• Title/Summary/Keyword: Automatic water control system

Search Result 195, Processing Time 0.028 seconds

A Fundamental Study for the Automatic Control System in Greenhouse Using Microcomputer(I) (마이크로컴퓨터에 의한 시설재배의 자동화에 관한 기초연구(I))

  • Kim, C.S.;Kim, J.H.
    • Journal of Biosystems Engineering
    • /
    • v.19 no.2
    • /
    • pp.99-111
    • /
    • 1994
  • Automatic control system using microcomputer that have been studied in greenhouse, however, it was very difficult operation with success due to handicap for a various conditions and cultivated plants. This study was performed in order to develop of the basic program and hardware system for automatic control in greenhouse, such as automatic supplying of water, liquefied fertilizer solution and chemical solution. The results were summarized as follows. 1. The program for soil moisture control used by the switch type tensiometer was well operated. 2. The proximity switch was applied as well to water level control but it was very expensive, so low-priced sensor has to be developed. 3. The water meter was not excellent for mixing control of liquefied fertilizer, chemical and water, so water meter for only agricalture has to be developed. 4. Interface system for this study was suited to the developed controller. 5. Automatic control system to supply for water, liquefied fertilizer and chemical solution that was well operated as a fundamental study for product of controller.

  • PDF

Development of an Automatic Irrigation Control System in Protected Horticulture (시설원예에 있어서 물관리 지동화 시스템 개발)

  • 김경수;이기명;장익주
    • Journal of Bio-Environment Control
    • /
    • v.1 no.1
    • /
    • pp.61-71
    • /
    • 1992
  • This study is performed to develop an automatic irrigation control of system for effective water management in greenhouse. The automatic irrigation control system is composed of an IR-RED optical sensor in tensiometer and an One-chip micro controller. The following results are obtained : 1. A practical IR-RED optical sensor in tensiometer, which shows the starting point of irrigation, was developed. 2. The automatic irrigation system with the optical sensor and One-chip micro controller was developed and also designed to be able to combine with the control system for temperature, curtain opening, etc. 3. A multiple irrigation control system for several greenhouses were suggested. 4. The results of the system test with the driving program for automatic water management were excellent.

  • PDF

Development of an Automatic Water Control System for Greenhouse Soil Water Content Management (시설재배 토양의 수분 조절을 위한 자동 수분제어시스템 개발)

  • Lee, D.H.;Lee, K.S.;Chang, Y.C.
    • Journal of Biosystems Engineering
    • /
    • v.33 no.2
    • /
    • pp.115-123
    • /
    • 2008
  • This study was conducted to develop an automatic soil water content control system for greenhouse, which consisted of drip irrigation nozzles, soil water content sensors, an on/off valve, a servo-motor assembly and a control program. The control logic adopted in the system was Ziegler-Nichols algorithm and rising time, time constant and over/undershoot ratio as control variables in the system was selected and determined by various control experiments to maintain small delay time and low overshoot. Based on the experimental results, it was concluded that the control system developed in the study could replace the unreliable conventional greenhouse soil water management.

Fundamental Studies for the Automatic Control System in the Greenhouse Using Microcomputer(II) -A Development of a Controller for an Automatic Control System- (마이크로컴퓨터에 의한 시설재배의 자동화에 관한 기초연구(II) -자동화 시스템의 종합제어기 개발-)

  • 김진현;김철수
    • Journal of Biosystems Engineering
    • /
    • v.20 no.1
    • /
    • pp.73-86
    • /
    • 1995
  • The automatic control system in the greenhouse have to be developed to the direction of considering various factors the variables such as condition of the cultivation and greenhouse, the properties and types of products. Therefore, it is more important to set up variables appropriately than the problems of automatic control system itself, and the automatic control system which satisfy these problems should be simplified in the aspect of operation. In addition, even the individual automations are not perfect yet, so more studies are required for the development of comprehensive automatic system in korea. This study was carried out to automatize environment control systems for greenhouse, especially from most intensive labor requiring parts such as watering, irrigating liquefied fertilizer, spraying chemicals, mixing and ventilation system, etc. The results are summarized as follows. 1. Control type tensiometer was expected to be desirable in the automation of watering system, therefore, a new tensiometer was designed and developed through this study. 2. The chemical spraying system developed through this study was found to be excellent in the aspect of operation. 3. When pulse type water discharge meter was used in the mixing of liquefied fertilizer and chemical solution, the error of mixing were range $\pm$0.1~0.15%. 4. The water level switch of electrod type used for controlling water level was found to be affective in both control performance and operation cost. 5. The water and level control system can be omitted if each tank size are standardized in accordance with greenhouse size, therefore, the installation cost might be significantly reduced. 6. The developed general controller was excellent in hardware parts, but still remained to be improved in software parts.

  • PDF

Development of the Automatic Control System for the Advanced Phosphorus Treatment in Sewage Treatment Plant (하수처리시설에서 인 고도처리를 위한 자동제어시스템 개발에 관한 연구)

  • Kim, Seon-Gok;Lee, Ho-Sik;Jun, Tae-Sung
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.2
    • /
    • pp.300-304
    • /
    • 2012
  • It has a limitation to satisfy the phosphorus effluent criteria of 0.2 mg/L which will be reinforced from 2012 with the Biological Nutrient Removal (BNR) process. The chemical coagulation process has been operated in parallel with the biological treatment process for advanced treatment of phosphorous in the developed countries including Europe. However, the coagulation process has some disadvantages such as the desired goal may not be achieved without injecting the optimum dosage of the coagulant. This study developed the automatic control system to inject the optimum dosage of phosphorous coagulant into the coagulation process. The adopted coagulant was 10% Poly Aluminum Chloride (PAC) in this study. The automatic control system developed in this study was adopted for the treatment of the phosphorus from the effluent in SBR process. The automatic control system was composed of the data receiving part, the optimum coagulant dosage control part and the data transmit part. The result of the phosphorous advanced treatment of the SBR effluent using the automatic control system showed the removing efficiency over 95% consistently with the phosphorous concentration under 0.02 ~ 0.15 mg/L. The reproducibility analysis for checking the safety of automatic control system showed more than 95% correlation.

DEVELOPMENT OF A CONTROL SYSTEM FOR AN AUTOMATIC ROAD SIGN REMOVING EQUIPMENT USING HIGH PRESSURE WATER-JET (초고압수를 이용한 노면표시 자동제거 장비개발을 위한 제어시스템 및 노면최적조건에 대한 연구)

  • Kwon Soon-Wook;Kim Kyoon-Tai;Han Jae-Goo
    • Korean Journal of Construction Engineering and Management
    • /
    • v.5 no.4 s.20
    • /
    • pp.139-146
    • /
    • 2004
  • Resent removal work for road signs has been labor intensive and required times since it has been done manually using shaving type equipment. While traditional process is conducting, there are traffic jams caused by the passing control, and happened unexpected accidents to workers working at dangerous road circumstance. Besides, in current shaving method, there are high potentialities on the air pollution as well as the explosive accident occurred by using a propane gas. So, as an alternative, we have studied to develop the automatic erasing equipment made up with a high pressure water-jet system and automatic control system, mobile system; Wate-rjet system consists of an intensifier and nozzles to give a high pressure and spray on the sign, and automatic control system is composed of one axis robot using a hydraulic servo actuator controlled by a lever, And as a mobile system, a truck plays an important role for the transport of equipment and the forward movement in a removal process. In this paper, we have analyzed the characteristics of road signs and have investigated current erasing methods in the field. And we have organized and designed automatic erasing equipment, and we have made a basic experiment to find out the optimal spray condition as like the spray distance, spray angle and injection pressure.

Development of Automatic Decision System for Cholrination Demand in Water treatment Plant (정수장내 염소요구량 자동결정시스템 개발)

  • Oh, Sueg-Young;Lee, Sung-Ryong
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.807-812
    • /
    • 2000
  • Chlorination dosage in water treatment plant of field is determined by chlorination demand experiment through two or three hours after raw water was sampled in inflow. It is impossible to continuously control fer real time because sampled water is adapted chlorination dosage after water treatment process had been proceeded. Therefore in this study, we will design informal chlorination demand system this designed system will be experimented as to water quality and accuracy of control in various conditions. Throughout these. experimental results, we will revise the system and revised system is enable to optimal control of chlorination dosage. Finally, We have developed chlorination demand system, which can automatically determination of chlorination dosage to be determined according to variety of raw water quality inflow in water treatment plant.

  • PDF

Development of Automatic Decision System for Chlorination Demand in Water Treatment Plant (정수장내 염소요구량 자동결정시스템 개발)

  • Oh, Sueg-Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.6
    • /
    • pp.757-764
    • /
    • 2002
  • Chlorination dosage in water treatment plant of field is determined by chlorination demand experiment through two or three hours after raw water was sampled in inflow. It is impossible to continuously control for real time because the sampled water is adapted chlorination dosage after water treatment process had been proceeded. Therefore in this study, we will design informal chlorination demand system, this designed system will be experimented as to water quality and accuracy of control in various conditions. Throughout these experimental results, we will revise the system and the revised system is enable to optimal control of chlorination dosage. Finally, we have developed chlorination demand system, which can automatically determination of chlorination dosage to be determined according to variety of raw water quality inflow in water treatment plant.

The AQR Control in the SCADA System of Manless Power Plant (무인발전소 SCADA SYSTEM 에서의 AQR 제어 운영)

  • Ok, Yeon-Ho;Lee, Eun-Woong;Byun, Ill-Hwan;Kim, Ki-Won;O, Seok-Yeong;Choi, Hyeong-Cheol;Lee, Nam-Hyung
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.58_59
    • /
    • 2009
  • Generator excitation system, supplying the voltage to power system, is controlled by various manners as aspects of power system. Previously excitation systems mainly used AVR(Automatic Voltage Regulator) and FCR(Field Current Regulator) to control voltage, but nowadays the excitation systems have the tendency to adopt AQR(Automatic Reactive power Regulator) and APFR(Automatic Power Factor Regulator) to do it so as to get into step with diverse requirements of power system and high digital technology. This paper presents which operation methods is effective for the equipment, according to increase the unmanned power station thanks to automation technic.

  • PDF

The Technology of Peak Demand Reduction using Automatic Water Tank Pumping System on the Apartment And Analysis of Effect of Energy Cost (아파트 고가수조 자동급수장치를 이용한 전력피크 감소 및 전력시장에서의 효과 분석)

  • Lee, Jae-Gul;Lee, Yun-Kyoung;Cho, Won-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.161-163
    • /
    • 2006
  • This paper introduce the technology of peak demand reduction using automatic water tank pumping system on the apartment. That systems on the apartments installed water tank can control pumping(electricity) demand. Generally, system peak demand is occurred at the same time on workday and many water pumps consume electric power randomly. At this point, shift of operating time of water pump can reduce peak demand using automatic water tank pumping system. We were operating this system on some apartments for test of effect of peak demand reduction. and we represent result of demand shift. This result suggests that spread of the automatic water pumping system can contribute to reduce system peak demand and reduce system operation cost.

  • PDF