• Title/Summary/Keyword: Automatic Meter Reading Systems

Search Result 17, Processing Time 0.028 seconds

Development of an Integrated Meter Reading Home Concentrate Device (통합 원격검침 지시장치 개발)

  • Park, Jae-Sam
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.20 no.1
    • /
    • pp.37-42
    • /
    • 2015
  • This paper highlights the home concentrate device(HCD) that integrates the data reading and display of the six types of meters (water, hot water, heating, cooling, gas and electricity) used in Korean residential areas. Unlike the conventional system which utilizes single MCU, the developed system uses two MCUs for one MCU to gather the meter readings and for the other MCU to communicate to the server computer. Hard ware design, communication protocols, LCD design and program structures are discussed and the test results are shown in this paper. With the implementation of integrated meter reading, the developed system can increase the popularity of automatic meter reading(AMR) with its better scalability, pricing, installation fee, maintenance and faster response.

A study on field trial system for automatic meter reading and load control system (수용가 자동원방검침 및 부하집중제어 시스템 현장 실증시험연구)

  • 이원빈;문홍석;김석구;양완식
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1988.10a
    • /
    • pp.663-668
    • /
    • 1988
  • A study on Automatic Meter Reading and Load Control System used to Distribution Line Carrer has started since 1986, and the field trial system for AMR and LCS was installed to KEPCO on June, 1988. Now this system will be operated for testing. This paper will describe project and planning for field trial of KEPCO.

  • PDF

Development of LoRaWAN IoT Automatic Meter Reading Systems (LoRaWAN IoT 원격검침장치 개발)

  • Park, Jae-Sam
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.5
    • /
    • pp.913-922
    • /
    • 2020
  • In this paper, we propose a LoRa communication module using the LoRa RF module of Murata Electronics is designed to configure the IoT digital meter remote meter reading and a method of configuring a remote meter reading network by collecting multiple meter data in a DCU (Data Concentrate Unit) to configure a network with LoRaWAN. The developed system can be installed more easily and economically in the network configuration than the existing system by allowing the meter to be directly connected to the network or matched with a DCU to connect to the network according to the configuration of the consumer. The developed system was constructed using a digital water meter as an example, but it can also be applied to remote meter reading of the metered values of other meters such as electricity, water, gas, hot water and calorie meters. The main development contents are the design, configuration, and construction of digital meters, LoRa modules and DCUs, and how to connect the LoRaWAN network and transmit meter data to the server. By networking these devices, the system is configured, and the actual LoRaWAN communication is tested and the result is shown.

Performance of Equalizer Schemes in Power Line Communication Systems for Automatic Metering Reading (자동 원격검침을 위한 전력선 통신 시스템에서의 등화 기법 연구)

  • Kim, Yo-cheol;Bae, Jung-Nam;Kim, Jin-Young
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.11 no.1
    • /
    • pp.29-34
    • /
    • 2011
  • In this paper, we propose and analyze the equalizer schemes, zero-forcing (ZF) and minimum mean square error (MMSE) in power line communication (PLC) system for automatic meter reading (AMR). For efficient implementation of AMR system with PLC, effects of impulsive noise and multipath channel should be mitigated. To overcome these effects, the above equalizer schemes are employed. System performance is evaluated in term of bit error rate. From simulation results, it is confirmed that the equalizer can significantly improve bit error rate (BER) performance in PLC system, and MMSE equalizer provides better performance than ZF scheme. The results of this paper can be applied to AMR system as well as various smart grid services using PLC.

A study about Embodying an AMR Based on Power Line Communication.

  • Yoon, Gun;Park, Hong-Seong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.119.2-119
    • /
    • 2001
  • The inspection of a meter is an action that measures the amount of electricity, water and gas used to impose user on a charge. In past days, a meter who visit consumer to look over meter and write data to the ledger and then go back his office to calculates the inspection of a meter. On the other hand, the AMR(Automatic Meter Reading) is remote control system to measure the amount of utility used and monitor a condition of the meter. A study about AMRS is started at 1960 all over the world and a successful application example is presented continuously in American, Europe and Japan etc. In this paper we use a check meter that is used in past days and we add an AMR to it. AMR receives data that is the amounts of electricity from the check meter and stores those ...

  • PDF

Implematation of AMR system using Power ine Communication

  • Park, Byoung-Seok;Hyun, Duck-Hwa;Jang, Mun-Jeong;Lim, Young-Hoon;Cho, Sung-U
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.119.4-119
    • /
    • 2001
  • It is the advantage of PLC that digitalization and networking of existing facility can be organized at low price because there is no need further construction of communication line considering that home appliance, information device and various kind of control devices are digitalized at low price. Moreover, AMR(Automatic Meter Reading) is very attractive to utility company because not only does it reduce the cost of reading meter, but also it can control and monitor the demand for energy. So, it can solve the consumers problem best and easily. It also can be easily realized that the utilities can expand there areas to values-added service through existing network. The performance of the PLC modem which is being developed now is not moven enough and much more test for outdoor modem is needed especially. Therefore, we, KEPRI, concentrate our efforts on configuring AMR system for test and investigation of the actual performance of various kinds ...

  • PDF

Fault-tolerant ZigBee-based Automatic Meter Reading Infrastructure

  • Hwang, Kwang-Il
    • Journal of Information Processing Systems
    • /
    • v.5 no.4
    • /
    • pp.221-228
    • /
    • 2009
  • Due to low cost, low-power, and scalability, ZigBee is considered an efficient wireless AMR infrastructure. However, these characteristics of ZigBee can make the devices more vulnerable to unexpected error environments. In this paper, a fault-tolerant wireless AMR network (FWAMR) is proposed, which is designed to improve the robustness of the conventional ZigBee-based AMR systems by coping well with dynamic error environments. The experimental results demonstrate that the FWAMR is considerably fault-tolerant compared with the conventional ZigBee-based AMR network.

Development of Representative Curves for Classified Demand Patterns of the Electricity Customer

  • Yu, In-Hyeob;Lee, Jin-Ki;Ko, Jong-Min;Kim, Sun-Ic
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1379-1383
    • /
    • 2005
  • Introducing the market into the electricity industry lets the multiple participants get into new competition. These multiple participants of the market need new business strategies for providing value added services to customer. Therefore they need the accurate customer information about the electricity demand. Demand characteristic is the most important one for analyzing customer information. In this study load profile data, which can be collected through the Automatic Meter Reading System, are analyzed for getting demand patterns of customer. The load profile data include electricity demand in 15 minutes interval. An algorithm for clustering similar demand patterns is developed using the load profile data. As results of classification, customers are separated into several groups. And the representative curves for the groups are generated. The number of groups is automatically generated. And it depends on the threshold value for distance to separate groups. The demand characteristics of the groups are discussed. Also, the compositions of demand contracts and standard industrial classification in each group are presented. It is expected that the classified curves will be used for tariff design, load forecasting, load management and so on. Also it will be a good infrastructure for making a value added service related to electricity.

  • PDF

Power Quality Monitoring with Electronic Watt-hour meter and Wireless communication module (전자식 전력량계와 무선모듈을 이용한 전력품질 표시 및 모니터링)

  • Jung, Deug-Il;Son, Young-Dae
    • Proceedings of the KIEE Conference
    • /
    • 2007.10c
    • /
    • pp.172-174
    • /
    • 2007
  • An electronic watt-hour meter with high-precision measurement technology can provide many valuable metering data of a real-time system measurements, such as per-phase voltage, ampere, active power, reactive power, apparent power, power factor, and system frequency. Also many of accumulated metering data such as active energy, reactive energy, apparent energy, and load profile can be gettable from an electronic watt-hour meter[1]. This paper presents an approach of the small-sized AMR (Automatic Meter Reading) that provides customers with a very valuable electrical service. This AMR service transmits lots of a valuable metering data by using ZigBee communication module, so that users resided in their premises can use the information to audit a power quality and improve their electrical conditions by using the PQ monitoring device equipped with ZigBee receiver. This PQ monitoring device shows metering data on LCD and transmits to the PC through an internal network. Also, the device can keep the valuable meter data into a built-in non-volatile memory. The final goal of this paper is to better understand the power quality of electrical systems and offer the power qualify information for the convenience of all power consumers.

  • PDF

A Study on the pattern of energy consumption of apartment in winter with Automatic Meter Reading Systems (원격검침시스템을 활용한 공동주택의 동절기 에너지 소비패턴 분석)

  • Shin, Juho;Kim, Hongseok;Lee, Donghwan;Park, Seunghee
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.3
    • /
    • pp.1225-1234
    • /
    • 2013
  • According to the importance of greenhouse gas emissions, it grows day by day, the goverment is promoting to prepare the specific policy implementation to enhance building energy-saving design standars as the development agenda. In this study, the statistical analysis was performed by Descriptive statistics, Regression analysis, and Hypothesis testing to collect to generate and storage energy usage data in real time to settle parameter setting to affect energy consumption under energy-guzzling apartment not single building. This study is expected to be utilized as the basis for the optimum energy-saving design of the future of the building or facility energy costs rise and the demand for energy-efficient and stable management.