overlay splint, which restores OVD to the estimated optimalposition, is the general first trial. The patient was observed periodically for 6 weeks, while appropriate adjustments were made vertical dimension to function. When patient felt comfortable with the splint, the teeth were prepared, and provisional restorations are placed for 3 months. The provisional restoration was fabricated by a diagnostic wax-up. When the patient felt comfortable with the provisional restoration, the final restoration mimics OVD, function, and esthetics that have been developed in the treatment restorations. Restoration of the extremely worn dentition presents a substantial challenge to thedentists. Therefore, careful evaluation of the etiology, history, and factors associated with occlusal vertical dimension should be preceded prior to the appropriate treatment planning.

국내 Raise Boring Machine의 굴착능력에 관한 연구 (Study on the Workability of Raise Boring Machine in Korea)

  • 이석원;조만섭;배규진
    • 터널과지하공간
    • /
    • 제13권3호
    • /
    • pp.196-206
    • /
    • 2003
  • 본 연구에서는 Raise Boring Machine(RBM의 가동율, 관입율, 굴진율과 같은 굴착능력을 조사하기 위하여 직경 3.05 m와 총 연장 98 m의 수직구를 RBM을 이용하여 시험시공 하였다. 이와 함께 국내 양수발전소, 도로터널, 석탄광업소 등에서 RBM으로 시공되었던 4개의 수직구 시공현장으로부터 시공자료를 수집하여 분석을 수행하였다. 연구결과, 주간 평균 굴진장은 약 19.3 m로 분석되었고, 평균 가동율은 약 54.3%011서 75.1 %사이에 분포하는 것으로 나타나, 이는 TBM 시공실적과 비교하여 볼 때 매우 높은 가동율을 보이고 있다. Bit force와 RPM은 (+)의 직선적인 상관관계로 나타났으며 이는 굴착효율에 따라 작업자의 판단에 기인한 결과로 추정된다. 순관입율과의 관계에서는 RBM작업의 bit force와 RPM 및 수직구 심도가 증가함에 따라 순관입율이 저하되는(-)의 상관관계를 나타내었다. 본 연구결과는 수직구 설계 및 RBM장비 선정에 필요한 정보를 줄 수 있을 것으로 사료된다.

탄소나노튜브 인솔 착용에 따른 드롭 착지 동작의 생체역학적 분석 (Biomechanical Analysis of Wearing Carbon Nanotube-Based Insole during Drop Landing)

  • 채원식;정재후;이행섭
    • 한국운동역학회지
    • /
    • 제22권4호
    • /
    • pp.429-435
    • /
    • 2012
  • The purpose of this study was to determine the biomechanical effect of wearing carbon nanotube-based insole on cushioning and muscle tuning during drop landing. Twenty male university students(age: $21.2{\pm}1.5yrs$, height: $175.4{\pm}4.7cm$, weight: $70.2{\pm}5.8kg$) who have no musculoskeletal disorder were recruited as the subjects. Average axial strain, average shear strain, inversion angle, linear velocity, angular velocity, vertical GRF and loading rate were determined for each trial. For each dependent variable, a one-way analysis of variance(ANOVA) with repeated measures was performed to test if significant difference existed among different three conditions(p<.05). The results showed that Average axial strain of line 4 was significantly less in CNT compared with EVA and PU during IP phase. The average shear strain was less in CNT compared with EVA and PU during other phases. The inversion angle was increased in CNT compared with EVA and PU during all phase. In linear velocity, angular velocity, vertical GRF and loading rate, there were no significant difference between the three groups. This result seems that fine particle of carbon nanotube couldn't make geometric form which can absolve impact force by increasing density through eliminating voids of forms. Thus, searching for methods that keep voids of forms may play a pivotal role in developing of insole. This has led to suggestions of the need for further biomechanical analysis to these factors.