• Title/Summary/Keyword: Automatic measurement

Search Result 1,013, Processing Time 0.029 seconds

Establishment of Information Interface Technology between Hull and Outfitting Designs (선체설계와 의장설계간의 정보인터페이스 기법 연구)

  • Choi, Yeong-Tae;Suh, Heung-Won;Lee, Soon-Sup
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.50 no.6
    • /
    • pp.458-465
    • /
    • 2013
  • Ship design engineering refers to the development and design of shipbuilding architectures in a drawing which reflects all relevant manufacturing processes. This paper provides analysis methods for model-information interfaces between hull structure design and outfitting design, and a technical application for manufacturing phases reflecting the pipe support pad and angle item automatically. The existing information procedure of pipe support pad and angle system processes information using drawing without model specification. Outfitting design team directly distributes drawings to the shop floor then manual-based marking and installation work are conducted refer to the distributed drawings. As a result, this process has become time consuming and causes problems in the productivity and quality improvement due to the rework caused by omitted or incorrect marking. The pipe support pad and angle marking is a method that automatically updates model information to hull structure design using sets of data that analyse the generated model in outfitting design processes. Therefore, this approach provides an efficient solution through design references without manual activities such as a reflection of hull structure design, cutting process, numerical control work, and dimension measurement and marking. The conversion of a method from the existing procedure based on manual marking to the reflective and automatic approach would have enabled to proceed installation work without manual activities for the measurement. Therefore, this research study proposes an efficient approach using pre-data analysis of model information interfaces between design and manufacturing phases to improve productivity during construction for shipbuilding.

Three-dimensional shape measurement using grating patterns form an optical spatial modulator

  • Tsujioka, Katsumi;Ito, Hiroshi;Furuhashi, Hideo;Higa, Shuntaro;Hayashi, Niichi;Yamada, Jun;Hatano, Kazuo;Uchida, Yoshiyuki
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1994.10a
    • /
    • pp.561-565
    • /
    • 1994
  • An automatic measuring system of three dimensional shape by a projection method with grating pattern from in optical spatial modulator has been developed. The characteristics of the system were studied. This system is composed of a projector, an optical spatial modulator, a CCD camera, and computer. A liquid crystal is used as the optical spatial modulator. The grating patterns that ire projected on the surface of the object are controlled by the computer connected with the optical spatial modulator. The projector patterns are measured by the CCD camera. The data are transferred to the computer. After a transformation into line data, the data are analyzed to obtain the coordinate of the surface of the object. This system has advantages as follows. (1) It is possible to capture the surface topography without any contact. (2) The time required for the measurements is shorter than the light-section method. (3) An optical spatial modulator using a liquid crystal is possible to control the grating patterns accurately by a computer. Surfaces of a plate and a cylinder were measured. The threshold level had an influence on the measurement. It was shown that this system has adequae accuracy in the measurements.

  • PDF

Development of 3 Channel Biomedical Signal Measurement System for Mac-yule (맥율용 3채널 생체신호 계측시스템 개발)

  • Byeon, M.K.;Kim, H.J.;Jang, J.K.;Han, S.W.;Huh, W.
    • Journal of IKEEE
    • /
    • v.11 no.1 s.20
    • /
    • pp.24-29
    • /
    • 2007
  • In this paper, we developed a Mac-Yule measurement system which consider psychological stable state of patience. The developed system consist with a hardware device that can derive a EEG, respiration and pulse wave, and a software which acquire a biological signal and signal processing The EEGs are derived with bipolar method from frontal head. The respiration signals obtain from nasal front with a transducer which consist with thermistor bridge. The pulse waves are detected from earlobe with photoplethysmograph method. A power spectrum of EEG are used as the decision parameters of psychological stable state of patience. The decision of Mac-Yule are defined as origin text method that of numbers of pulse to 1 respiration period. As the results of experiment with developed system, we could have a spectrum band discretion of EEG signal, stable respiration signal detection and automatic gain controlled pulse signal with realtime. And then, we could detect Mac-Yules from processed signals.

  • PDF

Development of an Optical Range Finder for Surface Roughness Measurements (표면 요철 측정을 위한 광학적 거리 측정기 개발)

  • Eom, Jung-Hyun;Park, Hyun-Hee;Seo, Dong-Sun;Huh, Woong;Kim, Joon-Bum;Kim, Yon-Gon
    • Journal of IKEEE
    • /
    • v.2 no.1 s.2
    • /
    • pp.53-60
    • /
    • 1998
  • We develope a high repetition rate, short distance, optical range finder for surface roughness measurements of large structures, such as a highway road, etc. For range measurement based on a triangulation principle, we use a light emitting diode and an one dimensional Position sensitive photodetector for a light source and an angle detector of the reflected light at the object, respectively. The range finder has automatic power control and electrical background noise rejection capabilities which enable it to overcome variations of an object reflectance and to eliminate time-varying, as well as constant, background light noises. Our experimental results show less than ${\pm}1.5mm$ of measurement errors regardless of an object reflectance, for $22{\sim}38cm$ object ranges which are determined by considering the installation of the range finder and the depth of surface roughness.

  • PDF

Development of Automatic Measurement and Control Method based on Single Chip Microcomputer for Tackjoo Fermentation (Single Chip Microcomputer를 이용한 탁주발효(濁酒醱酵)의 자동계측(自動計測)과 제어방법(制御方法)의 개발(開發))

  • Kim, Kyung-Man;Chun, Jae-Kun
    • Korean Journal of Food Science and Technology
    • /
    • v.25 no.4
    • /
    • pp.391-394
    • /
    • 1993
  • For the automation of Tackjoo fermentation, a sensor measurable gas production during brewing and a controller were built. The performance tests were carried out at 10 litter Tackjoo fermentor, The sensor was consisted of a transparent acryl cell for bubble formation and photo-interrupter for the detection of bubbles of 0.018ml size. The fermentation controller was fabricated with a single chip microcomputer (MC68705R3) and provided with both the monitoring module of temperature measurement and the valve controling device for the cooling water circulation in coil type heat exchanger. The operation programs were developed and systemized in ROM. With this computer system, the gas production amount and rate were acquired during the Tackjoo fermentation. The fermentation curve based on the gas production rate showed a good agreement with that of alcohol concentration. The maximum rate of gas production was found after 24 hr at $30^{\circ}C$. The correlation equation between the gas production and alcohol concentration was established and used as the control algorithm of the fermentation.

  • PDF

Segmental Bioelectrical Impedance Analysis(SBIA) for Determining Body Composition (부위별 생체 전기 임피던스법을 이용한 체성분 분석에 관한 연구)

  • 차기철;손정민;김기진;최승훈
    • Korean Journal of Community Nutrition
    • /
    • v.2 no.2
    • /
    • pp.179-186
    • /
    • 1997
  • A new bioelectrical impedance method has been developed and evaluated. The electrodes; were made of stainless steel and electrical interfaces were created by an upright subject gripping hand electrodes and stepping onto foot electrodes. Eight tactile electrodes were in contact with surfaces of both hands and feet; thumb, palm and fingers, front sole, and rear sole. Automatic on-off switches were used to change current pathways and to measure voltage differences for target segments. Segmental body resistances and whole body resistance(RWHOLE)were measured in 60 healthy subjects. Segmental resistances of right arm(RRA), left arm(RLA), trunk(RT), right leg(RRL) and left leg(RLL)were310.0$\pm$61.6$\Omega$, 316.9$\pm$64.6$\Omega$, 25.1$\pm$3.4$\Omega$, 236.8$\pm$31.2$\Omega$ and 237.6$\pm$30.4$\Omega$, respectively. Individual segmental impedance indexes(Ht2/RRA, Ht2/RT, and Ht2 /RLA) were closely related to lean body mass(LBM)as measured by densitometry ranged from r=0.925 to 0.960. Ht2/(RRA+RT+RLA) predicted LBM slightly better(r=0.969) than the traditional index, Ht2/RWHOLE(r=0.964), supporting the accuracy of the segmental measurement. A multiple regression equation utilizing Ht2/RRA, Ht2/RT and Ht2/RRL predicted LBM with r=0.971. Ht2/RRA term of the regression contributed to more than 40$\%$ of the LBM prediction, indicating that lean mass of arm represented whole body LBM more closely than other body segments. The new bioimpedance method was characterized by upright posture, eight tactile electrodes, segmental measurements and utilization of electronic switches in comparison with the traditional method. The measurement with this new method was extremely reproducible, quick and easy to use.

  • PDF

Comparison of Test Standards for the Performance and Safety of Agricultural Tractors: A Review

  • Kabir, Md. Shaha Nur;Chung, Sun-Ok;Kim, Yong-Joo;Shin, Sung-Hyun
    • Journal of Biosystems Engineering
    • /
    • v.39 no.3
    • /
    • pp.158-165
    • /
    • 2014
  • Purpose: The objective of this paper was to compare test standards regarding the performance and safety of agricultural tractors to identify the differences in test conditions, measurement tolerances, and test procedures. Based on the comparison, some recommendations were proposed for possible revisions or improvements to current tractor test standards. Methods: The test standards and codes of major standards development organizations (SDOs), such as the Organization for Economic Cooperation and Development (OECD), the International Organization for Standardization (ISO), the American Society of Agricultural and Biological Engineers (ASABE), EC type approval, and the board of actions of the Nebraska Tractor Test Laboratories (NTTL), were selected and analyzed. Comparison of the test standards: The ISO provides references for fuel and lubricants for tractor tests, and the OECD provides additional measurements for calculating fuel consumption characteristics during the power take-off (PTO) tests. The ISO, EC type approval, and the ASABE provide PTO protective device and the safety requirements. During drawbar power tests, seven transmission ratios are selected for fully automatic transmissions, according to the OECD. In case of hydraulic lift tests, ISO 789-2 and OECD Code 2 advise the use of a static lift force, while SAE J283 advises the use of additional dynamic lift capacity tests for a better representation of in-field operations. The OECD, the ISO, and EC type approval determine the seat index point (SIP), whereas the ASABE determines the seat reference point (SRP) for roll-over protective structure (ROPS) tests. Diversified measurement tolerances were among the braking performance test standards. The European Union (EU) has developed daily limits for vibration exposures with adaptations from ISO 2631-1. Electromagnetic compatibility evaluations are emerging of high-efficiency tractors due to the long-term conformance to electromagnetic emissions and interferences. Comparisons of tractor test standards discussed in this paper are expected to provide useful information for tractor manufacturers and standards development personnel to improve the performance and safety test standards of tractors.

A Study for measurement method of P-wave duration in Paroxysmal Atrial Fibrillation(PAF) subjects (발작성 심방세동 환자의 P파 간격 측정 방법에 관한 연구)

  • Lee, J.Y.;Yeo, H.S.;Han, W.T.;Kim, I.Y.;Lee, B.C.;Kim, J.S.;Mi, J.S.;Seo, J.D.;Lee, W.R.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.181-182
    • /
    • 1998
  • In previous study for correlation between P-wave Signal Averaged Electrocardiography (SAECG) and Paroxysmal Atrial Fibrillation (PAF) subjects, we showed that the duration of P-wave in subjects is longer than in controls. In this respect, the P-wave SAECG is a new method proving to be an accurate and independent noninvasive marker for the risk of PAF. To prove this suggestion, accurate detection and alignment of P-wave are indispensible. In previous study, we measured P-wave duration by manual. So it was not accurate and consistent. To measure the P-wave duration accurately and automatically, we have developed an automatic algorithm for P-wave duration measurement. We showed that the duration of P- wave in the subjects is longer than in controls with this algorithm.

  • PDF

A Study on the Relationship with Acupuncture Stimulation and Stress Using Heart Rate Variability (심박변이도를 통한 침자극과 스트레스의 상관관계 연구)

  • Lee, Seung-Gi;Park, Kyung-Mo;Choi, Woo-Jin
    • Journal of Oriental Neuropsychiatry
    • /
    • v.15 no.1
    • /
    • pp.197-209
    • /
    • 2004
  • Objectives : The purpose of this case-control research was to investigate the effects of acupuncture stimulation on autonomic nervous system for patients with HRV and to find out relationship with anti-stress effects. Methods : The study group consists of 24 patients with self-recognition of stress as the case group, and 20 normal person as the control group by similar age. We measured HRV of case and control groups before acupuncture stimulation, prick acupuncture in Hegu(LI4), Taichong(Liv3), Shenme(H7), Neiguan(P6), Zusanli(S36). After treating for 20 minutes, measurement values of HRV and PSV were compared for pre-acupuncture and post-acupuncture. Results : 1. LF norm, HF norm, LF/HF between the case and control groups were significant different in HRV before acupuncture stimulation in the 1st experiment. 2. HRT, SDNN, SDSD, LF norm, HF norm, and LF/HF of the case group were significant different in HRV after acupuncture stimulation in the 1st experiment. HRT of the case group was significantly different in HRV after acupuncture stimulation in the 1st experiment. 3. LF norm, HF norm, LF/HF of the case group were significant different between the 1st and 2nd experiment in HRV before acupuncture stimulation. 4. LF norm, HF norm, and LF/HF were significant different between the 1st and 2nd experiment in HRV of patients whose symptoms improved. But HRV of patients whose symptoms unimproved didn't show significant difference. Conclusion : The results suggest that acupuncture stimulation is associated with changed activity in the sympathetic and parasympathetic nervous system. Measurement values of HRV is suitable to estimate the activity of automatic nervous system.

  • PDF

The Effects of Acupuncture Stimulation and Progressive Relaxation Therapy on Examination Stress of Students -Using Heart Rate Variability and Pupil Size Variability - (침자극과 이완요법이 시험 스트레스에 미치는 영향 - 심박변이도와 동공크기변이도를 사용하여 -)

  • Kwak, Sun;Lee, Seung-Gi;Park, Kyung-Mo;Choi, Woo-Jin
    • Korean Journal of Acupuncture
    • /
    • v.21 no.2
    • /
    • pp.161-176
    • /
    • 2004
  • Objectives : The purpose of this study was to investigate the effects of acupuncture stimulation and relaxation therapy on autonomic nervous system for students with examination stress by HRV, PSV and to find out relationship with anti-stress effect. Methods : The study group consists of 42 students were classified into three groups randomly : acupuncture stimulation group(male n=8, female n=6), relaxation therapy group(male n=8, female n=6) and rest group(male n=8, female n=6). Using heart rate variability and pupil size variability, we measured the value of HRT, SDNN, SDSD, LF norm, HF norm, LF/HF ratio, Pupil area, and compared the changes the sympathetic- parasympathetic activity. Measurement value were compared before and after, during midterm examination and normal times. Results : 1. HRT, LF/HF ratio, LF norm of acupuncture group was significantly decreased and HF norm were significantly increased in HRV after acupuncture stimulation at a term of examination. While variables of the other group were no significantly different. 2. SDNN of acupuncture group were significantly increased in HRV after acupuncture stimulation at normal times. 3. Pupil area, LF norm, HF norm of three group were no significantly different in PSV at a term of examination. 4. Pupil area of relaxation group were significantly decreased in PSV at normal times. While variables of the other group were no significantly different. 5. HRT of rest group were significantly decreased in HRV between three groups at a term of examination and normal times. 6. Pupil area of relaxation group were significantly decreased in PSV between three groups at a term of examination and normal times. Conclusion : The results suggest that acupuncture stimulation is associated with changed activity in the sympathetic and parasympathetic nervous system. Measurement values of HRV and PSV are suitable to estimate the activity of automatic nervous system.

  • PDF