• Title/Summary/Keyword: Automotive plant

Search Result 156, Processing Time 0.024 seconds

Gain Scheduled Discrete Time Control for Disturbance Attenuation of Systems with Bounded Control Input (제어입력 크기제한을 갖는 시스템에서 외란 응답 감소를 위한 이산시간 이득 스케줄 제어)

  • Kang, Min-Sig;Yoon, Woo-Hyun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.3
    • /
    • pp.32-39
    • /
    • 2009
  • A new discrete time gain-scheduled control design is proposed to improve disturbance attenuation for systems with bounded control input under known disturbance maximum norm. The state feedback gains are scheduled according to the proximity of the state of the plant to the origin. The controllers are derived in the framework of linear matrix inequality(LMI) optimization. This procedure yields a linear time varying control structure that allows higher gain and hence higher performance controllers as the state moves closer to the origin. The main results give sufficient conditions for the satisfaction of a parameter-dependent performance measure, without violating the bounded control input condition under the given disturbance maximum norm.

Analysis of the Heating and Cooling Energy Load for Facade Variation in Plant Factory (식물공장의 건물 형태에 따른 냉난방부하 분석)

  • Lee, Chan-Kyu;Kim, Woo-Tae
    • Proceedings of the KAIS Fall Conference
    • /
    • 2012.05b
    • /
    • pp.569-572
    • /
    • 2012
  • 식물공장의 다양한 건물형태에 따른 냉난방부하의 차이를 DesignBuilder를 이용하여 해석하였다. 엽채류 중 상추의 생육 적정온도인 $20^{\circ}C$를 실내온도로 설정하고 식물공장 외벽에 단일창호를 적용하여 온실형태에 따른 냉난방부하 변화를 계산하였다. 보광이 없는 건물자체의 냉난방부하를 계산한 결과 KNU 식물공장 단위유닛과 반원 온실형 식물공장이 냉방부하가 가장 적었다. 보광 적용 후에는 전반적으로 KNU 식물공장 단위유닛과 직사각형 식물공장이 양호한 냉난방 성능을 보여주었다. KNU 식물공장 창호의 면적이 와이드 스팬형보다 크기 때문에 건설비용의 증가가 예상되지만 회전형 스마트 조명 제어시스템을 적용하게 되면 재배면적을 넓히고 공간활용에 유리하다. 또한 LED 사용량을 줄일 수 있어 냉방부하와 보광에 드는 비용을 절감할 수 있다.

  • PDF

Analysis of the Heating and Cooling Energy Load of the KNU Plant Factory with Single Skin Windows (단일창호를 적용한 KNU 식물공장의 냉난방 에너지 부하 해석)

  • Lee, Chan-Kyu;Kim, Woo-Tae
    • Proceedings of the KAIS Fall Conference
    • /
    • 2012.05b
    • /
    • pp.575-578
    • /
    • 2012
  • 단일창호를 적용한 KNU 식물공장 모델의 냉난방 에너지 부하를 DesignBuilder를 이용하여 해석하였다. 상추의 적정생육온도인 $20^{\circ}C$를 기준으로 이중창호를 적용한 경우와 에너지 소모량을 비교 분석하였다. 단일창호가 이중창호에 비해 연간 냉방부하는 약 128 MWh 감소하고 난방부하는 약 26 MWh 증가하여 단일창호가 냉방부하저감에 유리하다고 판단된다. KNU 식물공장의 중앙에 위치한 공간의 상부를 지붕구조물로 닫거나 계절별로 개폐하면서 냉난방부하에 미치는 영향을 계산하였다. 지붕구조물을 설치하게 되면 단위유닛이 취득하는 태양열이 감소하여 냉방부하가 감소하게 된다. 또한 지붕구조물을 상시 닫아두는 것이 계절별로 여닫는 것보다 냉방부하 저감에 유리하다. 식물공장 측면벽에 overhang과 sidefin을 설치하면 차양효과로 냉방부하가 감소하지만 감소비율은 크지 않았다. 에너지 부하의 대부분을 차지하는 냉방부하를 낮추기 위해 구조물이나 차양을 설치할 수 있으나 절감효과에 비해 설치비가 증가할 수 있기 때문에 추가 경제성 연구가 필요하다.

  • PDF

A Study on the Reduction of Cooling Load of the Multiple Skin Windows for Plant Factory using Cool Tube (쿨튜브를 적용한 식물공장 다중창호의 냉방부하 저감에 관한 연구)

  • So, Jae-Hyun;Kim, Woo-Tae
    • Proceedings of the KAIS Fall Conference
    • /
    • 2012.05b
    • /
    • pp.579-582
    • /
    • 2012
  • 본 논문에서는 쿨튜브를 적용한 식물공장 이중창호와 삼중창호의 열전달 차단성능을 3차원 수치해석을 통해 비교분석하였다. 이중창호 설계변수인 유입구의 개수와 중공층 두께조건에 따라 창호를 통해 식물공장 외부에서 내부로 유입되는 열전달량을 분석하였다. 쿨튜브를 통해 중공층으로 유입되는 공기속도가 이중창호에서는 0.95 m/s, 삼중창호의 경우는 0.50 m/s 이상일 때 창호를 관통하여 외부에서 내부로 유입되는 열에너지가 차단되는 결과를 얻었다. 삼중창호의 경우에 중공층 유입 공기속도를 0.50 m/s 이상으로 증가시킬 경우 오히려 식물공장 내부의 열에너지가 중공층으로 빠져나가 실내온도를 낮추는 효과가 나타났다. 본 연구의 결과를 바탕으로 국내 지역별 기후데이터의 온도조건을 고려한 분석을 추가적으로 진행할 계획이다.

  • PDF

Development of the Smart Lighting Control System for Plant Factory (식물공장용 스마트 조명제어 시스템 개발)

  • Lee, Won-Sub;Kim, Sung-Gaun
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.12b
    • /
    • pp.425-428
    • /
    • 2011
  • 회전식 스마트 조명 시스템은 기존 식물공장에 무수히 많이 설치되는 LED와 형광등을 대신하여 비교적 적은 양으로 설치된 LED와 형광등을 회전시키는 시스템으로써 작물 재식판의 작물들에게 필요한 광을 회전하며 공급하는 방법이다. 이로 인하여 식물공장에 조명 시스템을 설치할 때 방생되는 고가의 초기 설치비용을 해결하고자 하는 시스템이다. 본 논문에서는 식물이 생장하는데 필요한 광량과 광속, 광양자속 밀도를 계산하고 블레이드에 설치되는 LED의 개수를 설정하였으며, 조명 시뮬레이션 프로그램 Relux를 이용하여 조명 장치가 회전함에 따라 조명장치의 중심과 바깥쪽에 생기는 광량의 차이를 확인 하였다.

  • PDF

Resonance and Instability of Blade-Shaft Coupled Bending Vibrations with In-plane Blade Vibration

  • Anegawa, Norihisa;Fujiwara, Hiroyuki;Okabe, Akira;Matsushita, Osami
    • International Journal of Fluid Machinery and Systems
    • /
    • v.1 no.1
    • /
    • pp.169-180
    • /
    • 2008
  • As a major component of a power plant, a turbine generator must have sufficient reliability. Longer blades have lower natural frequency, thereby requiring that the design of the shaft and blade takes into account the coupling of the blade vibration mode, nodal diameter k=0 and k=1 with vibration of the shaft. The present work analyzes the coupling of the translation motion of the shaft with in-plane vibration of the blades with k=1 modes. At a rotational speed ${\Omega}_1=|{\omega}_s-{\omega}_b|$, the resonance of the blades has a relatively large amplitude. A violent coupled resonance was observed at a rotational speed ${\Omega}_2=|{\omega}_s+{\omega}_b|$. Resonance in blade vibration at ${\Omega}_1=|{\omega}_s-{\omega}_b|$ was experimentally confirmed.

Study on Robust Control for Proportional Pressure Control Valve with MRC (MRC를 이용한 비례압력제어밸브의 강인한 제어에 관한 연구)

  • Yun, So-Nam;Jeong, Hwang-Hun;Lee, Ill-Young
    • Journal of Power System Engineering
    • /
    • v.17 no.1
    • /
    • pp.77-84
    • /
    • 2013
  • The proportional pressure control valve that was used to relief valve has different dynamic characteristics on each case. Because this valve has different assembling or processing error and environmental condition. However, a customer who used the relief valve wants to have a steadily performance even if the dynamic characteristics of valve was changed. For this reason, the manufacturer try to make the robust controller that has simple structure. This paper concerns about the design of robust controller that didn't affected by plant parameter's changing. The control strategy is a model reference control that conducted by on line identification problem, gradient method and Lyapunov equation. This adaptvie control law's validity that this paper deal with was confirmed by an results of step response test or hysteresis test.

An Investigation into the PID Control for the Electro- Hydraulic Servo System of Skin Pass Mill

  • Lee, Jae-Cheon;Kim, Seong-Jin
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.2 no.4
    • /
    • pp.47-53
    • /
    • 2001
  • This study is to investigate the problem of the SPM(Skin Pass Mil7) system which is a finishing treatment of steel sheet. and to develop a PID control scheme to minimize process instability. An electrohydraulic servo system with conventional proportional controller used to regulate the force on the strip works inadequately to yield very undesirable transient responses at the moments welding parts of the strip conte into and pass through the rolls. Both linearized and nonlinear models of a typical SPM system ware simulated first by using Simulink. Then Ziegler-Nichols ultimate cycling method was used for an initial reference guide to tune PID gains, and further fine tuning was performed to get desirable response. The test result in the plant show that proposed PID control scheme successfully improves the process instability in a SPM system.

  • PDF

The Simulation of PEMFC System Performance for Automotive Application (1) (작동조건을 고려한 자동차용 PEM 연료전지 시스템 성능 시뮬레이션 (1))

  • Bang, Jung-Hwan;Kim, Han-Sang;Lee, Dong-Hun;Min, Kyoung-Doug;Kim, Min-Soo;Cho, Young-Man
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.460-465
    • /
    • 2003
  • The modeling of PEM (Proton Exchange Membrane) fuel cell system consisting of fuel cell stack and BOP (Balance of Plant) is presented in this paper. The effects of temperature, pressure (air, hydrogen), and humidity on the fuel cell system performance were mainly investigated using thermo-dynamical and electro-chemical equations. To understand the power distribution characteristics of fuel cell system, the effects of operating temperature and air pressure on maximum power and system power were also demonstrated. Through this study, we can get the basic insight into the fuel cell stack and BOP component sizing and it can be used effectively for the optimization of the practical fuel cell systems in purpose.

  • PDF

Simulation and Analysis of an Automative Assembly Operation at Mercedes-Benz

  • 박영홍
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 1999.10a
    • /
    • pp.217-217
    • /
    • 1999
  • The main objective of this study is to simulate the design and operational policies of the assembly shop of an automotive plant for planning purposes and to find possible improvements. The simulation study was used to answer the following questions: How does the sequence affect the daily throughput\ulcorner What are the bottlenecks to the assembly lines in a given scenario\ulcorner A Simulation model was developed in accordance with the objective of this study. The model incorporates detailed workstation logic to accurately model downtime results through the use of a pull cord system. It is written with SIMAN. The discrete event feature of SIMAN does not adequately model the conveyor systems of the asembly shop. As a result, a few subroutines were added to the SIMAN modeling structures to mimic the operations of the assembly shop. Use of the model uncovered attractive improvement opportunities, such as a tremendous gain in annual volume if four additional spaces were added to a between-line buffer.

  • PDF