• Title/Summary/Keyword: Average Technique

Search Result 2,740, Processing Time 0.033 seconds

Influences of Difference between Day and Night Temperatures (DIF) on Growth and Development of Bell Pepper Plants before and after Transplanting (단고추(피망) 육묘시 주야간 온도차(DIF)가 플러그묘 생장과 정식후 식물의 생육에 미치는 영향)

  • 임기병;손기철;정재동;김종기
    • Journal of Bio-Environment Control
    • /
    • v.6 no.1
    • /
    • pp.15-25
    • /
    • 1997
  • Plug seedlings of bell pepper(Capsicum annuum L.) were grown for 50 days in controlled environment chambers under 12 hrs per day photoperiodic condition with sixteen different day and night temperature regimes to investigate the possibility of height control. The seedlings were then transplanted to greenhouse to investigate the growth, flowering, and yield afterward. Plant height and stem length of seedlings were mainly affected by day temperature rather than night temperature. Internode elongation was suppressed by a negative DIF and was enhanced by a positive DIF even with the same average daily temperature (ADT). Leaf unfolding rate was influenced more by ADT than by DIF. Fresh and dry weights increased as ADT increased. Leaf area and stem diameter increased until temperature increased up to 24$^{\circ}C$ day and night temperature and decreased above 24$^{\circ}C$, The position at which the first flower was initiated was lowered as ADT increased. The first flower degeneration was not obvious up to 24$^{\circ}C$ ADT but increased rapidly above 24$^{\circ}C$ ADT. Seedling compactness(Dry weight per plant height :mg.mm$^{-1}$ ) was greater under -DIF than +DIF condition. In conclusion, DIF treatment was an applicable technique to control stem elongation and growth rate such as leaf unfolding rate and position at which first flower was initiated could be controlled by ADT.

  • PDF

Advanced Victim Cache with Processor Reuse Information (프로세서의 재사용 정보를 이용하는 개선된 고성능 희생 캐쉬)

  • Kwak Jong Wook;Lee Hyunbae;Jhang Seong Tae;Jhon Chu Shik
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.31 no.12
    • /
    • pp.704-715
    • /
    • 2004
  • Recently, a single or multi processor system uses the hierarchical memory structure to reduce the time gap between processor clock rate and memory access time. A cache memory system includes especially two or three levels of caches to reduce this time gap. Moreover, one of the most important things In the hierarchical memory system is the hit rate in level 1 cache, because level 1 cache interfaces directly with the processor. Therefore, the high hit rate in level 1 cache is critical for system performance. A victim cache, another high level cache, is also important to assist level 1 cache by reducing the conflict miss in high level cache. In this paper, we propose the advanced high level cache management scheme based on the processor reuse information. This technique is a kind of cache replacement policy which uses the frequency of processor's memory accesses and makes the higher frequency address of the cache location reside longer in cache than the lower one. With this scheme, we simulate our policy using Augmint, the event-driven simulator, and analyze the simulation results. The simulation results show that the modified processor reuse information scheme(LIVMR) outperforms the level 1 with the simple victim cache(LIV), 6.7% in maximum and 0.5% in average, and performance benefits become larger as the number of processors increases.

Unsteady Free Convection Flow in Horizontal Channels with Arbitrary Wall Temperatures (임의의 벽면온도에 따른 수평채널에서의 비정상 자연대류운동)

  • Im, Goeng
    • The Journal of Engineering Research
    • /
    • v.1 no.1
    • /
    • pp.23-30
    • /
    • 1997
  • Energy transfer by free convection arises in many engineering applications, such as a hot steam radiator for heating a room, refrigeration coils, electric transformers, heating elements and electronic equipments. Generally unsteady natural convection flow in a horizontal channel with arbitrary wall temperatures and the mathematical and physical basis of convection transport has been considered in general. A physically meaningful exact solution of the problem has been obtained in a closed form by the application of the standard finite sine transform technique. Influences of the governing parameters, the Prandtl number and the Rayleigh number, to bring the flow and heat transfer to final steady states have been discussed separately. For constant values of the arbitray wall temperatures and of the function, determining the average axial velocity, the final steady state is approached in different times respectively for the cases when the Prandtl number Pr>1 and Pr<1. It is also seen that the function, representing the axial temperature gradient, is influenced by none of the governing parameters : but the steady state flow is influenced only by the Rayleigh number. There are, of course, many applications. Free convection strongly influences heat transfer from pipes and transmission lines, as well as from various electronic devices. It is also relevant to the environmental sciences, where it is responsible for oceanic and atmospheric motions, as well as related heat transfer processes.

  • PDF

The Cross-Leg Gastrocnemius Muscle Flap for Leg Reconstruction of the Difficult and Unfavorable Conditions (비복근을 이용한 교차하지 근육 피판술)

  • Kim, Ji Ye;Yang, Eun Jung;Hwang, Eun A;Kim, Sug Won
    • Archives of Plastic Surgery
    • /
    • v.36 no.5
    • /
    • pp.583-590
    • /
    • 2009
  • Purpose: In the cases of a vascular compromised condition in an injured lower extremity, soft tissue coverage with free tissue transfer presents a challenging problem to the reconstructive surgeon. For this reason, cross - leg flaps are still used in unusual circumstances. Advances in surgical technique has made the cross - leg free flap possible although it may require long operation time along with significant donor site morbidity. Therefore, a pedicled cross - leg muscle flap may be an alternative treatment modality when local flap or free flap is not possible. Methods: Twelve patients(9 males and 3 females) underwent the operation between October of 2001 and December of 2008. The patients' age ranged from 6 to 82 years. The unusual defects included the regions such as the knee, popliteal fossa, distal third of the tibia, dorsal foot, and the heel. Indications for the cross - leg gastrocnemius flap are inadequate recipient vessels for free flap(in eight cases), extensive soft tissue injuries(in three cases) and free flap failure(in one case). The muscle flap was elevated from contralateral leg and transferred to the soft tissue defect on the lower leg while both legs were immobilized with two connected external fixator systems. Delay procedure was performed 2 weeks postoperatively, and detachment was done after the establishment of the adequate circulation. The average period from the initial flap surgery to detachment was 32 days (3 to 6 weeks). Mean follow - up period was 4 years. Results: Stable coverage was achieved in all twelve patients without any flap complications. Donor site had minimal scarring without any functional and cosmetic problems. No severe complications such as deep vein thrombosis or flap necrosis were noted although mild to moderate contracture of the knee and ankle joint developed due to external fixation requiring 3 to 4 weeks of physical treatment. All patients were able to walk without crutches 3 months postoperatively. Conclusion: Although pedicled cross - leg flaps may not substitute free flap surgery, it may be an alternative method of treatment when free flap is not feasible. Using this modification of the gastrocnemius flap we managed to close successfully soft tissue defects in twelve patients without using free tissue transfers.

Comparative Study of Conventional Phlebectomy and Transiliuminated Powered Phlebectomy in Varicose Veins (하지 정맥류의 고식적 수술 방법과 광투시 전동형 정맥제거술의 비교연구)

  • Lee Choong Won;Chung sung Woon
    • Journal of Chest Surgery
    • /
    • v.38 no.6 s.251
    • /
    • pp.415-420
    • /
    • 2005
  • Recently the cases of varicose veins are increasing because the patients with latent disease have come to realize that they want a positive treatment. Accordingly, the purpose of this study is to compare and analyze two methods the conventional phlebectomy (CP) and transiliuminated powered phlebectomy (TIPP). Material and Method: From March 200f to December 2004, 114 patients (167 legs) with varicose vein were operated in Pusan National University Hospital. A retrospective review was performed on the clinical records. We analyzed age, sex, duration of illness, chief complaints, duplex doppler findings, number of skin incisions, operative time, length of hospitalization, complications, and remnant lesions. Result: Operative time was significantly shorter in the TIPP group than CP group (for one leg $108.4\pm27.6\;min\;vs\;83_4\pm24.4\;min,\;for\;both\;legs\;184.7\pm28.4\;min\;vs\; 137.8\pm24.4\;min)$. There was signifcant statistical difference in average number of skin incisions per leg between the CP group and the TIPP group $(5.9\pm2.2\;vs\;4.2\pm1.6)$. Mean duration of hospitalization was Significantly shorter in the TIPP group than CP group $(4.4\pm1.0\;days\;vs\;5.8\pm1.9\;days)$. Complications were pain $(15.9\%)$, remnant lesion $(9.5\%)$, and ecchymosis $(4.8\%)$ in the CP group and ecchymosis $(19.6\%),\;pain\;(7.8\%),\;and\;remnant\;lesion\;(7.8\%)$ in TIPP group. Sclerotherapy or reopertaion was done for the patients who had remnant lesions. Conclusion: Transilluminated powered phlebectomy in varicose vein could reduce operative time and number of skin incisions, and almost completely removed the multiple lesions. Although there were postoperative complications such as ecclymosis, they were absorbed within 2 months and patients were satisfied. Therefore, TIPP is a more effective operative technique than conventional phlebectomy in varicose veins.

Evaluation of Forest Watershed Hydro-Ecology using Measured Data and RHESSys Model -For the Seolmacheon Catchment- (관측자료와 RHESSys 모형을 이용한 산림유역의 생태수문 적용성 평가 -설마천유역을 대상으로-)

  • Shin, Hyung Jin;Park, Min Ji;Kim, Seong Joon
    • Journal of Korea Water Resources Association
    • /
    • v.45 no.12
    • /
    • pp.1293-1307
    • /
    • 2012
  • This study is to evaluate the RHESSys (Regional Hydro-Ecological Simulation System) simulated streamflow (Q), evapotranspiration (ET), soil moisture (SM), gross primary productivity (GPP) and photosynthetic productivity (PSNnet) with the measured data. The RHESSys is a hydro-ecological model designed to simulate integrated water, carbon, and nutrient cycling and transport over spatially variable terrain. A 8.5 $km^2$ Seolma-cheon catchment located in the northwest of South Korea was adopted. The catchment covers 90.0% forest and the dominant soil is sandy loam. The model was calibrated with 2 years (2007-2008) daily Q at the watershed outlet and MODIS (Moderate Resolution Imaging Spectroradiometer) GPP, PSNnet and 3 year (2007~2009) daily ET data measured at flux tower using the eddy-covariance technique. The coefficient of determination ($R^2$) and the Nash-Sutcliffe model efficiency (ME) for Q were 0.74 and 0.63, and the average $R^2$ for ET and GPP were 0.54 and 0.93 respectively. The model was validated with 1 year (2009) Q and GPP. The $R^2$ and the ME for Q were 0.92 and 0.84, the $R^2$ for GPP were 0.93.

Estimation of Watershed Parameters and Runoff Computation Using GIS (GIS를 이용한 유역매개변수의 추정 및 유출량 산정)

  • Lee, Im-Keun;Ahn, Kyung-Soo
    • Journal of Korea Water Resources Association
    • /
    • v.40 no.1 s.174
    • /
    • pp.11-24
    • /
    • 2007
  • There exist various difficulties in runoff analysis due to many ungauged basins in Korea and the runoff phenomena is also more and more complicated by the change of geologic characteristics due to the urbanization. So, we use GIS technique which is widely used in hydrologic field and cell runoff concept for the fast and effective runoff simulation. This study uses the observations of 6 stage stations in Wi-Cheon watershed and simulates the watershed parameters by using WMS model. We construct DEM by the grids which are consisted based on the criteria of minimum area according to land use. The cell runoff is estimated by an average weighted method using mean annual streamflow and mean maximum daily streamflow obtained from six stage stations. The runoff ratio at arbitrary site is estimated by conducting the direction analysis of streamflow and by removing sinkhole. We compare the simulated and observed runoffs and know that the simulated runoff shows the valid results. So, we could use the geographical information and cell runoff concept for more fast and effective runoff simulation studies.

Influence of Welding Parameters on Macrostructure and Mechanical Properties of Friction-Stir-Spot-Welded 5454-O Aluminum Alloy Sheets (마찰교반점접합한 5454-O 알루미늄합금 판재의 접합부 거시조직 및 기계적 특성에 미치는 접합인자의 영향)

  • Choi, Won-Ho;Kwon, Yong-Jai;Yoon, Sung-Ook;Kang, Myoung-Soo;Lim, Chang-Yong;Seo, Jong-Dock;Hong, Sung-Tae;Park, Dong-Hwan;Lee, Kwang-Hak
    • Journal of Welding and Joining
    • /
    • v.29 no.6
    • /
    • pp.56-64
    • /
    • 2011
  • Friction stir spot welding between 5454 aluminum alloy sheets with the different thicknesses of 1.4 and 1.0 mm was performed. In the welding process, the tool for welding was rotated ranging from 500 to 2500, and plunged to the depth of 1.8 mm under a constant tool plunge speed of 100 mm/min. And then, the rotating tool was maintained at the plunge depth during the dwell time ranging from 0 to 7 sec. The pull-out speed of the rotating tool was 100 mm/min. The increase of tool rotation speed resulted in the change of the macrostructure of friction-stir-spot-welded zone, especially the geometry of welding interface. The results of the tensile shear test showed that the total displacement and toughness of the welds were increased with the increase of the tool rotation speed, although the maximum tensile shear load was decreased. However, the change in the dwell time at the plunge depth of the tool did not produce the remarkable variation in the macrostructure and mechanical properties of the welds. In all cases, the average hardness in friction-stir-spot-welded zone was higher than that of the base metal zone. By the friction stir spot welding technique, the welds with the excellent mechanical properties than the mechanically-clinched joints could be obtained.

Bioequivalence of Two Clarithromycin Tablets (클래리스로마애신 정제의 생물학적 동등성 평가)

  • 김종국;이사원;최하곤;고종호;이미경;김인숙
    • Biomolecules & Therapeutics
    • /
    • v.6 no.2
    • /
    • pp.219-224
    • /
    • 1998
  • The bioequivalence of two clarithromvcin products was evaluated with 16 normal male volunteers (age 23-28 yr, body weight 57.5-75.517g) following single oral dose. Test product was ReYon Clarithromycin tablets (ReYon Pharm. Corp., Korea) and reference product was Klarici $d_{R}$ tablets (Abbott Korea). Both products contain 250 mg of clarithromucin. One tablet of the test or the reference product was administered to the volunteers, respectively, by randomized two period cross-over study (2$\times$2 Latin square method). The determination of clarithromycin was accomplished using a modified agar well diffusion bioassay. As a result of the assay validation, the quantification of clarithromycin in human serum by this technique was possible down to 0.03$\mu$g/ml using 100$\mu$l of serum. The coefficient of variation (C.V.) was less than 10%. Average drug concentrations at each sampling time and pharmacokinetic parameters calculated were not significantly different between two products P>0.05); the area under the curve to last sampling time (24 hr) (AU $Co_{24hr}$ (8.10$\pm$ 1.26 vs 8.22$\pm$ 1.627g . hr/ml), AUC from time zero to infinite (AU $Co_{\infty}$) (8.61 $\pm$ 1.28 vs 8.84$\pm$ 1.71 $\mu$g . hr/ml), maximum plasma concentration ( $C_{msx}$) (0.87$\pm$0.22 vs 0.88$\pm$0.19 $\mu$g/ml) and time to maximum plasma concentration ( $T_{max}$) (2.69 $\pm$0.48 vs 2.56$\pm$ 0.51 hr). The differences of mean AU $Co_{24h}$, $C_{msx}$ and $T_{msx}$ between the two products (1.44, 1.39, and 4.65%, respectively) were less than 20%. The power (1-$\beta$) and treatment difference ($\Delta$) for AU $Co_{24hr}$, and $C_{max}$ were more than 0.8 and less than 0.2, respectivly. Although the power for $T_{max}$ was under 0.8, $T_{max}$. of the two products was not significantly different each other (p>0.05). These results suggest that the bioavailability of ReYon Clarithromycin tablets is not significantly different from that of Klarici $d_{R}$ tablets. Therefore, two products are bioequivalent based on the current results. results.sults.sults.s.s.s.s.s.s.s.

  • PDF

Epidemiological Survey on Metugonimus yokogawui Infection in the Eastern Coast area of Kangwon-Province, Korea (강원도 동해시 황강흡충 감염의 역학적 조사연구)

  • 안영겸;정평림
    • Parasites, Hosts and Diseases
    • /
    • v.25 no.1
    • /
    • pp.59-68
    • /
    • 1987
  • An epidemiological survey on Metagonimus yokogawai infection was performed in the eastern coast area of Kangwon province. Formalin-ether concentration technique and Stoll's dilution egg counting method were employed to figure out the prevalence and intensity of M. yokogawai infection and eating habits of inhabitants with raw freshwater fish. The results are summarized as follows: 1. The prevalence rate of M. yokogawai infection was 6.6% among a total of 2, 357 examinees; 8.6% (115 out of 1, 345) in male and 4.0% (40 out of 1, 012) in female. 2. The prevalence rates were different by the streams where the examinees were residing: 17.8% along the area of Ohsip-cheon (stream), 11.8% along Maeup-cheon, 1.7% along Hwasang-cheon, 1.3% along Yeongok-cheon, 0.9% along Namdae-cheon, 0.9% along Sa-cheon and 0% in the other streams (Yongchon-cheon, Kangnung Namdae-cheon and Jusoo.cheon) in decreasing order. 3. By social strata, the positive rate was 8.0% (122 out of 1, 521) in general inhabitants and 3.9% (33 out of 836) in school children. 4. By the intensity of infection by means of EPG counts in feces; the light infection (less than 400/EPG) was 74.1%, moderate infection (401-1, 000/EPG) 17.3% and heavy infection (more than 1, 001/EPG) 8.6%. 5. Twelves out of 50 sweetfish (Plecoglossus altivelis) (24%) caught from the streams in eastern coast of Kangwon-Do were infected with metacercariae of M. yokogawai, and the number of larvae detected were 70.7 per 6sh in average. The metacercarial infection rates in fish were also different by the streams; 100% in Ohsip-cheon of Samcheok-Gun, 14.3% in Sa-cheon, 16.7% in Yeongokcheon of Myeongju-Gun and 0% in Namdae-cheon of Yangyang-Gun, respectively. 6. Six hundred ninety live (695) out of 1, 396 inhabitants and school children (49.8%) were experienced in eating raw freshwater fishes (Plecoglossus altivezis, Triboledon hakonensis, Coreoperca sp., Morose sp., Carassius sp. & Cyprinus sp. and Zacco platypus). The data were assayed with the questionnaire collected from the examinees. In summarizing the above results, it is known that the Ohsip-cheon area of Samcheok-Gun is highly infected region, and the other areas of Kangnung Namdae-cheon, Yeongok-cheon and Yangyang Namdae-cheon are very lowly infected or non-infected regions for M yokogawai infection.

  • PDF