• Title/Summary/Keyword: Average Volume Method

Search Result 535, Processing Time 0.027 seconds

Evaluation of Decomposition Characteristics of Organochlorine Pesticides Using Thermal Method (열적방법을 활용한 유기염소계 폐농약의 분해 특성 평가)

  • Kwon, Eun-Hye;Yoon, Young-Sam;Bea, Ji-Su;Jeon, Tae-Wan;Lee, Young-Ki
    • Journal of Korea Society of Waste Management
    • /
    • v.35 no.8
    • /
    • pp.744-753
    • /
    • 2018
  • The Stockholm Convention, which was adopted in Sweden in 2001 to protect human health and the environment, includes regulations for Persistent Organic Pollutant Rotors such as toxic and bioaccumulatives. Currently, there are 28 types of materials. This prohibits and limits the production, use, and manufacture of products. Korea is a member of the Convention, and it is necessary to prepare management and treatment plans to address the POP trends. Thus, we experimentally investigate whether the environmentally stable incineration is achieved when the sample is thermally treated using the Lab-scale (1 kg/hr). The target samples is pesticides in liquid phase and solid phase. In this study, organic chlorinated pesticides and their thermal characteristics were analyzed. We calculated the theoretical air volume based on the element analysis results. Because the interior of the reactor is small, more than 10 times of the air ratio was injected. The retention time was set to at least 4 seconds using a margin. The incineration temperature was $850^{\circ}C$ and $1100^{\circ}C$. Thus, we experimentally investigated whether the environmentally stable incineration was achieved when the sample was thermally treated using the Lab-scale (1 kg/hr). We analyzed five types of exhaust gas; the 02 concentration was high, but the CO amount decreased. Complete combustion is difficult because of the small size of the furnace due to the nature of Lab-scale. The organic chlorine-containing pesticide had an average decomposition rate of 99.9935%. Considering the decomposition rates of organic chlorine-containing pesticide in this study, the incineration treatment at over 2 ton/hour, which is typical for a conventional incinerator, is possible. Considering the occurrence of dioxins and unintentional persistent organic pollutants, it can operate at more than $1,100^{\circ}C$.

Dielectric Properties of (Ba0.7Sr0.3-3x/2Lax)(Ti0.9Zr0.1)O3 Ceramics with La3+ Substitution for Sr2+-Site ((Ba0.7Sr0.3-3x/2Lax)(Ti0.9Zr0.1)O3 세라믹의 Sr2+-자리에 대한 La3+ 치환에 따른 유전 특성)

  • Si Hyun Kim;Ju Hye Kim;Eung Soo Kim
    • Korean Journal of Materials Research
    • /
    • v.33 no.11
    • /
    • pp.465-474
    • /
    • 2023
  • The effects of La3+ substitution for Sr2+-site on the crystal structure and the dielectric properties of (Ba0.7Sr0.3-3x/2Lax) (Ti0.9Zr0.1)O3 (BSLTZ) (0.005 ≤ x ≤ 0.02) ceramics were investigated. The structural characteristics of the BSLTZ ceramics were quantitatively evaluated using the Rietveld refinement method from X-ray diffraction (XRD) data. For the specimens sintered at 1,550 ℃ for 6 h, a single phase with a perovskite structure and homogeneous microstructure were observed for the entire range of compositions. With increasing La3+ substitution (x), the unit cell volume decreased because the ionic size of La3+ (1.36 Å) ions is smaller than that of Sr2+ (1.44 Å) ions. With increasing La3+ substitution (x), the tetragonal phase fraction increased due to the A-site cation size mismatch effect. Dielectric constant (εr) increased with the La3+ substitution (x) due to the increase in tetragonality (c/a) and the average B-site bond valence of the ABO3 perovskite. The BSLTZ ceramics showed a higher dielectric loss due to the smaller grain size than that of (Ba0.7Sr0.3)(Ti0.9Zr0.1)O3 ceramics. BSLTZ (x = 0.02) ceramics met the X7R specification proposed by the Electronic Industries Association (EIA).

Current Pediatric Endoscopy Training Situation in the Asia-Pacific Region: A Collaborative Survey by the Asian Pan-Pacific Society for Pediatric Gastroenterology, Hepatology and Nutrition Endoscopy Scientific Subcommittee

  • Nuthapong Ukarapol;Narumon Tanatip;Ajay Sharma;Maribel Vitug-Sales;Robert Nicholas Lopez;Rohan Malik;Ruey Terng Ng;Shuichiro Umetsu;Songpon Getsuwan;Tak Yau Stephen Lui;Yao-Jong Yang;Yeoun Joo Lee;Katsuhiro Arai;Kyung Mo Kim; APPSPGHAN Endoscopy Scientific Subcommittee
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.27 no.4
    • /
    • pp.258-265
    • /
    • 2024
  • Purpose: To date, there is no region-specific guideline for pediatric endoscopy training. This study aimed to illustrate the current status of pediatric endoscopy training in Asia-Pacific region and identify opportunities for improvement. Methods: A cross-sectional survey, using a standardized electronic questionnaire, was conducted among medical schools in the Asia-Pacific region in January 2024. Results: A total of 57 medical centers in 12 countries offering formal Pediatric Gastroenterology training programs participated in this regional survey. More than 75% of the centers had an average case load of <10 cases per week for both diagnostic and therapeutic endoscopies. Only 36% of the study programs employed competency-based outcomes for program development, whereas nearly half (48%) used volume-based curricula. Foreign body retrieval, polypectomy, percutaneous endoscopic gastrostomy, and esophageal variceal hemostasis, that is, sclerotherapy or band ligation (endoscopic variceal sclerotherapy and endoscopic variceal ligation), comprised the top four priorities that the trainees should acquire in the autonomous stage (unconscious) of competence. Regarding the learning environment, only 31.5% provided formal hands-on workshops/simulation training. The direct observation of procedural skills was the most commonly used assessment method. The application of a quality assurance (QA) system in both educational and patient care (Pediatric Endoscopy Quality Improvement Network) aspects was present in only 28% and 17% of the centers, respectively. Conclusion: Compared with Western academic societies, the limited availability of cases remains a major concern. To close this gap, simulation and adult endoscopy training are essential. The implementation of reliable and valid assessment tools and QA systems can lead to significant development in future programs.

Comparative Study on the Methodology of Motor Vehicle Emission Calculation by Using Real-Time Traffic Volume in the Kangnam-Gu (자동차 대기오염물질 산정 방법론 설정에 관한 비교 연구 (강남구의 실시간 교통량 자료를 이용하여))

  • 박성규;김신도;이영인
    • Journal of Korean Society of Transportation
    • /
    • v.19 no.4
    • /
    • pp.35-47
    • /
    • 2001
  • Traffic represents one of the largest sources of primary air pollutants in urban area. As a consequence. numerous abatement strategies are being pursued to decrease the ambient concentration of pollutants. A characteristic of most of the these strategies is a requirement for accurate data on both the quantity and spatial distribution of emissions to air in the form of an atmospheric emission inventory database. In the case of traffic pollution, such an inventory must be compiled using activity statistics and emission factors for vehicle types. The majority of inventories are compiled using passive data from either surveys or transportation models and by their very nature tend to be out-of-date by the time they are compiled. The study of current trends are towards integrating urban traffic control systems and assessments of the environmental effects of motor vehicles. In this study, a methodology of motor vehicle emission calculation by using real-time traffic data was studied. A methodology for estimating emissions of CO at a test area in Seoul. Traffic data, which are required on a street-by-street basis, is obtained from induction loops of traffic control system. It was calculated speed-related mass of CO emission from traffic tail pipe of data from traffic system, and parameters are considered, volume, composition, average velocity, link length. And, the result was compared with that of a method of emission calculation by VKT(Vehicle Kilometer Travelled) of vehicles of category.

  • PDF

Effects of Indoor Greening Method on Temperature, Relative Humidity and Particulate Matter Concentration (실내녹화 방법이 온·습도 및 미세먼지 농도에 미치는 영향)

  • Kwon, Kei-Jung;Park, Bong-Ju
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.45 no.4
    • /
    • pp.1-10
    • /
    • 2017
  • This study investigated indoor temperature and humidity control and PM1 and PM10 mitigation effects of a single green wall (Case 1), two green walls (Case 2), and two green walls plus a waterfall (Case 3) in comparison with a control without either a green wall or waterfall. Experiments were conducted in the office of Chungbuk National University from August to September, 2015. Experiments were carried out sequentially in the order of control, Case 1, Case 2, and Case 3. Data collected from August 17 to August 20, 2015 (Experiment 1), and from August 31 to September 3, 2015 (Experiment 2), when outdoor temperature was relatively constant, were analyzed. Plant volume ratios by indoor landscaping of the control, Case 1, Case 2 and Case 3 were 0.0, 0.6, 1.2, and 1.4%, respectively. Compared to the control, average temperatures of Case 1, Case 2 and Case 3 were decreased by 0.3~0.7, 0.7~0.9 and $1.0^{\circ}C$, respectively, and relative humidity was increased by 1.8~8.7, 9.2~14.6 and 14.8~21.9%, respectively. Three hundred minutes after exposure to mosquito repellent incense particles, the ratio of the remaining PM1 of the control, Case 1, Case 2 and Case 3 were 25.0, 22.0%, 21.2%, 17.3%, respectively, in Experiment 1 and 42.3, 28.9, 23.1, and 30.9%, respectively, in Experiment 2. As indoor greening increased the effect of indoor temperature, PM1 and PM10 mitigation were greater, and temperature and humidity were lower. The greater the relative humidity was, the faster PM1 and PM10 mitigation tended to be.

Effects of Fractionated Stereotactic Radiotherapy for Primary Hepatocellular Carcinoma (원발성 간암의 분할 정위방사선치료 효과)

  • Choi Byeong Ock;Kang Ki Mun;Jang Hong Seok;Lee Snag-wook;Kang Young Nam;Chai Gyu Young;Choi Ihl Bhong
    • Radiation Oncology Journal
    • /
    • v.23 no.2
    • /
    • pp.92-97
    • /
    • 2005
  • Purpose : Reports on the outcome of curative radiotherapy for the primary hepatocellular carcinoma (HCC) are rarely encountered in the literature. in this study, we report our experience of a clinical trial where fractionated stereotactic radiotherapy (SRT) was used in treating a primary HCC. Materials and Methods : A retrospective analysis was peformed on 20 patients who had been histologically diagnosed as HCC and treated by fractionated SRT. The long diameter of tumor measured by CT was $2\~6.5$ cm (average: 3.8 cm). A single dose of radiation used in fractionated SRT was S or 10 Gy: each dose was prescribed based on the planning target volume and normalized to $85\~99\%$ isocenter dose. Patients were treated $3\~5$ times per week for 2 weeks, with each receiving a total dose of 50 Gy (the median dose: 50 Gy). The follow up period was $\~55$ months (the median follow up period: 23 months). Results : The response rate was $50\%$ (12 patients), with 4 patients showing complete response ($20%$), 8 patients showing partial response ($40\%$), and 8 patients showing stable disease ($40\%$). The 1-year and 2-year survival rates were $70.0\%$ and $43.1\%$, respectively, and the median survival time was 20 months. The 1-year and 2-year disease free survival rates were $65\%$ and $32.5\%$, respectively, and the median disease-free survival rate was 19 months. Some acute complications of the treatment were noted as follows: dyspepsia in 12 patients ($60\%$), nausea/emesis in 8 patients ($40\%$), and transient liver function impairment in 6 patients ($30\%$). However, there was no treatment related death. Conclusion : The study indicates that fractionated SRT is a relatively safe and effective method for treating primary HCC. Thus, fractionated SRT may be suggested as a local treatment for HCC of small lesion and containing a single lesion, when the patients are inoperable or operation is refused by the patients. We thought that fractionated SRT is a challenging treatment modality for the HCC.

Quantitative Indices of Small Heart According to Reconstruction Method of Myocardial Perfusion SPECT Using the 201Tl (201Tl을 이용한 심근관류 SPECT에서 재구성 방법에 따른 작은 용적 심장의 정량 지표 변화)

  • Kim, Sung Hwan;Ryu, Jae Kwang;Yoon, Soon Sang;Kim, Eun Hye
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.18-24
    • /
    • 2013
  • Purpose: Myocardial perfusion SPECT using $^{201}Tl$ is an important method for viability of left ventricle and quantitative evaluation of cardiac function and now various reconstruction methods are used to improve the image quality. But in case of small sized heart, you should always be careful because of the Partial Volume Effect which may cause errors of quantitative indices at the reconstruction step. So, In this study, we compared those quantitative indices of left ventricle according to the reconstruction method of myocardial perfusion SPECT with the Echocardiography and verified the degree of the differences between them. Materials and Methods: Based on ESV 30 mL of Echocardiography, we divided 278 patients (male;98, female;188, Mean age;$65.5{\pm}11.1$) who visited the Asan medical center from February to September, 2012 into two categories; below the criteria to small sized heart, otherwise, normal or large sized heart. Filtered and output each case, we applied the method of FBP and OSEM to each of them, and calculated EDV, ESV and LVEF, and we conducted statistical processing through Repeated Measures ANOVA with indices that measured in Echocardiography. Results: In case of men and women, there were no significant difference in EDV between FBP and OSEM (p=0.053, p=0.098), but in case of Echocardiography, there were meaningful differences (p<0.001). The change of ESV especially women in small sized heard, significant differences has occurred among FBP, OSEM and Echocardiography. Also, in LVEF, there were no difference in men and women who have normal sized heart among FBP, OSEM and Echocardiography (p=0.375, p=0.969), but the women with small sized heart have showed significant differences (p<0.001). Conclusion: The change in quantitative indices of left ventricle between Nuclear cardiology image reconstruction, no difference has occurred in the patients with normal sized heart but based on ESV, under 30 mL of small sized heart, especially in female, there were significant differences in FBP, OSEM and Echocardiography. We found out that overestimated LVEF caused by PVE can be reduced in average by applying OSEM to all kinds of gamma camera, which are used in analyzing the differences.

  • PDF

Stand Structure and Sapling Growth Characteristics of Korean Red Pine Stands Regenerated by the Seed Tree Method (소나무 모수림 시업지의 임분구조 및 치수생육특성)

  • Lee, Daesung;Choi, Jungkee
    • Journal of Korean Society of Forest Science
    • /
    • v.110 no.4
    • /
    • pp.678-688
    • /
    • 2021
  • This study was conducted to provide growth characteristics and stand information in preparation for natural regeneration method and silvicultural treatment of seed tree method in Korean red pine stands by using the field inventoried data 18 years after the seed tree regeneration method in 2001 and analyzing the stand and sapling characteristics. The study area was located in the Research Forest of Kangwon National University, Chuncheon-si, Gangwon-do. In November 2018, we collected tree measurement factors, such as diameter at breast height (DBH), height, crown class, stem quality, tree age, and annual height increment on the established plots. We calculated the basal area, volume, height-diameter ratio (HD ratio), and additional stand density variables such as the relative density and %stocking to analyze the managed stands. The number of mother trees was 58 trees/ha, with a 17.7% stocking level, whereas the number of saplings was 2,330 trees/ha, with a 79.0% stocking level. In germination, the age distribution of saplings ranged from 2001 to 2007, with most belonging to 15-16 years. The development condition of saplings was 10 cm in DBH and 8 m in height. DBH and height were higher as the crown class is more dominant, and this difference was statistically significant in the analysis of variance and Duncan's multiple comparison test (p<0.0001). HD ratio ranged mostly between 80% and 90%, and more than 95% of sapling stems were of high quality, with a straight, unbroken top, non-sweep, and non-diseased stem. On average, the annual height increment of saplings was 21.9 cm at 1 year, 43.3 cm at 5 years, 54.3 cm at 10 years, and 64.3 cm at 15 years. The overall height growth with age increased smoothly. According to the analysis of covariance, the annual height growth by crown class differed significantly. The regression analysis parameters revealed that annual height growth increased with age and dominant crown class.

Detection of Pathogenic Viruses in the Atmosphere during Asian Dust Events in Incheon City (인천지역에서 황사 기간 동안 대기 중의 바이러스 검출에 관한 연구)

  • Park, Jeong Woong;Lim, Young Hee;Kyung, Sun Young;An, Chang Hyeok;Lee, Sang Pyo;Jeong, Seong Hwan
    • Tuberculosis and Respiratory Diseases
    • /
    • v.59 no.3
    • /
    • pp.279-285
    • /
    • 2005
  • Background : Ambient particles during Asian dust events are usually less than $10{\mu}m$ in size, and known to be associated with the adverse effects on the general population. There is little evidence linking Asian dust to adverse effects on the airways. In 2002, the authors found that particulate matter during Asian dust events had an effect on the symptoms and pulmonary function of patients with bronchial asthma. An aggravating factor might be that of a viral infection, but this remains unclear. Conversely, it has been speculated that African dust may carry the virus responsible for foot and mouth disease. Asian dust events are also likely to be responsible for transporting viruses, some of which are pathogenic, and common in many environments. Therefore, in this study, air samples were screened for the presence of viruses. Methods : Air samples were collected 20 times each during Asian dust events and under non-dust conditions, for at least 6 hours per sample, using a high volume air sampler (Sibata Model HV500F), with an airflow rate of 500L/min, between April and August 2003, and between April and August 2004. The samples were then screened for the presence of targeted viruses (Influenza A, B, Hog cholera virus, and Aphthovirus) using a polymerase chain reaction method. Results : One Asian dust event occurred between April and August 2003, and 3 between April and August 2004, with a 24 hour average PM10 level of $148.0{\mu}g/m^3$. The 24 hour average PM10 level was $57{\mu}g/m^3$. There was a significant difference in the PM10 concentration between dusty and clear days. No viruses (Influenza virus, Aphthovirus, and Hog cholera virus) were identified in the air samples obtained during the dusty days. Conclusions : Although no virus was detected in this study, further studies will be needed to identify suspected viruses carried during Asian dust events, employing more appropriate virus detection conditions.

Evaluation of Electron Boost Fields based on Surgical Clips and Operative Scars in Definitive Breast Irradiation (유방보존술 후 방사선치료에서 수술 흉터와 삽입된 클립을 이용한 전자설 추가 방사선 조사야 평가)

  • Lee, Re-Na;Chung, Eun-Ah;Lee, Ji-Hye;Suh, Hyun-Suk
    • Radiation Oncology Journal
    • /
    • v.23 no.4
    • /
    • pp.236-242
    • /
    • 2005
  • Purpose: To evaluate the role of surgical clips and scars in determining electron boost field for early stage breast cancer undergoing conserving surgery and postoperative radiotherapy and to provide an optimal method in drawing the boost field. Materials and Methods: Twenty patients who had $4{\sim}7$ surgical clips in the excision cavity were selected for this study. The depth informations were obtained to determine electron energy by measuring the distance from the skin to chest wall (SCD) and to the clip implanted in the most posterior area of tumor bed. Three different electron fields were outlined on a simulation film. The radiological tumor bed was determined by connecting all the clips implanted during surgery Clinical field (CF) was drawn by adding 3 cm margin around surgical scar. Surgical field (SF) was drawn by adding 2 cm margin around surgical clips and an Ideal field (IF) was outlined by adding 2 cm margin around both scar and clips. These fields were digitized into our planning system to measure the area of each separate field. The areas of the three different electron boost fields were compared. Finally, surgical clips were contoured on axial CT images and dose volume histogram was plotted to investigate 3-dimensional coverage of the clips. Results : The average depth difference between SCD and the maximal clip location was $0.7{\pm}0.55cm$. Greater difference of 5 mm or more was seen in 12 patients. The average shift between the borders of scar and clips were 1.7 1.2, 1.2, and 0.9 cm in superior, inferior, medial, and lateral directions, respectively. The area of the CF was larger than SF and IF in 6y20 patients. In 15/20 patients, the area difference between SF and if was less than 5%. One to three clips were seen outside the CF in 15/20 patients. In addition, dosimetrically inadequate coverage of clips (less than 80% of prescribed dose) were observed in 17/20 patients when CF was used as the boost field. Conclusion: The electron field determined from clinical scar underestimates the tumor bed in superior-inferior direction significantly and thereby underdosing the tissue at risk. The electron field obtained from surgical clips alone dose not cover the entire scar properly As a consequence, our technique, which combines the surgical clips and clinical scars in determining electron boost field, was proved to be effective in minimizing the geographical miss as well as normal tissue complications.