• Title/Summary/Keyword: Average Volume Method

Search Result 535, Processing Time 0.023 seconds

A Simulation Study on the Marine Traffic Congestion in Pusan Port (부산항 해상교통 혼잡도 평가에 관한 연구)

  • 여기태;이홍걸
    • Journal of Korean Port Research
    • /
    • v.12 no.2
    • /
    • pp.177-194
    • /
    • 1998
  • In Pusan port, the studies which analyze container cargo volumes by using forecasting methods and research about container logistics system, etc., have been continuously carried out. But, in Pusan port, the study on an evaluation of traffic congestion has been scarcely performed until now. Especially, when changing and extending a berth, or constructing a new port, it is very important to examine this field. And it should be considered. Thus, this paper aims to analyze the effect of ship traffic condition in the year 2011, to evaluate marine traffic congestion according to changing ship traffic volumes in Pusan port. To analyze it, we examined the results by simulation method.

  • PDF

Developing a Method for Detecting the Asian dust event Among High $PM_{10}$ events Using Aerodynamic Particle Sizer (APS) (Aerodynamic Particle Sizer (APS)를 이용한 고농도 $PM_{10}$ 사례 중 황사 판별기법 개발)

  • Lee, Young-Gon;Cho, Chun-Ho;Kim, Myoung-Soo
    • Atmosphere
    • /
    • v.18 no.1
    • /
    • pp.25-32
    • /
    • 2008
  • Log normalized volume size distribution (dV/dlog$D_p$) with 52 size ranges from 0.5 to $20.0{\mu}m$ was measured for the cases of high $PM_{10}$ mass concentration (> $200{\mu}gm^{-3}$) using the Aerodynamic Particle Sizer (APS) at the Korea Global Atmosphere Watch Center (KGAWC) from 6 April, 2006 to 5 April, 2007. Black Carbon (BC), gaseous pollutants of $NO_X$ and $SO_2$ and ${\AA}ngstr\ddot{o}m$ exponent were also measured to examine the properties of the volume size distribution. From distinct difference of the high volume concentration (> $100{\mu}m^3cm^{-3}$), the volume size distribution for each event day was clasified into four types: (1) Type 1 had the high volume concentration for supermicron particles from 2.3 to $6.0{\mu}m$ and maximum average volume concentration was $160.7{\mu}m^3cm^{-3}$ at $3.5{\mu}m$. (2) Type 2 represented the high volume concentration in the both size range of submicron ($0.7-1.0{\mu}m$) and supermicron particles ($2.1-4.1{\mu}m^3cm^{-3}$ and $136.2{\mu}m^3cm^{-3}$ were found at 0.8 and $3.3{\mu}m$ respectively. (3) Type 3 showed the high volume concentration in the size range of $0.5-3.5{\mu}m$ and highest volume concentration of $201.1{\mu}m^3cm^{-3}$ at the particle size bin of $0.8{\mu}m$. (4) Type 4 was characterized by the high volume concentration for the fine particles less than $1.2{\mu}m$ and very high concentration of $446.8{\mu}m^3cm^{-3}$. ${\AA}ngstr\ddot{o}m$ exponent, concentration of gaseous ($NO_X$ and $SO_2$), and particle (BC) pollutants suggested that Type 1 was a typical volume size distribution for the Asian dust and Type 3 provided transportation of air pollutants. The distribution in Type 2 found to have both characteristics of the Asian dust and air pollutants, and Type 4 was took place during the foggy atmosphere containing high density of local pollutants. Based on the properties of volume size distribution, we can identify the three major events contributing the increase of $PM_{10}$ mass concentration, and hope to provide a guideline for discriminating the Asian dust from high $PM_{10}$ events. More case studies and longeto advance this determination method.

An Analysis on Signal Control Efficiency in a Three-Leg Intersection Adopting Pedestrian Push-Button System Following Pedestrian volume (3지 교차로에서 보행자 교통량에 따른 보행자작동신호기를 이용한 신호제어효율에 관한 분석)

  • Kim, Eung-Cheol;Cho, Han-Seon;Jung, Dong-Woo;Kim, Hyoung-Soo
    • International Journal of Highway Engineering
    • /
    • v.11 no.3
    • /
    • pp.121-128
    • /
    • 2009
  • This study has proposed the signal operating system to use both semi-actuated signal control and pedestrian push-button as a way to make up for the problems of 3 leg intersections which are operated inefficiently in the signal operation, one of the methods of traffic operations. In case of the semi-actuated signal control, it can reduce delay inside the intersection by serving to uncongested traffic on the main road where there is not much traffic volume on the secondary road and push-button signal can reduce unnecessary waiting time it could happen to vehicles by operating it though there is no pedestrian. Quantitative analysis was tried regarding the average delay reduction per vehicle using VISSIM, microscopic simulation program regarding how much effect it has compared with the existing signal control system and semi-actuated signal control system when the above two advantages are collected. The field test was performed for one three-leg intersection of Incheon. According to respectively signal control method pedestrian traffic changed and executed a sensitivity analysis. The result which compares the average delay time per a vehicle of scenarios, the signal control method of using the pedestrian push-button system in comparison with the fixed signal control method showed to decrease effect of a minimum 3.7 second (10%), a maximum 5.8 second (16%). When the pedestrian traffic volume was 20% or less of the measurement traffic volume, The signal control method of using the pedestrian push-button system appeared to be more efficient the semi-actuated signal control with object intersection.

  • PDF

Matrix Solid-Phase Dispersion (MSPD) Isolation and Liquid Chromatographic Determination of Residual Furazolidone in Eggs (MSPD 전처리법과 HPLC를 이용한 Furazolidone의 계란내 잔류분석)

  • 서계원;이재일;이채용;이정치
    • Journal of Food Hygiene and Safety
    • /
    • v.18 no.2
    • /
    • pp.43-50
    • /
    • 2003
  • A liquid chromatographic method, using matrix solid-phase dispersion (MSPD) is developed for the extraction of residual furazolidone in chicken eggs. Blank or fortified egg samples (0.5 g) were blended with Octadecylsilyl (Bulk $C_{18}$, 40${\mu}{\textrm}{m}$, 18%. load, endcapped. 2 g) derivatized silica. After homogenization, $C_{18}$/egg and Na$_2$S $O_4$matrix were transferred to a column made of 10 ml glass syringe and filter paper and compressed 4.0∼4.5 ml volume. The column was washed with 8 ml of hexane and dried under $N_2$ gas. Furazolidone was eluted with acetonitrile (8 ml) under gravity. The eluate containing furazolidone was free from interfering compounds when analyzed by HPLC with UV detection (365 nm, photodiode array). Calibration curves were linear (r = 0.99985) and inter- (1.47%) and intra-assay (5.29%) variabilities for the concentration range examined (7.8∼497 ng/g of eggs, 20 ${mu}ell$ injection volume) were indicative of an acceptable methodology for the analysis of furazolidone. Average recovery of furazolidone added to egg was 96.2%. The limit of detection for the proposed method was 1 ng/g for furazolidone. The method using MSPD is proposed as an alternative assay to the classical method which involves the use of large volumes of a harmful solvent and requires a long tedious separation and clean-up processes prior to its determination.

Estimation of the Forest Stand Volumes from Forest Inventory Data Based on Synthetic Estimation Method: A Case of the Economic Forest in Gangwon-do, Republic of Korea

  • Seo, Hwan seok;Park, Jeong mook;Lee, Jung soo
    • Journal of Forest and Environmental Science
    • /
    • v.32 no.2
    • /
    • pp.140-148
    • /
    • 2016
  • This study aims to estimate the forest volumes of the economic forest in Gangwon Province of Republic of Korea (hereinafter referred to as Gangwon) through the synthetic estimation. To estimate the forest volume, Stratified systematic sampling method was used along with the forest type maps and the $5^{th}$ National Forest Inventory data. The synthetic estimation includes sample plots of the expanded areas as well as those of the target area, and the forest volume of economic forest in every city and county throughout Gangwon. Results show that the average forest volume calculated by synthetic estimation was $159.6m^3/ha$ in national economic forest and $129.6m^3/ha$ in private economic forest. The total forest volume of the national economic forest was approximately $59.45million\;m^3$, which was $20.18million\;m^3$ higher than that of the private economic forest. On the other hands, the standard error of the national economic forest was approximately ${\pm}2.21m^3/ha$, which was ${\pm}0.30m^3/ha$ lower than that of the private economic forest. The lowest standard errors was about ${\pm}3.12 m^3/ha$ in broad-leaved forest, followed by ${\pm}4.33m^3/ha$ of mixed forest, and ${\pm}5.78m^3/ha$ of coniferous forest.

Automatic Titration for KMnO4 Consumption Test of Tap Water Using Personal Computer Camera (PC 카메라를 이용한 수돗물의 과망간산칼륨소비량 적정 자동화)

  • Lee, Hyeong-Choon
    • Journal of Environmental Health Sciences
    • /
    • v.34 no.1
    • /
    • pp.95-100
    • /
    • 2008
  • An automatic titration system using a PC-camera with a color filter on its lens was used in the $KMnO_4$ consumption test of tap water and distilled water in relation to blank tests. The very faint pink color of titration end point could be effectively detected by using a yellow cellophane paper as a color filter. The average hue value (Havg) of 192 pixels in the image of the sample solution being titrated was computed and followed up at regular time intervals during titration in order to detect the titration end point. The Havg decrease of 2 degrees from the average of first 10 Havgs was regarded as reaching the end point. The volume of 0.01N $KMnO_4$ consumed by a tap water sample was $0.728{\pm}0.022ml$ in manual titration and $0.735{\pm}0.013ml$ in automatic titration (p=0.580). The volume of 0.01N $KMnO_4$ consumed by a distilled water sample was $0.383{\pm}0.015ml$ in manual titration and $0.367{\pm}0.015ml$ in automatic titration (p=0.252). The high p-values for t-test suggested that there were good agreements between manual and automatic titration data and the automatic method proposed in this article was considered to effectively replace the manual titration.

Volumetric change of the latissimus dorsi muscle after postoperative chemotherapy and radiotherapy in immediate breast reconstruction with an extended latissimus dorsi musculocutaneous flap: final results from serial studies

  • Song, Kyeong Ho;Oh, Won Seok;Lee, Jae Woo;Kim, Min Wook;Jeong, Dae Kyun;Bae, Seong Hwan;Kim, Hyun Yul;Jung, Youn Joo;Choo, Ki Seok;Nam, Kyung Jin;Joo, Ji Hyeon;Yun, Mi Sook;Nam, Su Bong
    • Archives of Plastic Surgery
    • /
    • v.48 no.6
    • /
    • pp.607-613
    • /
    • 2021
  • Background Breast reconstruction using an extended latissimus dorsi (eLD) flap can supplement more volume than reconstruction using various local flaps after partial mastectomy, and it is a valuable surgical method since the reconstruction area is not limited. However, when performing reconstruction, the surgeon should consider latissimus dorsi (LD) volume reduction due to postoperative chemotherapy (POCTx) and postoperative radiotherapy (PORTx). To evaluate the effect of POCTx and PORTx on LD volume reduction, the effects of each therapy-both separately and jointly-need to be demonstrated. The present study quantified LD volume reduction in patients who underwent POCTx and PORTx after receiving breast-conserving surgery (BCS) with an eLD flap. Methods This study included 48 patients who received immediate breast reconstruction using an eLD flap from January 2013 to March 2017, had chest computed tomography (CT) 7-10 days after surgery and 10-14 months after radiotherapy completion, and were observed for more than 3 years postoperatively. One surgeon performed the breast reconstruction procedures, and measurements of breast volume were obtained from axial CT views, using a picture archiving and communication system. A P-value <0.05 was the threshold for statistical significance. Results The average volume reduction of LD at 10-14 months after completing POCTx and PORTx was 64.5% (range, 42.8%-81.4%) in comparison to the volume measured 7-10 days after surgery. This change was statistically significant (P<0.05). Conclusions Based on the findings of this study, when harvesting an eLD flap, surgeons should anticipate an average LD volume reduction of 64.5% if chemotherapy and radiotherapy are scheduled after BCS with an eLD flap.

Comparative Study of the Efficiency of GC with Large Volume Injector and SPE Clean-up Process Applied in QuEChERS Method (GC-대용량 주입장치와 SPE를 적용한 QuEChERS 잔류농약 분석법의 효율성 비교)

  • Park, Young Jun;Hong, Su Myeong;Kim, Taek Kyum;Kwon, Hye Young;Hur, Jang Hyun
    • The Korean Journal of Pesticide Science
    • /
    • v.19 no.4
    • /
    • pp.370-393
    • /
    • 2015
  • This study was conducted to compare STQ method, multi-residue method in Korean food code and QuEChERS method for validated selected and accuracy, reproducibility and efficiency. A total of 45 selected and targeted pesticides were the analyzed by GC and 5 of them were crops (apple, potato, green pepper, rice, soy bean). $R^2$ values were calculated in the standard calibration curve was over 0.990. Recovery tests were performed by three replications in two levels and the relative standard deviation of the repeated experiments was less than 30%. The average percentage of recoveries in the multi-residue method in Korean food code was 89.13%, QuEChERS method was 92.45% and STQ method was 85.28%. In addition, matrix effects in multi-residue method in Korean food code was 24.61%, QuEChERS method was 23.98% and STQ method showed 11.24%. The STQ method is easy and showed high clean-up effect in extracting the sample solution than the QuEChERS method and clean-up with C18, PLS, PSA cartridge columns. A large volume of the sample was injected in order to compensable for the problem, that occurred due to high detection limit in the analyser. When the STQ method was applied using a large volume injector, the standard calibration curve showed a higher linearity $R^2=0.990$, and method detection limit was 0.01 mg/kg. It showed an average recovery of 91.84% and the relative standard deviations of three replications repeated in two level process was less than 30% and had an average matrix effect of 17.90%.

Preparation of Poly-L-Lactic Acid (PLLA) Microspheres by Solvent-Evaporation Method (용매증발법을 이용한 Poly-L-Lactic Acid (PLLA) 마이크로스피어 제조)

  • Kim, Tae Hyoung;Song, Ki Chang
    • Korean Chemical Engineering Research
    • /
    • v.56 no.4
    • /
    • pp.461-468
    • /
    • 2018
  • Microspheres were prepared by solvent-evaporation method with Poly-L-lactic acid (PLLA) as a starting material, and the effects of preparation variables on microsphere shape and average particle size were investigated. As the concentration of PVA solution increased from 1 to 5 wt%, the average particle size decreased from $370{\mu}m$ to $160{\mu}m$ and then increased to $240{\mu}m$ at 7 wt%. On the other hand, As the addition volume of PVA solution increased from 10 mL to 50 mL, the average particle size decreased from $370{\mu}m$ to $220{\mu}m$. Also, as the stirring speed increased from 500 rpm to 1,500 rpm, the average particle size decreased from $370{\mu}m$ to $110{\mu}m$. When dichloromethane and chloroform were used as organic solvents, respectively, the average particle size did not show any significant difference. However, when dichloromethane was used, voids were observed on the particle surface, but when chloroform was used, smooth spherical particles were obtained.

Optimization of Stacking Line and Blade Profile for Design of Axial Flow Fan Blade (중첩선과 단면형상을 고려한 축류 송풍기 날개의 최적설계)

  • Samad, Abdus;Lee, Ki-Sang;Jung, Sang-Ho;Kim, Kwang-Yong
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.420-423
    • /
    • 2008
  • This present work is to find optimum design of a NACA65 axial fan blade with weighted average surrogate model. The numerical analysis by Reynolds-average Navier-Stokes equations with shear stress turbulence(SST) is discretized by finite volume approximations and solved on hexahedral grids for flow analysis. The blade aerodynamic shape is modified by six design variables for the optimization. The blade profile as well as stacking line is modified to enhance blade total efficiency. Six design variables, airfoil maximum camber, maximum camber location, leading edge radius, trailing edge radius, lean angle at 50% span and lean angle at 100% span, are selected for blade profile to enhance the total efficiency. The PBA model which is basically weighted average of the basis surrogates is used to find the optimal design in the design space from the constructed response surface model for the objective function. By the optimization, the total efficiency is increased by 1.4%.

  • PDF