• Title/Summary/Keyword: Average Volume Method

Search Result 534, Processing Time 0.027 seconds

Real-time Adjustment of Traffic Volume - Based on the National Highway Route 3 (교통량 데이터의 실시간 보정 로직 - 국도 3호선을 중심으로)

  • 이지연;도명식;김성현;류승기
    • The Korean Journal of Applied Statistics
    • /
    • v.16 no.2
    • /
    • pp.203-215
    • /
    • 2003
  • In order to provide the drivers with more reliable transportation information in NHTMS(National Highway Transportation Management System), it is important to estimate the expected passage time by using the traffic volume and speed. In this study, we analyze the characteristics of the traffic volume in the national highway and we investigate two real-time adjustment methods: the average adjustment method and the auto-regressive adjustment method. In addition, we compare them using the real data collected at the National Highway Route 3 in 2000.

Seawater Exchange Ratio in Small Bay (소내만의 해수교환율)

  • Park, Byeong-Su;Ryu, Cheong-Ro
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.33 no.4
    • /
    • pp.266-274
    • /
    • 1997
  • To understand seawater exchange are important to analyze the formation of watermass, material circulation and transfer of pollutant material etc. The purpose of this study is to review the previous studies and to propose new exchange ratio. where,$C_1$ ; average salinity of the water at low water$C_2$ ; average salinity of the water at the next low water$C_0$ ; average salinity of the water passing the bay mouth on the flood tide$V_2$ ; total water volume of the bay on the low water$V_0$ ; the volume of the remaining outer bay water entering during the flood tideSeawater exchange ratio of Dongho Bay calculated by new method are 26.1%, 23.8% respectevely.The average fresh water residence ratio calculated by equation (12) is 2.2 days, that is corresponding 23.5 % of exchange ratio. Thus, it appears similar result as proposed exchange ratio.

  • PDF

Thermal Design of PCR Chip for LOC (랩온어칩을 위한 중합효소 연쇄반응 칩의 열설계)

  • Kim, Deok-Jong;Kim, Jae-Yun;Park, Sang-Jin;Heo, Pil-U;Yun, Ui-Su
    • 연구논문집
    • /
    • s.33
    • /
    • pp.17-25
    • /
    • 2003
  • In this work, thermal design of a PCR chip for LOC is systematically conducted. From the numerical simulation of a PCR chip based on the finite volume method, how to control the average temperature of a PCR chip and the temperature difference between the denaturation zone and the annealing zone is presented. The average temperature is shown to be controlled by adjusting heat input and a cooler as well as a heater is shown to be necessary to obtain three individual temperature zones for polymerase chain reaction. To reduce the time required, a heat sink for the cooler is not included in the calculation domain for the PCR chip and heat sink design is conducted separately by using a compact modeling method, the porous medium approach.

  • PDF

Pressure-volume-temperature gauging method experiment using liquid nitrogen under microgravity condition of parabolic flight

  • Seo, Mansu;Park, Hana;Yoo, DonGyu;Jung, Youngsuk;Jeong, Sangkwon
    • Progress in Superconductivity and Cryogenics
    • /
    • v.16 no.2
    • /
    • pp.64-69
    • /
    • 2014
  • Measuring an exact amount of remaining cryogenic liquid propellant under microgravity condition is one of the important issues of rocket vehicle. A Pressure-Volume-Temperature (PVT) gauging method is attractive due to its minimal additional hardware and simple gauging process. In this paper, PVT gauging method using liquid nitrogen is investigated under microgravity condition with parabolic flight. A 9.2 litre metal cryogenic liquid storage tank containing approximately 30% of liquid nitrogen is pressurized by ambient temperature helium gas. During microgravity condition, the inside of the liquid tank becomes near-isothermal condition within 1 K difference indicated by 6 silicon diode sensors vertically distributed in the middle of the liquid tank. Helium injection with higher mass flow rate after 10 seconds of the waiting time results in successful measurements of helium partial pressure in the tank. Average liquid volume measurement error is within 11% of the whole liquid tank volume and standard deviation of errors is 11.9. As a result, the applicability of PVT gauging method to liquid propellant stored in space is proven with good measurement accuracy.

Detection of Distinctive Points in Impedance Cardiogram during Exercise by Cross-Correlation Method (상호상관 관계를 이용한 운동중의 임피던스 파형에서의 특성점 검출)

  • 오인식;송철규
    • Journal of Biomedical Engineering Research
    • /
    • v.12 no.4
    • /
    • pp.261-266
    • /
    • 1991
  • As the ensemble averaged dz/dt signal during exercise gets smoothed, it is difficult to find the distinctive marks for estimation of stroke volume. The cross correlation function was made use of estimating these marks for automatic calculation by computer from the ensemble averaged dz/dt signal. LVET( Left Ventricular Ejection Time) and stroke volume were estimated based on the calculated parameters from the characteristic points. LVET, stroke volume calculated by hand, by the ensemble average and the cross correlation were compared for accuracy validation.

  • PDF

Design & Animal Experiment of Artificial Oxygenator (인공폐(산화기) 제작과 실험)

  • 김형묵
    • Journal of Chest Surgery
    • /
    • v.15 no.2
    • /
    • pp.259-265
    • /
    • 1982
  • We have designed a new type of bubble oxygenator (KOREA-KIM VENOTHERM OXYGENATOR) made of PVC sheet and deforming mesh incorporated in the heat exchanger, and evaluated in experimental animal for the analysis of it`s efficiency. The Oxygenator has low priming volume with high flow rate up to 6 L/rain, and efficiency of heat exchanger was excellent as 1-$1.5^{\circ}C.$ using total cardiopulmonary bypass method under moderate to deep hypothermia. Average priming volume of 1317 ml with 30% hemodilution method was perfused with an average of 1.1-3.0 L/min.$M^2$of arterial blood and pure oxygen at a rate of 2-3.4 L/min for 49.6 minutes continuously in average. During total cardiopulmonary bypass, average $PaO_2$ was $159.8{\pm}60$mmHg, $PaCO_2$ $41.0{\pm}3$mmHg respectively under $SaO_2$ over 96% with systolic arterial pressure of 70 mmHg and CVP of 5-10 cm$H_2O$. Plasma free Hemoglobin was $7.0{\pm}4$ mg/dl with 25% drop of hemoglobin and hematocrit at the end of cardiopulmonary bypass. This KKV Oxygenator was observed to have excellent capabillty of oxygen and carbon dioxide gas transfer with small amount of blood trauma, and the efficiency of heat exchanger was satisfactory during cooling and rewarming of the bubbled blood. Disadvantages have included the somewhat poor deforming effect due to loose PVC fiber mesh, the extracompact character of Teflon filters, and the rough inner surface of the heat exchanger copper pipes.

  • PDF

Water saving irrigation method in paddy fields (용수절약형 논관개 기법(관개배수 \circled1))

  • 정상옥;안태홍
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.108-113
    • /
    • 2000
  • A field study was performed to investigate the effect of water saving irrigation method on water use efficiency and rice yield. The field plot was 40a (40 ${\times}$ 100m) in size and located at Buryangmyun, Kimjae city, Chonbuk province. Field measurements were made during the growing seasons, May to September of the year 1998 and 1990. Irrigation water volume, drainage water volume, rainfall and ponding depth were measured. Irrigation water management practice employed was such that to keep the ponding depth about 3 to 4cm by intermittent irrigation with drying the soil surface until hair cracks emerge before the next irrigation. The amounts of water volume irrigated and drained were measured by pipe flow meter and ponding depth was observed by using a partly buried 120mm diameter PVC pipe. The results showed that the irrigation water depths, the rainfalls, and the drainage depths were 379mm, 458mm, and 448mm in 1988, and 274mm, 819mm, and 736mm in 1990, respectively. The average yield was 590kg per 10a. The water saving irrigation method saved irrigation water by about 20% with higher yield compared with the traditional method.

  • PDF

A comparison of ventilation effects using bag-valve-mask assist device (백-밸브-마스크 보조장치를 이용한 환기효과 비교)

  • EunYoung, Seo;ByoungGil, Yoon;GaEun, Kim;YougSeok, Kim
    • The Korean Journal of Emergency Medical Services
    • /
    • v.26 no.3
    • /
    • pp.37-46
    • /
    • 2022
  • Purpose: TThe experiment was designed to compare the efficiency of ventilation between conventional BVM ventilation and a newly devised A-BVM ventilation method with Tidal volume, total ventilation rate, average Ventilation speed, and average Ventilation volume. Methods: 40 Paramedical students who agreed to participate in the study were analyzed. Values were measured using IMB PASS after 2 minutes of Brayden Pro manikin with BVM and A-BVM ventilation. The difference in general characteristics was assessed by t-test and ANOVA and the difference in ventilation methods was analyzed by IBM SPSS. Results: A significant difference was found between the two ventilation methods in terms of tidal volume (t=-11.203, p<.001), ventilation time (t=-3.834, p<.001), and optimum ventilation probability (t=10.770, p<.001). A-BVM ventilation method, rather than BVM ventilation method, showed a value close to the appropriate amount recommended by Korean Advanced Life Support (500~600mL) in tidal volume, and higher in optimum ventilation probability. Conclusion: We could identify the a better mode of ventilation. Further studies on the efficacy of existing BVM ventilation methods as compared to device augmented BVM ventilation methods should be carried out to ensure that adequate ventilation is available to patients in clinical practice.

Speed Estimation by Applying Volume Weighted Average Methods in COSMOS (교통량 가중평균 방법을 적용한 COSMOS 속도 추정)

  • Lee Sang-soo;Lee Seung-hwan;Oh Young-Tae;Song Sung-ju
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.2 no.1 s.2
    • /
    • pp.63-73
    • /
    • 2003
  • COSMOS(Cycle, Offset, Split Model for Seoul), a real-time traffic adaptive signal system. estimates queue lengths on each approach on the basis of arithmetic average spot speeds calculated on loop detectors installed at each of two adjacent lanes. In this paper, A new method, a traffic volume-weighted average method, was studied and compared with the existing arithmetic average method. It was found that the relationship between the ratio of volumes of two lanes and the difference of average speed of each lane has a linear form. With field data, The two methods were applied and the proposed method shows more stable and reasonable queue estimation results.

  • PDF

Study on the Water and Material Exchange in Deukryang Bay 1. Volume Transport and Turnover Time of Sea Water (득량만의 해수 교환 및 물질 순환에 관한 연구 1 . 해수의 수송량 및 교환 시간)

  • 조규대;이충일
    • Journal of Environmental Science International
    • /
    • v.7 no.3
    • /
    • pp.311-320
    • /
    • 1998
  • The volume transport and turnover time of the Deukryang Bay. located at the southern area of Korea, were calculated based on the current meter(RCM-7,ACM 16M) data observed at the three gateways of the tegrating observed data and then averaging on time. dangdo and Kogumdo. The total water volume transports through three entrances of the bay in May and October were $3.9{\times}10-2Sv, 3.4{\times}10^{-2}Sv(1Sv=10^6m^3s^{-1}$) and turnover time were 0.97day, 1.12day, respectively. Semidiurnal tides were predominant (70~85%). The water volume transports by residual currents were 2~4% of total water volume transports . The average fraction of fresh water calculated by tidal prism method using salinity difference between inflow current and outflow current through three entrances In Deukryang Bay was about 0.06% of total volume and the flushing time of fresh water was estimated as 0.97day.

  • PDF