• Title/Summary/Keyword: Auxiliary Air

Search Result 175, Processing Time 0.027 seconds

An Experimental Study on Catalytic Reformer with Direct Spraying of Fuel and Water for SOFC (고체산화물 연료전지용 연료.물 직접 분무식 촉매 개질기에 관한 실험적 연구)

  • Lee, Dae-Keun;Dong, Sang-Geun;Yang, Je-Bok;Kim, Hak-Joo;Jung, Heon
    • 한국연소학회:학술대회논문집
    • /
    • 2006.10a
    • /
    • pp.260-265
    • /
    • 2006
  • An experimental study on the catalytic reformer adopted in the auxiliary power unit system of solid oxide fuel cell was conducted. A 3-fluid nozzle, by which liquid fuel such as diesel, water and air are sprayed and uniformed mixed, was designed and used in this study. An electrically heated monolith inserted in the reformer was used for the vaporization of fuel and water in the transient state of reformer. The reformer uses the partial oxidizing reaction at the catalyst and the supply of water prevents the flame combustion in the spraying zone and lessens the deactivation of catalyst. The result showed that the reforming of liquid fuel can be started by the electrically heated monolith and the 3-fluid nozzle can give the uniform mixing of fuel, water and air. It was also found that the reformer fueled by n-hexadecane can make the reformate, at best, containing $H_2$ at 15.5% and CO at 11.5% that are used as fuel in the solid oxide fuel cell.

  • PDF

Case Study of Repair Works on Surge Suppression Device for Booster Pumping Station (가압펌프장의 수격완화설비에 대한 보수·보강 사례)

  • Kim, Sang-gyun;Lee, Dong-keun;Lee, Gye-bok;Kim, Kyung-yup
    • The KSFM Journal of Fluid Machinery
    • /
    • v.8 no.4 s.31
    • /
    • pp.20-26
    • /
    • 2005
  • When the pumps are started or stopped for the operation or tripped due to the power failure, the hydraulic transients occur as a result of the sudden change in velocity. The field tests on the waterhammer were carried out for Pangyo booster pumping station in which had six booster pumps and two in-line pumps with the motor of output 1,700 kW, respectively. The booster pumping station was equipped with the pump control valve as the main surge suppression device, and the surge relief valve as auxiliary one. But the pump control valve had not early controlled in the planned closing mode, the slamming occurred to the valve of which abruptly closed during the large reverse flow. Because the positive pressure wave caused by the pump failure was superposed on the slam surge, the upsurge increased so extremely that the pump control valve was damaged. After the air chambers were additionally installed in the booster pumping station, it was preyed that the water supply system acquire the safety and reliability on the pressure surge.

Waterhammer For In-line Booster Pump (직결식 펌프의 수격현상)

  • Kim, S C.;Lee, K. B.;Kim, K. Y.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.208-216
    • /
    • 2004
  • The waterhammer occured when the pumps are started or stopped for the operation or tripped due to the power failure, the hydraulic transients occur as a result of the sudden change in velocity. The field tests of the waterhammer were carried out for PanGyo booster pumping station. The PanGyo pumuing station was installed booster pump of 6 sets and in-line pump of 2 sets. The main surge suppression device was equipped with the pump control valve and the surge relief valve as auxiliary. However, the pump control valve had not early controlled in the planned closing mode, and the slamming occurred to the valve of which abruptly closed during the large reverse flow. Because the pressure wave caused by the pump failure was superposed on the slam surge, the upsurge increased so extremely that the shaft of the valve was damaged. After the addition surge suppression device was equipped with air chamber. Further more in-line pump is needed surge suppression device that the pumping station acquired the safety and reliability for the pressure surge.

  • PDF

Performance Analysis of a Gas Turbine for IGCC Considering Plant Configuration (플랜트의 구성을 고려한 IGCC용 가스터빈의 성능해석)

  • Kim, Young-Sik;Lee, Jong-Jun;Kim, Tong-Seop;Sohn, Jeong-Lak;Joo, Yong-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.9
    • /
    • pp.704-711
    • /
    • 2008
  • Integrated gasification combined cycle (IGCC) is an environment friendly method of using coal. Several commercial IGCC plants have been built worldwide during the past decade, and a domestic development project has also been launched recently. Operation and performance characteristics of a gas turbine in the IGCC plant deviates from those of original gas turbines due to several factors such as increased amount of fuel supply and integration with other components. In this study, performance of a gas turbine in the IGCC plant is analyzed considering its integration with the air separation unit (ASU). Influence of the degree of integration (split of air supplies to ASU from the auxiliary compressor and the gas turbine compressor) on the system performance is investigated. In addition, effect of modulating nitrogen return flow from the gasifier to the gas turbine on the operating characteristics of the gas turbine is examined.

Comparison Between Two Solar Absorption Cooling System Using Single Effect and Single Effect/Double Lift Cycle (일중효용 사이클과 일중효용/2단승온 사이클을 이용한 태양열 흡수식 냉방시스템의 비교)

  • 정시영;이상수;조광운;백남춘
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.3
    • /
    • pp.267-276
    • /
    • 2000
  • A numerical study has been carried out to find out the optimal design condition of a solar absorption cooling system. The system was composed of solar collectors and an absorption chiller with LiBr/water The System performance with commercial single effect(SE) cycle and a new single effect/double lift(SE/DL) cycle utilizing low temperature hot water was calculated and compared. It was found that the required solar collector area grew exponentially as the overall heat loss coefficient of solar collectors increased. For instance, the required area for cooling capacity of 1 USRT was $17m^2$ if heat loss coefficient was 4 W/$m^2\;cdot\;K$. If heat loss coefficient was doubled($8\;W/m^2\;cdot\;$K), the required collector area was increased by 6 times($100m^2$) .It was also found that the SE-cycle as the heat loss coefficient of solar collectors increased. Generally, a SE/DL-cycle seems to be more advantageous than a SE-cycle if loss coefficient of solar collector is greater than 4 W/$m^2\;cdot\;K$.

  • PDF

Analysis of the Emission Benefits of Using Alternative Maritime Power (AMP) for Ships

  • Kim, Kyunghwa;Roh, Gilltae;Chun, Kangwoo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.3
    • /
    • pp.381-394
    • /
    • 2019
  • The marine industry contributes a large proportion of the air pollutant emissions along coastal regions, and this air pollution has been strongly linked to cardiovascular diseases and other illnesses. To alleviate the problem, many ports have installed alternative maritime power (AMP) facilities that enable onboard marine auxiliary engines with generators (gensets) to be shut down while a ship is at berth. This study compared the emissions from conventional gensets with those from AMP facilities, focusing on four emission types: greenhouse gases (GHG), sulphur oxides (SOX), nitrogen oxides (NOX), and particulate matter (PM). Both direct (combustion / operation) and indirect (upstream) emissions were considered together for the emission comparison. The results showed that AMP has lower emissions than conventional onboard gensets, and this benefit is highly dependent on the electricity generation mix onshore. On average, GHG emissions could be reduced by about 18.3 %, while the other emissions (SOX, NOX, and PM) would decrease more dramatically (88.4 %, 90.1 %, and 91.5 %, respectively). Additionally, future benefits of the AMP would increase due to the expansion of renewable energies. Thus, this study supports the potential of AMP as a promising solution for environmental concerns at ports worldwide.

A Study on the liquid Type Solar Heating System (액체식 태양열난방계통에 관한 연구)

  • Nam, Pyong-Woo
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.8 no.4
    • /
    • pp.221-236
    • /
    • 1979
  • The three years Performance of a liquid type solar heating system has been determined for a system which has been determined for a system which has been operating continuously since 1976 in Seoul with no serious maintenance. A flat plate collector is used to transform incident solar radiation into thermal energy. This energy is stored if the form of sensible energy and used as needed to supply the space heating loads. An electric auxiliary heaters are provided to supply energy for space heating load when the energy in the storage tank is depleted. The ratio of useful collected solar heat divided by the total solar radiation on the collector was obtained about 84 per cent. It is also obtained the relation between ratio of solar collector area to the heating area and the ratio of useful collected solar energy to the heating load for the useful design data. A comparison between the measured and simulated results with the solar space heating system is described. Hour by hour simulation is made on unsteady state basis using the system parameters and meteorological data at the experiment site. The result of comparison turned out satisfactory for the solar heating system, though the simulation was formed somewhat higher than by experimental.

  • PDF

Research on Technical Trends of IGBT Gate Driver Unit for Railway Car (철도차량용 IGBT Gate Driver Unit 기술 동향 분석 연구)

  • Cho, In-Ho;Lee, Jae-Bum;Jung, Shin-Myung;Lee, Byoung-Hee
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.3
    • /
    • pp.339-348
    • /
    • 2017
  • Power supply for railway cars can be divided into propulsion system power supply and auxiliary power units (APU). The propulsion system power supply is for propulsion of railway cars, and regenerative braking; the APU provides power for the air compressor, lighting, car control and other auxiliary parts. According to high voltage and high current specifications, generally, an insulated-gate bipolar transistor (IGBT) is adopted for the switching component. For appropriate switching operation, a gate driver unit (GDU) is essentially required. In this paper, the technical trends of GDU for railway cars are analyzed and a design consideration for IGBT GDU is described.

Characteristic Analysis for the Reduction Detent Force of Double-sided Slotted Type Permanent Magnet Linear Generator for Wave Energy Conversion (파력에너지 변환용 양측식 슬롯티드 타입 선형 발전기의 디텐트력 저감을 위한 특성해석)

  • Seo, Sung-Won;Choi, Jang-Young;Koo, Min-Mo;Park, Hyung-Il;Hong, Keyyong;Kim, Kyong-Hwan
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.1
    • /
    • pp.31-37
    • /
    • 2016
  • This study considered the reduction of the detent force of a permanent magnet linear synchronous generator (PMLSG). The PMLSG has a relatively large magnetic air gap. Thus, a slotted type of stator structure is generally employed. Furthermore, the detent force, which is caused by energy imbalances owing to the interaction between tooth-slot structures and the permanent magnets (PMs), must be minimized for start-up operation. Therefore, in this paper, the methods of auxiliary teeth and a notch in the teeth are applied to reduce the detent force.

A Study on the Size and the Shape Optimization of Cross Beam for Electric Vehicle using GENESIS 7.0 (GENESIS 7.0을 이용한 전동차용 크로스 빔의 치수와 형상 최적화에 관한 연구)

  • 전형용
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.11
    • /
    • pp.129-136
    • /
    • 2002
  • Electric vehicle body has to be subjected to uniform load and demand auxiliary equipment such as air pipe, electric wire pipe and gas pipe. Especially, lightweight vehicle body is salutary to save operating costs and fuel consumption. Cross beam supports the weight of passenger and electrical equipments and account for the most of weight of vehicle body. Therefore this study performs the size and the shape optimization of crossbeam for electric vehicle using GENESIS 7.0 and presents the effect of mass reduction and the shape of hole in cross beam.