Study on Adequate Positioning of Environmental Noise Automatic Measuring System in Busan (부산시 환경소음 자동측정망 설치위치의 적정성에 관한 연구)

  • Kim, Hwa-Il;Han, Kyoung-Min
    • Journal of Environmental Policy
    • /
    • v.8 no.1
    • /
    • pp.31-48
    • /
    • 2009
  • To install and operate the Automatic Noise Monitoring Networks reasonably, which able to monitoring environmental noise continually, is an important issue for making decision to urban environment. Noise level is determined by regional environmental factors, that affected by complex urban environment. Therefore, accurate measurement of environmental noise level has top priority to establish and promote appropriate environmental policies. Currently, Automatic Noise Monitoring System is installed for grasping the environmental noise level and preparing basic data for constructing noise-reduction policies. However, this measurement data is recognized not to be able to reflect a sensory noise. The main reason is the lack of reliable measurement data and unreasonable installation site. The main point of this research ought to be the analysis of installed site of noise monitoring system in Busan.

  • PDF

A Study on the Evaluation Method of Aircraft Noise (국내 항공기 소음 평가방법에 관한 실험적 연구)

  • Lee, Tai-Kang;Song, Kook-Gon;Kim, Hang;Jang, Gil-Soo;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.421-424
    • /
    • 2007
  • Currently domestic criteria for the aircraft noise is being adapted WECPNL(weighted equivalent continuous perceived noise level), while internationally preferred method is $L_{dn}$ which is based on from $L_{eq}$ and can also evaluate environmental noise. WECPNL used in domestic as an evaluation metric is only for the aircraft noise. It is, therefore, not adequate for the evaluation of residents' injury, moreover, it is very difficult to measure the aircraft noise by WECPNL due to the complicated calculating procedures as long as automatic measuring system is not used. Accordingly, this study aims to propose alternative evaluation metric for the aircraft noise. To achieve this purpose, WECPNL, $L_{eq}$, $L_{dn}$, other metrics and criteria were compared and analyzed.

  • PDF

Development of Elimination Method of Measurement noise to Improve accuracy for White Light Interferometry (백색광 간섭계의 정밀도 향상을 위한 노이즈 제거 방법)

  • Ko, Kuk-Won;Cho, Soo-Yong;Kim, Min-Young
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.6
    • /
    • pp.519-522
    • /
    • 2008
  • As industry of a semiconductor and LCD industry have been rapidly growing, precision technologies of machining such as etching and 3D measurement are required. Stylus has been important measuring method in traditional manufacturing process. However, its disadvantages are low measuring speed and damage possibility at contacting point. To overcome mentioned disadvantage, non-contacting measurement method is needed such as PMP(Phase Measuring Profilometry), WSI(white scanning interferometer) and Confocal Profilometry. Among above 3 well-known methods, WSI started to be applied to FPD(flat panel display) manufacturing process. Even though it overcomes 21t ambiguity of PMP method and can measure objects which has specular surface, the measuring speed and vibration coming from manufacturing machine are one of main issue to apply full automatic total inspection. In this study, We develop high speed WSI system and algorithm to reduce unknown noise. The developing WSI and algorithm are implemented to measure 3D surface of wafer. Experimental results revealed that the proposed system and algorithm are able to measure 3D surface profile of wafer with a good precision and high speed.

A study on the Automatic Detection of the Welding Dimension Defect of Steel Construct using Digital Image Processing (디지털 화상처리에 의한 강.구조물의 용접부 치수 결함 검출의 자동화에 관한 연구)

  • Kim, Jae-Yeol;You, Sin;Park, Ki-Hyung
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.8 no.3
    • /
    • pp.92-99
    • /
    • 1999
  • The inspection unit which is developed and used in this study, is processed the shape data from the CCD camera to seek welding bite section shape, and then calculated as a real dimension from measuring the value of each inspection item. The reason of measuring with the real in this study is came out from the image method which used for a long time, which is extricated the characteristic as the dimension of pixel by recognize pixel. The measurement method of the section shape is that we decide the thresholding value after we drew the histogram to binarizate the object. After that, we make flat the object to get rid of the noise and measure the shape of welded part through the boundarization of the object. The shape measurement is that measure the value of the welding part to adapt the actual operation program from using the ratio between the actual dimension of the standard specimen and the dimension of image, to measure the ratio between the actual product and the camera image. The inspection algorithm which estimates the quality of welded product is developed and also, the software GUI(Graphic User Interface) which processes the automatic test function of the inspection system is developed. We make the foundation of the inspection automatic system and we will help to apply other welding machine.

  • PDF

Design of Data Processing System for the Automatic Measurement of the Reverberation Time (잔향시간의 자동측정을 위한 데이터 처리 시스템 설계)

  • 이근구
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1984.12a
    • /
    • pp.86-90
    • /
    • 1984
  • In this paper, a method measuring the reverberation time simultaneously on all of the audio frequency range was studied. The system developed in this study is composed of a pink noise generator, filter bank, and microcomputer with graphic display. In the experiment, reverbration time data measured by existing analog method and by the system were compared, and were almost same through the audio frequency. Based on the conclusion, the subject method has more convenience and accuracy with algorithm program development without existing problems and it was found out that this kind of method is widely available for many branches of room accoustics and architectual acoustics.

  • PDF

Noise Reduction Method for Particle Measurement System using Beta-ray Absorption Method (베타선 흡수법을 이용하는 미세먼지 측정시스템을 위한 잡음제거 방법)

  • Choi, Hun;Sohn, Sang-Wook;Bae, Hyeon-Deok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.11
    • /
    • pp.1706-1712
    • /
    • 2012
  • The Beta-ray absorption method (BAM) gives a good solution for measuring the mass concentration of atmospheric particles(PM10 and PM2.5). To determine particular matters (PM) concentration, a ratio of the number of detected beta-ray intensity passing through the clean filter and the dust-sampled filter is used. These intensity data measured in air pollution monitoring such as PM10 and PM2.5 usually contained the additive noise(thermal noise, power supply noise and etc.). Therefore, the estimation performance of mass concentration can be deteriorated by these noises. In this paper, we present a new noise reduction method that is essentially required to develope an automatic continuous PM monitoring system using beta-ray absorption method. By combining the block data averaging technique and curve fitting, in the proposed method, the additive noise can be reduced in the measured data. To evaluate the performance of the proposed method, computer simulations were performed with computer generated signals as the input.

Automation of Primary Vibration Calibration System Using Laser Interferometer (레이저 간섭계를 이용한 진동 가속도계 절대교정 시스템 자동화)

  • Cho, Seung-Il;Lee, Yong-Bong;Jeon, Byeong-Su;Lee, Jong-Kyu;Lee, Doo-Hee
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.11 s.104
    • /
    • pp.1241-1247
    • /
    • 2005
  • An automation of primary vibration calibration system was developed and tested. Using GPIB interface, the console PC make the control of equipments, signal collecting and save measuring results automatically by the instructions in the program by Visual Basic. Several trials of automatic calibration for the accelerometer(ENDEVCO 2270) using this developed system give the reliable results.

Study on the Characteristics of Noise/Vibration in the Upright Laying Hen House (직립식 산란계사 내의 소음 진동 발생 현황 조사연구)

  • Lee S.J.;Chang D.I.;Chang H.H.
    • Journal of Animal Environmental Science
    • /
    • v.12 no.1
    • /
    • pp.21-28
    • /
    • 2006
  • This study was carried out to measure and analyze the characteristics of noise and vibration, and to analyze their effects on the productivity of layers, mechanical troubles, and abnormal wear-out failure of facilities and equipment of the layer house. The measurements of noise and vibration were taken at 13 layer farms nationwide for the operations of feed supplier system, feed distribution system, automatic egg collection system, ventilation system, blot conveyer for layer feces, and fur the case of with and without their operation by a sound level meter and a vibration measuring system in the layer house equipped with upright multi-tier cages. Measurement results showed that normal times were noise(N) 82 dB and vibration(V) 0.2072 cm/s, feed supplier system were 90 dB(N) and 2.8560 cm/s(V), feed distribution system were 90 dB(N) and 2.0222 cm/s(V), automatic egg collection system were 87 dB(N) and 0.1865 cm/s(V), ventilation system 88 dB(N) and 2.5364 cm/s(V), belt conveyer fur layer feces were 88 dB(N) and 0.2387 cm/s(V), and then maximum values of noise and vibration were 90 dB and 2.8560 cm/s, respectively, when feeding systems(feed supplying system and feed distribution system) were operated. Based on these results, an experiment is being conducted to find out the effect of noise and vibration on the productivity of layers in the layer house equipped with upright multi-tier cages.

  • PDF

Measurements and Statistical Modeling of Electromagnetic Noise from Electric Train (도시전철에서 발생한 전자파잡음의 측정 및 통계적 모형)

  • 심환우;윤현보;백락준;우종우
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.6 no.7
    • /
    • pp.37-47
    • /
    • 1995
  • In this paper, we have measured eletromagnetic noises from eletcric trains and the measurment data are treated statisticlly for monig. In order to measure the noise of electric tran, we set up an automatic measuring system andd measured the magnetic field over 9 kHz ~ 30 MHz range and electric field over 30 MHz - 1, 000 MHz range. The computer controlled measurint system yields efficiently experimental APD (Amplitude Probability distribution) data each of national rail road and subway train. The measured APD curves are analysed in terms of sensitivity study of Middleton's model through 6-parameter variation. Optimal parameters are obtained from measured data using Composite Approximation Algorithm.

  • PDF

Analysis of EMI Between Overlapped Railway Signalling Systems and Its Countermeasure (철도신호시스템 중첩운영으로 인한 전자파장해현상 분석 및 대책)

  • Kho, Young-Hwan;Yoon, Sun-Ho;Choi, Kyu-Hyoung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.6
    • /
    • pp.1116-1122
    • /
    • 2009
  • ATS(Automatic Train Stop) system makes train stop when it runs over the speed limit and ensure the safe operation of train. Seoul Metro line 2 in Korea, which started its passenger service in 1982, has adopted ATS system for its signaling system. The ATS system has only a train stop function at the time of emergency, and Seoul Metro is planning to replaced them with ATC(Automatic Train Control)/ATO(Automatic Train Operation) system which can provide the dedicated speed control for headway reduction and automatic operation of train. Until all the ATS system is replaced with the new ATC system, both systems are to operate simultaneously at the same metro line. In this situation, ATS system sometimes reveals improper operation: train stops suddenly without any obstacles in front of it. These emergency stops cause interruption of passenger service, and abnormal abrasion of wheels and rail. This paper makes it clear that these interruptions are caused by EMI phenomena between ATS on-board device and ATC wayside device : Signal current flowing in AF track circuit of ATC is turn out to be a EMI source that prevent normal operation of the ATS on-board device. Although the two systems have different frequency-ranges (ATS system has frequency range between $78{\sim}130$[kHz] and ATC system has frequency range between $9.5{\sim}16.5$[kHz]), it turned out that EMI phenomena appears between the both systems. This is investigated by measuring the output signal from ATS on-board device passing over ATC wayside device. The FFT(Fast Fourier Transform) analysis of the signal reveals that AF track circuit signal is transmitted to the ATS on-board device and induce noise causing improper operation. The countermeasures to the EMI phenomena are examined in three ways; blocking EMI transmission, enforcement of EMS (Electromagnetic Susceptibility) of ATS on-board device, and blocking the EMI source. It is suggested that the practical solution be blocking EMI source temporarily, that is breaking AF track circuit signal when the trains with ATS on-board device pass over it. To this purpose, TODS(Train Occupation Detection System) is developed, and has made a success in preventing the EMI problem of Seoul Metro line 2.