• Title/Summary/Keyword: Automatic irrigation

Search Result 57, Processing Time 0.024 seconds

Growth and Development of Platycodon grandiflorus under Sensor-based Soil Moisture Control on Open Farmland and Pot Conditions

  • Lee, Ye-Jin;Kim, Kyeong-Soo;Lim, So-Hee;Yu, Young-Beob;Bae, Chang-Hyu
    • Korean Journal of Plant Resources
    • /
    • v.34 no.6
    • /
    • pp.608-615
    • /
    • 2021
  • Soil moisture control system including soil sensing and automatic water supply chain was constructed on open farmland and pot conditions. Soil moisture was controlled by the system showing over the soil moisture contents except 40% treatment. EC was gradually decreased by increasing cultivation days. On applying this system to control soil moisture, the growth and development characters of the bellflower were improved compared with control, cultivation without the automatic irrigation. Of the growth and development characters, plant height with water treatments was higher than that of control in 1st-year plants. Moreover, numbers of branch were increased by the increased soil moisture on farmland and pot condition. Capsule numbers for seed were best at 20%, 30% soil moisture treatment in 1st-year plants, and 20% to 50% treatment in 2nd-year plants. The construction of automatic soil moisture control system provide fundamental data for plant growth and development on open farmland soil condition.

Effect of Irrigation Automation Using Stem Diameter Variation as an Indicator of Irrigation Timing in Greenhouse Tomato (온실재배 토마토에서 관개시기 진단지표로 경직경 변화를 이용한 관개 자동화 효과)

  • 이변우;신재훈
    • Journal of Bio-Environment Control
    • /
    • v.8 no.4
    • /
    • pp.232-241
    • /
    • 1999
  • The automatic irrigation system using the stem diameter monitoring and the transpiration model for the determination, respectively, of irrigation timing and amount was designed and evaluated for its applicability in pot and field culture of greenhouse tomato. In the pot culture condition, the yield and quality of greenhouse tomato were improved when irrigation was practiced based on the stem diameter monitoring and the transpiration model as compared to the irrigation practice based on soil moisture monitoring. However, the effects were not significant in the field culture condition.

  • PDF

Development of the Automatic Inlet (자동물꼬의 개발)

  • 정하우;이남호;김성준;최진용;한형근;김대식
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.37 no.1
    • /
    • pp.49-54
    • /
    • 1995
  • Three types of floating-type automatic inlet were developed for the purpose of reduc- ing farmer's working hours required for water management and saving irrigation water. The point of automation is to use a float within the inlet which is floated and sinked by the ponding depth of paddy field, Thus opens and closes the control gate of irrigation. Suitability of each inlet may depend on production cost, applicability to paddy field condi- tions, and feasibility to farmers, etc. The first model was composed of three parts : chamber for irrigation control gate, chamber for float controlled by ponding depth, and connection bar between the two parts. It was designed to open and close the control gate gradually as the ponding depth drops and rises to a certain level. The second model was designed to improve the weak point of the first model which is the imperfect-closing of gate when it approaches to the end of ir- rigation. A switch-spring was equipped above the connection bar for perfect opening and closing of gate when the ponding depth reaches to a certain level. The third model was designed by combining the two chambers, that is, cut in halves the inlet volume of the above two models. Magnets were equipped above the float for perfect opening and closing gate. The functional experiment for three developed inlets was successfully carried out and the rating curves were derived.

  • PDF

Estimation of the Optimum Installation Depth of Soil Moisture Sensor in an Automatic Subsurface Drip Irrigation System for Greenhouse Cucumber (시설오이 지중관비시 자동관수센서의 적정 매설깊이)

  • Lim, Tae-Jun;Kim, Ki-In;Park, Jin-Myeon;Noh, Jae-Seung
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.46 no.2
    • /
    • pp.99-104
    • /
    • 2013
  • Vegetables production in greenhouse are typically intensely managed with high inputs of fertilizers and irrigation water, which increases the risk of ground-water nitrate contamination. In 2010 and 2011, a study was conducted to determine the appropriate depth of soil moisture sensor for automatic irrigation control to use water and nitrogen efficiently under subsurface drip irrigation (SDI) systems. The irrigation line for SDI placed 30 cm below soil surface and tensiometer was used as soil moisture sensor. Three tensiometer treatments placed at 10 (SDI-T10), 20 (SDI-T20) and 30 cm (SDI-T30) depths below soil surface under SDI. These are also compared to SUR-T20 treatment where tensiometer placed at 20 cm below soil surface under surface drip irrigation (SUR) systems. The growth of cucumber was not statistically different between SUR and SDI without SDI-T30 treatment. Fruit yields (Mg/ha) were 57.0 and 56.9 (SDI-T10), 56.0 and 60.5 (SDI-T20), 40.9 and 41.2 (SDI-T30) and 56.6 and 54.3 (SUR-T20) for 2010 and 2011, respectively. Slightly higher total yield was observed in tensiometer placed 20 cm below the soil surface, although no significant differences were found between SDI-T10 and SDI-T20 under SDI treatments. In addition, nitrogen application rates and daily irrigation rates were lowest in SDI-T20 compared with other SDIs and SUR treatments. Nitrogen and daily irrigation application under SDI-T20 was lower than that under SUR-T20 by 6.0%. These findings suggested tensiometer 20 cm depth under SDI systems was best for cucumber production in greenhouse.

Development of Operation Rules in Agricultural Reservoirs using Real-Time Water Level and Irrigation Vulnerability Index (실시간 저수위 및 용수공급 취약성 지표를 활용한 농업용 저수지 운영 기준 개발)

  • Nam, Won Ho;Choi, Jin Yong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.55 no.6
    • /
    • pp.77-85
    • /
    • 2013
  • The efficient operation and management strategies of reservoirs in irrigation periods of drought events are an essential element for drought planning and countermeasure. Korea Rural Community Corporation has developed the real-time water level observation system of agricultural reservoirs to efficiently operate reservoirs, however, it is not possible to predict drought conditions, and only provides information of current situation. Hence, it is necessary to evaluate accurate irrigation vulnerability and efficiently reservoir operation rules using current water level. In this paper, the improvement methods of reservoir operation planning were developed with water supply vulnerability characteristic curves comparing to automatic water gauge at agricultural reservoirs. The 11 reservoirs were simulated applying the reservoir operation rules which was determined by irrigation vulnerability characteristic curves criteria and real time water level, and evaluated water supply situation in 2012 year. The analysis of results can be identified probabilistic possibility of water supply failures compared with the existing reservoir operation criteria. These results of efficient reservoir operation rules can be achieved enable irrigation planners to optimally manage available water resources for decision making, and contributed to maintain the water supply according to demand strategy for agricultural reservoirs management.

Water Saving Irrigation Point in Cucumber Cultivation under Greenhouse (시설재배 오이의 물 절약 관개시점 구명)

  • Jeon, Sang-Ho;Hur, Seung-Oh;Ha, Sang-Keun;Jun, Hyun-Jung;Han, Kyung-Hwa;Cho, Hee-Rae;Hong, Soon-Dal
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.43 no.5
    • /
    • pp.540-545
    • /
    • 2010
  • This study was conducted to investigate effects of irrigation points on cucumber growth and water saving under greenhouse. Automatic irrigation system and tensiometers were installed at four plots to measure soil water tension and properties of irrigated water. Each plot was irrigated at different irrigation points; soil water tension of 15, 20, 30, and 40 kPa, respectively. Conventional irrigation plot without tensiometer was also investigated. The total yield and sugar contents of cucumber had no significant differences between plots. However, irrigated water volumes were saved most when irrigation points were 30, and 40 kPa. The two plots of 30, and 40 kPa treatments used about 60% less of irrigated water than the plot of conventional practice did. In conclusion, this research suggested that the optimum irrigation point for cucumber cultivation in greenhouse can be soil water tension of 30 kPa based on the results of overall cucumber quality, and Greenhouse water usage.

Effects of Subsurface Drip Irrigation and Aeration in Green Pepper Cultivation (시설풋고추 재배에서의 지중관수 및 공기주입 효과)

  • Kwon, Joon-Kook;Kang, Nam-Jun;Cho, Myeomg-Whan;Kang, Yun-Im;Park, Kyoung-Sub;Lee, Jae-Han
    • Journal of Bio-Environment Control
    • /
    • v.18 no.3
    • /
    • pp.225-231
    • /
    • 2009
  • 'Nokkwang' green pepper plants were grown in soil system (silty loam with pH 6.5) under the greenhouse, to determine the effects of subsurface drip irrigation (SDI) and subsurface drip irrigation plus aeration (SDIA) into root zone comparing with conventional surface drip irrigation (DI) in terms of water use efficiency, soil properties, and growth and fruit yield. Two drip lines per crop row were layed on the soil surface in DI system, buried at a depth of 20cm below the soil surface in SDI system, and also buried at a depth of20cm below the soil surface and aerated for 3minutes a hour during the daytime ($08:00{\sim}19:00$) by a air compressor in SDIA system. A automatic irrigation with starting point of -20kPa and ending point of -10kPa based on soil moisture contents was applied by controllers and electronic vacum soil moisture sensors. Reduction in soil moisture contents was delayed in SDI and SDIA, compared to DI. Irrigation amount applied in pepper cultivation was around 30% less in SDI than in DI. Electric conductivity and nitrate nitrogen content in the surface soil grown green pepper were significantly lowered in SSDI and SDIA, compared to DI. Better development of root system was observed in SDIA and SDI than in DI. Results showed that pepper fruit yield increased by 30% in SDIA and 22% in SDI in comparision with DI.

Water Requirement and Water Quality in the Paddy Plot Irrigated by Pipelines With an Automatic Hydrant (관수로 자동급수전 논에서의 용수량과 수질 -충북 보은군 학림 관수로 지구를 대상으로-(지역환경 \circled3))

  • 오광영;김진수;김선종;김영화
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.629-636
    • /
    • 2000
  • In this study, we investigated the characteristics of labor of water management and maintenance, water requirement, water quality(T-N, T-P, COD) in the paddy plot irrigated by pipeline with two types of hydrants: automatic and manual. The automatic hydrant have been introduced to the paddy field to save water and reduce the labor for water management. The automatic hydrant is automatically opened and closed according to the water depth of a paddy plot. The automatic hydrant generally developed more troubles than the manual hydrant. The water requirements are 2.7mm/d for the automatic hydrant plot and 17.6mm/d for the manual hydrant plot. The concentrations of pollutants in the two plots are higher in the ponded water than in the irrigation water and are highest after fertilizer application.

  • PDF