• Title/Summary/Keyword: Auxiliary power system

Search Result 423, Processing Time 0.035 seconds

A Development of Energency Power Automatic Transfer Module in home (가정용 비상 전원 절체 모듈 개발)

  • Joo, Nam-Kyu;Kim, Kwan-Yuong;Kim, Nam-Ho;Lee, Jong-Myong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.321-323
    • /
    • 2009
  • When power failure occurs at multi-housing complex, auxiliary generator or emergency generator starts to provide power to households. This power is connected to emergency power ELB(Earth Leakage Breaker) at home distribution panel board and supplies power only for emergency light in living room but for heating system, refrigerator and other inevitable apparatuses that are in need of uninterruptible power. Since those domestic appliance are fed from common power line, they are inoperable during power failure. Our research is to resolve this problem by developing compatible relay-drive common/emergency-power ATS (automatic transfer switch) for home distribution panel board. In case of power failure, it transfers automatically and commences to provide power from emergency generator. Through this, Consumers can reach satisfaction where common power loads operate without any problem under both ordinary and power failure condition.

  • PDF

New Double-Connected Multi-Step Inverter for SVC Applications (SVC적용을 위한 새로운 이중접속방식의 멀티스텝 인버터)

  • 양승욱;최세완;문건우;조정구
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.6
    • /
    • pp.547-553
    • /
    • 1999
  • A new multi-step voltage source inverter is proposed in this paper. The proposed scheme is composed of t the double-connected 12-step inverter with an auxiliary circuit. The auxiliary circuit includes two voltage d dividing capacitors, two switching devices and a low KV A autotransformer. The resultant system is shown to b be a 24-step inverter suitable for medium power level SVC applications in which the PWM method can not be e employed. A 36-step operation can also be 이)tained by the addition of a bidirectional switch to the ProlXlsed I inverter. The design parameters are derived from the analysis of voltages and currents by means of switching f functions. The validity of the proposed scheme is confirmed by the simulated and experimental results.

  • PDF

Common-Mode Voltage Elimination with an Auxiliary Half-Bridge Circuit for Five-Level Active NPC Inverters

  • Le, Quoc Anh;Park, Do-Hyeon;Lee, Dong-Choon
    • Journal of Power Electronics
    • /
    • v.17 no.4
    • /
    • pp.923-932
    • /
    • 2017
  • This paper proposes a novel scheme which can compensate the common-mode voltage (CMV) for five-level active neutralpoint clamped (5L-ANPC) inverters, which is based on modifying the space vector pulse width modulation (SVPWM) and adding an auxiliary leg to the inverter. For the modified SVPWM, only the 55 voltage vectors producing low CMV values among the 125 possible voltage vectors are utilized, which varies over the three voltage levels of $-V_{dc}/12$, 0 V, and $V_{dc}/12$. In addition, the compensating voltage, which is injected into the 5L-ANPC inverter system to cancel the remaining CVM through a common-mode transformer (CMT) is generated by the additional NPC leg. By the proposed method, the CMV of the inverter is fully eliminated, while the utilization of the DC-link voltage is not decreased at all. Furthermore, all of the DC-link and flying capacitor voltages of the inverter are well controlled. Simulation and experimental results have verified the validity of the proposed scheme.

Study of DCM Interleaved Boost PFC Converter without the Detection of the Inductor Current (인덕터 전류검출이 필요없는 불연속모드 인터리브드 PFC 부스트 컨버터의 연구)

  • La, Jae-Du
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.4
    • /
    • pp.303-308
    • /
    • 2016
  • A light-emitting diode (LED) has been increasingly applied to various industrial fields and general lightings because of its high efficiency, low power consumption, environment-friendly characteristic and long lifetime. To drive this LED lighting, various types of power converters have been applied. Also, power factor correction (PFC) techniques play an important role in the power supply technology. In this paper, design and control of a DCM interleaved boost PFC converter is discussed. The proposed converter can reduce current ripples at input and output side by cancelling an each phase of inductor currents. Since the IC does not require the auxiliary winding of inductor for current detection, simple PFC circuit is achieved. Therefore, it contributes to increase efficiency and downsize the whole system volume, cost. Also, the performance of the proposed system is demonstrated through experiments.

MPPT Method of Grid-connected Photovoltaic Inverter (계통연계형인버터의 태양광발전시스템의 최대출력 제어법)

  • Kim, Ki-Hyun;Yu, Gwon-Jong;Jung, Young-Seok;Kim, Young-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1293-1295
    • /
    • 2001
  • Recently, according to developing industry and life style, power consumption have been increased year after year. Currently these much power demand from power consumer weakening the allowable power reverse margin in summer. As on of the remedies about this problem, the small scale grid-connected photovoltaic system is considered for auxiliary power source. Generally, grid-connected inverter have a isolation transformer for electrical isolation from utility. This paper proposed transformerless system topology an inquiry validity simulation.

  • PDF

Analysis of the FuelCell Battery Hybrid Power System (연료전지 축전지 복합 동력원의 구동 특성)

  • Lee, Bong-Do;Shin, Dong-Ryul
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1322-1324
    • /
    • 2001
  • FuelCell/Battery hybrid power systems were studied to develop high efficient zero-emission fuel cell electric vehicles. Fuel cells were used as an auxiliary energy source and batteries were used as a transient power source. The fuel cell system is used to supply the average power demand. Dynamic response of the hybrid systems was simulated using PSPICE program and also tested experimentally. The results can be used to design the interface module and to determine the power requirement between the fuel cell unit and the battery pack.

  • PDF

Load Analysis of the FuelCell/Battery Hybrid Power System (연료전지 축전지 하이브리드 동력원의 접속 특성 분석)

  • Lee, Bong-Do;Lee, Won-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.3081-3083
    • /
    • 2000
  • Fuel cell/battery hybrid power systems were studied to develop high efficient zero-emission fuel cell electric vehicles, Fuel cells were used as an auxiliary energy source and batteries were used as a transient power source. The fuel cell system is used to supply the average power demand. Dynamic response of the hybrid systems was simulated using PSPICE program and also tested experimentally, The results can be used to design the interface module and to determine the power requirement between the fuel cell unit and the battery pack.

  • PDF

AuxiliaryPower Device of Spontaneous starting for Railway Vehicle when electric overdischarge or an impossibility of being supplied with control power (밧데리 방전 및 제어 전원 수전불가시 자생기동 가능한 전동차용 보조전원장치)

  • Jeong Soon-You;Kim Sang-Kyun;Lee Hyun-Seok;Lee Kyung-Bok
    • Proceedings of the KSR Conference
    • /
    • 2003.05a
    • /
    • pp.548-553
    • /
    • 2003
  • Battery supplies Each Electric device in Railway vehicles with Control Power. When Battery is overchargedjustly, the battery voltage is not satisfied with the minimum operating voltage, CVCF Inverter(SIV) is supplied with external Power supply or the other railway vehicles and start up CVCF Inverter. In this paper to improve this problem, Dead battery Starter system is proposed. When the battery voltage is not satisfied with the minimum value.turn on the Dead Battery Starter switch, and the Dead Battery Starter supplies the control power to the SIV controller from the line voltage. With this Dead Battery Starter system, the train can be operated when the battery is not proper status. Dead Battery Starter is designed by ROTEM and will be delivered to Attiko Metro Series 2.

  • PDF

A Comparison of Distributed Optimal Power Flow Algorithm (최적조류계산 분산처리 기법의 비교)

  • Kim, Ho-Woong;Park, Marn-Guen;Kim, Bal-Ho;Kim, Jung-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1046-1048
    • /
    • 1999
  • This Paper compares two mathematical decomposition coordination methods to implementing the distributed optimal Power flow(OPF) using the regional decomposition: the Auxiliary Problem Principle(APP) and the Alternating Direction Method(ADM), a variant of the conventional Augmented Lagrangian approach. A case study was performed with IEEE 50-bus system.

  • PDF

A Study on Auxiliary Power Supply for Railway Vehicle adapted a LLC Resonant Converter (LLC 공진형 컨버터를 적용한 철도차량용 보조전원장치에 대한 연구)

  • Jone, Byoung Jeen
    • Proceedings of the KIPE Conference
    • /
    • 2018.11a
    • /
    • pp.161-162
    • /
    • 2018
  • 철도챠량에서 일반적으로 사용되는 상용전원은 보조전원장치(이하 SIV)로 불리는 전력변환장치로부터 공급된다. 본 논문에서는 LLC 공진형 컨버터를 적용하여 스위치의 영전압 스위칭(Zero-Voltage-Switching, ZVS)을 통해 높은 효율을 달성하고, 고속스위칭에 의해 인덕터, 커패시터, 트랜스포머와 같은 소자의 부피를 줄이고 시스템의 효율을 높여 기존의 보조전원장치보다 약 40%이상 소형 경량화가 가능한 보조전원장치에 대한 연구를 소개한다.

  • PDF