• Title/Summary/Keyword: Auxiliary phase

Search Result 288, Processing Time 0.029 seconds

Analysis and Improvement for Single 6/6 SRM with a Saturable Area (자기 포화 영역을 갖는 단상 6/6 SRM의 자기 구조 해석 및 개선)

  • Oh, Seok-Gyu
    • Journal of the Korean Magnetics Society
    • /
    • v.27 no.2
    • /
    • pp.70-75
    • /
    • 2017
  • Single-phase SRM is cost competitive because it can reduce the number of switches for small, low-cost applications. However, since the single-phase SRM is difficult to start itself, methods for realizing self-starting by using auxiliary magnet or auxiliary pole have been studied. Recently, a method of self-starting by changing the shape of the rotor with a saturable area has been proposed. The purpose of this paper is to analyze the magnetic structure of single phase 6/6 SRM with a saturable rotor and to improve the magnetic structure of rotor with a saturable area. For this magnetic analysis, FLUX2D, a finite element method analysis program, was used.

Single-Phase Improved Auxiliary Resonant Snubber Inverter that Reduces the Auxiliary Current and THD

  • Zhang, Hailin;Kou, Baoquan;Zhang, He;Zhang, Lu
    • Journal of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.1991-2004
    • /
    • 2016
  • An LC filter is required to reduce the output current ripple in the auxiliary resonant snubber inverter (ARSI) for high-performance applications. However, if the traditional control method is used in the ARSI with LC filter, then unnecessary current flows in the auxiliary circuit. In addressing this problem, a novel load-adaptive control that fully uses the filter inductor current ripple to realize the soft-switching of the main switches is proposed. Compared with the traditional control implemented in the ARSI with LC filter, the proposed control can reduce the required auxiliary current, contributing to higher efficiency and DC-link voltage utilization. In this study, the detailed circuit operation in the light load mode (LLM) and the heavy load mode (HLM) considering the inductor current ripple is described. The characteristics of the improved ARSI are expressed mathematically. A prototype with 200 kHz switching frequency, 80 V DC voltage, and 8 A maximum output current was developed to verify the effectiveness of the improved ARSI. The proposed ARSI was found to successfully operate in the LLM and HLM, achieving zero-voltage switching (ZVS) of the main switches and zero-current switching (ZCS) of the auxiliary switches from zero load to full load. The DC-link voltage utilization of the proposed control is 0.758, which is 0.022 higher than that of the traditional control. The peak efficiency is 91.75% at 8 A output current for the proposed control, higher than 89.73% for the traditional control. Meanwhile, the carrier harmonics is reduced from -44 dB to -66 dB through the addition of the LC filter.

Reduction of Harmonics and Compensation of Reactive Power about Wind Power Generation System Connected to Grid (계통 연계형 풍력발전 시스템의 고조파 저감 및 무효전력 보상)

  • Kim, Yeong-Min;Hwang, Jong-Sun;Kim, Jong-Man;Park, Hyun-Chul;Song, Seung-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.1093-1096
    • /
    • 2002
  • In this paper, a novel multi voltage inverter system is proposed for reductions of harmonics, which can compensate reactive power. At first, we remove capacitor at input side for reactive power compensation. Secondly, by adding DC voltage to the filter capacitor, it can control power factors as lead-phase according to alterations of loads at power reception. Thirdly, if winding and single phase-bridge inverter(auxiliary circuit) is installed to DC power for reduction of harmonic, waveform of output voltages become to 36-steps. Thus, SVC(static var compensator) systems which can reduce harmonics are designed.

  • PDF

Feasibility Study of Distributed Auxiliary Resonant Commutation Snubber Linked Three Phase Voltage Source ZVS Inverter with Digital Servo Control Implementation

  • Hiraki, E.;Hattori, H.;Nakaoka, M.;Horiuchi, T.;Sugawara, Y.
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.341-345
    • /
    • 1998
  • This paper presents performance and loss analysis of Auxiliary Resonant Commutation Snubber-linked (ARCS) three phase voltage source soft switching inverter which is operated under a condition of Zero Voltage Switching (ZVS). The system performances of this ARCS soft switching inverter which is controlled on optimal type I digital servo scheme are illustrated and evaluated on the basis of experimental results.

  • PDF

Performance analysis and Design of self-excited Induction Generators considering output voltage (출력 특성을 고려한 단상 자기여자 유도 발전기의 특성 해석)

  • Kim, Cherl-Jin;Lee, Kwan-Yong;Cho, Young-Rae;Baek, Soo-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2005.04a
    • /
    • pp.76-79
    • /
    • 2005
  • This paper describes the performance analysis and design of 1-phase self-excited induction generators. The minimum parallel capacitance of self-excited capacitor connected auxiliary winding and the series capacitance of regulating voltage capacitor connected main winding is proposed the suitable value using circuit equations of main and auxiliary winding. For the steady state analysis, the equivalent circuit of 1-phase induction generators is used as circuit modeling using the double-revolving field theory. The validity of designed generator system will be confirmed by experimental and computed results.

  • PDF

The study on comparison of soft-switching techniques for the improvement of efficiency in single phase-full bridge inverter (단상풀브릿지 인버터효율향상을 위한 소프트 스위칭 기법 비교에 관한 연구)

  • Lim, Sung-Hun;Lee, Seong-Ryoung;Han, Byung-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1215-1217
    • /
    • 2000
  • For the application of soft-switching technique to single Phase-full bridge inverter. in this paper ZCT(Zero Current Transition) and ZVT(Zero Voltage Transition) techniques proposed previously are compared and discussed the merit and demerit of both. Both have a excellency that can reduce the number of auxiliary switch and resonant circuit compared to other techniques and achive soft-switching in auxiliary switch itself. Therefore, it has enabled us to have benifits of realizing high efficiency and reliability, low EMI for high switching frequency and reducing the cost as well as size of device.

  • PDF

Speed Control Characteristics of Capacitor-Run Single Phase Induction Motor Using TRIAC (TRIAC을 이용한 커패시터 운전형 단상 유도전동기의 속도제어 특성)

  • Lee, Seung-Yong;Yoon, Duck-Yong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.9
    • /
    • pp.1283-1288
    • /
    • 2012
  • This paper presents speed control characteristics of capacitor-run SPIM(Single Phase Induction Motor) using TRIAC for comparing and analyzing four kinds of voltage control methods such as supply voltage control, main winding voltage control, auxiliary winding voltage control and auxiliary winding voltage control without starting capacitor. The computer simulations were performed using MATLAB Simulink to show control characteristics of four voltage control methods. And their control characteristics were conformed by experiments for capacitor-run 90W SPIM as a sample motor. The results of simulations and experiments show that supply voltage control method has fast dynamic response characteristics and main winding voltage control method has higher power efficiency and can be implemented at lower system cost.

Development of an Electronic Starter for Single Phase Induction Motor (단상 유도전동기의 전자식 기동장치 개발)

  • Jung, Hyeung-Woo;Baik, Won-Sik;Kim, Min-Huei;Kim, Dong-Hee;Park, Dong-Han
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.397-399
    • /
    • 2007
  • This paper presents a simple electronic starter for single phase induction motor (SPIM). It replaces the centrifugal switch in the auxiliary winding circuit of the capacitor start type SPIM. The centrifugal switch disconnects the auxiliary winding when the motor gets close to its rated speed. The presence of the centrifugal switch, with its possibly fluttering contacts, reduce reliability of SPIM. The operation principle of the proposed electronic starter is explained, and illustrated with experimental results.

  • PDF

On efficient estimation of population mean under non-response

  • Bhushan, Shashi;Pandey, Abhay Pratap
    • Communications for Statistical Applications and Methods
    • /
    • v.26 no.1
    • /
    • pp.11-25
    • /
    • 2019
  • The present paper utilizes auxiliary information to neutralize the effect of non-response for estimating the population mean. Improved ratio type estimators for population mean have been proposed and their properties are studied. These estimators are suggested for both single phase sampling and two phase sampling in presence of non-response. Empirical studies are conducted to validate the theoretical results and demonstrate the performance of the proposed estimators. The proposed estimators are shown to perform better than those used by Cochran (Sampling Techniques (3rd ed), John Wiley & Sons, 1977), Khare and Srivastava (In Proceedings-National Academy Science, India, Section A, 65, 195-203, 1995), Rao (Randomization Approach in Incomplete Data in Sample Surveys, Academic Press, 1983; Survey Methodology 12, 217-230, 1986), and Singh and Kumar (Australian & New Zealand Journal of Statistics, 50, 395-408, 2008; Statistical Papers, 51, 559-582, 2010) under the derived optimality condition. Suitable recommendations are put forward for survey practitioners.

Single phase induction motor driving system using auxiliary resonant DC-DC converter (보조 공진 DC-DC컨버터를 이용한 단상 유도 전동기 구동 시스템)

  • Lee, S.H.;Mun, S.P.;Kwon, S.K.;Lee, H.W.;Suh, K.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1190-1192
    • /
    • 2002
  • These days, electromagnetic radiation noise and switching losses of static converter become harmful. Many resonant inverters with radiation techniques solve their such problems. Auxiliary Resonant Commutated Pole Inverter (ARCP) was proposed. but it has two demerits. In circuit configuration. It isn't constructed by 2 in 1 IGET modules. Besides, control is complicated because of neutral point voltage control and boost current control. This paper proposes a new auxiliary resonant inverter which solved two demerits. In addition, it deals efficiency which compared with hard switching inverter and result of separation of power loss

  • PDF