• 제목/요약/키워드: Automatic capture verification

검색결과 2건 처리시간 0.038초

ECG 형태에 의한 자동화된 pacing 문턱 전압 결정에 관한 연구 (Automatic Determination of Pacing Threshold by Surface ECG Morphology)

  • 김정국;허웅
    • 대한의용생체공학회:의공학회지
    • /
    • 제22권3호
    • /
    • pp.269-273
    • /
    • 2001
  • Proper determination of pacing threshold is important for patient safety and pacemaker longevity. In general, cardiac muscle contractions caused by pacing pulses are verified by observing the morphology of surface ECG displayed on a monitor. In this study, a method of automatic pacing threshold determination based on morphological difference between intrinsic and paced ECGs was developed. First, characteristics of intrinsic ECG and paced ECG were analyzed in time and frequency domain and a proper discrimination parameter was extracted. Then, the automatic capture verification method based on the parameter was developed and applied to 23 pacemaker patients. The selected parameter was the area of ventricular depolarization wave during 80ms after pacing stimulus. It was found that the method was reliable and effective in identifying paced ECG and, thereby, determing a proper pacing threshold.

  • PDF

이식용 심장박동기(Pacemaker) 및 심장 세동제거기 (AICD)를 위한 심장 탈분극파 검출지연 방지 알고리즘 (A Belay Prevention Algorithm of Cardiac Depolarization Wave Detection for Pacemakers or Automatic Implantable Cardioverter/Defibrillator (AICD))

  • 김정국;박충규;한상휘;조병서;허웅
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1999년도 하계종합학술대회 논문집
    • /
    • pp.1063-1066
    • /
    • 1999
  • The delay of cardiac depolarization wave detection in the conventional pacemakers or AICD (automatic implantable cardioverter/ defibrillator, or ICD) has been overlooked. However, it is known that the delay may cause hemodynamic problems and may prevent the proper operation of a new automatic feature, automatic capture verification, that is to be appeared in the near-future devices. In order to reduce the effects of the delay, a delay prevention algorithm was developed and tested by applying three human electrograms. The algorithm set the sensing threshold just above the measured noise level to reduce the detection delay. It is found that the low threshold was able to reduce the delay by 20msec(average) In most cases. The implementation results showed reliability and efficacy of the algorithm, and the algorithm could be applicable to the existing hardware and software of the conventional pacemakers and AICD without any significant modifications.

  • PDF