• Title/Summary/Keyword: Average intensity

검색결과 1,169건 처리시간 0.03초

야간 고등학교의 환경위생학적 조사 -조명을 중심으로- (The Study on Envronmental Sanitation for Night High School. -Illuminate-)

  • 김난천;오석흔
    • 한국환경보건학회지
    • /
    • 제5권1호
    • /
    • pp.40-45
    • /
    • 1978
  • We have selected 36 schools of a total of night high schools for boys and girls in seoul and measured intensity of illumination of the classroom, The corridors and the stairs that students study and live, with priority given to an illumination, a primary factor of environmental sanitation of school following is the result. 1. The maximum average intensity of illumination of the classroom is 93.2 Lux, and the minimum average intensity of illumination 39.5 Lux. Mean$\pm$S, is 59.03$\pm$22.8 Lux 2. The maximum average intensity of illumination of the corridor is 39.2 Lux, and the minimum average intensity of illumination 11.1 Lux. 3. The maximum average intensity of illumination of the stair is 11.58 Lux, and the minimum average intensity, of illumination 4.92 Lux, mean$\pm$S.D is 7.88$\pm$10.0Lux. 4. Schools with tile illumination facilities more than 50 Lux are 63.8% and less than 50 Lux are 36.2%. 5. Schools with 9-11 facilities of a source of light per classroom by a fluorescent lamp are the most as 30.50%. 6. As for the corridor, schools with the illumination equipment less than 10 Lux are 27.8%, are more than 10 Lux 72.2% 7. As for the stairs schools with the illumination equipment less than 10 Lux are 77.8%, and more than 10 Lux 10 Lux 22.2%.

  • PDF

하수관거 및 토구에서 발생하는 유황계 화합물 악취특성 (Odor Characteristics of Malodorous Sulfur-containing Gas Emitted from a Sewer and Its Outlets)

  • 박상진;권수열
    • 한국환경보건학회지
    • /
    • 제40권6호
    • /
    • pp.477-483
    • /
    • 2014
  • Objectives: This study was carried out to investigate the characteristics of odors emitted from sewage in a sanitary sewer and its outlets. Methods: The concentration of mal-odorous sulfur was analyzed by gas chromatograph, and odor intensity was estimated by an on-site sensory test. Odor intensity calculated from instrumental analysis results was compared with odor intensity observed at field. Results: As a results, the concentration of $H_2S$ ranged from 2.4 ppb to 5,889 ppb (average 703 ppb), while $CH_3SH$, $(CH_3)_2S$, and $(CH_3)_2S_2$ showed from 10 ppb to 554 ppb (average 119 ppb) and from 20 ppb to 332 ppb (average 70 ppb) and from 2.7 ppb to 8.1 ppb (average 5 ppb) individually. Average odor intensity observed in the field was degree three. Odor intensity calculated from sulfur compound concentration was confirmed as similar to the observed odor intensity because the coefficient of variance between the observed and the calculated intensities was less than one. Conclusion: It was expected that the results of this study will be helpful to design a deodorizing device to reduce odor emissions from sewerage facilities in the future.

SCM415강을 이용한 경도가공 특성 (Hardness Machining Characteristics using the SCM415 Still)

  • 신미정;김인수;김진수;김정화;김명규
    • 한국기계가공학회지
    • /
    • 제16권2호
    • /
    • pp.44-49
    • /
    • 2017
  • In this study, the cutting conditions of moving speed, number of main axial revolutions, etc. are changed for the chrome molybdenum steel (SCM415) material and carbide ball end mill tool to study the changes for processing intensity in the cutting process. The results that confirm the intensity of the measured value of the specimen for SCM415 display the intensity with an average 1.0667 HrC. After the fact cutter, it was able to confirm the average intensity of 8.3815 HrC. In addition, the intensity value after image processing may determine the average intensity survey value of 5.8690 HrC and the different intensity values with image processing after face cutting are shown for an average of ${\pm}2.5125HrC$. The different value of intensity with the specimen and image processing is confirmed for an average of 4.8024 HrC. The results of comparing the intensity following the number of main axial revolutions and moving speed show that the intensity is highest for 3,000 rpm and F200, and lowest for 4,000 rpm and F200.

A Background Initialization for Video Surveillance

  • Lim Kang Mo;Lee Se Yeun;Shin Chang Hoon;Kim Yoon Ho;Lee Joo Shin
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2004년도 학술대회지
    • /
    • pp.810-813
    • /
    • 2004
  • In this paper, a background initialization for video surveillance proposed. The proposed algorithm is that the background images are sampled n frames during ${\Delta}t$ All Sampling frames are divided by $M{\times}N$ size block every frame. Average values of pixels for same location block of the sampling frames during ${\Delta}t$t are taken. then the maximum intensity $\alpha$ and the minimun intensity $\beta$ is obtained, respecticely. The intial by $M{\times}N$ size block, then average intensity $\eta$ of pixels for the block is obtained. If the average intensity $\eta$ is out of the initial range of the background image, it is decided the moving object image, and if the average intensity $\eta$ is included in the initial range of the background image. it is decided the background image. To examine the propriety of the proposed algorithm in this paper, the accuracy and robustness evaluation results for human and car in the indoor and outdoor enviroment. the error rate of the proposed method is less than the existing methods and the extraction rate of the proposed method is better than the existing methods.

  • PDF

치과 진료실의 조명에 관한 실태 조사연구 (A STUDY ON THE ILLUMINATION OF DENTAL CLINIC)

  • 최종인;김유리;동진근
    • 대한치과보철학회지
    • /
    • 제44권4호
    • /
    • pp.374-382
    • /
    • 2006
  • Purpose: This study was designed to investigate the present conditions of illumination techniques in dental clinics in order to contribute improvement of operating environment. This study also aimed exploring qualitative and quantitative luminous intensity required for color temperature in dental clinic illumination, which was a critical part of esthetic dentistry. Materials and methods: A total of forty-eight local dental clinics were selected for sampling a) luminous intensity, and b) color temperature. The author measured the luminous intensity and the color temperature with lux meter and color meter respectively between 12pm and 2pm. The dental unit chair placed in the general operation positions were kept the distance 60 cm then all dental units were measured three times and averaged. The author measured the luminous intensity and color temperature with both common dental operating light and then without operating light in different office environments. The study was conducted under three conditions: 1 artificial illumination in clear day light 2. artificial illumination in cloudy day light, and 3. artificial illumination alone. Results : The results obtained were as follows. 1. The average luminous intensity in dental clinic lighting was 425 lux which was not sufficient to produce the optimal shade of the patient's teeth. Furthermore, the average luminous intensity even in full operating lighting was 9532 lux which fell short of the required level of 10,000 lux. 2. The average color temperature of all dental clinics surveyed was 5169 K which met the optimal range. However, only 33.3% fell in the correct region between 5,000-5,500 K as 25% were over 5,500 K and 41.6% were below 5,000 K. As a result, 66.7% were under insufficient color temperature conditions. 3. The dental unit chair placed next to a window, hence exposure to natural lighting, had significantly higher luminous intensity and color temperature compared to the dental unit chair which didn't have a window or natural lighting. 4. The data analysis revealed that only 6.3% of the dental clinic were met the standard of the average luminous intensity and color temperature.

Trend analysis of rainfall characteristics and its impact on stormwater runoff quality from urban and agricultural catchment

  • Salim, Imran;Paule-Mercado, Ma. Cristina;Sajjad, Raja Umer;Memon, Sheeraz Ahmed;Lee, Bum-Yeon;Sukhbaatar, Chinzorig;Lee, Chang-Hee
    • Membrane and Water Treatment
    • /
    • 제10권1호
    • /
    • pp.45-55
    • /
    • 2019
  • Climate change has significantly affected the rainfall characteristics which can influence the pollutant build-up and wash-off patterns from the catchment. Therefore, this study explored the influence of varying rainfall characteristics on urban and agricultural runoff pollutant export using statistical approaches. For this purpose, Mann-Kendall and Pettitt's test were applied to detect the trend and breakpoint in rainfall characteristics time series. In addition, double mass curve and correlation analysis were used to drive the relationship between rainfall-runoff and pollutant exports from both catchments. The results indicate a significant decreased in total rainfall and average rainfall intensity, while a significant increased trend for antecedents dry days and total storm duration over the study periods. The breakpoint was determined to be 2013 which shows remarkable trend shifts for total rainfall, average rainfall intensity and antecedents dry days except total duration. Double mass curve exhibited a straight line with significant rainfall-runoff relationship indicates a climate change effect on both sites. Overall, higher pollutant exports were observed at both sites during the baseline period as compared to change periods. In agricultural site, most of the pollutants exhibited significant (p< 0.05) association with total rainfall, average rainfall intensity and total storm duration. In contrast, pollutants from urban site significantly correlated with antecedent dry days and average rainfall intensity. Thus, total rainfall, average rainfall intensity and total duration were the significant factors for the agricultural catchment while, antecedents dry days and average rainfall intensity were key factors in build-up and wash-off from the urban catchment.

강우 강도에 따른 일반국도 지방부 도로의 평균속도 변화 분석 (Analysis of Provincial road in National Highway Average Speed Variation According to Rainfall Intensity)

  • 김태운;오주삼
    • 한국콘텐츠학회논문지
    • /
    • 제15권4호
    • /
    • pp.510-518
    • /
    • 2015
  • 기상조건이 교통 상황에 미치는 영향은 이미 알려진 사실이나 관련 연구는 부족한 실정이다. 이에 본 연구에서는 일반국도 지방부 도로에서 강우 수준에 따른 속도 변화를 분석하였다. 분석결과 강우 시 평균속도는 3.2% 감소하였고 교통량이 방향별로 200대/시 이하인 경우 최대 8.8% 감소하는 것으로 분석되었다. 이는 지방부 도로의 경우 자유 교통류 상황에서의 속도가 상대적으로 크게 감소했기 때문으로 판단된다. 또한 속도-교통량 그래프를 활용하여 강우 시 속도 감소 모형을 추정하고 통계 검증을 수행하였다. 추정된 모형은 강우 수준이 높을수록 기울기가 완만해졌으며, 이는 자유 교통류 상황에서의 속도가 상대적으로 크게 감소한 결과이다.

R&D Scoreboard에 의한 연구개발투자와 성과의 연관성 분석

  • 조성표;이연희;박선영;배정희
    • 기술혁신연구
    • /
    • 제10권1호
    • /
    • pp.98-123
    • /
    • 2002
  • This study develops a Korean R&D Scoreboard which has originated from the R&D Scoreboard in United Kingdom. The Scoreboard contains details of the R&D investment, sales, growth, profits and employee numbers for Korean companies which are extracted from company annual reports and key ratios calculated, with some movements over time. Companies are classified by the Korea Standard Industrial Classification. The Scoreboard contains 190 companies which consist of 100 largest companies and 30 middle-or small-sized firms listed in Korea Stock Exchange (KSE), and 30 ventures and 30 other firms listed in KOSDAQ. The overall company R&D intensity (R&D as a percentage of sales) is 2.1% compared to the international average of 4.2%. Korea has an unusually large R&D percentage of sales in IT hardware (4.9%) and telecommunication (3.7%). R&D intensity is positively correlated with company performance measures such as profitability, sales growth, productivity and market value. For largest companies listed in KSE and ventures listed in KOSDAQ, the ratio of operating profit to sales is greater for high R&D intensity companies. Sales growth is in proportion to R&D intensity for all companies. Plots of value added per employee or sales per employee vs R&D per employee rise together for the sectors studied, especially for the chemical sectors and automobile sectors, demonstrating a correlation with productivity. The average market value of high R&D companies in the KSE has risen more than 1.6 times that of the KOSPI 200 index. Given the correlation between R&D intensity and company performance and given that R&D is a smaller percentage of surplus (profits plus R&D) than international level (both overall and in several sectors), the challenges facing Korean companies are to maintain the leading position in IT hardware and telecommunication, and to increase the intensity of R&D in many medium-intensive R&D sectors where Korea has an average intensity well below international or US levels.

  • PDF

강우 강도에 따른 일반국도 지방부 도로의 교통량 변동 특성 (Provincial Road in National Highway Traffic Volume Variation According to Rainfall Intensity)

  • 김태운;오주삼
    • 한국콘텐츠학회논문지
    • /
    • 제15권3호
    • /
    • pp.406-414
    • /
    • 2015
  • 기존 교통량 관련 연구는 기상이 양호한 상태에서 진행하였거나 기상에 대한 영향을 제외한 경우가 대부분이다. 이에 본 연구에서는 강우 강도 따른 일반국도 지방부 지역에서 교통량 변동 특성 및 강우 보정계수를 제시하였다. 일반국도 상시 교통량 조사지점과 자동기상관측 장비 지점을 매칭한 후 지방부 도로에 설치된 256 지점을 선정하여 분석하였다. 평균 일교통량(ADT: Average Daily Traffic) 및 강우 보정계수의 분석결과 평일의 경우 업무통행으로 인하여 강우의 영향을 적게 받으며, 비평일의 경우 여가통행으로 강우의 영향을 상대적으로 많이 받는 것으로 나타났다. 강우 보정계수를 적용하여 연평균 일교통량(AADT: Annual Average Daily Traffic) 추정 시 오차율이 줄어드는 것으로 분석되어 AADT 추정 시 강우에 대한 고려가 필요하다. 강우는 평균 일교통량을 감소시키는 요인으로 작용함에 따라 도로의 설계 및 운영을 위해 강우 강도를 고려한 지속적인 연구가 필요하다.

Efficient methods for integrating weight function: a comparative analysis

  • Dubey, Gaurav;Kumar, Shailendra
    • Structural Engineering and Mechanics
    • /
    • 제55권4호
    • /
    • pp.885-900
    • /
    • 2015
  • This paper introduces Romberg-Richardson's method as one of the numerical integration tools for computation of stress intensity factor in a pre-cracked specimen subjected to a complex stress field across the crack faces. Also, the computation of stress intensity factor for various stress fields using existing three methods: average stress over interval method, piecewise linear stress method, piecewise quadratic method are modified by using Richardson extrapolation method. The direct integration method is used as reference for constant and linear stress distribution across the crack faces while Gauss-Chebyshev method is used as reference for nonlinear distribution of stress across the crack faces in order to obtain the stress intensity factor. It is found that modified methods (average stress over intervals-Richardson method, piecewise linear stress-Richardson method, piecewise quadratic-Richardson method) yield more accurate results after a few numbers of iterations than those obtained using these methods in their original form. Romberg-Richardson's method is proven to be more efficient and accurate than Gauss-Chebyshev method for complex stress field.