• Title/Summary/Keyword: Automatic level measurement

Search Result 98, Processing Time 0.023 seconds

A Segmentation Method for Counting Ammonia-oxidizing Bacteria (암모니아산화세균의 계수를 위한 영상분리기법)

  • 김학경;이선희;이명숙;김상봉
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.287-287
    • /
    • 2000
  • As a method to control the bacteria number in adequate level, a real time control system based on microscope image processing measurement for the bacteria is adopted. For the experiment, Ammonia-oxidizing bacteria such as Acinetobacter sp. are used. This paper proposed hybrid method combined watershed algorithm with adaptive automatic thresholding method to enhance segmentation efficiency of overlapped image. Experiments was done to show the effectiveness of the proposed method compared to traditional Otsu's method, Otsu's method with adaptive automatic thresholding method and human visual method.

  • PDF

Automatic Recognition in the Level of Arousal using SOM (SOM 이용한 각성수준의 자동인식)

  • Jeong, Chan-Soon;Ham, Jun-Seok;Ko, Il-Ju
    • Science of Emotion and Sensibility
    • /
    • v.14 no.2
    • /
    • pp.197-206
    • /
    • 2011
  • The purpose of the study was to suggest automatic recognition of the subject's level of arousal into high arousal and low arousal with neural network SOM learning. The automatic recognition in the level of arousal is composed of three stages. First, it is a stage of ECG measurement and analysis. It measures the subject playing a shooting game with ECG and extracts characteristics for SOM learning. Second, it is a stage of SOM learning. It learns input vectors extracting characteristics. Finally, it is a stage of arousal recognition which recognize the subject's level of arousal when new vectors are input after SOM learning is completed. The study expresses recognition results in the level of arousal and the level of arousal in numerical value and graph when SOM learning results in the level of arousal and new vectors are input. Finally, SOM evaluation was analyzed average 86% by comparing emotion evaluation results of the existing research with automatic recognition results of SOM in order. The study could experience automatic recognition with other levels of arousal by each subject with SOM.

  • PDF

Radiation level distribution monitoring system (방사선 분포 모니터링 시스템)

  • 최영수;박순용;이종민
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.828-831
    • /
    • 1996
  • Radiation monitoring system is needed at nuclear power plant and nuclear facility. Manual survey techniques are commonly used, but they are time consuming and somewhat inaccurate. Automatic radiation surveys are very important because it provides significant savings in men-rem and wages. Unmanned, remote automatic radiation measurement system should be small and light-weighted in order to mount on robotic system. The system we have developed consists of detection parts, signal processing part, interface, and software part. Position information is provided by using of a collimator. The measurement process is achieved by the scanning of detector and image processing techniques are used to display radiation levels. We designed collimators, detectors, signal processing circuit, and constructed prototype system. The goal of this system is the mapping of camera image and radiation level distribution.

  • PDF

Development of Rain Gauge and Observation Error (우량계 개발과 측정 오차)

  • 김대원;이부용
    • Journal of Environmental Science International
    • /
    • v.11 no.10
    • /
    • pp.1055-1060
    • /
    • 2002
  • A new method of automatic recording raingauge is developed to measure rainfall 1200mm full scale with high accuracy and resolution. The principle of new instrument is to detect a weight change of a buoyant weight according to a change in water level of raingauge measured by the use of a strain gauge load cell. This method has the advantage of increasing measurement accuracy, since no moving equipment is used. Laboratory test of the instrument was recorded 0.4% error of 190mm rainfall amount. The validity of new instrument was examined by comparing its measured values with values recorded by automatic weather station on June 24 to 25 2001 at Daegu Meteorological Station, when there is 148.3mm rainfall amount. In spite of much rainfall there is only 0.77mm difference of total rainfall amount. This instrument was accomplished high accuracy and resolution at field test in much rainy day.

A Measurement Algorithm using Gray-level Thresholding in Automatic Refracto-Keratometer (그레이-레벨 한계 기법을 이용한 자동 시각 굴절력 곡률계의 측정 알고리즘)

  • Sung, Won;Park, Jong-Won
    • The KIPS Transactions:PartB
    • /
    • v.9B no.6
    • /
    • pp.727-734
    • /
    • 2002
  • Currently. people become interested in the development of measuring instrument related to eyesight. In this study, we developed software of electronic part in automatic refracto-keratometer. If an automatic system, which uses images from an optical instrument, can inform the in-spector of an accurate eyesight measured value after the internal process, the frequency of mistakenly observed value will be reduced considerably. This software is using morphological filtering and gray-level signal enhancing techniques. The morphological filtering is the first process, from images of the optical instrument, to transform an original image which is hard to process into manageable one. The second process is a signal enhancing technique to the first processed image using gray -level thresholding technique and is used to reduce an error caused by the variety in distribution of the gray value of image. Therefore, this software system in electronic part will make more effective eyesight measurement by reducing the error effectively when applied to the optical image which is difficult to get accurate measurement value.

Automatic RF Input Power Level Control Methodology for SAR Measurement Validation

  • Kim, Ki-Hwea;Choi, Dong-Geun;Gimm, Yoon-Myoung
    • Journal of electromagnetic engineering and science
    • /
    • v.15 no.3
    • /
    • pp.181-184
    • /
    • 2015
  • Evaluation of radiating radiofrequency fields from hand-held and body-mounted wireless communication devices to human bodies are conducted by measuring the specific absorption rate (SAR). The uncertainty of system validation and probe calibration in SAR measurement depend on the variation of RF power used for the validation and calibration. RF input power for system validation or probe calibration is controlled manually during the test process of the existing systems in the laboratories. Consequently, a long time is required to reach the stable power needed for testing that will cause less uncertainty. The standard uncertainty due to this power drift is typically 2.89%, which can be obtained by applying IEC 62209 in a normal operating condition. The principle of the Automatic Input Power Level Control System (AIPLC), which controls the equipment by a program that maintains a stable input power level, is suggested in this paper. The power drift is reduced to less than ${\pm}1.16dB$ by AIPLC, which reduces the standard uncertainty of power drift to 0.67%.

Automatic measurement of gage block using digital image processing (디지탈 화상처리를 이용한 게이지 블록의 측정 자동화)

  • Ko, Y.U.;Suh, H.S.;Eom, T.B.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.11 no.5
    • /
    • pp.56-65
    • /
    • 1994
  • We have carried out a research on automatic measurement of gage blocks below 250mm and then improved the accuracy of the system, and reduced the measurement time using image processing technique and computer interface. The accuracy of the system is (230+10330 $L^{2}$)$^{2}$ nm (L:m) with confidence level of 95%. We participated APMP gage block intercomparision-1993/1994. The 1st round intercomparision showed that the measured values of all 5 gage blocks were within 21 nm from average.

  • PDF

Development for Automatic Thickness Measurment System by Digital Image Processing (디지탈 이미지 프로세싱을 이용한 자동두께 측정장치 개발)

  • 김영일;이상길
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1993.10a
    • /
    • pp.395-401
    • /
    • 1993
  • The purpose of this paper is to develop an automatic measuring system based on the digital image processing which can be applied to the in-process measurement of the characteristics of the thin thickness. The derivative operators is used for edge detection in gray level image. This concept can be easiliy illustrated with the aid of object shows an image of a simple light object on a dark background, the gray level profile along a horizontal scan line of the image, and the first and second derivatives of the profile. The first derivative of an edge modeled in this manner is () in all regions of constant gray level, and assumes a constant value during a gray level transition. The experimental results indicate that the developed qutomatic inspection system can be applied in real situation.

  • PDF

An Evaluation of the Reliability and Validity of the Automatic Pennation Angle Measuring Program (깃각 자동측정 프로그램의 신뢰도와 타당도 평가)

  • Kim, Jong-Soon
    • PNF and Movement
    • /
    • v.17 no.2
    • /
    • pp.329-337
    • /
    • 2019
  • Purpose: Ultrasound imaging is commonly used to measure the pennation angle of human skeletal muscles in vivo. However, manual assessment of the pennation angle using ultrasound images is subjective and time-consuming and requires a high level of examiner skill. The architectural analysis of human skeletal muscles is thus challenging. Automated approaches using image processing techniques are therefore required to estimate the pennation angle in ultrasound images. The purpose of this study was thus to assess the intra-tester and inter-tester reliability and validity of the pennation angle using an automatic measurement program. Methods: Twenty-two healthy young adults (mean age = 22.55 years) with no medical history of neurological or musculoskeletal disorders voluntarily participated in this study. Ultrasound imaging was used to measure the pennation angle of the gastrocnemius muscle at rest. One examiner acquired images from all the participants. The intra-tester and inter-tester reliability were evaluated using the intraclass correlation coefficient (ICC) to estimate reliability. Validity was measured using Pearson's correlation coefficient. Results: The intra-rater reliability was excellent for the automatic pennation angle measuring program and the manual pennation angle assessment method (ICC>0.95). The inter-rater reliability was also excellent for both methods (ICC>0.93). All the correlation coefficients for the automatic pennation angle measuring program and the manual pennation angle assessment method were 0.79, which indicated a significantly positive correlation (p<0.05). Conclusion: Pennation angle measurement using the automatic pennation angle measuring program showed acceptable reliability and validity. This study therefore demonstrated that the automatic measuring program was able to automatically measure the pennation angle of skeletal muscles using ultrasound images, and thus made it easy to investigate skeletal muscle architecture.

Analysis of Peak Flow Changes Using the Measured Data (실측자료를 이용한 하천의 수위변화 분석 - 강원도를 사례로 -)

  • Bae, Sun-Hak
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.14 no.2
    • /
    • pp.1-13
    • /
    • 2011
  • This study is to analyze the relationship between rainfall and water level using the measured data. During the rainfall event from September 9 to September 12, 2010, the rainfall and water level data were measured from automatic weather systems and automatic water level measurement systems which have been installed throughout Gangwon province. The result showed that the relationship between rainfall and peak flow change was different by basin and tributary. It is expected that this study will help to build a plan for preventing disasters and rainfall-runoff models for the river basins in Gangwon province.