• Title/Summary/Keyword: Average Annual Cost

Search Result 163, Processing Time 0.025 seconds

Analysis of the Utilization Characteristics of Electrical Power and Equipments on the Farms (농촌의 전력및 전기기기의 이용특성분석)

  • 박승우;류한열
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.17 no.4
    • /
    • pp.3943-3955
    • /
    • 1975
  • The purposes of this study are to evaluate the utilization characteristics of electrical power consumption, to grasp the present trends in the use of electrical equipments, to estimate the demand factor and load factor being held, and to evaluate the efficiency of electical uses for the recently electrified farms cultivating paddy rice. For the purposes, 109 sample farms located in eleven villiages electrified in six different years from 1968 to 1973, were chosen at random and investigated on 35 items concerning to electrical uses and wiring systems. The survey was carried out in 1975, in the vinicity of Suweon city. The results are summarized as follows: i) The average annual power consumption on sample farms is considered to be low, being 242.9 Kwh. in 1974, and varied according to the different electrified year and size of cultivated land, respectively. It has significant positive correlation to the area of farm, too. ii) Between the number of year of electrical uses and the power consumption, there is very significant positive correlation, which could be expressed as Y=43.041+16.108 X, where X represents the number of years of electrical uses. The annual increment of power consumption is much greater at the beginning of the electrification than that at the later years, its average being approximately 20 percent. However, it is recommended that any estimation of long-term increments should be carefully investigated. iii) The monthly power consumption varies considerably throughout a year, in which the heaviest farm load occurs in November. Observing the seasonal variation of consumption, the winter-time is the heaviest season while the summer is the lowest. The result implies house lighting is chief contribution to the present electrical consumption on the farms. Comparing the variation of monthly consumption ratios between the sample farms and industries, the electrical uses on the farms are independant of the industrial uses, and further, the agricultural uses are of inverse pattern to the farms from the results that there is negative correlationship between them, iv) The number of electrical equipments used on the farms are occupied chiefly by lighting sources. Next to the lighting sources, household appliances of small quantity and some motors are used. The mean electrical quantity is about 1, 127.4 watt, which corresponds to about 37.6 per cent to the contracted quantity. The composition of quantity is chiefly occupied by the electrical motor of about 1.5 hp., single-phased. The number of the annual utilization hours of each equipment is tabulated in Table IV-5. In contradiction to the high utilization of lighting sources and small household appliances, the motor is poorly used for approximately 22 hours in a year. v) More than 55 per cent of farms want to purchase new electrical equipments such as small household appliances and electrical motors in their number. The impulse of purchasing such items is stimulated by the contacts to the mass media and their knowledge on such equipments. Consequently, the increase of electrical uses could be prompted by such trials as education and demonstration. vi) The demand and load factors on the farms vary considerably according to the greater variation of the power consumption, daily or monthly. The daily demand factor is 22.4 per cent and load factor 18.6 per cent, while the annual demand factor is 1.3 per cent and load factor 70 per cent approximately. Therefore, the low efficiency of construction cost requires re-evaluation of the present contracted quantity of 3 Kw. or increase of electrical uses. vii) The electrical energy on the farms devoted chiefly to lighten the farm residences does not contribute to the farm incomes. Consequently, the cost of electrical consumption presses considerably upon the farm economy. Therefore, there is great need to build up the electrical uses on the farms through the development of new works and techinques to utilize any electrical equipments on the production of farm products. Further more, such the development should be related to increase the actual income of the farm consumers.

  • PDF

A Study on Sickness and the Status of Medical Care in a Rural Area (일부(一部) 농촌주민(農村住民)의 상병(傷病) 및 의료실태(醫療實態)에 관(關)한 조사연구(調査硏究))

  • Park, Jeong-Sun
    • Journal of Preventive Medicine and Public Health
    • /
    • v.14 no.1
    • /
    • pp.65-74
    • /
    • 1981
  • This survey was made to determine the overall health situation on (1) the status of sickness; (2) the medical care utilization; (3) the medical cost in Mi-Kum Myun, Nam Yang Ju Gun, Kyung-Gi Do. The survey with questionnaire was carried out with 2,840 peoples in 560 households from August 9th to 16th, 1979. The findings from the survey were as follows; 1. Annual morbidity rate of the prolonged ill cases was 97.2 per 1,000 population (male 94.7, female 99.6), The highest age specific morbidity rate was 274.5 of the 45-to 64-year group and the lowest was 21.9 of the 5-to 14-year group. 2. Annual morbidity rate of the new patients was 777.5 per 1,000 population(male 644.5, female 909.5). 3. The chief complaints distribution of the prolonged ill cases was: local pain 36.6%, indigestion 22.4%, and coughing 7.3%, respectively, In terms of age and sex distribution, a large number of female of the 45-to 64-year group complained of local pain or general pain and a large number of both sexes of the 25-to 44-year group complaned of indigestion. 4. The major diseases of the new patients which classified with International Classfication of Diseases (I.C.D.) were disease of the respiratory system, disease of the digestive system, and disease of the musculo-skeletal system and connective tissue for male, disease of the respiratory system, disease of the digestive system, and accident, poisoning, violence for female. 5. Total ill days of the 92 new patients were 536 days and average ill days per case were $6{\pm}38.3$ days. 6. The rate of receiving treatment in the prolonged ill cases was 82.2%(medical facilities 46.4%, drug stores 27.5%, herb medicine 8.3%). 7. The rate of receiving treatment by first choice of the new patients was 88.0% (drug stores 57.%, medical facilities 28.2%, and herb medicine 2.2%), and the rate of receiving treatment by second choice was 30.9% of first treatment cases (medical facilities 44.0%, drug store 44.0% and herb meicine 12.0%). 8. Annual hospitalization rate per 1,000 population was 12.0 (male 12.0, female 11.9). 9. The locations of medical facilities utilized by out-patients were: in the prolonged ill cases Seoul or other places 66.4%, Nam Yang Ju Gun 33.6%, in cases of the new patients Seoul or other places 35.1% and Nam Yang Ju Gun 64.9% respectively. 10. The satisfaction rate of the new patients by mode of receiving treatment was: in cases of primary utilization by first choice herb medicine 100.0%, medical facilities 88.5%, and drug stores 69.8%, in cases of secondary utilization medical facilities 100.0%, herb medicine 100.0%, and drug stores 72.7% respectively. 11. The medical cost per utilized facilities was as follows; in average medical fee per case out-patient 8.947 won, in-patient 266,000 won, drug stores 1,532 won, and herb medicine 15,607 won, in average medical fee per day out-patient 4,829 won, in patient 14,178 won, drug stores 891 won, and herb medicine 4,906 won respectively. 12. The sources of the hospital charges paid out were: there own expense 50.0%, debt 35.3%, and security of medical care 14.7% respectively.

  • PDF

The Effect of Energy Efficiency Investment on Industry's Productivity Growth (에너지효율화 투자의 산업생산성 파급효과 분석)

  • Lee, Myunghun
    • Environmental and Resource Economics Review
    • /
    • v.20 no.2
    • /
    • pp.291-308
    • /
    • 2011
  • The success of a target of 'low-carbon green growth' depends on whether installing energy-saving capital would result in an increase in industry's productivity growth. Defining total factor productivity from a dual cost function, this paper estimates the contribution of energy efficiency investment to productivity growth by analyzing the sources of growth of productivity index for the primary metal industries. Empirical results show that, on average, energy efficiency investment increased the annual rate of productivity growth by 1.16 percentage points over th period 1982~2006. In addition, The scale effect positively affected the contribution of energy efficiency investment on productivity growth.

  • PDF

ARIMA Based Wind Speed Modeling for Wind Farm Reliability Analysis and Cost Estimation

  • Rajeevan, A.K.;Shouri, P.V;Nair, Usha
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.4
    • /
    • pp.869-877
    • /
    • 2016
  • Necessity has compelled man to improve upon the art of tapping wind energy for power generation; an apt reliever of strain exerted on the non-renewable fossil fuel. The power generation in a Wind Farm (WF) depends on site and wind velocity which varies with time and season which in turn determine wind power modeling. It implies, the development of an accurate wind speed model to predict wind power fluctuations at a particular site is significant. In this paper, Box-Jenkins ARIMA (Auto Regressive Integrated Moving Average) time series model for wind speed is developed for a 99MW wind farm in the southern region of India. Because of the uncertainty in wind power developed, the economic viability and reliability of power generation is significant. Life Cycle Costing (LCC) method is used to determine the economic viability of WF generated power. Reliability models of WF are developed with the help of load curve of the utility grid and Capacity Outage Probability Table (COPT). ARIMA wind speed model is used for developing COPT. The values of annual reliability indices and variations of risk index of the WF with system peak load are calculated. Such reliability models of large WF can be used in generation system planning.

Comparison of Position and Trend of Disease Burden in Korea and Organization for Economic Cooperation and Development Countries (한국과 경제협력개발기구 국가의 질병부담 위치와 추이 비교)

  • Yun Hwa Jung;Hye Jin Joo;Eun-Cheol Park
    • Health Policy and Management
    • /
    • v.33 no.2
    • /
    • pp.129-140
    • /
    • 2023
  • Background: This study aims to compare the burden of disease in Korea with other Organization for Economic Cooperation and Development (OECD) countries using the OECD health statistics from 1985 to 2020. Methods: We analyzed potential years of life lost (YLL) per 100,000 population using the Positive value for relative comparison (PARC) index, trend test, and average annual percentage change (AAPC) with logistic regression analysis. Results: The relative disease burden was good for many diseases, but the disease burden was severe for a few diseases in Korea. Diseases with a high relative burden of disease in Korea are as follows; intentional self-harm (YLL2020 575.6, AAPCYLL 2.6%; PARC2020 -1.000, AAPCPARC -15.8%), malignant neoplasms of the liver (YLL2020 136.6, AAPCYLL -3.9%; PARC2020 -1.000, AAPCPARC 0.0%), malignant neoplasms of the stomach (YLL2020 9.0, AAPCYLL 3.2%; PARC2020 -0.556, AAPCPARC -22.9%), Parkinson's disease (YLL2020 575.6, AAPCYLL 2.6%; PARC2020 -1.000, AAPCPARC -15.8%). Conclusion: Diseases with a high burden of disease are needed to be prioritized in the planning and execution of healthcare policies that can contribute to the efficient use of healthcare resources.

VALUATION OF A MULTI-STAGE RAINWATER HARVESTING TANK CONSTRUCTION USING A REAL OPTION APPROACH

  • Byungil Kim;Hyoungkwan Kim;SangHyun Lee
    • International conference on construction engineering and project management
    • /
    • 2013.01a
    • /
    • pp.386-389
    • /
    • 2013
  • Under climate change and urbanization, rainwater harvesting (RWH) systems are emerging as an alternative source of water supply because of growing concern about water sustainability. RWH systems can satisfy the various watering needs and provide the environmental benefits of lessening the damages from flood, drought, and runoff. The economic success of a RWH system is vitally concerned with the determination of the design capacity of storage tank to be built in the system. The design capacity is determined by the factors of average annual rainfall, period of water scarcity, and water price during the whole life-cycles. Despite the high uncertainties inherent in these factors, the current engineering design of RWH system construction often assumes that storage tanks should be built all at once. This assumption implicitly ignores the managerial flexibility in responds to the future as new information comes out-the right to build storage tanks stage by stage depending on the evolution of demand. This study evaluates the value of a multistage storage tank construction using a real option approach. A case study involving a typical RWH system construction in Jeonju, the Republic of Korea is conducted. The managerial flexibility obtained from the real option perspective allows engineers to develop investment strategies to better cope with the issue of water sustainability.

  • PDF

Productivity effects of Hanwoo genetic improvement program

  • Jae Bong Chang;Sanghyen Chai
    • Korean Journal of Agricultural Science
    • /
    • v.50 no.4
    • /
    • pp.869-881
    • /
    • 2023
  • A genetic improvement program in Korea was implemented to improve the performance of Hanwoo cattle by generating livestock with genetically desirable economic characteristics. In particular, in response to external changes, such as the expansion of Free Trade Agreement (FTA), the livestock genetic improvement program has increased farm income by improving the productivity and quality of Hanwoo cattle. Using production cost data from Statistics Korea, the total input and output indices of Hanwoo feeding cattle from 2008 - 2021 were estimated and the growth and productivity changes were analyzed. The productivity change measures results were used to estimate the cumulative effects of the Hanwoo genetic improvement program on quality improvement, another purpose of the program, using a finite distributed lag model. The average annual increase in output (market weight) of Hanwoo was 0.9%. However, total input increased by 1.6%, resulting in a 0.6% decline in total factor productivity. In contrast, the Hanwoo genetic improvement program contributed significantly to the production of high quality beef, rather than contributing to improved productivity of the cattle. Hanwoo carcass weight, which is used as a performance indicator for the livestock genetic improvement program, has significantly improved and is projected to increase at a slower rate. The collective findings indicate the need for new performance indicators that can comprehensively indicate the performance of the genetic improvement of Hanwoo.

Design of Heliostat Field for 200kW Tower Type Solar Thermal Power Plant (200kW 탑형 태양열발전시스템의 Heliostat Field 설계)

  • Park, Young Chil
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.5
    • /
    • pp.41-51
    • /
    • 2012
  • Heliostat field is the most important subsystem in the tower type solar thermal power plant since its optical performance affects the total system efficiency most significantly while the construction cost of it is the major part of total construction cost in such a power plant. Thus a well designed heliostat field to maximize the optical efficiency as well as to minimize the land usage is very important. This work presents methodology, procedures and result of heliostat filed design for 200kW solar thermal power plant built recently in Daegu, Korea. A $2{\times}2(m)$ rectangular shaped receiver located at 43(m) high and tilted $28^{\circ}$ toward heliostat field, 450 of heliostats of which the reflective surface is formed by 4 of $1{\times}1(m)$ flat plate mirror facet, and the land area having about $140{\times}120(m)$ size are used to form the heliostat field. A procedure to deploy 450 heliostats in radial staggered nonblocking formation is developed. Also the procedures to compute the cosine effect, intercept ratio, blocking and shading ratio in the field are developed. Finally the heliostat filed is designed by finding the optimal radial distance and azimuthal spacing in radial staggered nonblocking formation such that the designed heliostat field optical efficiency could be maximized. The designed heliostat field has 77% of annual average optical efficiency, which is obtained by annually averaging the optical efficiencies computed between the time of where sun elevation angle becomes $10^{\circ}$ after sunrise and the time of where sun elevation angle becomes $10^{\circ}$ before sunset in each day.

Comprehensive Analysis of Major Factors Associated with the Performance of Reverse Osmosis Desalination Plant for Energy-saving (에너지 소모를 고려한 역삼투 해수담수화 플랜트 주요 성능인자 영향 분석)

  • Kim, Jihye;Lee, Kyung-Hyuk;Lim, Jae-Lim
    • Membrane Journal
    • /
    • v.29 no.6
    • /
    • pp.314-322
    • /
    • 2019
  • A worsened drought in Chungnam province of Korea due to climate change and increasing water demand at Daesan industrial complex have motivated the 100,000 ㎥/d seawater desalination project. In this study, therefore, the comprehensive analysis of parameters affecting the reverse osmosis (RO) performance was conducted. Under the various conditions of feedwater salinity and temperature in Daesan, energy consumption was calculated as 2.39 ± 0.13 kWh/㎥. The decrease in membrane flux and recovery rate positively impacted annual operation cost. The average total dissolved solids (TDS) of the permeate and energy consumption with highly permeable membrane according to the membrane manufacturer were 3.84 mg/L and 2.22 ± 0.13 kWh/㎥, respectively. In addition, energy saving up to 0.29 kWh/㎥ or cost reduction of membrane module up to 15.6% is expected by changing the RO configuration from full two pass to partial or split partial two pass.

The Determinants of Profitability Performance in Regional Public Hospitals (지방의료원 수익성과에 대한 결정요인 분석)

  • Hong, Mi-Yeong;Lee, Hae-Jong;Joo, Hyun-Sil;Lee, Dong-Won
    • Korea Journal of Hospital Management
    • /
    • v.14 no.2
    • /
    • pp.1-20
    • /
    • 2009
  • The purpose of this study is to find the determinant variables to make profitability in regional public hospitals. The data come from financial statements and annual reports of 34 regional public hospitals for five years (from year 2003 to year 2007). The T or F-test and hierarchical multiple regression analysis are used. The dependant variables are the profitability indicators, ordinary income to total asset and operating margin to gross revenue, and the independent variables are general characteristics, diagnosis and treatment patterns, financial and public benefits. The findings of this study are summarized as follows. First, Variables affecting the profitability indexes revealed from DEA results is the bed occupancy rate, number of hospitalized patients to outpatients, ratio of first medical examination for outpatients, number of daily patients per medical specialist, labor cost per patient and managerial expenses per patient. Second, the ordinary income to total asset representing the asset usage performance is affected by the average hospitalized days, bed occupancy rate, labor cost per patient and ratio of patients with medical insurance coverage. Third, the operating martin to gross revenue obtained from the actual operations of hospitals has its significance with the bed occupancy rate, number of hospitalized patients to outpatients, managerial expenses per patient and public benefit indicator. This study has some restriction not to use pannel data analysis, although it used data for five years. Accordingly, various additional studies should be done to supplement such problems.

  • PDF