• Title/Summary/Keyword: Automatic Distribution System

Search Result 355, Processing Time 0.03 seconds

Automatic Protection Schemes for Distribution System with Open and Closed-loop

  • Guan, Kang-Le;Lee, Seung-Jae;Choi, Myeon-Song
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.5
    • /
    • pp.969-974
    • /
    • 2013
  • Protection issues in distribution systems which are to be operated in open and closed-loop modes in a smart grid are studied and a generalized protection setting method is proposed to meet the new requirements. The developed setting method assumes a conventional over-current protection scheme for the system with reclosers and over-current relays. In a closed-loop mode, it identifies protective devices that have to be sacrificed in order to maximize protection coordination for bidirectional fault current flow. The proposed setting method has been tested on many systems with different complexity and is proved effective.

Estimation of spatial distribution of precipitation by using of dual polarization weather radar data

  • Oliaye, Alireza;Bae, Deg-Hyo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.132-132
    • /
    • 2021
  • Access to accurate spatial precipitation in many hydrological studies is necessary. Existence of many mountains with diverse topography in South Korea causes different spatial distribution of precipitation. Rain gauge stations show accurate precipitation information in points, but due to the limited use of rain gauge stations and the difficulty of accessing them, there is not enough accurate information in the whole area. Weather radars can provide an integrated precipitation information spatially. Despite this, weather radar data have some errors that can not provide accurate data, especially in heavy rainfall. In this study, some location-based variable like aspect, elevation, plan curvature, profile curvature, slope and distance from the sea which has most effect on rainfall was considered. Then Automatic Weather Station data was used for spatial training of variables in each event. According to this, K-fold cross-validation method was combined with Adaptive Neuro-Fuzzy Inference System. Based on this, 80% of Automatic Weather Station data was used for training and validation of model and 20% was used for testing and evaluation of model. Finally, spatial distribution of precipitation for 1×1 km resolution in Gwangdeoksan radar station was estimates. The results showed a significant decrease in RMSE and an increase in correlation with the observed amount of precipitation.

  • PDF

A Real-Time Histogram Equalization System with Automatic Gain Control Using FPGA

  • Cho, Jung-Uk;Jin, Seung-Hun;Kwon, Key-Ho;Jeon, Jae-Wook
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.4 no.4
    • /
    • pp.633-654
    • /
    • 2010
  • High quality camera images, with good contrast and intensity, are needed to obtain the desired information. Images need to be enhanced when they are dark or bright. The histogram equalization technique, which flattens the density distribution of an image, has been widely used to enhance image contrast due to its effectiveness and simplicity. This technique, however, cannot be used to enhance images that are either too dark or too bright. In addition, it is difficult to perform histogram equalization in real-time using a general-purpose computer. This paper proposes a histogram equalization technique with AGC (Automatic Gain Control) to extend the image enhancement range. It is designed using VHDL (VHSIC Hardware Description Language) to enhance images in real-time. The system is implemented with an FPGA (Field Programmable Gate Array). An image processing system with this FPGA is implemented. The performance of this image processing system is measured.

RFID-Based Automatic Inspection System Design and Implementation for Manufacturing and Retail Industry (제조 및 유통산업을 위한 RFID 기반 자동 검수 시스템의 설계 및 구현)

  • Kim, Jin-Suk;Park, Jong-Kwon;Shin, Yong-Tae
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39C no.1
    • /
    • pp.97-105
    • /
    • 2014
  • Current manufacturing and distribution industries work with handwritten shipping information or receive operation results in excel files and have to go through computer processing for their logistics. Thus, hand writing error or computer entry error, non-real-time data processing, quantity shortage and excess operating problems have been frequently occurring in many logistics points. In this paper, we will be proposing a RFID based automatic inspection system that will ensure more accurate data for inbound and outbound. Real-time data processing and automatic inspection system will show cost saving effect compared to the existing system.

Dynamics Analysis of Pressure Control Characteristics in a Variable Pressure Solenoid Valve (비례제어방식 솔레노이드 밸브 압력제어특성에 관한 동적해석)

  • 김형만;태혁준;이현우;이창훈
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.6
    • /
    • pp.80-85
    • /
    • 2003
  • In the present paper, dynamics analyses of pressure control characteristics have been performed in a variable pressure solenoid valve. A number of solenoid valves have been used in the electronic control system, especially automatic transmission of an automobile. Variable pressure solenoid valve is intended to produce spatial movement by the electrical signal. Dynamics analyses of pressure control characteristics have been practiced by the Finite Difference Method, which show the pressure distribution in the solenoid valve. The results of numerical analyses show the dependence of pressure distribution on the displacement of the spool in the solenoid valve, and then, are compared with the experimental results.

A Development of Energency Power Automatic Transfer Module in home (가정용 비상 전원 절체 모듈 개발)

  • Joo, Nam-Kyu;Kim, Kwan-Yuong;Kim, Nam-Ho;Lee, Jong-Myong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.321-323
    • /
    • 2009
  • When power failure occurs at multi-housing complex, auxiliary generator or emergency generator starts to provide power to households. This power is connected to emergency power ELB(Earth Leakage Breaker) at home distribution panel board and supplies power only for emergency light in living room but for heating system, refrigerator and other inevitable apparatuses that are in need of uninterruptible power. Since those domestic appliance are fed from common power line, they are inoperable during power failure. Our research is to resolve this problem by developing compatible relay-drive common/emergency-power ATS (automatic transfer switch) for home distribution panel board. In case of power failure, it transfers automatically and commences to provide power from emergency generator. Through this, Consumers can reach satisfaction where common power loads operate without any problem under both ordinary and power failure condition.

  • PDF

Quantitative Evaluation of the Impact of Low-Voltage Loads due to Repetitive Voltage Sags

  • Yun Sang-Yun;Kim Jae-Chul;Moon Jong-Fil;Kang Bong-Seok
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.3
    • /
    • pp.293-299
    • /
    • 2005
  • Automatic reclosing is a typical protection method in power distribution systems for the clearing of temporary faults. However, it has a fatal weakness in regards to voltage sags because it produces repetitive voltage sags. In this paper, we explored the repetitive impact of voltage sag due to the automatic reclosing of power distribution systems. The actual tests of low voltage loads were carried out for obtaining the susceptibility of voltage sags. The final results of the tests yielded power acceptability curves of voltage sag, and the curves transformed the 3-dimensional CBEMA (Computer Business Equipment Manufacturer Association) format. For the quantitative evaluation of the impact of repetitive voltage sags, an assessment formulation using the voltage sag contour was proposed. The proposed formulation was tested by using the voltage sag contour data of IEEE standard and the results of the test. Through the case studies, we verified that the proposed method can be effectively used to evaluate the actual impact of repetitive voltage sags.

Design of Heuristic Algorithm of Automatic Vehicle Delivery Support System (자동배차 지원시스템의 휴리스틱 알고리듬 설계)

  • Lee, Myeong-Ho
    • Journal of Digital Convergence
    • /
    • v.11 no.3
    • /
    • pp.181-187
    • /
    • 2013
  • Moreover a new logistics concept is needed through the sharing information between suppliers and consumers, which maximizes the level of customers service and its flexibility by changing functional-oriented to process-oriented. In other words, Supply Chain Management(SCM) is now considered as a key aspect of business, which controls the flows of information, funds, and goods in the supply chain. Rationalization of transport-delivery system will be one of the most important issues on logistics management to the domestic companies. The companies need the effective delivery system. Especially in the case of delivery system from distribution centers to customers or vendors, it might take a long time to control the delivery system manually because it would be hard to apply the automatic vehicle routing algorithm effectively considering all the practical constraints. Thus this study develops a heuristic algorithm of automatic vehicle delivery support system in terms of grouping by short ranges of vehicle movement utilizing postal coordinates, which satisfies a variety of realistic constraints and reduces controlling time of manual operations.

The Study of characteristic comparison with inrush and fault current occurred in distribution system (배전계통에서 발생하는 돌입전류와 고장전류의 특성 비교연구)

  • 오용택;김진성
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.51-58
    • /
    • 2001
  • This paper gives a type and high-frequency waves analysis of in-rush current cab be flowed into distribution automatic machine to be installed in distribution line in order to use minimizing operation error of failure indicator to have been issue recent with obtaining high-frequency component that can be different from current. The in-rush and fault current data studied in this paper is to be surveyed actually in USA distribution system substation line of Bryan Power Company near Texas A. M University, to be occurred high impedance fault.

  • PDF

Application of Genetic Algorithm for Loss Minimization in Distribution Systems (배전계통에서 손실 최소화를 위한 유전자 알고리즘의 적용)

  • Jeon, Young-Jae;Kim, Hoon;Lee, Seung-Youn;Son, Hag-Sig;Park, Soung-Ok;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.156-158
    • /
    • 2000
  • This paper presents a efficient algorithm for loss reduction of distribution system by automatic sectionalizing switch operation in distribution systems of radial type. To apply genetic algorithm to reconfiguration of distribution system, in this paper we propose the string type and efficient reconfiguration procedure. We also discuss the more elaborate search techniques of solution space as well as the simple genetic algorithm. The experimental results show that the proposed genetic algorithm have the ability to search a good solution.

  • PDF