• Title/Summary/Keyword: Autonomic Nervous Response

Search Result 96, Processing Time 0.032 seconds

Cholinergic Contraction to the Perivascular Nerve Stimulation on the Isolated Coronary Artery of Pig (돼지 적출 심장 관상동맥에 있어서 Perivascular Nerve Stimulation에 의한 Cholinergic 수축 작용)

  • Lee, Han-Ki;Goo, Bong-Oh;Moon, Sang-Eun;Shim, Chul-Soo
    • The Journal of Korean Physical Therapy
    • /
    • v.13 no.1
    • /
    • pp.61-71
    • /
    • 2001
  • The purpose oi this study is to identify clearly the physiologic significance of autonomic nervous system. This study is to find the loose of endogenous neurotransmitter while using the neural response of the neural excitatory action which is distributed to the perivascular smooth muscle through the electrical stimulation of the smooth muscle of coronary artery of pig. The effects of perivascular nerve stimulation were investigated on isolated coronary artery of pig.1 . The magnitude of contractile response to perivascular nerve stimulation increased with increasing frequency (2-80 Hz) of stimulation. 2. The contractions to perivascular nerve stimulation(40V, 40Hz. 0.5msec, 1 min) were increased greatly by pretreatment of the cholinestrase inhibitor physostigmine. 3. The contraction to perivascular nerve stimulation(40V,40Hz, 0.5msec, 1min) was antagonised markedly by the muscarinic antagonist atropine. 4. The contraction to perivascular nerve stimulation(40V, 40Hz, 0.5msec, 1 min) was blocked by the neural blocker tetrodotoxin. 5. The contractions to perivascular nerve stimulation(40V. 40Hz, 0.5msec, 1 min) were not affected significantly by the -adrenergic antagonist phentolamine or - adrenergic antagonist propranolol. 6. The contractile response by the acetylcholine was increased by the pretreatment of cholinestrase inhibitor physostigmine. The finding suggest that it is powerful excitatory action linked to muscarinic receptor by cholinergic nerve in coronary artery of pig.

  • PDF

Design of Oriental Medicine diagnosis system by Bio-Electric Response (생체-전기적 반응에 의한 한의학적 진단시스템의 설계)

  • 이용흠;장근중;박창규
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.2
    • /
    • pp.420-429
    • /
    • 2004
  • It has been needed diagnosis technology of the EFG(Electro Functio Gram) measurement concept which is incorporated characteristic of modern science and biomedical engineering, because function abnormality diagnosis can't diagnose with visualization instruments or clinical pathology. The general diagnosis system(EFG system) has been developed to use basic diagnosis instrument that has reappearance, reliance and convenience using the functio diagnosis technology, in the field of western/oriental medicine. Also, we improved sticking electrode and simultaneous measurement method of the limbs 8CH, head 2CH to diagnose body circulation of Qi and acupoints for Oriental Medicine diagnosis/therapy. The result of clinical for adult man 20 persons, the EFG system can diagnose state of 12 meridians and autonomic nervous system. Therefore, in this paper, we designed of oriental medicine diagnosis system by bio-electric response with materialized H/W and S/W for 12 meridians state diagnosis of human body and system construction of the EFG.

The Masking Effect According in Olfactory Stimulus on Horns Stimulus While Driving in Graphic Driving Simulator (화상 자동차 시뮬레이터에서 운전 중에 경적음 자극에 대한 후각자극의 마스킹 효과)

  • Min, Cheol-Kee;Ji, Doo-Hwan;Ko, Bok-Soo;Kim, Jin-Soo;Lee, Dong-Hyung;Ryu, Tae-Beum;Shin, Moon-Soo;Chung, Soon-Cheol;Min, Byung-Chan;Kang, Jin-Kyu
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.35 no.4
    • /
    • pp.227-234
    • /
    • 2012
  • In this study, the masking effect of olfactory stimulus on the awakening state due to sound stimuli while driving using Graphic Driving Simulator was observed through the response of autonomic nervous system. The test was conducted for 11 males in their twenties. The siren of ambulance car was presented to them as auditory stimulus for 30 secs while driving in a situation of high way in the condition of both peppermint and control, respectively, and LF/HF ratio of HRV (Heart Rate Variability), the activity index of sympathetic nerve, and GSR (Galvanic Skin Response) response were examined. The test was proceeded in the order of three stages, that is, sound stimuli (test 1), driving performance, and sound stimuli (test 2), and fragrance stimulus, driving performance, and sound stimuli (test 3), and the physiological signal of GSR, HRV was measured in the whole stages. As a result of test, comparing the results of before and after auditory stimulus test (1) (p < 0.01), test (2) (p < 0.05), and test (3) (p < 0.01), driving performance test (2) (p < 0.01), test (3) (p < 0.01), and olfactory stimulus test (3) (p < 0.05), respectively, GSR response increased, showing significant difference in all the tests. It indicates that when auditory stimulus was presented to the subjects, they were in the awakening state as sympathetic nervous system got activated. As a result of comparing auditory stimulus while driving before and after presenting olfactory stimulus, there was no significant difference in GSR response. The LF/HF ratio of HRV increased, showing a significant difference only in test (2) (p < 0.05), and in driving performance test (2) (p < 0.05) in auditory stimulus, however, it showed no significant difference in olfactory stimulus. As a result of comparing auditory stimulus while driving before and after presenting olfactory stimulus, there was a decrease, showing significant difference (p < 0.05) in LF/HF ratio of HRV. That is, it means that the activation of sympathetic nervous system decreased, and that parasympathetic nervous system got activated. From these results, it was observed that while driving, the awakening level due to auditory stimulus was settled with olfactory stimulus. In conclusion, it was drawn that while driving, olfactory stimulus could have the masking effect on auditory stimulus.

Research on the Thermal Comfort Heating Mode Considering Psychological and Physiological Response of Automobile Drivers (운전자의 심리·생리 반응을 고려한 승용차 쾌적 난방 모드에 관한 연구)

  • Kim, Min Soo;Kum, Jong Soo;Park, Jong Il;Kim, Dong Gyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.30 no.3
    • /
    • pp.149-157
    • /
    • 2018
  • In this research, the psychological and physiological reactions of the driver were measured during winter to evaluate thermal comfort. The experiment was conducted using 3 different cases which are hot air heating, warm-wire seat heating and hot air & warm-wire seat heater operating simultaneously. With regard to psychological reaction, the warm-wire heating mode was the most preferred. The reason is that it is dry in other cases. With regard to EEG response, thermal comfort increased by 37% in warm air mode heating. In addition, when the warm-wire heating mode and the hot air & warm-wire heating mode were simultaneously operated, the thermal comfort continuously increased by between 17% and 20% for 20 minutes after boarding. Under the change of the autonomic nervous system, the thermal stress level increased by 23% after 15 minutes on board in the hot air heating mode and decreased continuously by 13% during the warm-wire seat heating mode. We recommended the hot air heating mode is only used for a short time to raise the inside temperature during the early boarding period and that warm-wire seat heating mode be actively utilized.

Response Characteristics of Perceived Stress Response Inventory in Patients with Upper Gastrointestinal Disorder (상부 위장관 장애 환자에서의 스트레스반응 지각척도의 반응특성)

  • Suh, Yong-Woo;Cho, In-Hee;Shin, Kwang-Chel;Chung, Yong-Kyoon
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.8 no.2
    • /
    • pp.172-180
    • /
    • 2000
  • Objectives : We investigated the characteristics of perceived stress response and relationship between some variables of gastrointestinal symptoms(esp., dyspepsia) and subscales of perceived stress response inventory(PSRI) in patients with upper gastointestinal disorder when they perceived stress. Methods : 84 patients with upper gastrointestinal disorder(gastritis, gastric ulcer, duodenal ulcer etc.) and 94 normal controls completed the PSRI developed by Korean psychiatrists. The patient group performed the questionnaire including some variables of gastrointestinal symptoms. Results : Internal consistency was statistically significant in all subscales of PSRI. The patient group was significantly higher at total score of PSRI, general somatic symptom subscale score, specific somatic symptom score than control group. As the result of stepwise regression analysis for relationship between some variables of gastrointestinal symptoms ans subscales of PSRI, specific somatic symptom subsclae closely related with illness duration, past illness history and severity of symptom, and the lowered cognitive function & general negative thinking subscale related with the existence of emotional distress. Conclusion : Patients with upper gastrointestinal disorder showed stronger perceived stress response than control group and they experiences somatic symptoms related to autonomic nervous system and/or gastrointestinal symtoms rather than emotional, cognitive, behavioral symtoms when they perceived stress. They also responded to stress as they expeirenced specific somatic symtom when they had long illness duration, past illness history, and high severity of symptom and the existence of emotional distress could develop lowered congnitive function and general negative thinking.

  • PDF

Application of Near-Infrared Spectroscopy in Neurological Disorders: Especially in Orthostatic Intolerance (신경계 질환에서 근적외선분광분석법의 적용: 기립불내증을 중심으로)

  • Kim, Yoo Hwan;Paik, Seung-ho;Phillips V, Zephaniah;Seok, Hung Youl;Jeon, Nam-Joon;Kim, Beop-Min;Kim, Byung-Jo
    • Journal of the Korean neurological association
    • /
    • v.35 no.1
    • /
    • pp.8-15
    • /
    • 2017
  • Near-infrared spectroscopy (NIRS), a noninvasive optical method, utilizes the characteristic absorption spectra of hemoglobin in the near-infrared range to provide information on cerebral hemodynamic changes in various clinical situations. NIRS monitoring have been used mainly to detect reduced perfusion of the brain during orthostatic stress for three common forms of orthostatic intolerance (OI); orthostatic hypotension, neurally mediated syncope, and postural orthostatic tachycardia syndrome. Autonomic function testing is an important diagnostic test to assess their autonomic nervous systems for patients with symptom of OI. However, these techniques cannot measure dynamic changes in cerebral blood flow. There are many experimentations about study of NIRS to reveal the pathophysiology of patients with OI. Research using NIRS in other neurologic diseases (stroke, epilepsy and migraine) are ongoing. NIRS have been experimentally used in all stages of stroke and may complement the established diagnostic and monitoring tools. NIRS also provide pathophysiological approach during rehabilitation and secondary prevention of stroke. The hemodynamic response to seizure has long been a topic for discussion in association with the neuronal damage resulting from convulsion. One critical issue when unpredictable events are to be detected is how continuous NIRS data are analyzed. Besides, NIRS studies targeting pathophysiological aspects of migraine may contribute to a deeper understanding of mechanisms relating to aura of migraine. NIRS monitoring may play an important role to trend regional hemodynamic distribution of flow in real time and also highlights the pathophysiology and management of not only patients with OI symptoms but also those with various neurologic diseases.

The Study of Cognitive Function and EEG Spectrum Difference between Allergic Rhinitis and Normal Children (뇌파측정을 이용한 비염 환아와 정상아의 주의집중력에 관한 연구)

  • Lee, Nam-Yeol;Kim, Yun-Hee;Han, Jae-Kyung
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.21 no.2
    • /
    • pp.1-12
    • /
    • 2007
  • Objectives : Allergic children have known to have multiple behavior problems. Among them, attentional ability disorder is one of the most common problems. This study is to examine relationship between learning ability and allergic rhinitis by analyzing EEG status of children. Methods : We analyzed cognitive functions of two different children groups; 21 children with allergic rhinitis and 19 normal children with CANS 3000(Central & Autonomic Nervous System, LAXTHA Inc., Korea), cognitive functions assessment program by EEG. Results : 1. According to mean active EEG rhythm of Theta, Alpha, SMR, M-beta, there were no significant difference between allergic rhinitis and the normal group. 2. According to mean active EEG rhythm of right H-beta, Gamma wave allergic rhinitis group's value was significantly higher than that of the normal group. 3. According to mean cognitive strength, response, concentration, left / right brain activity and learning ability score, there were no significant difference between allergic rhinitis and the normal group. 4. According to mean workload score, allergic rhinitis group's value was significantly higher than that of the normal group. Conclusions : It is likely that allergic rhinitis group, which showed relatively high frequency EEG rhythm, is more fragile to stress and less active on mental processing. Along side with physical examination, psychological assessment should also be conjugated on treating children with allergic rhinitis.

  • PDF

A double-blind placebo-controlled heart rate variability investigation to evaluate the quantitative effects of the organic nanoscale aeon patch on the autonomic nervous system

  • Nazeran, Homer
    • CELLMED
    • /
    • v.5 no.1
    • /
    • pp.5.1-5.5
    • /
    • 2015
  • In this first double-blind-placebo-controlled investigation of the Aeon Patch, electrocardiographic data were acquired from 50 well-hydrated volunteers [21 females and 29 males, age: 19-79, weight: 117-334 lbs, height: 5'-6',3"], under 3 different conditions for a total duration of 15 min (5 min/condition). Condition1: Control (C) - while wearing no Patch, Condition 2: Placebo (P) or Active (A) - after wearing either the Placebo or the Aeon Patch for 20 min, and Condition 3: Active (A) or Placebo (P) - after wearing either the Aeon or the Placebo Patch for 20 min. There was a washout period of 15 min between Conditions 2 and 3. All involved in the investigation were blind to the (A) and (P) Patches as they looked exactly the same and were assigned in a random fashion. The hypothesis to be tested was: Wearing the Aeon Patch for 20 min reduces stress. Data were first quality assured and those subjects who showed a parasympathetic response after wearing the Patch within 20 min were identified as early responders. Thirty subjects (60%) achieved a relaxed state after wearing the Aeon Patch as early as 20 min. Statistical analysis (one-sample inference) was used to compare the spectral features of the responders. The normalized LF/HF decreased significantly ($24%{\pm}9%$ after 20 min) in condition (A) compared to condition (P) with a p-value < 0.047 (n = 30) in responders. Therefore, the hypothesis that wearing the Aeon Patch for 20 min reduces stress was accepted as true.

A Study on Evaluation of Human Arousal Level using PPG Analysis (PPG(Photoplethysmography)분석을 이용한 각성도 평가에 관한 연구)

  • Kim, Chi-Jung;Whang, Min-Cheol;Kim, Jong-Hwa;Woo, Jin-Cheol;Kim, Yong-Woo;Kim, Ji-Hye
    • Journal of the Ergonomics Society of Korea
    • /
    • v.29 no.1
    • /
    • pp.113-120
    • /
    • 2010
  • This research is to evaluate the arousal level by using cardiovascular response. PPG was used in this study as one of the method of measuring it rather than ECG (Electrocardiography) for the purpose of solving ergonomic problem of sensing. The participants were in the age group of 20 (mean=24, standard deviation=1.25): five men and five women. Each experiment composed with four identical sets. First, a black screen was displayed for 30 second rest. Then, the prepared 6 pair images were randomly presented for 10 second stimulation and for 30 second non-stimulation. PPG was measured on the earlobes of experimenters at 200Hz sampling frequency. PPG amplitude, PPI(Pulse to Pulse Interval), and PRV(Pulse Rate Variability) were analyzed according to arousal level. T-test was performed to compare between the PPG variables of rest and relaxation, rest and arousal, and relaxation and arousal. Relative to the rest state, PPG amplitude decreased in relaxed state and increased in aroused state. Relative to the rest state, PPI decreased in both emotional states. However, more significant decline was observed in aroused state. PRV's LF and HF were used in the form of LF/HF to compare between the relaxed and the aroused state. Therefore, PPG signal showed significant differences between relaxed and aroused state. In conclusion, evaluation of human arousal level used in the PPG analysis demonstrated that PPG has better usability and comforter measurement than ECG and is clearly an alternative method of measuring arousal level.

Discrimination of Three Emotions using Parameters of Autonomic Nervous System Response

  • Jang, Eun-Hye;Park, Byoung-Jun;Eum, Yeong-Ji;Kim, Sang-Hyeob;Sohn, Jin-Hun
    • Journal of the Ergonomics Society of Korea
    • /
    • v.30 no.6
    • /
    • pp.705-713
    • /
    • 2011
  • Objective: The aim of this study is to compare results of emotion recognition by several algorithms which classify three different emotional states(happiness, neutral, and surprise) using physiological features. Background: Recent emotion recognition studies have tried to detect human emotion by using physiological signals. It is important for emotion recognition to apply on human-computer interaction system for emotion detection. Method: 217 students participated in this experiment. While three kinds of emotional stimuli were presented to participants, ANS responses(EDA, SKT, ECG, RESP, and PPG) as physiological signals were measured in twice first one for 60 seconds as the baseline and 60 to 90 seconds during emotional states. The obtained signals from the session of the baseline and of the emotional states were equally analyzed for 30 seconds. Participants rated their own feelings to emotional stimuli on emotional assessment scale after presentation of emotional stimuli. The emotion classification was analyzed by Linear Discriminant Analysis(LDA, SPSS 15.0), Support Vector Machine (SVM), and Multilayer perceptron(MLP) using difference value which subtracts baseline from emotional state. Results: The emotional stimuli had 96% validity and 5.8 point efficiency on average. There were significant differences of ANS responses among three emotions by statistical analysis. The result of LDA showed that an accuracy of classification in three different emotions was 83.4%. And an accuracy of three emotions classification by SVM was 75.5% and 55.6% by MLP. Conclusion: This study confirmed that the three emotions can be better classified by LDA using various physiological features than SVM and MLP. Further study may need to get this result to get more stability and reliability, as comparing with the accuracy of emotions classification by using other algorithms. Application: This could help get better chances to recognize various human emotions by using physiological signals as well as be applied on human-computer interaction system for recognizing human emotions.