• Title/Summary/Keyword: Available test time

Search Result 511, Processing Time 0.028 seconds

Bioavailability of Commercially Available Aspirin Tablets in Human (시판 아스피린 정제의 생체내 이용율)

  • Lee, Jin-Hwan;Choi, Jun-Shik;Baik, Chai-Sun;Burm, Jin-Pil
    • Journal of Pharmaceutical Investigation
    • /
    • v.19 no.3
    • /
    • pp.131-136
    • /
    • 1989
  • This study was attempted to investigate the dissolution rate and the bioavailability after oral administration of commercially available aspirin tablets in normal volunteers. The dissolution test was conducted in artificial gastric juice using basket method with three aspirin preparations (A, B and C) which were chemically equivalent. The results were as follows; The dissolution rate was higher in the order of three different brand B>A >C. Area under the blood concentration and peak blood concentration were larger in the order of brand A>B>C. Absorption rate constant and peak time were larger in the order of brand B>A>C, and there was a little difference in elimination rate constant and biological half-life. The correlation of the dissolution rate and absorption rate constant, as well as correlation of the dissolution rate and peak time showed significant linear relationship respectively. From the results of this experiment, it can be concluded that the bioavailability of aspirin tablets showed much difference according to commercial preparations, and that the bioavailability of aspirin tablets in human may be predicted from the results of dissolution rate studies.

  • PDF

A Dynamic Simulation of Distance Relay Using EMTP MODELS (EMTP MODELS를 이용한 거리 계전기 응동 시뮬레이션)

  • 허정용;김철환;여상민
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.1
    • /
    • pp.17-28
    • /
    • 2003
  • Digital technology has advanced very significantly over the years both in terms of software tools and hardware available. It is now applied extensively in many area of electrical engineering including protective relaying in power systems. Digital relays based on digital technology have many advantages over the traditional analog relays. The digital relay is able to do what is difficult or impossible in the analog relays. However, the complex algorithms associated with the digital relays are difficult to test and verify in real time on real power systems. Although non real-time simulators like PSCAD/EMTDC are employed to test the algorithms, such simulations have the disadvantage that they cannot test the relay dynamically. Hence, real-time simulators like RTDS are used, but the latter needs large space and it is very expensive. This paper uses EMTP MODELS to simulate the power system and the distance relay. The distance relay algorithm is constructed and the distance relay is interfaced with a test power system. The distance relays performance is then assessed interactively under various fault types, fault distances and fault inception angles. The test results show that we can simulate the distance relay effectively and we can examine the operation of the distance relay very closely including debugging by using EMTP MODELS.

Development of an Item Selection Method for Test-Construction by using a Relationship Structure among Abilities

  • Kim, Sung-Ho;Jeong, Mi-Sook;Kim, Jung-Ran
    • Communications for Statistical Applications and Methods
    • /
    • v.8 no.1
    • /
    • pp.193-207
    • /
    • 2001
  • When designing a test set, we need to consider constraints on items that are deemed important by item developers or test specialists. The constraints are essentially on the components of the test domain or abilities relevant to a given test set. And so if the test domain could be represented in a more refined form, test construction would be made in a more efficient way. We assume that relationships among task abilities are representable by a causal model and that the item response theory (IRT) is not fully available for them. In such a case we can not apply traditional item selection methods that are based on the IRT. In this paper, we use entropy as an uncertainty measure for making inferences on task abilities and developed an optimal item selection algorithm which reduces most the entropy of task abilities when items are selected from an item pool.

  • PDF

Large scale fire test on a composite slim-floor system

  • Bailey, C.G.
    • Steel and Composite Structures
    • /
    • v.3 no.3
    • /
    • pp.153-168
    • /
    • 2003
  • This paper discusses the results and observations from a large-scale fire test conducted on a slim floor system, comprising asymmetric beams, rectangular hollow section beams and a composite floor slab. The structure was subjected to a fire where the fire load (combustible material) was higher that that found in typical office buildings and the ventilation area was artificially controlled during the test. Although the fire behaviour was not realistic it was designed to follow as closely as possible the time-temperature response used in standard fire tests, which are used to assess individual structural members and forms the bases of current fire design methods. The presented test results are limited, due to the malfunction of the instrumentation measuring the atmosphere and member temperatures. The lack of test data hinders the presentation of definitive conclusions. However, the available data, together with observations from the test, provides for the first time a useful insight into the behaviour of the slim floor system in its entirety. Analysis of the test results show that the behaviour of the beam-to-column connections had a significant impact on the overall structural response of the system, particularly when the end-plate of one of the connections fractured, during the fire.

Effect of Dune Sand on the Properties of Flowing Sand-Concrete (FSC)

  • Bouziani, Tayeb;Bederina, Madani;Hadjoudja, Mourad
    • International Journal of Concrete Structures and Materials
    • /
    • v.6 no.1
    • /
    • pp.59-64
    • /
    • 2012
  • Sand-concrete is being researched for potential usage in construction in Saharan regions of Algeria, because of shortage in coarse aggregate resources. This research work deals with the effect of dune sand, available in huge quantities in these regions, on the properties of flowing sand-concrete (FSC) prepared with different proportions of dune and river sands. Mini-cone slump test, v-funnel flow-time test and viscosity measurements were used to characterize the behaviour of FSC in fresh state. The 28-day compressive strength was also determined. Test results show that an optimal content of dune sand, which makes satisfied fresh and hardened properties of FSC, is obtained. Moreover, the obtained flow index (constant b) calculated by the help of power-law viscosity model is successfully correlated to the experimental results of v-funnel flow time.

Development of Vision Technology for the Test of Soldering and Pattern Recognition of Camera Back Cover (카메라 Back Cover의 형상인식 및 납땜 검사용 Vision 기술 개발)

  • 장영희
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1999.10a
    • /
    • pp.119-124
    • /
    • 1999
  • This paper presents new approach to technology pattern recognition of camera back cover and test of soldering. In real-time implementing of pattern recognition camera back cover and test of soldering, the MVB-03 vision board has been used. Image can be captured from standard CCD monochrome camera in resolutions up to 640$\times$480 pixels. Various options re available for color cameras, a synchronous camera reset, and linescan cameras. Image processing os performed using Texas Instruments TMS320C31 digital signal processors. Image display is via a standard composite video monitor and supports non-destructive color overlay. System processing is possible using c30 machine code. Application software can be written in Borland C++ or Visual C++

  • PDF

A Study on the Prediction for the Performance and the Size of the Vehicle Radiator (자동차 엔진 방열기의 뱅각 성능 및 방열 면적 예측에 관한 연구)

  • 박찬국;이종범;엄호룡;정우인
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.3
    • /
    • pp.117-127
    • /
    • 1997
  • To maintain the reasonable temperature in the engine is very important to keep the steady combustion state of engine and to prevent increasing of lubricant consump- tion, deteriorating of lubricant, shortening of the life time of engine and decreasing of material strength. The method of energy balance for devided elements of radiator is considered to analyse the performance of radiator. Th data of engine test and vehicle cooling tunnel test are applied to program for calculation of radiator outlet temperature, and this result is compared with outlet temperature of vehicle cooling tunnel test. As a result, the radiator outlet temperature by numerical analysis agrees well with that by experiment. It is concluded that this simulation program is available in developing the cooling system for a new car.

  • PDF

Development of the slitting device on separation study of pellet and hull (펠릿과 헐의 분리 연구를 위한 슬리팅 장치 개발)

  • 정재후;윤지섭;홍동희;김영환;진재현;박기용
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2003.05a
    • /
    • pp.236-239
    • /
    • 2003
  • The spent fuel slitting device is an equipment developed in order to feed UO$_2$pellet to the dry pulverizing/mixing device. In this study, we have compared and analyzed the handling method of the slitting and that of the pellet and hull, processing time, separating time for 20kgHM, the number of blades, on the existing slitting device using in DUPIC, and spent fuel management technology research and test facility. Also, we have compared and analyzed about an advantage and weak point, designing and producing, processing, establishment, operation, maintenance about the vertical and horizontal slitting device. Based on these results, we have developed the vertical slitting device. By using the results, we have enhanced the slitting processing time(over 40%)in comparison with DUPIC device, and it will is effectively applied to available data for designing and producing of the hot test facility.

  • PDF

Strength Evaluation and Life Prediction of the Multistage Degraded Materials (다단계 모의 열화재의 재료강도 평가와 수명예측)

  • 권재도;진영준;장순식
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.9
    • /
    • pp.2271-2279
    • /
    • 1993
  • In the case of life prediction on the structures and machines after long service, it is natural to consider a degradation problems. Most of degradation data form practical structures are isolated data obtained at the time of periodical inspection or repair. From such data, it may be difficult to obtain the degradation curve available and necessary for life prediction. In this paper, for the purpose of obtaining a degradation curves, developed the simulate degradation method and fatigue test and Charpy impact test were conducted on the degraded, simulate degraded and recovered materials. Fatigue life prediction were conducted by using the relationship between fracture transition temperature (DBTT : vTrs) obtained from the Charpy impact test through the degradation process and fatigue crack growth constants of m and C obtained from the fatigue test.

Urease를 이용한 위점막 시료에서 Helicobacter pylori의 신속한 진단법

  • Lee, Hak-Seong;No, Im-Hwan;Choe, Tae-Bu;Lee, Jong-Hwa
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.11a
    • /
    • pp.264-265
    • /
    • 2000
  • Helicobacter pylori(H. pylori) is the causative agent of chronic gastritis and the single most important factor in peptic ulcer disease, however, the pathogenetic mechanisms underlying H, pylori infection are not well understood. Futhermore, there is a strong association between H. pylori infection and gastric cancer. Various diagnostic methods for detecting H. pylori infection are available. These can be divided into invasive methods, requiring endoscopy, and non-invasive tests, mainly 13C-urea breath tests and serologic detection of antibodies. Rapid urease test is the most recommendable endoscopic test for the diagnosis of H. pylori infection, presently. CLO test kit is the represent of rapid urease test kits. The principles of CLO test kit is that hydrolysis of urea by urease Is detected by a dye indicators showing a color change. Our device is used same principle but we improved the reaction time is more faster and positive color change is more distinctive from the color of the negative specimen. So, this kit is more reliable because it response faster and accuracy.

  • PDF