• Title/Summary/Keyword: Automatic fire protection system

Search Result 24, Processing Time 0.019 seconds

Automatic Fire Detector Spacing Calculation for Performance Based Design (성능위주설계를 위한 화재감지기배치의 공학적연구)

  • Park, Dong-Ha
    • Fire Science and Engineering
    • /
    • v.24 no.1
    • /
    • pp.15-23
    • /
    • 2010
  • Placement method for fire detectors prescribed in current fire safety regulation is just about placing a prescribed number of detectors according to the areas. However, this regulation has no scientific basis and standards from foreign countries are just introduced and fire detectors are installed complying with them. There are two standards in designing fire protection systems; Prescriptive-Based Design that follows stipulated regulations like fire safety standards and Performance-Based Design based on engineering knowledge such as fire dynamics, structural dynamics, mechanics of materials, fluid mechanics, and thermo dynamics. Recently, Fire Protection System Construction Business Act was revised so that fire protection systems can be designed using Performance-Based Design method ('05. 8. 4), though the method has not activated until now. In addition, the enforcement decree defines the range for specific objects of fire protection to which Performance-Based Design is applied ('07, 1. 24). At the moment, by manufacturing simulator so that formulas can be introduced and calculated with software in order to install fire detector of automatic fire detection systems keeping optimized distance, comparing the results with the state of fire detector placed according to Performance-Based Design and analyzing them, this study was intended to settle Performance-Based Design method in the future.

NEW TREND OF FIRE SCIENCE AND EIRE PROTECTION TECHNOLOGY

  • Sugahara, Shinichi
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.19-26
    • /
    • 1997
  • Firesafety design engineerings have been mainly derived from complicated rearrangement of descriptive specifications in codes or regulations through a great number of lessons from fire disasters. In this paper, the author refers to some recent developments in the field of building fire protection. At first, the author expresses his viewpoints concerning performance-based design codes, which have been popular throughout the world as a symbol of freedom from restricted usage of building materials and components prescrived in regulation or bylaws, in spite of some conflicts between objects-oriented design method and industrial mass production. Secondly, the author introduces several innovative fire protection methods adopted for large or void spaces in building complex. Finally, the author forcasts a next development of firesafety science and technology, aimed at securing personal safety in hyperscale urban areas.

  • PDF

A Study of Automatic Fire Detection Installation based CAN Comunnication (CAN 통신기반 자동화재탐지설비에 관한 연구)

  • Kim, Young-Dong;Oh, Guem-Kon;Kang, Won-Chan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.2
    • /
    • pp.50-59
    • /
    • 2006
  • In this paper, We are going to propose the fire protection system using CAN(Controller Area Network). The larger, higher and deeper buildings an, the more dangerous people are when fire happens. We should be aware of the problems of prior fire protection system. Therefore, we construct the embedded system based on CAN communication that is capable of N to N communication, and build independent fire protection system. If the fire is occurred on the building, the problem is that how fast we can detect the fire and put it on by using available system, this is major factor that reduces damage of our wealth. Therefore in this studies, We would like to design more stable system than current system. This system is based on CAN communication which is available N to N communication constructs and designed to compensate for each fault, so that our aim is to reduce the wires of system, cost of installation and to suppose future type fire protection system.

Improvement to the Applicable Scope of Automatic Fire Extinguisher to Reduce Fire Damage (화재피해 감소 위한 자동소화장치 적용범위 개선)

  • Baek, Chang Sun;Park, In Seon
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.1
    • /
    • pp.62-65
    • /
    • 2018
  • The rapid progress toward the 4th industrial society has led to possibilities of fire increase. It is pointed out that, though initial fire suppression is emphasized, the current legal systems do not sufficiently recognize the importance of initial fire suppression. In order to resolve this, problems of the current legal systems and regulations, as well as fire-fighting facilities to be equipped according to the size of specific fire-fighting objects, were diagnosed. Also, suggestions for improvement were provided through comparative analysis with relevant laws and technical regulations of Korea and other countries. According to fire safety standards such as NFPA, IMO, ISO, and Russian standards, automatic fire extinguishers are to be installed as per the adaptability criteria of fire extinguishers and automatic fire extinguishers. In Korea, the "Act on Fire Prevention and Installation, Maintenance, and Safety Control of Fire-fighting Systems" cover the types and scope of fire fighting facilities that include specific fire protection objects, such as electric room, power room, and substation room. This study has identified that, in case of a place with a floor area of less than $300m^2$, the installation requirement is not clearly specified. Therefore, in this study, fire extinguishing equipment and automatic fire extinguishing equipment to be added for each sub-use application are proved to have fire extinguishing performance of Class A, Class B, and Class C, respectively. In view of the fact that, in overseas standards, all space except containing such materials as Deep fire, metal fire and peroxide, can be installed with fire fighting equipment, a legal system for specifying the capacity units of fire fighting apparatus by application is, in this study, proposed.

A Study of Comparative Evaluation for High-rise Building Fire Risk by the Use of FREM (FREM을 적용한 고층건물의 화재위험도 비교평가연구)

  • 김동일;손기상;이수경
    • Fire Science and Engineering
    • /
    • v.16 no.1
    • /
    • pp.45-50
    • /
    • 2002
  • This study set its bases needed for building fire risk analysis by examining general concept and definitions of fire risk analysis, and its access methods. Upon this basis, by using a computer program FREM, we brought the type of hazards out of the fire risk assessment applied to the typical 100 high-rise buildings in and out of this country. In this process, we also sorted out the programs arising from the application of a foreign born tool to domestic conditions. the credibility of fire separations and automatic fire protection system in a building would be the two most important things in an attempt to evaluate fire risk in high-rise buildings. In addition, it is vital for the purpose of securing fire safety in high-rise buildings that the systems should be properly installed and carefully maintained. When we try hard to study the evaluation standards to the above systems and, someday in the future, to employ them in evaluating fire risks in high-rise buildings, we can measure the risks much more precisely with less expenses than that we needed today.

An Improvement of Fire Safety Code for Rack-Type Warehouse in Korea (국내 랙크식 창고의 방화관련 규정 개선에 관한 연구)

  • Kim, Woon-Hyung;Lee, Young-Jae
    • Fire Science and Engineering
    • /
    • v.28 no.6
    • /
    • pp.69-75
    • /
    • 2014
  • Recently Amore pacific rack-type warehouse fire broke out and argue an urgent improvement of fire protection design code including automatic sprinkler and detection design. Various type of commodities have their unique fire characteristics from fire spread rate and heat lease rate and fire hazard depends on storage height, rack arrangement, aisle width, fire load etc. With increasing ceiling height for more storage space prevent effective water spray of sprinkler head, also delays detection time causes failure of early suppression. To achieve fire protection code performance of this occupancy, Major code articles relating to a classification of commodity, sprinkler system installation, detection and fire fighting are reviewed and suggested based on fire case analysis, code review between country and field survey.

Experiment study on the Responsiveness of Spot- Type Heat Detector (열 감지기의 응답특성에 관한 시험연구)

  • Lee, Bok-Yeong
    • Fire Protection Technology
    • /
    • s.19
    • /
    • pp.9-16
    • /
    • 1995
  • The spot-type heat detector is a main component of the automatic fire alarm system intended to signal when heat energy is produced in protected area. The most of protected area in our country is installed spot-type heat detector. On this study, the responsiveness to the change of environmental temp. of spot-type heat detec-tor were obtained and analyzed under specified temp., velocity in accordance with the KOFEIS stan-dard. The experiment was carried under the condition with the change of environmental temp. Concluion of this study is as follows : 1. It was confirmed that the responsiveness of rate-of rise heat detector is sensitive to temp. below 10 degrees above zero. The malfunction appeared at 40 degrees above zero and intended performance is disqualified at 50 degrees above zero. 2. The intended performance of fixed-temp. detector which is maintained for the change of envi-ronmental temp. But the responsiveneness is confirmed instability for the change of environmental temp.

  • PDF

A Study about Introductory Plan of Automatic Wet Pipe Sprinkler System to Hydraulically Designed System (습식 스프링클러설비의 수리계산방식 도입방안에 관한 연구)

  • Park, Bong-Rae;Kong, Ha-Sung
    • Fire Science and Engineering
    • /
    • v.21 no.3
    • /
    • pp.69-77
    • /
    • 2007
  • Our country automatic wet pipe sprinkler system of hydraulically designed system has not deviated from the pipe regulation process, therefore we face limitations when using an independent method to hydraulically designed system. Therefore. after reviewing a developed country's methods using the drainage-density concept, we found it necessary for our country to introduce the drainage-density concept. Currently, under the National Fire Safety Codes(NFSC), this does not solve the problem and the limitation of hydraulically designed system because different problems arise depending on where the head was installed. To make improvements, first, such as the developed country, overcome the difference by introducing the drainage-density concept to determine the amount of drainage. Second, by using diverse head caliber and decreasing the limits on the amounts of distribution, we can expect a leveling off of the drainage density. Third, using the increase of hydraulically designed system through the application of the rule to hydraulically designed system, finally, development to performance based fire protection design.

Basic Study for performance Improvement of Fire Detectors System at Domestic Apartment Buildings (국내 공동주택 화재감지시스템의 성능개선을 위한 기초연구)

  • Son, Bong-Sae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.1
    • /
    • pp.533-538
    • /
    • 2014
  • This study examines the performance of and searches for improvements to the existing automatic fire detection systems installed at domestic apartment buildings as a basic study for development of intelligent fire detection systems specifically for apartments. Thus, this study aims to find out the problems in performance and maintenance of the existing fire detectors installed at apartment buildings which is the prerequisite process for development of intelligent fire detection system for that specific application. It is also found impossible to check whether or not the detectors installed at each apartment are in an operational state at normal times. This study finds that it is desirable to replace the slow-sensing heat detectors by a smoke and single smoke detectors which can detect a fire at its early stage in an effort to improve the problems of fire detectors installed at apartment buildings presently. Because we need to the independence fire detection system of apartment building.

Experimental Study on the Characteristics of Thermal Sensitivity for Fusible Alloy Type Sprinkler Head (가용합금형 스프링클러 헤드의 열감도 특성에 관한 실험적 연구)

  • 권오승;이진호
    • Fire Science and Engineering
    • /
    • v.9 no.1
    • /
    • pp.20-29
    • /
    • 1995
  • The sprinkler head is a component of the sprinkler system intended to discharge water for automatic detection and extinguishment of fires. On this study, thermal characteristic values affecting the sensitivity of the fusible alloy type sprinkler head were obtained and analyzed under heated air stream condition which had constant temperature and velocity. The experiment was carried out under the forced convection condition with both the conductive heat loss considered and neglected. The thermal characteristic values of the sprinkler head were obtained in accordance with the material and shape of the heat responsive element and the conditions of the main body.

  • PDF