• Title/Summary/Keyword: Automatic Exposure Control

Search Result 96, Processing Time 0.026 seconds

Analysis of Factors Related to Pain Relief on Modified Mammography (변형 유방촬영술시 통증완화에 따른 요인 분석)

  • Jang, Myung Mi;Kim, Hwa Sun
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.5
    • /
    • pp.413-421
    • /
    • 2017
  • Mammography, the basic test for finding and treating increased breast cancer, gives the anxiety of cancer and radiation exposure to most women. In addition, it gave very severe compression pain, so we studied the degree of pain and tried to reduce the pain. The purpose of this study is to compare and analyze the modified imaging technique and the basic imaging technique based on clinical experience, respectively. The subjects of this study were 160 women from 30 to 60 years old who visited to Seoul Boramae Hospital operated by Seoul National University Hospital from February to March 2017 for breast screening. Modified 80 persons and 80 persons were divided into two groups, and each group was asked to fill out questionnaires sequentially without knowing the subjects. The first method is a modified method in which an automatic pedal is divided into four or more presses, a manual pressure is used together, and an attitude is described in detail. Secondly, we used only the automatic pedal compression method and press it within 1-3 times. In the mean of the pain distribution, the experimental group (modified method) was 2.49 and the control group (basic method) had an average of 4.86, which showed 48.8% less pain. In this modified method, the pain scores of the experimental group were lower than those of the control group, and the degree of the pain was statistically significant.

The Relationship Between Airborne Trichloroetnylene Concentrations and Total Trichloro-compounds and Trichloroacetic Acid in Urine (근로자의 트리클로로에틸렌 폭로 농도와 요중 총삼염화물 및 삼염화초산 농도와의 관계)

  • Jeon, Hasub;KIm, Hyunwook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.4 no.1
    • /
    • pp.7-16
    • /
    • 1994
  • This study was designed to establish the relationship between airborne trichloroethylene concentrations and total trichloro-compounds and trichloroacetic acid in urine samples of the trichloroethylene exposed workers, to examine if the biological screening value for trichloroacetic acid in urine set by the Ministry of Labor is appropriate, and to suggest a suitable biological screening value for total trichloro-compounds in urine. Seventy male workers from the cleaning, the packing, and the inspcetion areas were selected as the study group and eighty male office workers were chosen as the control group. The results were as follows: 1. The mean values of total trichloro-compounds and trichloroacetic acid in the exposed group ($48.1{\pm}1.5mg/{\ell}$, $19.7{\pm}1.9mg/{\ell}$) were significantly higher than those in the control group($4.3{\pm}1.5mg/{\ell}$, $1.8{\pm}1.2mg/{\ell}$). 2. The airborne tichloroethylene concentrations were significantly related with the concentrations of total trichloro-compounds in urine(r=0.8212) and the concentrations of trichloroacetic acid in urine(r=0.7216). 3. The average trichloroethylene concentrations in the manual cleaning plants and that in the automatic cleaning plants were 40.1 ppm and 7.7 ppm, respectively. The difference between two groups was statistically significant. 4. The geometric mean of 49.6 ppm trichloroethylene concentration was resulted in the $185.4mg/{\ell}$ total trichloro-compounds in urine, and the 50 ppm trichloroethylene concentration was expected to produce $170.4{\pm}28.5mg/{\ell}$ total trichloro-compounds in urine. 5. With the geometric mean of 49.6 ppm trichloroethylene concentration, the corresponding geometric mean concentration of trichloroacetic acid in urine was $74.7mg/{\ell}$. In conclusion, the level of personal exposure to trichloroethylene concentration was significantly correlated with the concentrations of total trichloro-compounds and trichloroacetic acid in urine. Current biological screening value of $75mg/{\ell}$ for trichloroacetic acid in urine set by the Ministry of Labor was thought to be appropriate, and a biological screening value for total trichloro-compounds in urine should be set in the range of $170.4{\pm}28.5mg/{\ell}$ as a reference value for trichoroethylene exposure.

  • PDF

Clinical Evaluation for System Performance of Image Intensifiers (상강화기의 임상평가)

  • Kim, Chang-Seon;Charles R. Wilson
    • Progress in Medical Physics
    • /
    • v.9 no.3
    • /
    • pp.143-154
    • /
    • 1998
  • The image intensifier is the key component which determines the imaging characteristics in a fluoroscopic imaging system. A system performance program for clinical evaluation of two image intensifiers, that is simple, non-invasive and time effective, was described. Tests were grouped into three headings: x-ray generator, image quality, and collimation. For the x-ray generator, the kVp accuracy and the automatic exposure control operation were compared. Low- and high-contrast resolution measurements, and mesh pattern study belong to the image quality tests and those tests were performed for the video monitor and photospot images. For the collimation, usable field diameter and image distortion of image intensifiers were measured and quantified. The procedures and the results are hoped to be used for the clinical evaluation of system performance and/or acceptance tests for image intensifiers.

  • PDF

A Study on the Deduction of Internal Temperature of the Ground Magazine (지상형 탄약고의 내부온도 감소 방안 연구)

  • Park, Hyungju;Choi, Myoungjin;Yang, Jaekyung
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.36 no.3
    • /
    • pp.142-149
    • /
    • 2013
  • Among ammunitions which are stored in a war field, the lifespan of propelling gunpowder is affected by storage environment such as storage temperature, humidity, and exposure to sunlight. These are because Nitrocellulose (NC) which is the main component of propelling gunpowder can be naturally disassembled to unstable substances similar with other nitric acid ester. We can't prevent it fundamentally from being disassembled, but to restrain induction of automatic disassembly by decomposition product, a decomposition product ($NO_2$, $NO_3$, and $HNO_3$) and tranquillizer DPA (Diphenylamine), having high reactivity, are added into a propellant. For this, it will decrease the velocity of tranquillizer which can also affect the velocity of producing the decomposition product of NC, storage temperature or humidity of propelling gunpowder is higher, drop of tranquillizer content is much faster. Therefore, to extend storage lifespan of propelling gunpowder, it is really important to control storage temperature or humidity inside the magazine. Hereupon, according to the manufacture of small scale model magazine and the result of performing experiments and measuring variation of inside temperature (storage temperature), using roof types that have a steel slate structure of magazine among ground magazines, this research shows the differences in details.

Variation of Image Quality and Dose by Applying Multi-Leaf Collimator for Digital Mammography (디지털 유방촬영장치에서 다엽 조리개 적용으로 인한 화질과 선량의 변화)

  • Kwon, Soon Mu;Kim, Boo Soon;Park, Hyung Jun;Kang, Yeong Han
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.7
    • /
    • pp.535-540
    • /
    • 2015
  • Collimator has important functions with control primary X-ray that decrease radiation exposure dose for patients and reduce scatter ray and make better quality of image. But there are no regulations for X-ray mammography device of collimator, so widely used device adopt rectangularly controlled collimator. Though digital X-ray mammography device expand supply recently, rectangularly controlled collimator of film/screen mode still used. After searching for real condition of beam field with digital mammography, we made a multi-leaf collimator which is able to adjust the beam field in accordance with size and shape of breast, and we measuring up the transitions of image quality, average glandular dose(AGD) and, Dose area product(DAP). There are no significant differences between rectangularly controlled collimator and multi-leaf collimator, and DAP value decreased by 50.72%. As conclusion, there needs to expand the use of multi-leaf collimator for optimum adoption of beam field in digital mammography, and also need to develop an automatic regulation of beam field for reduce of exposure dose to patients.

A Study on Chest X-ray Using Ancillary Device for Child Radiography (방사선촬영 보조기구를 이용한 어린이 흉부 엑스선 검사에 관한 연구)

  • Rhee, Do-byung;Lee, Somi;Choi, Hyunwoo;Kim, Jong-ki;Lee, Jongmin
    • Journal of Biomedical Engineering Research
    • /
    • v.39 no.1
    • /
    • pp.48-54
    • /
    • 2018
  • In this study, We developed a Ancillary device for child radiography for X-ray of children under 5 years old and verified its effectiveness. Chest X-rays of children younger than 5 years of age were performed by Supine method at the position of Table detector, Short - Source to Image Receptor Distance(SID). Existing Supine and Short -SID imaging methods cause many problems, such as errors in image reading and excessive radiation exposure dose to patients, but the use of an Ancillary device for child radiography(ADCR) solves these problems. A total of 160 children were divided into the Upright group using ADCR and Supine group without ADCR. The chest X-ray image was visually evaluated by two radiologists with reference to the European Commission's List of Quality Criteria for Diagnostic Radiographic Images in Pediatrics. The total score of the qualitative evaluation was 5.15% higher in the chest upright method using ADCR than in the chest supine method without ADCR, and the chest upright method score was higher than that of the chest supine method in items 1 to 7. whether infants have deep inspiration or not, 4.87% higher for item 1, whether infants rotate or not and the degree of tilting, 0% higher for the item 2, the reproduction of image from just above apices of lungs to T12/L1, 0% for the item 3, reproduction of the vascular pattern in central 2/3 of the lungs, 6.92% higher for the item 4, reproduction of the trachea and the proximal bronchi, 12.9% higher for the item 5, visually sharp reproduction of the diaphragm and costo-phrenic angles, 10% higher for the item 6, reproduction of the spine and paraspinal structures and visualisation of the retrocardiac lung and the mediastinum, and 3.65% higher for the item 7. Items 2 and 3 showed no statistically significant differences(P > 0.05), and items 1, 4, 5, 6, and 7 showed statistically significant differences(P < 0.05). In conclusion, Upright method using ADCR in pediatric chest X-ray is considered as a good alternative to existing Supine method.

On the Breeding of “CSR18${\times}$CSR19”- A Robust Bivoltine Hybrid of Silkworm, Bombyx mori L. for the Tropics

  • Kumar, N.Suresh;Basavaraja, H.K.;Kumar, C.M.Kishor;Reddy, N.Mal;Datta, R.K.
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.5 no.2
    • /
    • pp.153-162
    • /
    • 2002
  • Earlier breeding experiments undertaken at Central Sericultural Research and Training Institute, Mysore, India since a decade had resulted in the development of many productive and qualitatively superior bivoltine hybrids. However, the hot climatic conditions of tropics prevailing particularly in summer are not conducive to rear these high yielding bivoltine hybrids. This has necessitated breeding of compatible bivoltine hybrids for year-round rearing. Accordingly, the Japanese hybrid, B2Ol ${\times}$ BCS12 which was found to be tolerant to high temperature was used as breeding resource material. Following hybridization and selection rearing of silkworms was taken up in SERICATRON (Environmental chamber with precise and automatic control facilities for uniform maintenance of temperature and humidity) at high temperature of $36{\times}1^{\circ}C$ and 85${\times}$5% RH in fifth instar and the control batches at $25{\times}1^{\circ}C$ and 65{\times}$5% RH. Directional selection was resorted to the batches reared at 36$\pm$1$^{\circ}C$ till F$_{5}$ keeping pupation rate as important selection criteria. From $F_{2}% onwards the experiment was modified in such a way as to conduct normal rearing every alternate generation to regain the lost vitality due to continuous exposure to high temperature and high humidity stress. At $F_{2}$ , Oval and dumb-bell cocoons were separated out and designated as CSR18 and CSR19, respectively. By utilizing these lines at $F_{12}$, the hybrid CSR18$\times$CSR19 was prepared and studied for the thermotolerance by subjecting to stress condition at high temperature of 36$\pm$1$^{\circ}C$ and 85$\pm$5% RH in fifth instar and the control batches at $25{\times}1^{\circ}C$ and 65${\times}$5% RH. The better performance of CSR18${\times}$CSR19 (survival > 88%) at $36{\times}1^{\circ}C$ clearly indicates the general superiority of CSR18${\times}$CSR19 with regard to high temperature tolerance over the productive hybrids and CSR18$\times$CSR19 can perform well in varied agro-climatic conditions of the tropics with optimum qualitative and quantitative characteristics.s.

Comparison of Average Glandular Dose in Screen-Film and Digital Mammography Using Breast Tissue-Equivalent Phantom (유방조직등가 팬텀을 이용한 Screen-Film과 Digital Mammography에서의 평균 유선선량)

  • Shin, Gwi-Soon;Kim, Jung-Min;Kim, You-Hyun;Choi, Jong-Hak;Kim, Chang-Kyun
    • Journal of radiological science and technology
    • /
    • v.30 no.1
    • /
    • pp.13-23
    • /
    • 2007
  • In recent years, mammography system is changed rapidly from conventional screen-film system to digital system for application to screening and diagnosis. Digital mammography system provides several advantages over screen-film mammography system. According to the information provided by the manufacturer, digital mammography system offers radiation dose reduction in comparison with screen-film mammography system, because of digital detector, particularly direct digital detector has higher x-ray absorption efficiency than screen-film combination or imaging plate(IP). We measured average glandular doses(AGD) in screen-film mammography(SFM) system with slow screen-film combination, computed mammography(CM) system, indirect digital mammography(IDM) system and direct digital mammography(DDM) system using brest tissue-equivalent phantom(glandularity 30%, 50% and 70%). The results were shown as follows : AGD values for DDM system were highest than those for other systems. Although automatic exposure control(AEC) mode was selected, the curve of the AGD values against thickness or glandularity increased significantly for the SFM system with the uniform target/filter(Mo/Mo) combination. Therefore, the AGD values for the high energy examinations were highest in the SFM system, and those for the low energy examinations were highest in the DDM system. But the curve of the AGD values against thickness and glandularity increased gently for CM system with the automatic selection of the target/filter combination (from Mo/Mo to Mo/Rh or from Mo/Rh to Rh/Rh), and the AGD values were lowest. Consequently, the parameters in mammography for each exposure besides detection efficiency play an important role in oder to estimate a patient radiation dose.

  • PDF

Survery on Business of the Departments of Radiology in Health Centers (보건소(保健所)의 방사선과(放射線科) 업무(業務)에 관한 조사연구(調査硏究))

  • Choi, Jong-Hak;Jeon, Man-Jin;Huh, Joon;Park, Sung-Ock
    • Journal of radiological science and technology
    • /
    • v.8 no.2
    • /
    • pp.21-28
    • /
    • 1985
  • We serveyed the actual condition of business of the departments of radiology of 45 health conters (except 3) in the area of Seoul, Kyungki and Inchon from March, 1984 to November, 1984. The results are summarized as follows : 1. T.O. of the radiologic technologist is three persons in each health center of Seoul area, and one person in each one of Kyungki and Inchon area. P.O. is 2-5 persons in Seoul area, 1-2 persons in Kyungki or Inchon area. 2. The number of all the radiologic technologists employed now is 75 persons, and among all of them, when analized by position class 7th is 54.7%, class 8th 28.0%, class 9th is 13.3%, and class 6th is 2.7%, and by sex, female is 68.0%, male is 32.0%, by educational background, for the most part, junior college graduates come to 73.3%, by age group 60% of them is in their twenties, 16.0% is in their thirties and forties, 8.0% is in their fifties, and by career after certificate 60% have the career of 1-5 years, 13.3% have the one of 6-7 years or mor than 21 years, and 6.7% have the one of 11-15 years of 16-20 years. 3. All the diagnostic x-ray equipment being kept is 62, and among them flxing equipment is 71.0%, portable equipment is 29.0% and by rating of X-ray equipment, maximum tube current 100 mA is 46.8%, maximum KV 100KVP is 72.6%, the most part. 4. Photofluorographic camera and hood are equipped in every health center. While, as to the radiographic cassettes, $14{\times}14"$ cassetts are equipped in every health center, but cassettes of other sizes are in half of them. 5. Bucky's table is equipped in 11.9% health centers, the automatic processor is in 21.4%, the photofluorographic film changer is 9.5%, the grid is 73.8%, the protective apron is in 88.1%, and the protective glove is in 57.1% health centers. 6. The number of the people who got the x-ray examination for one year (by the year 1989) is the most, 1,000-6,000 in direct radiography of the chest, or 15,0001-45,000 in the health centers of Seoul area, 5,000-20,000 in Kyungki and Inchon area in photofluorography of the chest. Moreover, other radiographies are being taken extremely limitedly in all health centers. 7. In processing types of x-ray film, automatic processing is used in 9 health centers (21.4%), manual tank processing is in 30 (71.4%), and manual tray processing in 3 (7.2%). 8. As for collimation of x-ray exposure field, "continual using restricted by a subject size" has the most part, 78.6% "restricted using at every radiography" has 19%, and the case of "never considered" has 2.4% response. 9. As for the dosimeter used for radiation control, film badge (35.7%) and pocket dosimeter (26.2%) are used, and in 38.1% health centers the dosimeter is not equipped at all. Consideration of the previous radiation exposure is being done in only one health center. 10. Reading of radiographs is mainly depended on the radiologists electively (45.2%) or on the genral practitioners(45.2%).

  • PDF

Consecutive automated production of carbon-11 labeled radiopharmaceuticals by sharing 11C-methylation reagent from one 11C-synthetic module

  • Park, Hyun Sik;Lee, Hong Jin;An, Hyun Ho;Moon, Byung Seok;Lee, Byung Chul;Kim, Sang Eun
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.2 no.2
    • /
    • pp.123-131
    • /
    • 2016
  • Increasing clinical demand for carbon-11 labeled radiopharmaceuticals has triggered technological advances in fields of radiochemistry and automated modules. Even though carbon-11 has a short half-life ($t_{1/2}=20.4min$), the consecutive second production of carbon-11 labeled radiopharmaceutical in one $^{11}C$-synthetic module should be delayed at least over 4 h to avoid the high radiation exposure. We herein aimed to produce two different carbon-11 labeled radiopharmaceuticals ([$^{11}C$]PIB and [$^{11}C$]methionine) by sharing of [$^{11}C$]methylation source in one $^{11}C$-synthetic module. The synthesis of $^{11}C$-labeling reagents ($[^{11}C]CH_3I$ or $[^{11}C]CH_3OTf$) is fully automated using the commercial TRACERlab $FX_{C-pro}$ module and is readily adaptable to $^{11}C$-labeling reactor for [$^{11}C$]PIB as well as another $^{11}C$-labeling apparatus for [$^{11}C$]methionine via the three-way valve. After completing the [$^{11}C$]PIB production, the re-synthesized $[^{11}C]CH_3I$ was passed through the three-way valve connected the polyetheretherketone (PEEK) line and loaded into the C18 Sep-Pak cartridge including the methionine precursor. The labeled product [^${11}C$]methionine was purified by a simple cartridge separation and reformulated into saline. The radiochemical yield of [$^{11}C$]PIB and [$^{11}C$]methionine were $5.3{\pm}0.6%$ and $18.7{\pm}0.8%$ (n.d.c.), respectively, with over 97% of radiochemical purity. The specific activity of [$^{11}C$]PIB was over $110GBq/{\mu}mol$. Total production time of two radiopharmaceuticals needs about 2 h from $1^{st}$ beam irradiation including quality control tests. Final [$^{11}C$]PIB and [$^{11}C$]methionine were satisfied all quality control test standards.