• Title/Summary/Keyword: Available transfer capability

Search Result 54, Processing Time 0.022 seconds

ATM Interface Technologies for an ATM Switching System

  • Park, Hong-Shik;Kwon, Yool;Kim, Young-Sup;Kang, Seok-Youl
    • ETRI Journal
    • /
    • v.18 no.4
    • /
    • pp.229-244
    • /
    • 1997
  • Realization of the economical, reliable, and efficient ATM interface block becomes an important key to development of the ATM switching system when we consider new issues raised recently. In this paper, we summarize requirements for the ATM interface block and present the UNI (User Network Interface)/NNI (Network Node Interface) architecture to meet these requirements. We also evaluate the performance of the multiplexer adopting the various multiplexing schemes and service disciplines. For ATM UNI/NNI interface technologies, we have developed a new policing device using the priority encoding scheme. It can reduce the decision time for policing significantly. We have also designed a new spacer that can space out the clumped cell stream almost perfectly. This algorithm guarantees more than 99 % conformance to the negotiated peak cell rate. Finally, we propose the interface architecture for accommodation of the ABR (Available Bit Rate) transfer capability. The proposed structure that performs virtual source and virtual destination functions as well as a switch algorithm can efficiently accommodate the ABR service.

  • PDF

Calculation of TRM and CBM for Electricity Market Restructuring (전력 산업 구조 개편 상황에서 적정 송전 용량 여유도 산정)

  • Shin, Sang-Hun;Shin, Dong-Joon;Kim, Jin-O;Lee, Hyo-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.429-431
    • /
    • 2003
  • Available Transfer Capability(ATC) calculation is a complicated task, which involves the determination of TTC, TRM, and CBM. This paper proposed QFA method, which can reduce the calculation time comparing with CPF method and has few errors in ATC calculation. It proved that the method can calculate ATC more fast and accurately in the case study using IEEE 24 bus RTS(MRTS).

  • PDF

Two-Stage Model for Security Network-Constrained Market Auction in Pool-Based Electricity Market

  • Kim, Mun-Kyeom
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.6
    • /
    • pp.2196-2207
    • /
    • 2017
  • This paper presents a two-stage market auction model in a pool-based electricity market, which explicitly takes into account the system network security. The security network-constrained market auction model considers the use of corrective control to yield economically efficient actions in the post-contingency state, while ensuring a certain security level. Under this framework, the proposed model shows not only for quantifying the correlation between secure system operation and efficient market operation, but also for providing transparent information on the pricing system security for market participants. The two-stage market auction procedure is formulated using Benders decomposition (BD). In the first stage, the market participants bid in the market for maximizing their profit, and the independent system operator (ISO) clears the market based on social welfare maximization. System network constraints incorporating post-contingency control actions are described in the second stage of the market auction procedure. The market solutions, along with the BD, yield nodal spot prices (NSPs) and nodal congestion prices (NCPs) as byproducts of the proposed two-stage market auction model. Two benchmark systems are used to test and demonstrate the effectiveness of the proposed model.

Damage detection of mono-coupled multistory buildings: Numerical and experimental investigations

  • Xu, Y.L.;Zhu, Hongping;Chen, J.
    • Structural Engineering and Mechanics
    • /
    • v.18 no.6
    • /
    • pp.709-729
    • /
    • 2004
  • This paper presents numerical and experimental investigations on damage detection of mono-coupled multistory buildings using natural frequency as only diagnostic parameter. Frequency equation of a mono-coupled multistory building is first derived using the transfer matrix method. Closed-form sensitivity equation is established to relate the relative change in the stiffness of each story to the relative changes in the natural frequencies of the building. Damage detection is then performed using the sensitivity equation with its special features and minimizing the norm of an objective function with an inequality constraint. Numerical and experimental investigations are finally conducted on a mono-coupled 3-story building model as an application of the proposed algorithm, in which the influence of modeling error on the degree of accuracy of damage detection is discussed. A mono-coupled 10-story building is further used to examine the capability of the proposed algorithm against measurement noise and incomplete measured natural frequencies. The results obtained demonstrate that changes in story stiffness can be satisfactorily detected, located, and quantified if all sensitive natural frequencies to damaged stories are available. The proposed damage detection algorithm is not sensitive to measurement noise and modeling error.

Bandgap capability of hybrid Kirigami inspired cellular structures

  • Del Broccolo, S.;Ouisse, M.;Foltete, E.;Scarpa, F.
    • Advances in aircraft and spacecraft science
    • /
    • v.6 no.6
    • /
    • pp.479-495
    • /
    • 2019
  • Periodic cellular core structures included in sandwich panels possess good stiffness while saving weight and only lately their potential to act as passive vibration filters is increasingly being studied. Classical homogeneous honeycombs show poor vibracoustic performance and only by varying certain geometrical features, a shift and/or variation in bandgap frequency range occurs. This work aims to investigate the vibration filtering properties of the AUXHEX "hybrid" core, which is a cellular structure containing cells of different shapes. Numerical simulations are carried out using two different approaches. The first technique used is the harmonic analysis with commercially available software, and the second one, which has been proved to be computationally more efficient, consists in the Wave Finite Element Method (WFEM), which still makes use of finite elements (FEM) packages, but instead of working with large models, it exploits the periodicity of the structure by analysing only the unit cell, thanks to the Floquet-Bloch theorem. Both techniques allow to produce graphs such as frequency response plots (FRF's) and dispersion curves, which are powerful tools used to identify the spectral bandgap signature of the considered structure. The hybrid cellular core pattern AUXHEX is analysed and results are discussed, focusing the investigation on the possible spectral bandgap signature heritage that a hybrid core experiences from their "parents" homogeneous cell cores.

Development of Nutrient Solution Cooling System in Hydroponic Greenhouse (수경재배 온실의 양액냉각시스템 개발)

  • 남상운;김문기
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.36 no.3
    • /
    • pp.113-121
    • /
    • 1994
  • Since it is difficult to expect the normal production of plants in greenhouses during hot summer season in Korea, certain provisions on the control of extreme environmental factors in summer should be considered for the year-round cultivation in greenhouses. This study was carried out to find a method to suppress the temperature rising of nutrient solution by cooling, which is able to contribute to the improvement of the plant growth environment in hydroponic greenhouse during hot summer season. A mechanical cooling system using the counter flow type with double pipe was developed for cooling the nutrient solution efficiently. Also the heat transfer characteristics of the system was analysed experimentally and theoretically, and compared with the existing cooling systems of nutrient solution. The cooling capacities of three different Systems, which used polyethylene tube in solution tank, stainless tube in solution tank, and the counter flow type with double pipe, were evaluated. The performance of each cooling system was about 41 %, 70% and 81 % of design cooling load in hydroponic greenhouse of 1 ,000m$^2$ on the conditions that the flow rate of ground water was 2m$^3$/hr and the temperature difference between two liquids was 10 ˚C According to the results analysed as above, the cooling system was found to have a satisfactory cooling capability for regions where ground water supply is available. Fer the other regions where ground water supply is restricted, more efficient cooling System should be developed.

  • PDF

A Study on Enhancement Available Transfer Capability Using STATCOM (STATCOM을 이용한 지역간 융통전력 증대방안에 관한 연구)

  • Kim Yang il;Jeung Sung Won;Shin Woon Yong;Kwak Sang Un;Kim Jae Hyeon
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.156-158
    • /
    • 2004
  • Recently electrical industry has been rapidly restructured by deregulation in the developed countries. The voltage stability problem of a power system is associated with a rapid voltage drop due to heavy load and it occurs because of inadequate reactive power supply at some critical buses. More effective power system control means for line flow and bus voltage are required for applying FACTS. In this paper Jacobian method used to study on the voltage stability, The Jacobian method is to check the eigenvalue of the load flow Jacobian matrix. If the power system is unstable, one of the eigenvalues, at leasL has crossed the imaginary axis. This paper demonstrate enhancement of ATC by application of STATCOM at WSCC 9-bus system.

  • PDF

Traffic Management Scheme for Supporting QoS of VBR/ABR Services in ATM Switching Systems (ATM 스위칭 시스템의 VBR/ABR 서비스 품질 지원을 위한 트랙픽 관리 기법)

  • 유인태
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.8A
    • /
    • pp.1160-1168
    • /
    • 2000
  • This paper presents a real-time integrated traffic management (RITM) scheme that can effectively manage variable bit rate (VBR) and available bit rate (ABR) traffics having unpredictable characteristics in asynchronous transfer mode (ATM) networks. An unique feature of this scheme is that it has a special ATM cell control block which makes it possible to monitor bursty traffics in real-time so that the delay incurred to measure cell arrival rate is minimized. Additionally, the proposed scheme intends to dynamically reassign the leftover network resources to VBR/ABR connections without any deterioration in quality of service (QoS) of the existing connections. The RITM scheme has been verified to reliably monitor incoming traffics and to efficiently manage network resources by computer simulations. The capability of managing the incoming ATM traffics in real-time helps determine an optimal acceptable number of user connections for a given network condition. We can use this value as a threshold to protect the network from being congested and to find out a cost-effective buffer design method.

  • PDF

Development of KITSAT. The First Korean Satellite and Space Development Strategy (우리별 위성개발(衛星開發)과 우주개발정책(宇宙開發政策)의 과제(課題))

  • Choi, Soon-Dal
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.6
    • /
    • pp.267-283
    • /
    • 1994
  • Application of space technology in the field of communication and remote sensing becomes increasingly important in human life. Advancement of communications means shinks the size of our globe and that of remote sensing techniques improves the quality of human well-being. It is a world trent for each country to make its best effort in advancing its capabilities in these fields sometimes independently and other times jointly with other nations. Korea being no exception to this world trend is planning various starategies in application and development of space technologies. However, unfortunately, Korea is a new commer in this field. Statellite Technology Research Center (SaTReC) of Korea Advanced Institute of Science and Technology (KAIST) initiated to aquire satellite technology by sending its graduates abroad in 1989. As a result KITSAT-1 was launched in 1992 and KITSAT- 2 was launched in 1993 and they became Korea's first two satellites in orbits. Academic program including On-the Job-Training for Korean students at the University of Surrey, UK, is also an innovative scheme of mixing education and practical know-how for successful technology transfer, which resulted in a small but very capable and effective satellite experts group in Korea for self-propelled research and development in space activities. In this context, space development strategy should be considered in terms of the following factors; (1). Participation in international space activities as an active member to utilize international organization and to contribute to the peaceful use of space, (2). Development of national defence structure for independent activities in space, (3). Enhancement of manpower utilization for space development and promotion of national pride and (4). Education of youngsters for the extension of intellectual activities into the limitless space. In order to make very costly space development project most efficient, governmental level space development organization directed by the head of nation should be established and should manage all space development programs making full use of its all available resources including the advantage of the university based R&D capability.

  • PDF

Assessment of RELAP5/MOD2 Code using Loss of Offsite Power Transient of Kori Unit 1 (고리 1호기 외부 전원 상실사고에 의한 RELAP5/MOD2코드 모델 평가)

  • Chung, Bub-Dong;Kim, Hho-Jung;Lee, Young-Jin
    • Nuclear Engineering and Technology
    • /
    • v.22 no.1
    • /
    • pp.12-19
    • /
    • 1990
  • The Loss of Offsite Power Transient at 77.5% power which occurred on June 9, 1981 at the Kori Unit 1 PWR (Pressurized Water Reactor) is simulated using the RELAP5/MOD2 system thermal-hydraulics computer code. Major thermal-hydraulic parameters are compared with the available plant data. The comparison of the analysis results with the plant data demonstrates that the RELAP5/MOD2 code has the capability to simulate the thermal-hydraulic behaviour of PWRs under accident conditions of this type with accuracy, except the pressurizer pressure and level. The pressurizer pressure increase is sensitive to the in surge now it is believed that the interracial heat transfer in a horizontal stratified flow regime may be estimated low and the compression effect due to insurge flow may be high. In the nodalization sensitivity study it is found that S/G noding with junctions between bypass plenum and steam dome is preferred to simulate the S/G water level decreasing and avoid the spurious level peak at trubine trip.

  • PDF